0461.500ERT [LITTELFUSE]

Telecom NANO2®Fuse 461 Series and Teccor TeleLink® Fuse; 电信NANO2®Fuse 461系列和的Teccor TeleLink®保险丝
0461.500ERT
型号: 0461.500ERT
厂家: LITTELFUSE    LITTELFUSE
描述:

Telecom NANO2®Fuse 461 Series and Teccor TeleLink® Fuse
电信NANO2®Fuse 461系列和的Teccor TeleLink®保险丝

电信
文件: 总3页 (文件大小:201K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Surface Mount Fuses  
Miniature Surface Mount  
Telecom NANOFuse 461 Series and Teccor TeleLink® Fuse  
®
®
RoHS  
®
• Surface mount surge resistant Slo-Blo fuse.  
• Meets UL 60950 3rd Edition power cross requirements stand  
alone.  
• Designed to allow compliance with Telcordia GR-1089-CORE  
and TIA-968-A (formerly FCC Part 68) Surge Specifications.  
• Provides coordinated protection with Littelfuse SIDACtor®  
Protection Thyristors without series resistors.  
• Ideal for use in telecommunication equipment including line  
cards, modems, fax machines, phones, answering machines,  
caller ID devices and other products connected to phone  
network.  
• 2A rating has improved temperature rise performance under  
Reference Dimensions:  
2.2A surge current testing when compared with 1.25A rating.  
• Product is RoHS Compliant and compatible with lead-free  
solders and higher temperature profiles when ordered with  
Standard Silver Plated Brass Caps.  
3.25  
10.10  
(.128")  
• Standard product is RoHS Compliant and compatible with  
lead-free solders and higher temperature profiles.  
(.397")  
6.10  
(.240")  
3.12  
(.123")  
3.43  
T
F
1.25A  
L
AGENCY APPROVALS: Recognized under the Components  
(.135")  
Program of Underwriters Laboratories and Certified by CSA.  
12.6  
(.496")  
3.12  
(.123")  
Littelfuse:  
UL E10480  
CSA LR29862  
1.70 typ  
(.067")  
Recommended Pad Layout  
Teccor:  
UL E191008  
CSA LR702828  
PHYSICAL SPECIFICATIONS:  
Materials: Body: Ceramic  
RoHS Compliant Terminations: Silver Plated Brass Caps  
Terminations: Tin-Lead Alloy also available, add suffix, T.  
100  
10  
Soldering Parameters:  
Reflow Solder — 230°C, 30 seconds maximum.  
Wave Solder — 260°C, 3 seconds maximum.  
10  
PACKAGING SPECIFICATIONS: 24mm Tape and Reel  
per EIA-RS481-2, (IEC 286 part 3); 2500 fuses per reel,  
add suffix, ER.  
ORDERING INFORMATION:  
Telecom  
Teccor  
2
1
Nano  
TeleLink  
Nominal  
Nominal  
Catalog  
Number  
0461.500  
0461 1.25  
0461 002.  
Catalog Ampere Voltage Resistance Melting I2t  
Number Rating Rating Cold Ohms  
F0500T  
F1250T  
F1251T  
A2 Sec.  
0.5  
1.25  
2.00  
250  
250  
250  
.560  
.110  
.050  
.8401  
16.51  
17.51  
0.1  
0.01  
Notes:  
1 I2t is calculated at 10 msec or less. I2t at 10 times rated current has a typical value of:  
24 A2sec (2.0A), 22 A2sec (1.25A), 1.3 A2sec (0.5A).  
Typical inductance < 40nH up to 500 MHz.  
• Resistance changes 0.5% for every ˚C.  
• Resistance is measured at 10% rated current.  
0.001  
0.1  
1
10  
CURRENT IN AMPERES  
100  
1000  
377  
www. lit t elf us e. c om  
Surface Mount Fuses  
Miniature Surface Mount  
Telecom NANO2® Fuse 461 Series and Teccor TeleLink® Fuse  
®
®
ELECTRICAL CHARACTERISTICS:  
% of AmpereRating  
100%  
Maximum Temperature Rise:  
OpeningTime  
Telecom Nano2 Fuse  
Temperature Reading  
< 82˚C (180˚F)  
04611.25  
0461002.  
4 hours, Min.  
< 50˚C (122˚F)  
250%  
1 Second, Min.; 120 Seconds, Max.  
INTERRUPTING RATINGS:  
50 amperes at 250 VAC.  
Higher Currents and PCB layout designs can affect this parameter.  
Readings are measured at rated current after temperature stabilizes.  
GR 1089 Inter-building requirements  
Temperature Derating Curve  
Operating Temperature is -55˚C to +125˚C with proper correction factor applied  
st  
GR 1089 1 level lighting surge inter-building  
(Equipment under test can not be damaged & must  
continue to operate properly)  
140  
120  
100  
80  
Surge Minimum Minimum  
Max  
Rise/Min.  
Decay  
(µs)  
10/1000  
10/360  
10/1000  
2/10  
Repetitions  
Each  
Fuse  
Peak  
Voltage  
(V)  
Peak  
Current  
(A)  
Choices  
Polarity  
1
2
3
4
5
600  
100  
100  
100  
500  
25  
25  
25  
10  
5
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1000  
1000  
2500  
1000  
1.25, 2.0  
60  
25  
10/360  
0.5, 1.25, 2.0  
If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4.  
40  
nd  
GR 1089 2 level lightning surge telecom port (Equipment  
under test shall not become a fire, fragmentation, or electri-  
