MC1330 [LAMBDA]
MC13-SERIES;型号: | MC1330 |
厂家: | DENSEI-LAMBDA |
描述: | MC13-SERIES |
文件: | 总4页 (文件大小:1155K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MC13-SERIES
Ⅵ Features
(1) 2 mounting options :
MC13**
Screw mounting type
MC13**DIN Din rail mounting type
(2) Worldwide compliance :
Voltage rating 3 phase AC500V, 10, 20, 30A
(3) Safe design :
Terminal with cover, Low leakage current
(4) Environmental compliance : Lead free soldering
Ⅵ Safety standard
UL1283
CSA Std. C22. 2 No. 8
EN133200
EN133200
Ⅵ Specifications
Model
STD type
DIN type
MC1306
MC1310
MC1320
MC1330
Items
MC1306DIN
MC1310DIN
MC1320DIN
MC1330DIN
1
2
3
4
5
6
7
8
9
Rated Voltage (AC)
Rated Current (*1)
500V (50/60Hz)
6A
10A
20A
30A
Test Voltage (terminals to base plate, 1min AC)
Isolation Resistance (terminals to base plate, 500VDC)
2000V (100mA) at 25°C, 70% RH
100MΩmin at 25°C, 70% RH
5.0mA max
Leakage Current
500V,60Hz
DC Resistance (three lines)
Temperature Rise
90mΩmax
68mΩmax
23mΩmax
30°C max
11mΩmax
Operating Temperature
Operating Humidity
-25°C ~ +85°C
30% ~ 95% RH (No Dewdrop)
-40°C ~ +85°C
10 Storage Temperature
11 Storage Humidity
10% ~ 95% RH (No Dewdrop)
At no operating 10~55~10Hz, Amplitude (Sweep for 1min) 0.825mm constant (Maximum 49.0m/s2)X,Y,Z 1hour each
At no operating 55~250~55Hz, Acceleration (Sweep for 1min) 19.6m/s2, X,Y,Z 1hour each
MC13**
12 Vibration
13 Weight
MC13**DIN
At no operating 10~55~10Hz, Acceleration (Sweep for 1min) 9.8m/s2, X,Y,Z 1hour each
600g
<
(Note) : Value for Ta
=
50°C For Ta>50°C derate according to the derating curve shown on the right.
Ⅵ Circuit
Ⅵ Derating
Temperature (°C)
Ⅵ Terminal Explanation
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
163
MC13-SERIES
Ⅵ MC13
**
(Unit: mm)
Ⅵ MC13 DIN
**
(Unit: mm)
Ⅵ MC13 DIN explanation
*Mounting
**
*Ground
MC13 DIN could be mounted on 35mm wide (TS35 type) Din-rail.For mounting,
Do not earth whth Din-rail.
**
put the part (A) of the unit over the top hat rail and push forward like (B), so that
the rail stopper is firmly held on the Din-rail. For unmounting, put a screw driver
int the part (C) and lift it up to remove the unit.
Earth directly from the ground terminal of
MC13 DIN.
**
A
B
C
164
MC13-SERIES
CHARACTERISTICS
Ⅵ Attenuation Characteristic (typical)
MC1306
MC1310
165
MC13-SERIES
CHARACTERISTICS
Ⅵ Attenuation Characteristic (typical)
MC1320
MC1330
166
©2020 ICPDF网 联系我们和版权申明