EQW025A0Y1

更新时间:2024-09-18 08:28:20
品牌:LINEAGEPOWER
描述:36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output

EQW025A0Y1 概述

36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output 36 - 75VDC输入; 1.2Vdc至5V直流输出; 12A至25A输出

EQW025A0Y1 数据手册

通过下载EQW025A0Y1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Data Sheet  
December 12, 2008  
EQW012/020/023/025 Series Eighth-Brick DC-DC Converters:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output Current  
Features  
RoHS Compliant  
ƒ
Compliant to RoHS EU Directive 2002/95/EC (-Z  
versions)  
ƒ
Compliant to ROHS EU Directive 2002/95/EC with  
lead solder exemption (non-Z versions)  
ƒ
ƒ
ƒ
ƒ
ƒ
Delivers up to 25A Output current  
High efficiency – 88% at 3.3V full load (Vin = 48Vdc)  
Low output ripple and noise  
Surface mount or through hole  
Industry standard Eight brick footprint  
57.9mm x 22.8mm x 8.5mm(MAX)  
(2.28in x 0.9in x 0.335in)  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Constant switching frequency  
Remote On/Off Positive logic (primary referenced)  
Remote Sense  
Applications  
ƒ
ƒ
ƒ
ƒ
ƒ
Distributed power architectures  
Wireless Networks  
Adjustable output voltage (± 10%)  
Output overvoltage and overcurrent protection  
Input undervoltage lockout  
Enterprise Networks  
Optical and Access Network Equipment  
Latest generation IC’s (DSP, FPGA, ASIC) and  
Microprocessor powered applications.  
Output overcurrent and overvoltage protection  
Over-temperature protection  
Options  
Wide operating temperature range (-40°C to 85°C)  
UL* 60950-1 Recognized, CSAC22.2 No. 60950-1-  
03 Certified, and VDE0805 (IEC60950, 3rd edition)  
Licensed  
ƒ
ƒ
ƒ
ƒ
Remote On/Off logic (positive or negative)  
Surface Mount (-S Suffix)  
Short pins  
ƒ
ƒ
ISO** 9001 and ISO14001 certified manufacturing  
facilities  
Alternative output voltage adjustment equations  
(1.2V output only, -V Suffix)  
Meets the voltage and current requirements for  
ETSI 300-132-2 and complies with and licensed for  
Basic insulation rating per IEC60950 3rd edition  
Description  
The EQW series, Eighth-brick power modules are isolated dc-dc converters that can deliver up to 25A of output  
current and provide a precisely regulated output voltage over a wide range of input voltages (Vi = 36 -75Vdc). The  
modules achieve full load efficiency of 88% at 3.3V output voltage. The open frame modules construction, available  
in both surface-mount and through-hole packaging, enable designers to develop cost- and space-efficient solutions.  
Standard features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and  
overtemperature protection.  
*
UL is a registered trademark of Underwriters Laboratories, Inc.  
CSA is a registered trademark of Canadian Standards Association.  
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.  
** ISO is a registered trademark of the International Organization of Standards  
Document No: DS03-74 ver. 1.23  
PDF name: eqw_12-25-ds.pdf  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
EQW  
VIN  
-0.3  
80  
Vdc  
Continuous  
Transient (100ms)  
EQW  
All  
VIN, trans  
TA  
-0.3  
-40  
100  
85  
Vdc  
°C  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
All  
All  
Tstg  
-55  
125  
°C  
I/O Isolation Voltage (100% factory Hi-Pot tested)  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
All  
Symbol  
VIN  
Min  
Typ  
Max  
75  
3
Unit  
Vdc  
Operating Input Voltage  
Maximum Input Current  
(VIN=0V to 75V, IO=IO, max  
Input No Load Current  
36  
48  
All  
IIN,max  
Adc  
)
All  
All  
IIN,No load  
75  
3
mA  
mA  
(Vin = 48Vdc, Io = 0, module enabled)  
Input Stand-by Current  
IIN,stand-by  
(Vin = 48Vdc, module disabled)  
Inrush Transient  
All  
All  
All  
I2t  
1
A2s  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V  
to 75V, IO= IOmax ; see Test Configuration section)  
13  
50  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
EMC, EN55022  
See EMC Considerations section  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a fast-acting fuse with a maximum rating of 6A (see Safety Considerations section). Based on the information  
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating  
can be used. Refer to the fuse manufacturer’s data sheet for further information.  
