GTCR37-401M-R10-FS2 [LITTELFUSE]
TELECOM, SURGE PROTECTION CIRCUIT, CXSS3, ROHS COMPLIANT, CERAMIC, PACKAGE-3;型号: | GTCR37-401M-R10-FS2 |
厂家: | LITTELFUSE |
描述: | TELECOM, SURGE PROTECTION CIRCUIT, CXSS3, ROHS COMPLIANT, CERAMIC, PACKAGE-3 电信 电信集成电路 |
文件: | 总5页 (文件大小:431K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Gas Discharge Tubes
GTCX37-XXXM-R10 Series
Raychem Circuit Protection 7mm 3Pole GDTs
(ceramic gas discharge tubes), are commonly used
to help protect sensitive telecom equipment such
as communication lines, signal lines and data
transmission lines from damage caused by
transient surge voltages that typically result from
lightning strikes and equipment switching
operations.
Raychem Circuit Protection GDTs offer a high
level of surge protection, low capacitance and a
broad array of breakover voltage levels, making
them suitable for applications such as MDF (Main
Distribution Frame) modules, high data-rate
telecom applications (e.g. ADSL, VDSL), and
surge protection on power lines. Raychem Circuit
Protection GDTs can help equipment meet the
most stringent regulatory standards.
Benefits:
Features:
Helps provide overvoltage fault protection against
3Pole, 7mm devices
high energy surges
Broad voltage range from 75V-600V
Suitable for high-frequency applications
Various form factors: surface-mount, leaded, no
leads
Optional fail-short mechanism on some devices
Low capacitance and insertion loss
Crowbar overvoltage protection
UL 497B recognized
RoHS compliant
Devices tested per ITU K.12 recommendations
Non-radioactive materials
Applications:
Telecommunications
• Industrial and consumer electronics, such as
- Surge protectors
- MDF modules, xDSL equipment, RF system
protection, antenna, base station
- Alarm system
Gas Discharge Tubes
© 2008, 2014 Tyco Electronics Corporation. All rights reserved.
Document: SCD27385
Status: Released
1
Rev: C
Date: SEPTEMBER 29, 2014
Gas Dis charge Tubes
GTCX37-XXXM-R10 Series
Device Voltage Ratings and Part Marking
Impulse
Sparkover
DC Holdover
On-State Voltage
Voltage
Part Number
DC Sparkover
@100V/s
±20% Tolerance
(V)
Nominal
Per ITU K.12
(@ 1A)
(<150ms)
(V)
@100 Vµs (V)
@1000 Vµs (V)
(V)
GTCX37-750M-R10
GTCX37-900M-R10
GTCX37-141M-R10
GTCX37-151M-R10
GTCX37-201M-R10
GTCX37-231M-R10
GTCX37-251M-R10
GTCX37-261M-R10
GTCX37-301M-R10
GTCX37-351M-R10
GTCX37-401M-R10
GTCX37-421M-R10
GTCX37-471M-R10
GTCX37-501M-R10
GTCX37-551M-R10
GTCX37-601M-R10
75
450
450
500
500
600
600
600
700
800
900
900
900
1050
1100
1300
1300
550
550
<52
<52
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
90
140
150
200
230
250
260
300
350
400
420
470
500
550
600
600
<80
600
<80
700
<135
<135
<135
<135
<150
<150
<150
<150
<150
<150
<150
<150
700
700
800
900
1000
1000
1000
1150
1200
1400
1400
Device Surge Rating, Capacitance, Insulation Resistance, UL
AC
Impulse
Discharge
Current
Discharge
Current
(1sec duration;
10 hits)
Impulse
Life
Insulation
Resistance
UL
Rating
Part Number
Capacitance
8x20µs
10 hits
10x1000µs
300 hits
UL497B
#E179610
@50 Hz
10Arms
@1Mhz
<1pF
@100V*
GTCX37-XXXM-R10
10kA
200A
10,000 (MΩ)
All Devices
* Devices <=90V measured @ 50V.
Devices >= 500V measured @ 250V
Gas Discharge Tubes
© 2008, 2014 Tyco Electronics Corporation. All rights reserved.
Document: SCD27385
Status: Released
2
Rev: C
Date: SEPTEMBER 29, 2014
Gas Dis charge Tubes
GTCX37-XXXM-R10 Series
Product Dimensions
DIMENSIONS = MILLIMETERS [INCHES]
Radial Leaded with-FS (GTCR37-XXXM-R10-FS2)
Radial Leaded (GTCR37-XXXM-R10)
No Leads (GTCN37-XXXM-R10)
Gas Discharge Tubes
© 2008, 2014 Tyco Electronics Corporation. All rights reserved.
Document: SCD27385
Status: Released
3
Rev: C
Date: SEPTEMBER 29, 2014
Gas Dis charge Tubes
GTCX37-XXXM-R10 Series
General Characteristics
No Radioactive Material
Storage Temperature: -40ºC to +90ºC
Operating Temperature: -40ºC to +90ºC
Body: Nickel Plated
Leads: Tin Plated (Radial Devices)
Devices with no leads: Nickel Plated
Soldering Notes: Devices with no leads: non-solderable; suitable for insertion into a magazine clip
Materials Information
RoHS Compliant
ELV Compliant
Packaging Information
Part Description
Tray / Reel
Standard Package
No Leaded:
With Leads:
GTCN37-XXXM-R10
GTCR37-XXXM-R10(-FS)
100pcs (Tray)
100pcs (Tray)
1,000pcs
1,000pcs
Part Numbering System
Example Part Number: GTCX37-351M-R10-FS
GT =
C =
Gas Tube
Ceramic
X =
Lead Configuration: N= No leads; R= Radial Leads
3 =
3 Electrode device
7 =
7mm Diameter
351 =
M =
R =
10 =
FS
DC Spark Over Voltage of 350V (at 100V/s)
Tolerance of 20% on DC Spark Over Voltage
Product Family Designator
Surge rating: 8x20µs 10kA 10 times
With Fail-Short mechanism
Gas Discharge Tubes
Document: SCD27385
Status: Released
Rev: C Date: SEPTEMBER 29, 2014
© 2008, 2014 Tyco Electronics Corporation. All rights reserved.
4
Gas Dis charge Tubes
GTCX37-XXXM-R10 Series
Part Marking Reference
Example Part Marking:
35 R10 GN
Manufacture Mark
=
35 =
Voltage Designator (35 = 350V)
R10 =
Product Family Designator + Surge Current 10kA (8x20µs 10 hits)
Year and Week of Manufacture
GN =
308 Constitution Drive, MS R21/2A
Menlo Park, CA USA 94025-1164
Tel (800) 227-7040
(650) 361-6900
Fax (650) 361-2508
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.circuitprotection.jp (Japanese)
Raychem, TE Logo and Tyco Electronics are trademarks.
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product
selected for their own applications. Tyco Electronics reserves the right to change or update, without notice, any information contained in this publication;
to change, without notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of
any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of Tyco
Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facility applications, aerospace, or in critical life
support devices or systems. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics’ only obligations are those in the Tyco
Electronics Standard Terms and Conditions of Sale and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages
arising from the sale, resale, use, or misuse of its products.
Gas Discharge Tubes
Document: SCD27385
Status: Released
© 2008, 2014 Tyco Electronics Corporation. All rights reserved.
5
Rev: C
Date: SEPTEMBER 29, 2014
相关型号:
©2020 ICPDF网 联系我们和版权申明