cal safety hazard)  
20  
-60°C -40°C -20°C  
-76°F -40°F -4°F  
0°C  
20°C 40°C  
60°C 80°C 100°C 120°C  
Surge  
Minimum Minimum  
Max  
Rise/Min.  
Decay  
(µs)  
Repetitions  
Each  
Fuse  
32°F 68°F 104°F 140°F 176°F 212°F 248°F  
Peak  
Voltage  
(V)  
5000  
5000  
Peak  
Current  
(A)  
Choices  
AMBIENT TEMPERATURE  
Polarity  
Ambient temperature effects are in addition to the normal derating.  
1
500  
2/10  
1
1
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
alternative  
5000/8=625  
8/20  
The 0.5 fuse will open during these test conditions. The 1.25 & 2.0 will not open thus providing  
operational compliance.  
st  
GR 1089 AC power fault 1 level inter-building  
(fuse not allowed to open)  
Test  
Vrms  
Short  
Circuit  
Current  
(A)  
Duration  
Primary  
Fuse  
Protector  
Choices  
1
2
3
4
5
6
7
8
9
50  
100  
200,400, 600  
1000  
Diagram  
600  
440  
.33  
15 min.  
15 min  
60 x 1 sec. removed  
60 x 1 sec. operative  
removed  
removed  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
1.25, 2.0  
.17  
1
1
Diagram 60 x 5 sec. removed  
0.5  
2.2  
3
30s  
removed  
removed  
removed  
in place  
5 x 2 sec.  
1.1 sec.  
0.4 sec.  
600  
1000  
5
nd  
GR 1089 AC power fault 2 level (fuse can open but must  
open in a safe and controlled manner)  
Test  
Vrms  
Short  
(A)  
Duration  
Fuse  
Circuit  
1
2
3
4
5
120, 277  
600  
600  
100-600  
Diagram  
25  
15 min.  
5 sec.  
5 sec.  
15 min..  
15 min.  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
60  
7
2.2  
Diagram  
Fuse must open before wiring simulator fuse (MDL 2.0).  
378  
www. littelfuse. com  
Surface Mount Fuses  
Miniature Surface Mount  
Telecom NANO2® Fuse 461 Series and Teccor TeleLink® Fuse  
®
®
TIA 968-A (formerly FCC Part 68) Surge Waveforms  
(fuse can not open during type B events)  
Surge  
Voltage Waveform Current Waveform  
Reps  
Recommended  
(V)  
(µs)  
(A)  
100  
200  
25  
(µs)  
Fuse  
1.25  
1.25  
1.25  
1.25  
Metallic A  
800  
10 x 560  
10 x 160  
9 x 720  
9 x 720  
10 x 560  
10 x 160  
5 x 320  
5 x 320  
1 ea. polarity  
1 ea. polarity  
1 ea. polarity  
1 ea. polarity  
Longitudinal A 1500  
Metallic B  
1000  
Longitudinal B 1500  
37.5  
For the type A events the 0.5 fuse will open, providing non-operational compliance. The 1.25 & 2.0 will not open, providing  
for operational compliance with TIA-968-A type A surge events.  
UL 60950 requirements  
UL60950 (EN 60950) (formerly UL 1950) Power  
Cross (L = longitudinal, M = metallic)  
Test  
Number  
L1  
Voltage Current  
Time  
Fuse  
(V)  
(A)  
40  
7
Choices  
600  
600  
600  
200  
120  
600  
600  
600  
600  
1.5 sec.  
5 sec.  
30 min.  
30 min.  
30 min.  
1.5 sec.  
5 sec.  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
L2  
L3  
2.2  
2.2  
25  
40  
7
L4  
L5  
M1  
M2  
M3  
2.2  
2.2  
30 min.  
30 min.  
M4  
Selection of test number depends on current limiting & fire enclosure/spacing of  
end product  
26 AWG line cord removes L1/M1 test requirement  
L5 conducted only if product does not pass section 6.1.2  
L2,M2,L3,M3,L4,M4 conducted if not in a fire enclosure  
Fuse must open before the wiring simulator fuse (MDL 2.0).  
UL60950 (EN 60950) (formerly UL 1950)  
Impulse Test & Steady-state electric strength test  
10  
Test  
Voltage Current Waveform  
Repetitions  
Fuse  
(V)  
(A)  
Choices  
Impulse  
For handheld units 2500  
Non handheld  
62.5  
37.5  
10 x 700µs + 10 w/60 sec. rest 0.5, 1.25, 2.0  
10 x 700µs + 10 w/60 sec. rest 0.5, 1.25, 2.0  
1500  
Steady-State  
For handheld units 1500  
60Hz  
60Hz  
0.5, 1.25, 2.0  
0.5, 1.25, 2.0  
Non handheld  
1000  
379  
www. littelfuse. com  

相关型号:

0461002.

Electric Fuse, Slow Blow, 2A, 600VAC, 250VDC, 60A (IR), Surface Mount, ROHS COMPLIANT
LITTELFUSE

0461002.ER

Surface Mount Fuses Surge Resistant > 461 Series TeleLink® Fuse
LITTELFUSE

0461002.ERT

Telecom NANO2®Fuse 461 Series and Teccor TeleLink® Fuse
LITTELFUSE

046101003FAR

SHAFT COLLAR STEEL 1PC
ETC

046101004FAR

SHAFT COLLAR STEEL 1PC
ETC

046101005FAR

SHAFT COLLAR STEEL 1PC
ETC

046101006FAR

SHAFT COLLAR STEEL 1PC
ETC

046101008FAR

SHAFT COLLAR STEEL 1PC
ETC

046101010FAR

SHAFT COLLAR STEEL 1PC
ETC

046101012FAR

SHAFT COLLAR STEEL 1PC
ETC

046101014FAR

SHAFT COLLAR STEEL 1PC
ETC

046101016FAR

SHAFT COLLAR STEEL 1PC
ETC