LINEAGE POWER  
2
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Electrical Specifications (continued)  
Parameter  
Device  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
Symbol  
VO, set  
VO, set  
VO, set  
VO, set  
VO, set  
VO, set  
Min  
1.18  
1.47  
1.76  
2.45  
3.25  
4.90  
Typ  
1.2  
1.5  
1.8  
2.5  
3.3  
5.0  
Max  
1.22  
1.53  
1.84  
2.55  
3.35  
5.10  
Unit  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Output Voltage Set-point  
(VIN=VIN,nom, IO=IO, max, Tref=25°C)  
Output Voltage  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
1.8Vdc  
VO  
VO  
VO  
VO  
VO  
VO  
VO  
1.16  
1.45  
1.74  
2.42  
3.2  
1.24  
1.55  
1.86  
2.57  
3.4  
Vdc  
Vdc  
(Over all operating input voltage, resistive load,  
and temperature conditions until end of life)  
Vdc  
Vdc  
Vdc  
4.85  
-10  
5.15  
+12  
Vdc  
Adjustment Range  
% VO, set  
Selected by external resistor  
2.5Vdc  
VO  
-10  
+20  
% VO, set  
3.3Vdc  
VO  
VO  
-20  
+10  
+10  
% VO, set  
% VO, set  
All others  
-10.0  
Output Regulation  
Line (VIN=VIN, min to VIN, max  
Load (IO=IO, min to IO, max  
Temperature (Tref=TA, min to TA, max  
)
All  
All  
All  
0.1  
10  
% VO, set  
mV  
)
)
0.2  
% VO, set  
Output Ripple and Noise on nominal output  
measured with 10μF Tantalum, 1μF ceramic  
(VIN=VIN, nom and IO=IO, min to IO, max  
)
RMS (5Hz to 20MHz bandwidth)  
Peak-to-Peak (5Hz to 20MHz bandwidth)  
RMS (5Hz to 20MHz bandwidth)  
Peak-to-Peak (5Hz to 20MHz bandwidth)  
External Capacitance*  
5.0 Vdc  
5.0 Vdc  
18  
50  
8
35  
90  
mVrms  
mVpk-pk  
mVrms  
mVpk-pk  
μF  
0
All others  
All others  
5.0 Vdc  
20  
40  
75  
CO, max  
CO, max  
3000  
All others  
0
5000  
μF  
Output Current  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
Io  
Io  
Io  
Io  
Io  
Io  
0
0
0
0
0
0
25.0  
25.0  
25.0  
23.0  
20.0  
12.0  
Adc  
Adc  
Adc  
Adc  
Adc  
Adc  
Output Current Limit Inception  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
IO, lim  
IO, lim  
IO, lim  
IO, lim  
IO, lim  
IO, lim  
35  
35  
35  
30  
25  
15  
Adc  
Adc  
Adc  
Adc  
Adc  
Adc  
(Vo = 90% of VO, set  
)
LINEAGE POWER  
3
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Electrical Specifications (continued)  
Parameter  
Device  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
All  
Symbol  
Io,sc  
Io,sc  
Io,sc  
Io,sc  
Io,sc  
Io,sc  
η
Min  
Typ  
42  
Max  
Unit  
Adc  
Adc  
Adc  
Adc  
Adc  
Adc  
%
Output Short-circuit Current  
(Vo = 0.25V)  
42  
42  
40  
37  
25  
Efficiency  
81.0  
81.0  
84.0  
87.0  
88.0  
91.0  
285  
VIN=VIN, nom, TA=25°C  
IO=IO, max , VO= VO,set  
η
%
η
%
η
%
η
%
η
%
Switching Frequency  
fsw  
kHz  
Dynamic Load Response  
All  
Vpk  
200  
mV  
(ΔIo/Δt=0.1A/μs; Vin=Vin,set; TA=25°C)  
Load Change from Io= 50% to 75% of Io,max;  
10μF Tantalum, 1μF ceramic external capacitance  
Peak Deviation  
Settling Time (Vo<10% peak deviation)  
All  
All  
ts  
200  
200  
μs  
Vpk  
mV  
(ΔIo/Δt=0.1A/μs; Vin=Vin,set; TA=25°C)  
Load Change from Io= 50% to 25% of Io,max;  
10μF Tantalum, 1μF ceramic external capacitance  
Peak Deviation  
Settling Time (Vo<10% peak deviation)  
All  
ts  
200  
μs  
Isolation Specifications  
Parameter  
Symbol  
Min  
Typ  
Max  
Unit  
pF  
Isolation Capacitance  
CISO  
RISO  
1000  
10  
Isolation Resistance  
MΩ  
General Specifications  
Parameter  
Device  
Min  
Typ  
Max  
Unit  
Calculated Reliability Based upon Telcordia SR-  
MTBF  
FIT  
F-S  
3,287,361  
Hours  
109/Hours  
332 Issue 2: Method I, Case 1, (IO=80%IO, max  
,
F-S  
304  
TA=40°C, Airflow = 200 lfm), 90% confidence  
Weight  
15.2 (0.6)  
g (oz.)  
LINEAGE POWER  
4
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Feature Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions. See Feature Descriptions for additional information.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Remote On/Off Signal Interface  
(VIN=VIN, min to VIN, max ; open collector or equivalent,  
Signal referenced to VIN- terminal)  
Negative Logic: device code suffix “1”  
Logic Low = module On, Logic High = module Off  
Positive Logic: No device code suffix required  
Logic Low = module Off, Logic High = module On  
Logic Low Specification  
Remote On/Off Current – Logic Low  
On/Off Voltage:  
All  
Ion/off  
0.15  
1.0  
mA  
Logic Low  
All  
All  
All  
Von/off  
Von/off  
Ion/off  
-0.7  
1.2  
15  
10  
V
V
Logic High – (Typ = Open Collector)  
Logic High maximum allowable leakage current  
Turn-On Delay and Rise Times  
μA  
(VI =48Vdc, IO=IO, max , VO to within ±1% of steady state)  
Case 1: On/Off input is set to Logic high and then  
input power is applied (delay from instant at  
which VI = VI,min until Vo = 10% of Vo, set)  
All  
All  
Tdelay  
Tdelay  
20  
12  
msec  
msec  
Case 2: Input power is applied for at least one  
second and then the On/Off input is set to logic high  
(delay from instant at which Von/Off = 0.9V until Vo  
= 10% of Vo, set)  
Output voltage Rise time (time for Vo to rise from  
10% of Vo, set to 90% of Vo, set)  
All  
All  
Trise  
0.9  
msec  
Output voltage overshoot  
(Io = 80% of Io,max, VI = 48Vdc TA=25°C)  
5
%VO, set  
Vdc  
Output Voltage Remote Sense  
1.2, 1.5,  
1.8Vdc  
0.25  
10  
2.5, 3.3,  
5.0 Vdc  
%VO, set  
Output Overvoltage Protectionn (Clamp)  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5V dc  
3.3 Vdc  
5.0 Vdc  
All  
VO, limit  
VO, limit  
VO, limit  
VO, limit  
VO, limit  
VO, limit  
Tref  
2.0  
2.3  
2.3  
3.1  
4.0  
6.1  
125  
2.8  
3.2  
3.2  
3.7  
4.6  
7.0  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
°C  
Overtemperature Protection  
(See thermal section)  
Input Undervoltage Lockout  
Turn-on Threshold  
Turn-off Threshold  
All  
All  
32  
27  
36  
Vdc  
Vdc  
25  
LINEAGE POWER  
5
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves  
The following figures provide typical characteristics for the EQW025A0P1 (1.2V, 25A) at 25ºC. The figures are  
identical for either positive or negative Remote On/Off logic.  
