CCMR31/2 [LITTELFUSE]

Fuse;
CCMR31/2
型号: CCMR31/2
厂家: LITTELFUSE    LITTELFUSE
描述:

Fuse

文件: 总3页 (文件大小:634K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Class CC Fuses  
600 VAC 1/10 60 Amperes  
SPECIFICATIONS  
Voltage ratings:AC: 600 Volts  
DC: 250 500 Volts (CCMR)†  
300 Volts (KLDR)  
300 Volts (KLKR)  
Interrupting ratings: AC: 200,000 amperes  
GENERAL  
PURPOSE  
FUSES  
rms symmetrical  
DC: 20,000 amperes  
Ampere range:CCMR: 2/10 60 amperes  
KLDR: 1/10 30 amperes  
KLKR: 1/10 30 amperes  
Approvals: CCMR:2/10 30A: UL Listed Time-Delay  
Class CC fuses  
per UL 248  
(formerly UL 198C)  
(File No. E81895).  
CSA Certified HRCI-MISC  
(File No. LR29862).  
35 60A: UL Listed Class CD fuses  
(File No. E71611).  
CSA Certified  
(File No. LR29862).  
KLDR: UL Listed Time-Delay Class CC fuses  
per UL 198C (File No. E81895)  
CSA Certified HRCI-MISC  
(File No. LR29862)  
KLKR: UL Listed Fast-Acting Class CC fuses  
per UL 198C (File No. E81895)  
Compared to other UL Listed fuses, Class CC fuses are the  
most current limiting, rating for rating. Because they are  
physically compact, they provide this superior protection in a  
fraction of the space required by other fuse classes. For  
example, when 600V three-pole, 30 ampere Class R fuse  
blocks are replaced by Littelfuse Class CC fuse blocks, panel  
mounting space is reduced approximately 70%. This is  
especially important when a panel contains many fuses to  
protect multiple circuit components.  
CSA Certified HRCI-MISC  
(File No. LR29862)  
RECOMMENDED FUSE BLOCKS  
L60030C series  
L60060C series (for CCMR 3560A)  
Refer to Fuse Block section of this catalog for additional  
information.  
APPLICATIONS  
Three Types of Class CC Fuses, Specifically Designed  
to Protect Different Types of Components  
1) Motor protection CCMR series; dual-element, time-  
delay fuses specifically designed to protect motor circuits  
up to 40 HP**.  
Refer to the POWR-PRO® section for additional information.  
2) Small transformer protection (control power  
transformers) KLDR series, time-delay fuses designed  
to withstand the high magnetizing inrush of transformers.  
3) General purpose protection of equipment requiring  
fast overload protection KLKR series, fast-acting  
fuses used for protection of equipment containing solid-  
state devices or other electronic components requiring fast  
response on overloads.  
.25"  
(6.4 mm)  
1.50"  
(38.1 mm)  
.41"  
0-30A  
(10.3 mm)  
.125"  
SAFETY  
(3.2 mm)  
.50"  
200,000 A.I.R. Reliable interruption of all overcurrents up  
to 200,000 amperes.  
(12.7 mm)  
Extremely current limiting Reduces damage caused by  
heating and magnetic effects of short-circuit currents . . .  
stops damaging short-circuit currents faster than any  
mechanical protective device.  
.850 +-.020  
SPACE SAVING  
Class CC fuses are the smallest 600V, 200,000 A.I.R. fuses  
35-60A  
approved for branch circuit protection.  
ECONOMICAL  
Current limiting design often permits use of readily avail-  
1.880 REF.  
able, less costly equipment.  
**Consult the Motor Protection Tables in the Fuseology section for  
specific motor sizing information  
43  
Class CC Fuses  
600 VAC 1/10 60 Amperes  
CCMR Series  
KLDR Series  
KLKR Series  
For space-saving protection of motor cir- For more information on CCMR series  
cuits up to 40 HP**, we recommend  
Littelfuse POWR-PRO® CCMR series  
fuses. These fuses are the only true  
dual-element time-delay CC fuses  
specifically engineered for motor branch  
circuit protection. They provide Type II  
protection (no damage) to both NEMA-  
rated and the more sensitive IEC  
(International Electromechanical Com-  
mission) type motor circuit components.  
CCMR series fuses are now available in  
larger sizes from 35 to 60 amperes!  
No other 600V fuse is available with  
this current carrying capacity in a  
package this small.  
