5904-4-S-02-F [LITTELFUSE]

Press-Fit Firecracker Reed Sensor;
5904-4-S-02-F
型号: 5904-4-S-02-F
厂家: LITTELFUSE    LITTELFUSE
描述:

Press-Fit Firecracker Reed Sensor

文件: 总3页 (文件大小:513K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Reed Sensors  
Firecracker > 59040  
59040 Press-Fit Firecracker Reed Sensor + 57040 Actuator  
Description  
The 59040 Press-Fit Firecracker Reed Sensor is a small, cylindrical reed sensor  
31.0mm (L) x 10.7mm (Dia.) (1.22” x 0.420”) with a choice of normally open,  
normally closed or change-over contacts. It is capable of switching up to 300Vdc  
at 10W and available with a range of sensitivity, cable length and connector  
options. It is well suited for position and limit sensing, security, level sensing and  
linear actuator applications. It functions best with the 57040 actuator.  
Sensor  
Note: The 57040 Actuator is sold separately.  
Actuator  
Features  
• Magnetically-operated proximity  
sensor  
• Cylindrical capsule with retaining  
ribs  
• Operates through non-ferrous  
materials such as wood, plastic or  
aluminum  
• Hermetically sealed contacts  
• Options of normally open, normally  
closed or single-pole-double-throw  
• Customer-defined sensitivity  
• Custom cable length and connector  
options available  
Dimensions  
Dimensions in mm (inch)  
Sensor  
8.46±±.ꢀ2  
(.333±.±01  
Benefits  
• Ribs on capsule compress when  
inserted into a mounting hole and  
provide retaining force, allowing  
simple and secure press-fit  
installation  
• Quick and easy press-fit installation  
that requires no screws, brackets,  
nor glue.  
• Non-contact solution, aesthetically  
more appealing than push-button or  
lever mechanical-type switches  
• Ideal for battery-powered  
applications as the contacts do not  
draw power when in the non-  
activated state  
• Reed contacts last for millions of  
operating cycles under micro-  
controller voltage and current logic-  
level loads  
0±.7± ±±.ꢀ2  
(.4ꢀ ±.±01  
30.±±±±.ꢀ2  
(0.ꢀꢀ±.±01  
3±±  
(00.801  
• Well suited for usage in high-  
moisture and contaminated  
environments  
Actuator  
8.46±±.ꢀ2  
(.333±.±01  
0±.7± ±±.ꢀ2  
(.4ꢀ ±.±01  
30.±±±±.ꢀ2  
(0.ꢀꢀ±.±01  
Applications  
• Position and limit sensing  
• Security  
• Level sensing  
• Linear actuators  
Notes:  
1. The 59040 Sensor and 57040 Actuator are designed to fit into a drill size hole of 9.5mm  
(0.374") diameter.  
2. Not recommended to be mounted within ferrous metal materials, these activate distance  
will decrease significantly.  
© 2015 Littelfuse  
Revised: 11/02/15  
littelfuse.com  
Specifications are subject to change without notice.  
Reed Sensors  
Firecracker > 59040  
59040 Press-Fit Firecracker Reed Sensor + 57040 Actuator  
Electrical Ratings  
Contact Type  
Normally Open  
Change Over  
Normally Closed  
Switch Type  
1
3
5
4
5
Contact Rating 1  
VA/Watt - max.  
10  
Switching 2  
Vdc - max.  
Vac - max.  
Vdc - min.  
200  
140  
250  
175  
120  
200  
175  
120  
200  
Voltage 4  
Current 4  
Breakdown 3  
Switching 2  
Adc - max.  
Aac - max.  
Adc - max.  
0.5  
0.35  
1.2  
0.25  
1.0  
1.5  
0.25  
1.0  
1.5  
Carry  
Contact, Initial  
Insulation  
Ω - max.  
Ω - min.  
0.2  
0.2  
109  
0.2  
109  
Resistance 5  
Capacitance  
Temperature  
1010  
Contact  
pF - typ.  
0.3  
0.3  
0.3  
Operating  
°C  
-40 to +105  
-40 to +105  
-40 to +105  
Product Characteristics  
Operate Time 6  
Release Time 6  
Shock 7  
ms - max.  
ms - max.  
G - max.  
G - max.  
1.0  
1.0  
100  
30  
3.0  
3.0  
50  
3.0  
3.0  
50  
11ms ꢀ sine  
50-2000 Hz  
Vibration 7  
30  
30  
Notes:  
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.  
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.  
3. Breakdown Voltage - per MIL-STD-202, Method 301. Leakage current is less than 0.1mA for 60 seconds.  
4. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.  
5. This resistance value is for 11.81mm wire length. Resistance changes when wire lengthens.  
6. Operate (including bounce)/Release Time - per EIA/NARM RS-421-A, diode suppressed coil (Coil II).  
7. Shock and Vibration - per EIA/NARM RS-421-A and MIL-STD-202.  
8. For custom modifications to the wire length or size, or adding a special connector, please contact Littelfuse.  
9. Custom sensitivity options and a normally open high-voltage switch option are available.  
Sensitivity Options (Using 57040 Actuator)  
Select Option  
S
T
U
Activate Distance  
mm (inch)  
Activate Distance  
mm (inch)  
Activate Distance  
Switch Type  
Pull-In AT Range  
Pull-In AT Range  
Pull-In AT Range  
mm (inch)  
Average  
Average  
Average  
1
3
4
Normally Open  
Change Over  
12-18  
15-20  
15-20  
25.0 (.984)  
21.0 (.836)  
21.0 (.836)  
17-23  
20-25  
20-25  
21.2 (.834)  
18.4 (.725)  
18.4 (.725)  
22-28  
25-30  
25-30  
17.9 (.705)  
17.0 (.670)  
17.0 (.670)  
Normally Closed  
Note:  
1. Pull-In AT Range: These AT values are the bare reed switch AT before modification.  
2. The activate distance is an average value for the final sensor assembly.  
3. Not recommended to be mounted within/near ferrous metal materials; if doing so, these  
activate distances will decrease significantly.  
Schematics  
Switch Type  
Black  
Black  
1
3
4
Actuator  
Sensor  
Black  
Blue  
White  
Black  
Black  
D
© 2015 Littelfuse  
Revised: 11/02/15  
littelfuse.com  
Specifications are subject to change without notice.  
Reed Sensors  
Firecracker > 59040  
59040 Press-Fit Firecracker Reed Sensor + 57040 Actuator  
Cable Length Specification  
Termination Specification  
Cable Type: 24 AWG PVC 105°C UL1430/UL1569  
Termination Options  
Cable Length  
mm (inch)  
Select  
Option  
Description  
(Two-wire versions illustrated)  
Select Option  
02  
300 (11.81)  
A
F
E
Tinned leads (6.4 0.76)mm  
Untinned leads (6.4 0.76)mm  
JST type XHP 2.5mm pitch  
Part Numbering System  
Sensor:  
59040 - X - X - XX - X  
Actuator:  
57040 - 000  
Series  
Series  
SwitchType  
Standard Actuator  
1, 3, or 4  
000  
Note: The 57040 Actuator is sold separately.  
Sensitivity  
S, T, or U  
Cable Length  
02  
Termination  
A, F, or E  
Packaging  
Packaging Option  
Packaging Specification  
Quantity  
Quantity and Packaging Code  
Taping Width  
Bulk  
Bulk  
500  
N/A  
N/A  
© 2015 Littelfuse  
Revised: 11/02/15  
littelfuse.com  
Specifications are subject to change without notice.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
VISHAY