LV100-100_03 [LEM]
Voltage Transducer; 电压互感器型号: | LV100-100_03 |
厂家: | LEM |
描述: | Voltage Transducer |
文件: | 总2页 (文件大小:58K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Voltage Transducer LV 100-100
VPN = 100 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
VPN
VP
IPN
Primary nominal r.m.s. voltage
Primary voltage, measuring range
Primary nominal r.m.s. current
Measuring resistance
100
0 .. ± 150
100
V
V
mA
Features
· Closed loop (compensated) voltage
transducer using the Hall effect
· Insulated plastic case recognized
according to UL 94-V0
· Primary resistor R 1 incorporated into
the housing.
RM
RM min
RMmax
with ± 15 V
@ ± 100 V max
@ ± 150 V max
0
0
170
90
W
W
ISN
KN
VC
IC
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50
mA
100 V / 50 mA
± 15
10 + IS
6
V
mA
kV
Advantages
Vd
· Excellent accuracy
· Very good linearity
· Low thermal drift
· High immunity to external
interference.
Accuracy - Dynamic performance data
X
Overall Accuracy @ VPN , TA = 25°C
Linearity
± 0.7
< 0.1
%
%
eG
L
Applications
Typ Max
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
± 0.2 mA
± 0.2 ± 0.3 mA
· AC variable speed drives and servo
motor drives
0°C .. + 70°C
tr
Response time @ 90 % of VPN
50
µs
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
General data
· Power supplies for welding
applications.
TA
TS
N
Ambient operating temperature
Ambient storage temperature
Turns ratio
Total primary power loss
Primary resistance @ TA = 25°C
Secondary coil resistance @ TA = 70°C
Mass
0 .. + 70
- 25 .. + 85
1000 : 2000
10
1
60
°C
°C
P
W
kW
W
R1
RS
m
850
g
Standards
EN 50178
030224/2
LEM Components
www.lem.com
Dimensions LV 100-100 (in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
Remarks
· General tolerance
· Transducer fastening
± 0.3 mm
· IS is positive when VP is applied on terminal +HT.
· The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
· This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
2 holes Æ 6.5 mm
M6 steel screws
5 Nm or 3.69 Lb - Ft.
M5 threaded studs
Faston 6.3 x 0.8 mm
M5 threaded stud
2.2 Nm or 1.62 Lb. -Ft.
Fastening torque max
· Connection of primary
· Connection of secondary
· Connection to the ground
· Fastening torque max
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
相关型号:
©2020 ICPDF网 联系我们和版权申明