Class CC fuses, see the CCMR series  
pages in the POWR-PRO® section of  
this catalog.  
1/10 30A:UL Listed Time-Delay  
Class CC per UL 198C  
35 60A: UL Listed Class CD  
GENERAL  
PURPOSE  
FUSES  
AMPERE RATINGS  
2
4
10  
11⁄  
4
21⁄  
2
5
9
30  
35  
40  
45  
50  
60  
1
3
1
6
8
1410  
2810  
3
5610  
6
10  
12  
15  
10  
11⁄  
2
2
1610  
1810  
2
3210  
61⁄  
4
10  
31⁄  
2
7
171⁄  
20  
2
10  
4
71⁄  
2
1
21⁄  
4
41⁄  
2
8
25  
Example part number (series &  
amperage): CCMR 30  
**Consult the Motor Protection Tables in the Fuse-  
ology section for specific motor sizing information  
KLDR fuses are time-delay fuses specif-  
ically designed for the protection of con-  
trol transformers, solenoids and similar  
inductive components with high magne-  
tizing currents during the first half-cycle.  
They closely match most control power  
transformer characteristics, which per-  
mits the fuses to be sized in accordance  
with the latest revisions of UL 508  
(Industrial Control) and UL 845 (Motor  
Control Centers). When the time delay  
of KLDR fuses is adequate to carry  
motor starting current, they provide ex-  
cellent protection of motor branch cir-  
cuits containing IEC or NEMA rated  
motor controllers or contactors.  
AMPERE RATINGS  
1
1
8
10  
10  
2
1410  
2810  
3
5610  
10  
12  
15  
1
6
3
8
11⁄  
2
6
15  
100  
4
1610  
1810  
2
3210  
61⁄  
4
3
16  
10  
31⁄  
2
7
171⁄  
20  
25  
30  
2
2
10  
1
4
71⁄  
8
2
1
3
4
4
11⁄  
11⁄  
8
21⁄  
4
41⁄  
2
10  
4
21⁄  
2
5
9
10  
Example part number (series &  
amperage): KLDR 5 610  
KLKR series Class CC fuses are fast-  
acting fuses intended for general pur-  
pose branch circuit protection. Their  
compact size, fast-acting overload  
response, and their highly current limit-  
ing design make them ideal for use in  
OEM equipment and control panels.  
Solid-state devices such as SCRs and  
other electronic equipment generally  
require fast-acting protection.  
AMPERE RATINGS  
1
1
8
10  
4
2
2
4
5
6
7
8
9
10  
12  
15  
20  
25  
30  
1
2
1
3
3
21⁄  
2
10  
1
3
4
11⁄  
2
31⁄  
2
10  
Example part number (series &  
amperage): KLKR 25  
44  
Class CC Fuses  
600 VAC 1/10 60 Amperes  
For performance data on Littelfuse CCMR series Class CC fuses, see the CCMR pages in the POWR-PRO® section of this catalog.  
KLDR  
KLKR  
1000  
800  
600  
1000  
800  
600  
GENERAL  
PURPOSE  
FUSES  
400  
300  
400  
300  
200  
200  
100  
80  
100  
80  
60  
60  
40  
30  
40  
30  
20  
20  
10  
8
10  
8
6
6
4
3
4
3
2
2
1
1
.8  
.8  
.6  
.6  
.4  
.3  
.4  
.3  
.2  
.2  
.1  
.1  
.08  
.08  
.06  
.06  
.04  
.03  
.04  
.03  
.02  
.02  
.01  
.01  
CURRENT IN AMPERES  
CURRENT IN AMPERES  
KLDR  
KLKR  
1000000  
800000  
1000000  
800000  
600000  
600000  
400000  
300000  
400000  
300000  
200000  
200000  
100000  
80000  
100000  
80000  
60000  
60000  
40000  
30000  
40000  
30000  
20000  
20000  
10000  
8000  
10000  
8000  
6000  
6000  
4000  
3000  
4000  
3000  
30A  
25A  
20A  
15A  
10A  
2000  
2000  
8A  
6A  
12A  
4A  
1000  
800  
600  
1000  
800  
600  
400  
300  
400  
300  
200  
200  
100  
100  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
45  

相关型号:

LITTELFUSE

CCMR350

TIME DELAY BLOW ELECTRIC FUSE, 35A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE

CCMR4

Fuse
LITTELFUSE

CCMR4.50

TIME DELAY BLOW ELECTRIC FUSE, 4.5A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE
LITTELFUSE

CCMR400

TIME DELAY BLOW ELECTRIC FUSE, 40A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE
LITTELFUSE

CCMR450

TIME DELAY BLOW ELECTRIC FUSE, 45A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE

CCMR5

Fuse
LITTELFUSE

CCMR5.60

TIME DELAY BLOW ELECTRIC FUSE, 5.6A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE
LITTELFUSE

CCMR500

TIME DELAY BLOW ELECTRIC FUSE, 0.5A, 600VAC, 250VDC, 200000A (IR), INLINE/HOLDER
LITTELFUSE