27  
24  
21  
18  
15  
12  
9
86  
84  
82  
80  
78  
76  
74  
72  
70  
NC  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
Vin=75V  
Vin=48V  
Vin=36V  
6
3
0
0
5
10  
15  
2 0  
2 5  
20  
30  
40  
50  
60  
70  
80  
90  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 1. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 4. . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 2. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 25A).  
Figure 5. Typical Start-Up with application of Vin (Vin =  
48Vdc, Io = 25A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 3. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 6. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 25A).  
LINEAGE POWER  
6
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves (continued)  
The following figures provide typical characteristics for the EQW025A0M (1.5V, 25A) at 25ºC. The figures are  
identical for either positive or negative Remote On/Off logic.  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
27  
24  
21  
18  
15  
12  
9
NC  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
Vin=75V  
6
Vin=48V  
Vin=36V  
3
0
0
5
10  
15  
20  
25  
20  
30  
40  
50  
60  
70  
80  
90  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 7. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 10. . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 8. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 25A).  
Figure 11. Typical Start-Up with application of Vin (Vin  
= 48Vdc, Io = 25A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 9. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 12. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 25A).  
LINEAGE POWER  
7
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves (continued)  
The following figures provide typical characteristics for the EQW025A0Y (1.8V, 25A) at 25ºC. The figures are  
identical for either positive or negative Remote On/Off logic.  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
27  
24  
21  
18  
15  
12  
9
NC  
Vin=75V  
Vin=48V  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
6
Vin=36V  
3
0
0
5
10  
15  
20  
25  
20  
30  
40  
50  
60  
70  
80  
90  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 13. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 16. . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 14. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 25A).  
Figure 17. Typical Start-Up with application of Vin (Vin  
= 48Vdc, Io = 25A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 15. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 18. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 25A).  
LINEAGE POWER  
8
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves (continued)  
The following figures provide typical characteristics for the EQW023A0G (2.5V, 23A) at 25ºC. The figures are  
identical for either positive or negative Remote On/Off logic.  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
24  
21  
18  
15  
12  
9
NC  
10 0 L F M  
Vin=75V  
Vin=48V  
Vin=36V  
200 LFM  
300 LFM  
6
3
400 LFM  
0
20  
30  
40  
50  
60  
70  
80  
90  
0
5
10  
15  
2 0  
2 5  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 19. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 22. . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 20. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 23A).  
Figure 23. Typical Start-Up with application of Vin (Vin  
= 48Vdc, Io = 23A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 21. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 24. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 23A).  
LINEAGE POWER  
9
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves (continued)  
The following figures provide typical characteristics for the EQW020A0F (3.3V, 20A) at 25ºC. The figures are identical  
for either positive or negative Remote On/Off logic.  
22  
91  
20  
88  
18  
16  
85  
14  
82  
79  
12  
10  
Vin=75V  
NC  
8
Vin=48V  
10 0 LF M  
76  
73  
70  
6
4
2
0
Vin=36V  
200 LFM  
300 LFM  
400 LFM  
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 25. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 28 . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 26. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 20A).  
Figure 29. Typical Start-Up with application of Vin (Vin  
= 48Vdc, Io = 20A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 27. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 30. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 20A).  
LINEAGE POWER  
10  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Characteristic Curves (continued)  
The following figures provide typical characteristics for the EQW012A0A (5.0V, 12A) at 25ºC. The figures are  
identical for either positive or negative Remote On/Off logic.  
94  
91  
88  
85  
82  
79  
76  
73  
70  
14  
12  
10  
8
NC  
10 0 L F M  
200 LFM  
300 LFM  
400 LFM  
6
Vin=75V  
Vin=48V  
Vin=36V  
4
2
0
20  
30  
40  
50  
60  
70  
80  
90  
0
3
6
9
12  
OUTPUT CURRENT, Io (A)  
AMBIENT TEMPERATURE, TA OC  
Figure 31. Typical Converter Efficiency Vs. Output  
current at Room Temperature.  
Figure 34 . Derating Output Current versus Local  
Ambient Temperature and Airflow  
TIME, t (5ms/div)  
TIME, t (1μs/div)  
Figure 32. Typical Output Ripple and Noise (Vin  
=48Vdc, Io = 12A).  
Figure 35. Typical Start-Up with application of Vin (Vin  
= 48Vdc, Io = 12A).  
TIME, t (100μs/div)  
TIME, t (5ms/div)  
Figure 33. Typical Transient Response to Dynamic  
Load change Load from 50% to 75% to 50% of Full  
load at 48 Vdc Input.  
Figure 36. Typical Start-Up Using Remote On/Off,  
negative logic version shown (Vin = 48Vdc, Io = 12A).  
LINEAGE POWER  
11  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
stability of the unit. Consult the factory for further  
application guidelines.  
