FS146 [LITTELFUSE]
RELAY TIME DELAY 75FPM CHASSIS;型号: | FS146 |
厂家: | LITTELFUSE |
描述: | RELAY TIME DELAY 75FPM CHASSIS |
文件: | 总2页 (文件大小:262K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Flashers andTower Lighting Controls
Flashers
FS100 SERIES
Low Current Flasher
Description
The FS100 Series (low current) may be used to control inductive,
incandescent or resistive loads. This series offers a 1A (fullwave)
or a 2A (halfwave) steady state, 10A inrush solid-state output
and may be ordered with an input voltage of 24 or 120VAC. The
FS100 Series offers a factory fixed flash rate of 75 FPM or may
be ordered with a fixed, custom flash rate ranging from 45 to
150 FPM. Ideal for OEM applications where cost is a factor.
Operation
Upon application of input voltage, theT2 OFF time begins. At
the end of the OFF time, theT1 ON time begins and the load
energizes. At the end ofT1, T2 begins and the load de-energizes.
This cycle repeats until input voltage is removed.
Reset: Removing input voltage resets the output and the
sequence toT2.
Features & Benefits
FEATURES
Wiring Diagram
BENEFITS
L1
N
Compact Size:
Ideal for OEM applications
V = Voltage
L = Load
R = Red Wire
B = Black Wire
38 x 23.9mm (1.5” x 0.94”)
Custom Flash
Rates Available
Tailor to specific application: custom rates range
from 45 to 150 FPM
Accessories
P1023-2 “P” Clamp
Mounting Bracket Alum. 15/16
Ordering Information
MODEL
INPUT VAC
OUTPUT RATING A
OUTPUT TYPE AC LOAD TYPE
FLASH RATE
FS126
120
1
1
1
1
1
2
1
1
Fullwave
Incandescent & Resistive
Incandescent & Resistive
75 FPM
45 FPM
60 FPM
75 FPM
45 FPM
75 FPM
75 FPM
75 FPM
FS126-45
FS126-60
FS126RC
FS126RC-45
FS127
120
Fullwave
Fullwave
Fullwave
Fullwave
Halfwave
Fullwave
Fullwave
120
Incandescent & Resistive
120
Incandescent, Resistive, & Inductive
Incandescent, Resistive, & Inductive
Incandescent & Resistive
120
120
FS146
24
Incandescent & Resistive
Specifications
Incandescent, Resistive, & Inductive
FS146RC
24
If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/fs100Lowcurrent
Rev: 1-A-062116
Flashers andTower Lighting Controls
Flashers
FS100 SERIES
Specifications
Flasher Function Diagram
Technical Data
V = Voltage
R = Reset
FLASHER (OFF FIRST)
Operation
Flash Rate
OFF/ON solid-state flasher (continuous duty)
Factory fixed at 75 FPM 20%
L = Load
Custom Flash Rates Available From 45-150 FPM 20%
T1 = ONTime
T2 = OFFTime
T1 ≅T2
ON/OFF Ratio
Input
≅ 50%
Voltage
AC Line Frequency
Output
24, 120VAC, 15%
50/60Hz
Output
Load Type
Fullwave AC or Halfwave rectified AC
Incandescent, resistive, or inductive
(Choose RC suffix for inductive loads)
Fullwave: 1A steady state
Halfwave: 2A steady state
10A
Maximum Load Rating
Inrush
Mechanical
Mounting
Removable mounting bracket, use one #8
(M4 x 0.7) screw
Connection/Wires
Dimensions
Protection
18 AWG (0.82mm2) wires 6 in. (15.2cm)
H 38.1 mm (1.5”); W 23.9 mm (0.94”)
Circuitry
Encapsulated
Environmental
Operating/Storage
Temperature
Humidity
-20° to 60°C / -40° to 85°C
95% relative, non-condensing
≅ 1.1 oz (31 g)
Weight
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/fs100Lowcurrent
Rev: 1-A-062116