PBF-1201 [LAMBDA]
Equipment Designed to Conform EMI Regulations Such As VCCI,CISPR,FCC,VDE,etc; 设备设计符合EMI法规,如VCCI , CISPR , FCC , VDE等型号: | PBF-1201 |
厂家: | DENSEI-LAMBDA |
描述: | Equipment Designed to Conform EMI Regulations Such As VCCI,CISPR,FCC,VDE,etc |
文件: | 总2页 (文件大小:134K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PBF-SERIES
Ⅵ Features
(1) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(2) Attenuates conductive emission from power
supply
(3) Leakage current: 0.75mA max. (250V, 60Hz)
(4) Compact package
(5) Simple wiring and easy maintenance by
fast-on tab
(6) Low price
PBF-1206-22
PBF-1203-22
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
VDE0565 will transfer to EN133200
on and after July 23, 2003.
(
)
PBF-1202-22
PBF-1201-22
Ⅵ Specifications
Model
(Note)
PBF-1201-22
PBF-1202-22
2A
PBF-1203-22
3A
PBF-1206-22
6A
Item
1
2
3
4
Rated voltage (AC, DC)
Rated current (AC, DC)
250V
1A
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
2500V
100MΩ min.
0.35mA max.
0.75mA max.
125V, 60Hz
5
Leakage current
250V, 60Hz
6
7
8
9
DC resistance
1.2Ω max.
0.4Ω max.
0.2Ω max.
0.07Ω max.
Temperature rise
30°C max.
Operating temperature range
–25 ~ +85°C
Weight
(typ)
50g
<
(Note) : Value at Ta 55°C. Refer to the derating curve shown below at Ta > 55°C.
=
Ⅵ Circuit
Ⅵ Derating
Ⅵ Outline drawings
Case: Plastic (PBT, UL94V-0)
(Unit: mm)
ⅷ Request customer specification for further
details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
167
PBF-SERIES
CHARACTERISTICS
.............. Symmetrical
———— Asymmetrical
Ⅵ Typical Insertion Loss
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
168