Test Configurations  
CURRENT PROBE  
TO OSCILLOSCOPE  
Safety Considerations  
LTEST  
VIN(+)  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and  
separation requirements of the end-use safety agency  
standard, i.e., UL60950-1, CSA C22.2 No. 60950-1-  
03 and VDE 0805 (IEC60950, 3rd Ed).  
12μH  
CS 220μF  
E.S.R.<0.1Ω  
33μF  
E.S.R.  
<0.1Ω  
100kH
@ 20°C 100kHz  
@
These converters have been evaluated to the spacing  
requirements for Basic Insulation, per the above  
safety standards; and 1500Vdc is applied from Vin to  
VIN(-)  
NOTE: Measure input reflected ripple current with a simulated  
source inductance (LTEST) of 12μH. Capacitor CS offsets  
possible battery impedance. Measure current as shown  
above.  
Vout to 100% of outgoing production..  
For end products connected to –48V dc, or –60Vdc  
nominal DC MAINS (i.e. central office dc battery  
plant), no further fault testing is required. *Note: -60V  
dc nominal battery plants are not available in the U.S.  
or Canada.  
Figure 37. Input Reflected Ripple Current Test  
Setup.  
COPPERSTRIP  
For all input voltages, other than DC MAINS, where  
the input voltage is less than 60V dc, if the input  
meets all of the requirements for SELV, then:  
VO(+)  
VO(–)  
RESISTIV E  
LO AD  
1uF  
.
10uF  
SC O PE  
The output may be considered SELV. Output  
voltages will remain within SELV limits even with  
internally-generated non-SELV voltages. Single  
component failure and fault tests were performed  
in the power converters.  
GROUND PLANE  
NOTE: All voltage measurements to be taken at the module  
terminals, as shown above. If sockets are used then  
Kelvin connections are required at the module terminals  
to avoid measurement errors due to socket contact  
resistance.  
One pole of the input and one pole of the output  
are to be grounded, or both circuits are to be kept  
floating, to maintain the output voltage to ground  
voltage within ELV or SELV limits.  
Figure 38. Output Ripple and Noise Test Setup.  
For all input sources, other than DC MAINS, where  
the input voltage is between 60 and 75V dc  
(Classified as TNV-2 in Europe), the following must  
be adhered to, if the converter’s output is to be  
evaluated for SELV:  
Rdistribution Rcontact  
Rcontact Rdistribution  
VIN(+)  
VO  
RLOAD  
The input source is to be provided with reinforced  
insulation from any hazardous voltage, including  
the AC mains.  
VO  
VIN  
Rdistribution Rcontact  
Rcontact Rdistribution  
One Vi pin and one Vo pin are to be reliably  
earthed, or both the input and output pins are to  
be kept floating.  
VIN(-)  
COM  
NOTE: All voltage measurements to be taken at the module  
terminals, as shown above. If sockets are used then  
Kelvin connections are required at the module terminals  
to avoid measurement errors due to socket contact  
resistance.  
Another SELV reliability test is conducted on the  
whole system, as required by the safety  
agencies, on the combination of supply source  
and the subject module to verify that under a  
single fault, hazardous voltages do not appear at  
the module’s output.  
Figure 39. Output Voltage and Efficiency Test  
Setup.  
VO. IO  
Efficiency  
=
x
100 %  
η
VIN. IIN  
The power module has ELV (extra-low voltage)  
outputs when all inputs are ELV.  
Design Considerations  
The power module should be connected to a low  
ac-impedance source. A highly inductive source  
impedance can affect the stability of the power  
module. For the test configuration in Figure 37, a  
33μF electrolytic capacitor (ESR<0.7Ω at 100kHz),  
mounted close to the power module helps ensure the  
All flammable materials used in the manufacturing of  
these modules are rated 94V-0, and UL60950 A.2 for  
reduced thickness. The input to these units is to be  
provided with a maximum 6A time- delay in the  
unearthed lead.  
LINEAGE POWER  
12  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
The amount of power delivered by the module is  
defined as the voltage at the output terminals  
multiplied by the output current. When using remote  
sense and trim, the output voltage of the module can  
be increased, which at the same output current would  
increase the power output of the module. Care should  
be taken to ensure that the maximum output power of  
the module remains at or below the maximum rated  
power (Maximum rated power = Vo,set x Io,max).  
Feature Description  
Remote On/Off  
Two remote on/off options are available. Positive logic  
turns the module on during a logic high voltage on the  
ON/OFF pin, and off during a logic low. Negative logic  
remote On/Off, device code suffix “1”, turns the  
module off during a logic high and on during a logic  
low.  
To turn the power module on and off, the user must  
supply a switch (open collector or equivalent) to  
control the voltage (Von/off) between the ON/OFF  
terminal and the VIN(-) terminal (Figure 40). Logic low  
is –0.7V Von/off 1.2V. The maximum Ion/off during  
a logic low is 1mA, the switch should be maintain a  
logic low level while sinking this current.  
SENSE(+)  
SENSE(–)  
VI(+)  
VI(-)  
VO(+)  
VO(–)  
IO  
SUPPLY  
LOAD  
II  
CONTACT  
RESISTANCE  
CONTACT AND  
DISTRIBUTION LOSSES  
During a logic high, the typical Von/off generated by the  
module is 15V, and the maximum allowable leakage  
current at Von/off = 15V is 10μA.  
Figure 41. Effective Circuit Configuration for  
remote sense operation.  
If not using the remote on/off feature:  
For positive logic, leave the ON/OFF pin open.  
For negative logic, short the ON/OFF pin to VIN(-).  
