DBFE-0100U232-00 [LINKCOM]
0-10V Dimmable;型号: | DBFE-0100U232-00 |
厂家: | LINKCOM MANUFACTURING CO., LTD. |
描述: | 0-10V Dimmable |
文件: | 总5页 (文件大小:530K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
0-10V Dimmable
100-DBFE Series
Constant Current Mode
FEATURES:
● AC Input 100~277 Vac Nominal
● Built-in Active Power Function Correction
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -30 ℃ ~ +50 ℃
● Surge Protection: L-N 6 kV
● Safety: Meets UL
● EMI: FCC / Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years @ T.C < 75 ℃ (refer to LinkCom warranty policy)
● RoHS Compliant
● 0V-10V Dimming
PRODUCT SPECIFICATION
OUTPUT
OUTPUT
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
MODEL
CURRENT
EFFICIENCY O/P NOISE(P-P,V)
CURRENT(A)
TOLERANCE
DBFE-0100U402-00
DBFE-0100U272-00
DBFE-0100U232-00
DBFE-0100U202-00
DBFE-0100U182-00
96
96
96
96
96
15-24
22-36
24-42
26-48
30-54
4
±5%
±5%
±5%
±5%
±5%
88.0%
88.5%
89.0%
89.0%
90.0%
1% Vo(max.)
1% Vo(max.)
1% Vo(max.)
1% Vo(max.)
1% Vo(max.)
2.7
2.3
2
1.8
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
INPUT FREQUENCY
ACTIVE POWER FACTOR
THD
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
Range: 47-63 Hz, Normal: 50-60 Hz
> 0.9 @ Full Load 100-277 Vac
< 20 % at Full Load 100-277 Vac
<1s at Full Load 100-277 Vac
1.5 A / 100 Vac 0.6 A / 277 Vac
Cold Start 65 A @ 230 Vac
TURN ON DELAY TIME
AC CURRENT
INRUSH CURRENT (typ)
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
OPERATING TEMP.
STORAGE TEMP.
<0.75 mA at 277 Vac
SCP and OVP will restart automatically after the fault condition is removed
shut down and latch off o/p voltage , re-power on to recover
-30℃ ~ +50℃ @ Full Load 100-277 Vac
-40℃~+80℃
RELATIVE HUMIDITY
SAFETY
10% to +90%, non-cond.
Meets UL 8750
EMI
FCC Part15 / Meets EN 55015
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
DIMENSION (L*W*H)
I/P-O/P:4242 Vdc, I/P-FG:2121 Vdc
I/P-O/P, I/P-FG,O/P-FG :100M Ω / 500 Vdc / 25℃ / 70% RH
232 * 46.5 * 31 mm【9.13 * 1.83 * 1.22 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
100-DBFE Series
DIMENSIONS
Constant Current Mode
Tc Max.
DBFE-100U402 as Tc Max. Reference
Wiring Digram
Purple
Gray
Dim+
Dim-
Line
Brown
Blue
LED DRIVER
Red
+
-
Neutral
Black
Case ground via mounting tabs
*REFERENCE: www.linkcom.com.tw
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
100-DBFE Series
Constant Current Mode
DIMMING OPERATION
Parameters
Minimum
1V
Typical
─
Maximum
10V
Absolute maximum voltageon on the 1-10(+) Purple Wire
Source current on the 1-10V(+) Purple Wire
0mA
1mA
─
(Leviton) IP710 Dimmer
Purple(+)
V
PDBFE0100■XXX-00G
(Lutron) NTSTV-DV Dimmer
Gray(-)
Red(+)
Black(-)
Output Current / 1-10VDC Dimming Input
100.0%
90.0%
80.0%
70.0%
60.0%
50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
0
1
2
3
4
5
6
7
8
9
10
Dimming Input(VDC)
Notes:
1. Purple and Gray wires on the output side are used for 1-10V dimming.
2. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent.
3. When dimming wires +Purple/-Gray are left open, the output current will be at 100%
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
100-DBFE Series
Constant Current Mode
Power Factor vs. Load (DBFE-100U402-00)
PF vs. Load
1.00
0.95
0.90
0.85
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
Efficiency vs. Load (DBFE-100U402-00)
Efficiency vs. Load
90%
85%
80%
75%
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
T.H.D vs. Load (DBFE-100U402-00)
THD vs. Load
25%
20%
15%
10%
5%
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
0%
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
100-DBFE Series
Constant Current Mode
Output Current vs. Load (DBFE-100U402-00)
Output Current vs. Load
4.100
4.050
4.000
3.950
3.900
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw