LTS15-NP_06 [LEM]
Current Transducer; 电流传感器型号: | LTS15-NP_06 |
厂家: | LEM |
描述: | Current Transducer |
文件: | 总3页 (文件大小:175K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IPN = 15 At
Current Transducer LTS 15-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16058
Electrical data
Features
IPN
IPM
Primary nominal current rms
Primary current, measuring range
15
0 .. ± 48
At
At
· Closed loop (compensated) multi-
range current transducer using the
Hall effect
ÎPDC
Overload capability (direct current)
Analog output voltage @ IP
IP = 0
Number of secondary turns (± 0.1 %)
Load resistance
250
At
VOUT
2.5 ± (0.625·IP/IPN)V
· Unipolar voltage supply
2.5 1)
2000
³ 2
V
· Compact design for PCB mounting
· Isolated plastic case recognized
according to UL 94-V0
· Incorporated measuring resistance
· Extended measuring range.
NS
RL
RIM
kW
W
ppm/K
V
Internal measuring resistance (± 0.5 %)
83.33
< 50
5
TCRIM Temperature coefficient of R IM
VC
IC
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
Typ
28+IS2)+(VOUT/RL)mA
Advantages
· Excellent accuracy
Accuracy - Dynamic performance data
· Very good linearity
· Very low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
X
Accuracy @ IPN , TA = 25°C
Accuracy with R IM @ IPN , TA = 25°C
Linearity error
± 0.2
± 0.7
< 0.1
%
%
%
e
L
Typ Maxi
TCVOUT Temperature coefficient of VOUT @ IP = 0 - 10°C .. + 85°C 65 120 ppm/K
- 40°C .. - 10°C
- 40°C .. + 85°C
170 ppm/K
50 3)ppm/K
· Current overload capability.
TCG
VOM
Temperature coefficient of G
Magnetic offset voltage@ IP = 0,
Applications
after an overload of 3 x IPN
± 0.5
± 2.0
± 2.0
mV
mV
mV
· AC variable speed drives and servo
motor drives
5 x IPN
10 x IPN
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
· Switched Mode Power Supplies
(SMPS)
tra
tr
Reaction time @ 10 % of IPN
Response time to 90 % of IPN step
< 100
< 400
> 35
DC .. 100
DC .. 200
ns
ns
A/µs
kHz
kHz
di/dt di/dt accurately followed
BW
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
· Power supplies for welding
applications.
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 40 .. + 85
- 40 .. + 100
10
°C
°C
g
Application domain
· Industrial.
Standards
EN 50178: 1997
IEC 60950-1: 2001
Copyright protected.
1)
Notes:
Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
IS= IP/N S
Only due to TCRIM.
2)
3)
Page 1/3
061102/17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Current Transducer LTS 15-NP
Isolation characteristics
Vd
Vw
Rms voltage for AC isolation test, 50/60 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
3
>8
kV
kV
Mini
>1.5
Ve
Rms voltage for partial discharge extinction @ 10pC
kV
Mini
15.5
6.35
175
4)
dCp
dCl
CTI
Creepage distance
Clearance distance
m m
m m
5)
Comparative Tracking Index (Group III a)
Applicationexamples
According to EN 50178 and IEC 61010-1 standards and following conditions:
· Over voltage category OV 3
· Pollution degree PD2
· Non-uniform field
EN 50178
Rated isolation voltage
600 V
IEC 61010-1
Nominal voltage
600 V
dCp, dCI,
VW
Single isolation
Reinforced isolation
300 V
300 V
4)
Notes:
On housing
On PCB with soldering pattern UTEC93-703.
5)
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
061102/17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Dimensions LTS 15-NP (in mm. 1 mm = 0.0394 inch)
Operation principle
Bottom view
Front view
Back view
Right view
Number
of primary
turns
Primary nominal
current rms
IPN [ A ]
Nominal
output voltage
VOUT [ V ]
Primary
resistance
RP [ mW ]
Primary
insertion inductance
LP [ µH ]
Recommended
connections
6
5
4
OUT
OUT
OUT
1
2
3
± 15
± 7.5
± 5
2.5 ± 0.625
2.5 ± 0.625
2.5 ± 0.625
0.18
0.81
1.62
0.013
0.05
0.12
IN
IN
IN
1
6
2
5
3
4
1
6
2
5
3
4
1
2
3
Mechanical characteristics
Output Voltage - Primary Current
VOUT [ V]
· General tolerance
± 0.2 mm
· Fastening & connection of primary
Recommended PCB hole
6 pins 0.8 x 0.8 mm
1.3 mm
5
4.5
· Fastening & connection of secondary 3 pins 0.5 x 0.35 mm
3.125
2.5
Recommended PCB hole
0.8 mm
· Additional primary through-hole
Æ 3.2 mm
1.875
Remarks
0.5
· VOUT is positive when IP flows from terminals 1, 2, 3 to
terminals 6, 5, 4.
· Temperature of the primary jumper should not exceed 100°C.
IP [ At]
- IP
- IPN
0
IPN
IP
Page 3/3
061102/17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.