Output Voltage Set-Point Adjustment (Trim)  
Trimming allows the output voltage set point to be  
increased or decreased, this is accomplished by  
connecting an external resistor between the TRIM pin  
and either the VO(+) pin or the VO(-) pin (COM pin) .  
VIN(+)  
VO  
Ion/off  
VIN(+)  
VO(+)  
VOTRIM  
VO(-)  
ON/OFF  
Rtrim-up  
Von/off  
COM  
ON/OFF  
LOAD  
VIN(-)  
Rtrim-down  
VIN(-)  
Figure 40. Circuit configuration for using Remote  
On/Off Implementation.  
Figure 42. Circuit Configuration to Trim Output  
Voltage.  
Remote Sense  
Remote sense minimizes the effects of distribution  
losses by regulating the voltage at the remote-sense  
connections (See Figure 41). The voltage between  
the remote-sense pins and the output terminals must  
not exceed the output voltage sense range given in  
the Feature Specifications table:  
Connecting an external resistor (Rtrim-down) between  
the TRIM pin and the Vo(-) (or Sense(-)) pin  
decreases the output voltage set point. To maintain  
set point accuracy, the trim resistor tolerance should  
be ±0.1%.  
The following equation determines the required  
external resistor value to obtain a percentage output  
voltage change of Δ%  
[VO(+) – VO(–)] – [SENSE(+) – SENSE(–)] 0.5 V  
Although the output voltage can be increased by both  
the remote sense and by the trim, the maximum  
increase for the output voltage is not the sum of both.  
The maximum increase is the larger of either the  
remote sense or the trim.  
LINEAGE POWER  
13  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Alternative voltage programming for output  
voltage: 1.2V (-V Option)  
Feature Description (Continued)  
Output Voltage Set-Point Adjustment (Trim)  
(Continued)  
An alternative set of trimming equations is available  
as an option for 1.0V and 1.2V output modules, by  
ordering the –V option. These equations will reduce  
the resistance of the external programming resistor,  
making the impedance into the module trim pin lower  
for applications in high electrical noise applications.  
For output voltage: 1.2 V to 12V  
510  
100  
Rtrim down =  
10.2 ΚΩ  
Rtrim down  
=
2 ΚΩ  
Δ%  
Δ %  
Where  
100  
R trim  
=
ΚΩ  
up  
Vo, set Vdesired ⎞  
Δ% = ⎜  
⎟×100  
Δ %  
Vo, set  
Vdesired Vo, set  
Where  
Δ% =  
× 100  
Vo, set  
For example, to trim-down the output voltage of 2.5V  
module (EQW023A0G1) by 8% to 2.3V, Rtrim-down  
is calculated as follows:  
For example, to trim-up the output voltage of 1.2V  
module (EQW025A0P/P1-V) by 5% to 1.26V, Rtrim-up  
is calculated is as follows:  
Δ% = 8  
Δ% = 5  
510  
8
100  
5
Rtrim down =  
10.2 ΚΩ  
R trim  
=
ΚΩ  
up  
Rtrim down = 53.55ΚΩ  
Rtrim up = 20.0ΚΩ  
Connecting an external resistor (Rtrim-up) between the  
TRIM pin and the VO(+) (or Sense (+)) pin increases  
the output voltage set point. The following equations  
determine the required external resistor value to  
obtain a percentage output voltage change of Δ%:  
The value of the external trim resistor for the optional  
–V 1.2V module is only 20% of the value required with  
the standard trim equations.  
At 48Vin (+/- 2.5V), EQW series modules can be trim  
down to 20% over the entire temperature range. This  
allows for margining the unit during manufacturing  
process if the set point voltage is lower than the  
standard output voltage. Please consult your local  
Lineage Power field application engineer for  
additional details.  
For output voltage: 1.5 V to 12V  
5.1×Vo, set ×(100 + Δ%)  
1.225×Δ%  
510  
Rtrim up =  
10.2 ΚΩ  
Δ%  
The voltage between the Vo(+) and Vo(–) terminals  
must not exceed the minimum output overvoltage  
protection value shown in the Feature Specifications  
table. This limit includes any increase in voltage due  
to remote-sense compensation and output voltage  
set-point adjustment trim.  
For output voltage: 1.2  
5.1×Vo, set ×(100 + Δ%)  
510  
Rtrim up =  
10.2 ΚΩ  
0.6×Δ%  
Δ%  
Although the output voltage can be increased by both  
the remote sense and by the trim, the maximum  
increase for the output voltage is not the sum of both.  
The maximum increase is the larger of either the  
remote sense or the trim. The amount of power  
delivered by the module is defined as the voltage at  
the output terminals multiplied by the output current.  
When using remote sense and trim, the output  
voltage of the module can be increased, which at the  
same output current would increase the power output  
of the module. Care should be taken to ensure that  
the maximum output power of the module remains at  
or below the maximum rated power (Maximum rated  
power = Vo,set x Io,max).  
Where  
Vdesired Vo, set ⎞  
Δ% = ⎜  
⎟×100  
Vo, set  
For example, to trim-up the output voltage of 1.5V  
module (EQW025A0M1) by 6% to 1.59V, Rtrim-up is  
calculated is as follows:  
Δ% = 6  
5.1×1.5×(100 + 6) 510  
1.225×6  
Rtrim up = 15.12ΚΩ  
Rtrim up =  
10.2 ΚΩ  
6
LINEAGE POWER  
14  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
operation this temperature should not exceed 115 oC.  
The output power of the module should not exceed  
the rated power for the module (Vo, set x Io, max).  
