455C54 [LGE]

Ceramic Discriminator; 陶瓷鉴
455C54
型号: 455C54
厂家: LGE    LGE
描述:

Ceramic Discriminator
陶瓷鉴

文件: 总3页 (文件大小:422K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
455C54  
Ceramic Discriminator  
1. APPLICATION  
This specification is applied to ceramic discriminator : 455C54  
used for quadrature detection with IC : TA31142F (TOSHIBA )  
2. SPECIFICATION No.: QJ/A5250512  
MODEL NAME  
Part Name  
55C54  
Customer’s Part No.  
Customer’s Draving No.  
3. DIMENSIONS : ( mm )  
Material List  
Polybutenetelephthalate  
Case  
(mixture of glass fiber)  
Phosphor bronze Ag Clad  
Epoxy resin  
Terminal  
Base Sealing  
4. MAXIMUM RATINGS  
4.1 Withstanding Voltage  
(Between each terminal)  
:
D.C. 5OV. 1 minute  
4.2 Insulation Resistance  
(Between each terminal)  
:
100 MΩ min. at D.C. 100V  
4.3 Input signal level  
:
5dB (50Ω Termination )  
- 20to + 80 ℃  
25 ±5℃  
4.4 Operating Temperature Range  
4.5 Storage Temperature Range  
:
:
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD  
.
455C54  
Ceramic Discriminator  
5. ELECTRICAL CHARACTERISTICS  
Item  
( 0to + 40 )  
Requirements  
±4.0 KHz min.  
40 ± 20 mV  
5-1  
5-2  
5-3  
5-4  
Receiver Audio 3dB Bandwitdth (from 455KHz)  
Receiver Audio Output Voltage (at 455KHz)  
Distortion (at 455 KHz)  
3.0% max.  
Withstanding Voltage  
50V D.C. for 1 minute  
5-5 Test Method  
Input signal Condition Input level  
: 80dB  
Frequency Deviation : ±4.0KHz  
Modulation Frequency : 1 KHz  
1) Recoverd Audio  
3dB Bandwidth  
Input the above signal and sweep the carrier frequency  
around 455 KHz and find out the maximum audio  
output frequency. Then sweep the carrier frequency  
again and find two frequencies which are observed  
-3dB attenuation points from the maximum point .  
Higher frequency point is called (f1) and lower called  
(f2), (f1-455KHz)is defined as upper 3dB bandwidth  
and (455Khz-f2) defined as lower 3 dB bandwidth.  
2) Receiver Audio  
Output Voltage  
Receiver audio output voltage shall be measured  
when carrier frequency is adjusted to 455KHz.  
3) Distortion  
Carrier frequency is adjusted to 455Khz. And  
then ,distortion shall be measured with 1 kHz  
modulation frequency.  
6. PRYSICAL AND ENVIRONMENTAL CHARACTERISTICS  
Test Item  
Condition of Test  
Requirements  
6-1 Lead Strength After force 1.0Kg is applied to each lead in axial direction.  
Lead Pulling filter shall be measured.  
No  
mechanical  
and the  
Lead Bending When force of 0.5Kg is applied to each lead in axial damage  
measured values shall  
meet item 5.  
direction the lead shall be folded up to 90 from the axial  
direction and folded back to the axial direction .  
Filter shall be measured after being applied vibration of  
amplitude of 1.5mm with 600 to 3,300 r.p.m. band of  
vibration frequency to each of 3 perpendicular directions  
for 2 hour .  
6-2  
Vibration  
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD  
.
455C54  
Ceramic Discriminator  
6-3 Random Drop Filter shall be measured after 3 times random dropping  
from the height of 30cm on concrete floor  
Temperature Filter shall be measured within -20 to +80 ℃  
Characteristics temperature range.  
6-4  
6-5  
Humidity  
Filter shall be measured after being placed in a chamber  
with 90 to 95% R. H. at 40±2for 100 hours and then  
being placed in natural condition for 2 hour.  
The measured values  
shall meet Table 1.  
6-6  
Resistance to  
Lead terminals are immersed up to 1.5mm from filter’s  
Soldering Heat body in soldering bath of 260±5for 5±0.5 seconds and  
then filter shall be measured after being placed in natural  
condition for 2 hour.  
6-7 Life TestHigh Filter shall be measured after being placed in chamber with  
Temperature80for 100 hours and then being placed in natural  
condition for 2 hour.  
6-8  
Life Test  
Filter shall be measured after being placed in a chamber  
Low  
with -20for 100 hours and then being placed in natural  
Temperaturecondition for 2 hours.  
6-9 Thermal Shock After temperature cycling of -2030 minutesto +80℃  
30 minuteswas performed 5 times. Filter shall be  
returned to room temperature. And filter shall be measured  
after being placed in natural condition for 2 hours.  
Item  
Requrements  
Receiver Audio 3dB Bandwidth  
(from 455KHz)  
Receiver Audio Output Voltage  
(at 455KHz)  
±4.0 KHz min.  
40±20 mV  
Distortion  
( at 455KHz)  
4.0 % max.  
Withstanding Voltage  
50V D. C. for 1 minute.  
Table 1.  
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD  
.

相关型号:

455H1.2X

Crystal Filter, 1 Function(s), 0.455MHz, 1.2kHz BW(delta f), Discrete,
GOLLEDGE

455H1.8

Crystal Filter, 1 Function(s), 0.455MHz, 0.9kHz BW(delta f), Discrete,
GOLLEDGE

455H2.1

Crystal Filter, 1 Function(s), 0.455MHz, 1.05kHz BW(delta f), Discrete,
GOLLEDGE

455H2.4

Crystal Filter, 1 Function(s), 0.455MHz, 1.2kHz BW(delta f), Discrete,
GOLLEDGE

455H250

Crystal Filter, 1 Function(s), 0.455MHz, 0.125kHz BW(delta f), Discrete,
GOLLEDGE

455H250X

Crystal Filter, 1 Function(s), 0.455MHz, 0.125kHz BW(delta f), Discrete,
GOLLEDGE

455H400

Crystal Filter, 1 Function(s), 0.4557MHz, 0.2kHz BW(delta f), Discrete,
GOLLEDGE

455H400A

Crystal Filter, 1 Function(s), 0.455MHz, 0.2kHz BW(delta f), Discrete,
GOLLEDGE

455H400X

Crystal Filter, 1 Function(s), 0.455MHz, 0.2kHz BW(delta f), Discrete,
GOLLEDGE

455H500

Crystal Filter, 1 Function(s), 0.455MHz, 0.25kHz BW(delta f), Discrete,
GOLLEDGE

455H500X

Crystal Filter, 1 Function(s), 0.455MHz, 0.25kHz BW(delta f), Discrete,
GOLLEDGE

455H600

Crystal Filter, 1 Function(s), 0.455MHz, 0.3kHz BW(delta f), Discrete,
GOLLEDGE