HX03-SP2 [LEM]

Current Transducer; 电流传感器
HX03-SP2
型号: HX03-SP2
厂家: LEM    LEM
描述:

Current Transducer
电流传感器

传感器
文件: 总2页 (文件大小:645K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Current Transducer HX 03..50-P/SP2  
IPN = 3 .. 50 A  
For the electronic measurement of currents: DC, AC, pulsed, mixed,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
Electrical data  
Primarynominal Primary current,  
current rms  
Primary conductor  
diameter x turns  
(mm)  
Type  
RoHS since  
date code  
measuring range1)  
Features  
IPN (A)  
IPM (A)  
· Galvanicisolationbetweenprimary  
andsecondarycircuit  
· Halleffectmeasuringprinciple  
· Isolationvoltage 3000V  
3
5
± 9  
0.6d x 20T  
0.8d x 12T  
1.1d x 6T  
1.4d x 4T  
1.6d x 3T  
HX 03-P/SP2  
HX 05-P/SP2  
HX 10-P/SP2  
HX 15-P/SP2  
HX 20-P/SP2  
HX 25-P/SP2  
HX 50-P/SP2  
46128  
46019  
45352  
46133  
planned  
46233  
46152  
± 15  
± 30  
± 45  
± 60  
± 75  
± 150  
10  
15  
20  
25  
50  
· Low power consumption  
1.6d x 2T  
1.2 x 6.3 x 1T  
· Extended measuring range(3x IPN  
· Insulated plastic case recognized  
according to UL94-V0.  
)
VOUT  
Output voltage (Analog) @ ± IPN, RL = 2 kW, TA = 25°C VOE ± 0.625  
V
W
ROUT  
RL  
VC  
IC  
Output internal resistance  
Load resistance  
< 50  
³ 2  
kW  
V
Special feature  
Supply voltage (± 5 %)  
+ 12 .. 15  
< 15  
> 3  
Current consumption  
mA  
kV  
kV  
kV  
· Single supply from +12V to +15V  
Vd  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Ve  
Partial discharge extinction voltage rms @ 10 pC ³ 1  
Impulse withstand voltage, 1.2/50 µs ³ 6  
Advantages  
VW  
· Low insertion losses  
· Easy to mount with automatic  
handling system  
· Small size and space saving  
· Only one design for wide current  
ratings range  
Accuracy-Dynamic performance data  
X
Accuracy @ IPN, TA = 25°C (excluding offset)  
Linearity error (0 .. ± IPN)  
< ± 1 % of IPN  
< ± 1 % of IPN  
+ 2.5V ± 50 mV  
e
L
VOE  
VOH  
Electrical offset voltage @ TA = 25°C  
Hysteresis offset voltage @ IP = 0;  
after an excursion of 1 x IPN  
· High immunity to external  
interference.  
< ± 10  
mV  
TCVOE  
TCVOUT  
tr  
Temperature coefficient of VOE  
< ± 1.5 mV/K  
Temperature coefficient of VOUT (% of reading)  
Response time to 90% of IPN step  
Frequency bandwidth (- 3 dB) 2)  
± 0.1  
£ 3  
%/K  
µs  
Applications  
BW  
50  
kHz  
· Switched Mode Power Supplies  
(SMPS)  
General data  
· ACvariablespeeddrives  
· UninterruptiblePowerSupplies  
(UPS)  
· Electricalappliances  
· Batterysuppliedapplications  
· DC motor drives  
TA  
Ambient operating temperature  
Ambient storage temperature  
Mass  
- 25 .. + 85 °C  
- 25 .. + 85 °C  
TS  
m
8
g
dCp  
Creepage distance  
Isolation material group  
Standards  
³ 5.5  
m m  
I
EN50178: 1997  
Applicationdomain  
· Industrial  
Notes : 1) With RL=2kW  
2)  
Small signal only to avoid excessive heating of the magnetic core  
Page 1/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
061026/5  
www.lem.com  
Dimensions HX 03..50-P/SP2 (in mm. 1 mm = 0.0394 inch)  
HX 03..25-P/SP2  
HX 50-P/SP2  
Max.  
Max.  
19  
19  
Terminal Pin Identification  
1 ..... 0V  
2 ..... 0V  
3 ..... +12V to +15V  
4 ..... Output  
5 ..... Primary input Current (+)  
6 ..... Primary input Current (-)  
10.85  
8.8  
5.4  
3
3
Primary conductor diameter  
d
03-P/  
SP2  
05-P/  
SP2  
10-P/  
SP2  
15-P/  
SP2  
Bottomview  
Bottomview  
HX  
d
6
5
6
5
0.6  
0.8  
1.1  
1.4  
4 OUT  
3 +V  
4 OUT  
3 +V  
20-P/  
SP2  
25-P/  
SP2  
50-P/  
SP2  
HX  
d
0
0
2
1
2
1
-V or 0  
-V or 0  
1.6  
1.6  
1.2 x 6.3  
1.2  
8.8  
3
10.85  
3
5.4  
Secondary pins dimension  
0.5 x 0.25  
Top view  
HX05-P/  
SP2  
41123  
Lot No.  
Safety  
This transducer must be used in electric/electronic equipment  
with respect to applicable standards and safety requirements  
in accordance with the following manufacturer's operating  
instructions.  
Caution, risk of electrical shock  
When operating the transducer, certain parts of the module can  
carry hazardous voltage (eg. primary busbar, power supply).  
Ignoring this warning can lead to injury and/or cause serious  
damage.  
This transducer is a built-in device, whose conducting parts  
must be inaccessible after installation.  
A protective housing or additional shield could be used.  
Main supply must be able to be disconnected.  
Page 2/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
061026/5  
www.lem.com  

相关型号:

HX03013000J0G

Barrier Strip Terminal Block
AMPHENOL

HX03015000J0G

Barrier Strip Terminal Block
AMPHENOL

HX03016000J0G

Barrier Strip Terminal Block
AMPHENOL

HX03232100J0G

Barrier Strip Terminal Block
AMPHENOL

HX03234100J0G

Barrier Strip Terminal Block
AMPHENOL

HX03235100J0G

Barrier Strip Terminal Block
AMPHENOL

HX03236100J0G

Barrier Strip Terminal Block
AMPHENOL

HX04-P

Current Transducer
LEM

HX04003000J0G

Barrier Strip Terminal Block
AMPHENOL

HX0420C100J0G

Barrier Strip Terminal Block
AMPHENOL

HX04228100J0G

Barrier Strip Terminal Block
AMPHENOL

HX04230100J0G

Barrier Strip Terminal Block
AMPHENOL