Feature Description (Continued)  
Overcurrent Protection  
Tref  
To provide protection in a fault (output overload)  
condi¬tion, the module is equipped with internal  
current-limiting circuitry, and can endure current  
limiting continuously. At the instance of current-limit  
inception, the output current begins to tail-out. When  
an overcurrent condition exists beyond a few  
seconds, the module enters a “hiccup” mode of  
opera¬tion, whereby it shuts down and automatically  
attempts to restart upon cooling. While the fault  
condition exists, the module will remain in this hiccup  
mode, and can remain in this mode until the fault is  
cleared. The unit operates normally once the output  
current is reduced back into its specified range.  
Air Flow  
Figure 43. Tref Temperature Measurement  
Location.  
Output Over Voltage Protection  
The output overvoltage protection clamp consists of  
control circuitry, independent of the primary regulation  
loop, that monitors the voltage on the output  
terminals. This control loop has a higher voltage set  
point than the primary loop (See the overvoltage  
clamp values in the Feature Specifications Table). In  
a fault condition, the overvoltage clamp ensures that  
the output voltage does not exceed Vo,ovsd, max.  
This provides a redundant voltage-control that  
reduces the risk of output overvoltage.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. Derating figures showing the  
maximum output current that can be delivered by  
each module versus local ambient temperature (TA)  
for natural convection and up to 2m/s (400 ft./min) are  
shown in the respective Characteristics Curves  
section.  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module  
will begin to operate at an input voltage between the  
undervoltage lockout limit and the minimum operating  
input voltage.  
Overtemperature Protection  
To provide protection under certain fault conditions,  
the unit is equipped with a thermal shutdown circuit.  
The unit will shutdown if the thermal reference point  
Tref (Figure 43), exceeds 125oC (typical), but the  
thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating.  
The module will automatically restarts after it cools  
down.  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
The thermal reference point, Tref used in the  
specifications is shown in Figure 43. For reliable  
LINEAGE POWER  
15  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
EMC Considerations  
The figure 44 shows a suggested configuration to  
Layout Considerations  
meet the conducted emission limits of EN55022 Class  
B.  
Copper paths must not be routed beneath the power  
module mounting inserts. Recommended SMT layout  
shown in the mechanical section are for reference  
only. SMT layout depends on the end PCB  
configuration and the location of the load. For  
additional layout guide-lines, refer to FLTR100V10  
data sheet or contact your local Lineage Power field  
application engineer.  
Ld1  
Vin+  
Vin-  
Vout+  
Vout-  
CY1  
CX1  
CX5  
CX3  
EQW  
CX4  
CX2  
CY2  
LC1  
Cim  
Figure 44. Suggested Input Filter Configuration  
for EN55022 Class B.  
Filter components:  
Cx1: 47uF aluminum electrolytic, 100V (Nichicon PW series)  
Cx2: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)  
Cx3: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)  
Cx4: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)  
Cx5: 100uF aluminum electrolytic, 100V (Nichicon PW  
series)  
Cy3, Cy4: 3300pF ceramic, 1500V (AVX  
1812SC332MAT1A)  
Cim: 3300pF ceramic, 1500V (AVX 1812SC332MAT1A)  
Lc1: 768 uH, 4.7A (Pulse Engineering P0422)  
Ld1: 4.7 uH, 5.5A (Vishay IHLP-2525CZ)  
Level [dBµV]  
80  
70  
EN55022 Class B Conducted Average dBuV  
60  
50  
+
40  
30  
20  
10  
0
150k 300k 500k  
1M  
2M 3M 4M5M 7M 10M  
30M  
Frequency [Hz]  
Figure 45. EMC signature using recommended  
filter.  
For further information on designing for EMC  
compliance, please refer to the FLTR100V10 data  
sheet (FDS01-043EPS).  
LINEAGE POWER  
16  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Mechanical Outline for Through-Hole Module  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)  
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]  
Top View  
Side View  
* OPTIONAL PIN LENGTHS SHOWN IN TABLE 2 DEVICE OPTIONS  
Bottom View  
Pin Function  
1
2
3
4
5
6
7
8
VI(+)  
On/Off  
VI(-)  
Vo(-)  
Sense(-)  
Trim  
Sense(+)  
Vo(+)  
LINEAGE POWER  
17  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Mechanical Outline for Surface Mount Power module.  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)  
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]  
Top View  
Side View  
Bottom View  
Pin Function  
1
2
3
4
5
6
7
8
VI(+)  
On/Off  
VI(-)  
Vo(-)  
Sense(-)  
Trim  
Sense(+)  
Vo(+)  
LINEAGE POWER  
18  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Recommended Pad Layout for Surface-Mount Modules  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)  
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]  
Low Current  
High Current  
1
.
0
LINEAGE POWER  
19  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Recommended Pad Layout for Through-Hole modules  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)  
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]  
Component side  
view  
LINEAGE POWER  
20  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Packaging Details  
Tray Specification  
The surface mount versions of the EQW surface  
mount modules (suffix –S) are supplied as standard in  
the plastic tray shown in Figure 46. The tray has  
external dimensions of 135.1mm (W) x 321.8mm (L) x  
12.42mm (H) or 5.319in (W) x 12.669in (L) x 0..489in  
(H).  
Material  
Antistatic coated PVC  
1012Ω/sq  
Max surface resistivity  
Color  
Clear  
Capacity  
12 power modules  
48 pcs (1box of 4 full  
Min order quantity  
trays)  
Each tray contains a total of 12 power modules. The  
trays are self-stacking and each shipping box will  
contain 4 full trays plus one empty hold down tray  
giving a total number of 48 power modules.  
Figure 46. Surface Mount Packaging Tray.  
LINEAGE POWER  
21  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
relatively large mass when compared with  
Through-Hole Soldering Information  
conventional smt components. Variables such as  
nozzle size, tip style, vacuum pressure and placement  
speed should be considered to optimize this process.  
The RoHS-compliant through-hole products use the  
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant  
components. They are designed to be processed  
through single or dual wave soldering machines. The  
pins have an RoHS-compliant finish that is compatible  
with both Pb and Pb-free wave soldering processes.  
A maximum preheat rate of 3°C/s is suggested. The  
wave preheat process should be such that the  
temperature of the power module board is kept below  
210°C. For Pb solder, the recommended pot  
The minimum recommended nozzle diameter for  
reliable operation is 6mm. The maximum nozzle outer  
diameter, which will safely fit within the allowable  
component spacing, is 9 mm. Oblong or oval nozzles  
up to 11 x 9 mm may also be used within the space  
available.  
For further information please contact your local  
Lineage Power Technical Sales Representative.  
temperature is 260°C, while the Pb-free solder pot is  
270°C max. Not all RoHS-compliant through-hole  
products can be processed with paste-through-hole  
Pb or Pb-free reflow process. If additional information  
is needed, please consult with your Lineage Power  
representative for more details.  
Reflow Soldering Information  
The surface mountable modules in the EQW family  
use our newest SMT technology called “Column Pin”  
(CP) connectors. Figure 48 shows the new CP  
connector before and after reflow soldering onto the  
end-board assembly.  
Surface Mount Information  
Pick and Place  
EQW Board  
The SMT versions of the EQW series of DC-to-DC  
power converters use an open-frame construction and  
are designed for surface mount assembly within a  
fully automated manufacturing process.  
Insulator  
The EQW-S series modules are fitted with a Kapton  
label designed to provide a large flat surface for pick  
and placing. The label is located covering the center  
of gravity of the power module. The label meets all  
the requirements for surface-mount processing, as  
well as meeting UL safety agency standards. The  
label will withstand reflow temperatures up to 300°C.  
The label also carries product information such as  
product code, date and location of manufacture.  
Solder Ball  
End assembly PCB  
Figure 48. Column Pin Connector Before and After  
Reflow Soldering .  
The CP is constructed from a solid copper pin with an  
integral solder ball attached, which is composed of  
tin/lead (Sn63/Pb37) solder for non-Z codes, or  
Sn/Ag3.8/Cu0.7 (SAC) solder for –Z codes. The CP  
connector design is able to compensate for large  
amounts of co-planarity and still ensure a reliable  
SMT solder joint. Typically, the eutectic solder melts  
at 183oC (Sn/Pb solder) or 217-218 oC (SAC solder),  
wets the land, and subsequently wicks the device  
connection. Sufficient time must be allowed to fuse  
the plating on the connection to ensure a reliable  
solder joint. There are several types of SMT reflow  
technologies currently used in the industry. These  
surface mount power modules can be reliably  
soldered using natural forced convection, IR (radiant  
infrared), or a combination of convection/IR.  
Figure 47. Pick and Place Location.  
Z plane Height  
The following instructions must be observed when  
SMT soldering these units. Failure to observe these  
instructions may result in the failure of or cause  
damage to the modules, and can adversely affect  
long-term reliability.  
The ‘Z’ plane height of the pick and place label is 9.15  
mm (0.360 in) nominal with an RSS tolerance of +/-  
0.25 mm.  
Nozzle Recommendations  
The module weight has been kept to a minimum by  
using open frame construction. Even so, they have a  
LINEAGE POWER  
22  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Nonhermetic Solid State Surface Mount Devices) for  
both Pb-free solder profiles and MSL classification  
procedures. This standard provides a recommended  
forced-air-convection reflow profile based on the  
volume and thickness of the package (table 4-2). The  
suggested Pb-free solder paste is Sn/Ag/Cu (SAC).  
The recommended linear reflow profile using  
Sn/Ag/Cu solder is shown in Fig. 51.  
Surface Mount Information (continued)  
Tin Lead Soldering  
The recommended linear reflow profile using Sn/Pb  
solder is shown in Figure 49 and 50. For reliable  
soldering the solder reflow profile should be  
established by accurately measuring the modules CP  
connector temperatures.  
300  
Per J-STD-020 Rev. C  
Peak Temp 260°C  
300  
250  
Peak Temp 235oC  
Cooling  
200  
250  
Zone  
* Min. Time Above 235°C  
Cooling  
zone  
1- 4 oCs-1  
15 Seconds  
Heat zone  
max 4oCs-1  
150  
200  
150  
10 0  
50  
Heating Zone  
*Time Above 217°C  
1°C/Second  
60 Seconds  
100  
50  
0
Soak zone  
30-240s  
T
lim above  
205oC  
Reflow Time (Seconds)  
Preheat zone  
max 4oCs-1  
Figure 51. Recommended linear reflow profile  
using Sn/Ag/Cu solder.  
0
REFLOW TIME (S)  
MSL Rating  
Figure 49. Recommended Reflow Profile for Sn/Pb  
Solder.  
The EQW series SMT modules have a MSL rating of  
2.  
240  
235  
230  
225  
220  
215  
210  
205  
200  
Storage and Handling  
The recommended storage environment and handling  
procedures for moisture-sensitive surface mount  
packages is detailed in J-STD-033 Rev. A (Handling,  
Packing, Shipping and Use of Moisture/Reflow  
Sensitive Surface Mount Devices). Moisture barrier  
bags (MBB) with desiccant are required for MSL  
ratings of 2 or greater. These sealed packages  
should not be broken until time of use. Once the  
original package is broken, the floor life of the product  
at conditions of 30°C and 60% relative humidity  
varies according to the MSL rating (see J-STD-033A).  
The shelf life for dry packed SMT packages will be a  
minimum of 12 months from the bag seal date, when  
stored at the following conditions: < 40° C, < 90%  
relative humidity.  
0
10  
20  
30  
40  
50  
60  
TIME LIMIT (S)  
Figure 50. Time Limit, Tlim, Curve Above 205oC  
Reflow .  
Lead Free Soldering  
Post Solder Cleaning and Drying  
Considerations  
The –Z version SMT modules of EQW series are  
lead-free (Pb-free) and RoHS compliant and are  
compatible in a Pb-free soldering process. Failure to  
observe the instructions below may result in the  
failure of or cause damage to the modules and can  
adversely affect long-term reliability.  
Post solder cleaning is usually the final circuit-board  
assembly process prior to electrical board testing. The  
result of inadequate cleaning and drying can affect  
both the reliability of a power module and the  
testability of the finished circuit-board assembly. For  
guidance on appropriate soldering, cleaning and  
drying procedures, refer to Lineage Power Board  
Mounted Power Modules: Soldering and Cleaning  
Application Note (AN04-001).  
Pb-free Reflow Profile  
Power Systems will comply with J-STD-020 Rev. C  
(Moisture/Reflow Sensitivity Classification for  
LINEAGE POWER  
23  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Ordering Information  
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.  
Table 1. Device Codes  
Output  
Voltage  
Output  
Current  
Connector  
Type  
Product codes  
Input Voltage  
Efficiency  
Comcodes  
108981960  
EQW025A0P1  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
48V (36-75Vdc)  
1.2 V  
1.2 V  
1.5 V  
1.8 V  
2.5V  
25 A  
25 A  
25 A  
25 A  
23 A  
20 A  
12 A  
23 A  
20 A  
12 A  
25 A  
25 A  
25 A  
20 A  
12 A  
25 A  
25 A  
20 A  
12 A  
81.0 %  
81.0 %  
81.0 %  
84.0 %  
87.0 %  
88.0 %  
91.0 %  
87.0 %  
88.0 %  
91.0 %  
81.0 %  
81.0 %  
84.0 %  
88.0 %  
91.0 %  
81.0 %  
81.0 %  
88.0 %  
91.0 %  
Through hole  
Through hole  
Through hole  
Through hole  
Through hole  
Through hole  
Through hole  
SMT  
EQW025A0P1-V  
EQW025A0M1  
EQW025A0Y1  
CC109120763  
108980632  
108981978  
108980624  
108981952  
108984444  
108980921  
108980905  
108980889  
CC109107083  
CC109107067  
CC109107091  
CC109107050  
CC109104972  
109100187  
109100204  
109100170  
109100162  
EQW023A0G1  
EQW020A0F1  
3.3 V  
5.0 V  
2.5V  
EQW012A0A1  
EQW023A0G1-S  
EQW020A0F1-S  
EQW012A0A1-S  
EQW025A0P1Z  
EQW025A0M1Z  
EQW025A0Y1Z  
EQW020A0F1Z  
EQW012A0A1Z  
EQW025A0P1-SZ  
EQW025A0M1-SZ  
EQW020A0F1-SZ  
EQW012A0A1-SZ  
3.3 V  
5.0 V  
1.2 V  
1.5 V  
1.8 V  
3.3 V  
5.0 V  
1.2 V  
1.5 V  
3.3 V  
5.0 V  
SMT  
SMT  
Through hole  
Through hole  
Through hole  
Through hole  
Through hole  
SMT  
SMT  
SMT  
SMT  
LINEAGE POWER  
24  
Data Sheet  
EQW012/020/023/025 Series, Eighth-Brick Power Modules:  
36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output  
December 12, 2008  
Table 2. Device Options  
Option  
Suffix*  
Negative remote on/off logic  
1
6
Short Pins: 3.68 mm ± 0.25 mm (0.145 in ±0.010 in)  
Short Pins: 2.79 mm ± 0.25 mm (0.110 in ±0.010 in)  
Surface mount connections  
8
-S  
-V  
-Z  
Alternative Voltage Programming equations (1.0V and 1.2V modules only)  
RoHS Compliant  
*Note: Legacy device codes may contain a –B option suffix to indicate 100% factory Hi-Pot tested to the isolation voltage specified  
in the Absolute Maximum Ratings table. The 100% Hi-Pot test is now applied to all device codes, with or without the –B option  
suffix. Existing comcodes for devices with the –B suffix are still valid; however, no new comcodes for devices containing the –B  
suffix will be created.  
Asia-Pacific Headquarters  
Tel: +65 6416 4283  
Europe, Middle-East and Africa Headquarters  
World Wide Headquarters  
Tel: +49 89 6089 286  
Lineage Power Corporation  
3000 Skyline Drive, Mesquite, TX 75149, USA  
+1-800-526-7819  
India Headquarters  
(Outside U.S.A.: +1-972-284-2626)  
www.lineagepower.com  
Tel: +91 80 28411633  
e-mail: techsupport1@lineagepower.com  
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or  
application. No rights under any patent accompany the sale of any such product(s) or information.  
© 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.  
Document No: DS03-74 ver. 1.23  
PDF name: eqw_12-25-ds.pdf  

EQW025A0Y1 相关器件

型号 制造商 描述 价格 文档
EQW025A0Y1Z LINEAGEPOWER 36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output 获取价格
EQW030A0F1 LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW030A0F1-HZ LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW030A0F1-SZ LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW030A0F1Z LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW030A0F41Z LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW030A0G1 LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW035A0G1Z LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格
EQW040A0M1-SZ LINEAGEPOWER 36 - 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current 获取价格