KLLU601 [LITTELFUSE]
General Purpose Fuses; 通用保险丝型号: | KLLU601 |
厂家: | LITTELFUSE |
描述: | General Purpose Fuses |
文件: | 总3页 (文件大小:190K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General Purpose Fuses
KLLU Class L Fuses
600 VAC • Time-Delay • 601 – 4000 Amperes
Applications
Service switches
Switchboard mains and feeders
Bolted pressure contact switches
Motor control center mains
Large motor branch circuits
UL Listed series rated protection for molded case circuit breaker
panelboards and loadcenters. See panelboard manufacturers’
literature for recommended fuse rating.
Safety
• 200,000 A.I.R. — Provides reliable interruption of all overcurrents up
to 200,000 amperes.
• When used for motor branch circuit protection, KLLU fuses may be
sized close to the motor full load current, providing excellent protection
to branch circuit conductors, motor control equipment and motors.
Longer Equipment Life
• Current-Limiting — Reduces short-circuit damage to systems and
equipment.
• Reduced downtime.
• Ten second minimum time-delay at 500% current eliminates
needless downtime caused by heavy starting currents of large
motors and other inductive loads.
• Selective coordination — KLLU fuses coordinate well with other
Class L fuses and with all current-limiting Littelfuse fuses rated 600
amps or less. This means less time spent trying to locate short-
circuits or overloaded equipment, because only the fuse immediately
on the line side of the affected circuit opens.
KLLU series UL Listed, time-delay, Class L fuses are quality fuses,
developed to provide a somewhat lower priced alternate to the
POWR-PRO® KLPC series fuses. KLLU series fuses meet or exceed
all UL requirements for Class L fuses. For superior protection and
performance, specification-grade POWR-PRO KLPC series fuses are
the recommended fuse. Complete information on KLPC fuses may
be found in the POWR-PRO Fuse section of this catalog.
Easy To Use
• 200,000 A.I.R. rating minimizes need for short-circuit calculations,
while meeting present and future system requirements.
• KLLU fuse time-current characteristics closely match typical time-
current curves of circuit breakers. Although fuse/circuit breaker systems
can seldom be 100% coordinated, KLLU series fuses permit use of a
wider range of breaker setting than fast acting Class L fuses.
Excellent protection for a single breaker or a group of breakers.
Specifications
Ampere Ratings
Voltage Ratings:
AC: 600 Volts
DC: Contact factory
601
650
700
750
800
900
1000
1200
1350
1400
1500
1600
1800
2000
2500
3000
3500
4000
Interrupting Ratings:
Ampere Range:
Approvals:
200,000 amperes rms symmetrical
601 – 4000 amperes
Standard 248-10, Class L
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)
Example part number (series & amperage): KLLU 1000
26
w w w . l i t t e l f u s e . c o m
© 2005 Littelfuse POWR-GARD™ Products Catalog
•
General Purpose Fuses
KLLU Class L Fuses
600 VAC • Time-Delay • 601 – 4000 Amperes
J
J
H
J
F
D E F
A
B
C
C B
A
C
B A
D
E F
N
M
N
M
G
M
FIG.2
FIG.1
FIG. 3
J
H
C
B A
D
E
F
L
K
N
M
G
FIG. 4
Dimensions In Inches (mm in parentheses)
Fig.
No.
Amperes
A
B
C
D
E
F
G
H
J
K
L
M
N
3
3
3
5
1
3
5
1
8
4
4
4
8
2
2
8
8
—
3 ⁄
5 ⁄
6 ⁄
8 ⁄
2 ⁄
⁄
⁄ x 1 ⁄
601 – 800
801 – 1200
—
—
—
—
1
2
2
2
3
3
4
(50.8)
(95.3)
(146.1)
(171.5)
(219.1)
(63.5)
(9.5)
(15.9) x (28.6)
3
3
3
1
1
3
1
3
5
3
5
1
8
4
4
4
4
2
4
2
2
8
8
4
8
3 ⁄
5 ⁄
6 ⁄
9 ⁄
9 ⁄
10 ⁄
2 ⁄
⁄
⁄ x ⁄
⁄ x 1 ⁄
—
—
—
—
(50.8)
(95.3)
(146.1)
(171.5)
(235.0)
(241.3)
(273.1)
(63.5)
(9.5)
(15.9) x (19.1)
(15.9) x (28.6)
3
3
3
1
1
3
3
7
5
3
5
1
8
4
4
4
4
2
4
8
3
16
8
4
8
3 ⁄
5 ⁄
6 ⁄
9 ⁄
9 ⁄
10 ⁄
2 ⁄
⁄
⁄ x ⁄
⁄ x 1 ⁄
1201 – 1600
1601 – 2000
2001 – 2500
2501 – 3000
3001 – 4000
(76.2)
(95.3)
(146.1)
(171.5)
(235.0)
(241.3)
(273.1)
(60.3)
(11.1)
(15.9) x (19.1)
(15.9) x (28.6)
3
3
3
1
1
3
3
1
1
5
3
5
1
8
4
4
4
4
2
4
4
2
2
8
4
8
3 ⁄
5 ⁄
6 ⁄
9 ⁄
9 ⁄
10 ⁄
2 ⁄
3 ⁄
⁄
⁄ x ⁄
⁄ x 1 ⁄
—
—
(95.3)
(146.1)
(171.5)
(235.0)
(241.3)
(273.1)
(69.9)
(88.9)
(12.7)
(15.9) x (19.1)
(15.9) x (28.6)
3
3
1
1
3
5
3
1
3
5
3
5
1
8
4
4
4
4
2
4
8
4
2
5
4
8
4
8
5 ⁄
6 ⁄
9 ⁄
9 ⁄
10 ⁄
1 ⁄
1 ⁄
3 ⁄
⁄
⁄ x ⁄
⁄ x 1 ⁄
(101.6)
(127.0)
(146.1)
(171.5)
(235.0)
(241.3)
(273.1)
(41.3) (44.5)
(88.9)
(19.1)
(15.9) x (19.1)
(15.9) x (28.6)
3
3
1
1
3
5
3
3
5
3
5
1
8
4
4
4
4
2
4
8
4
4
5
4
8
4
8
5 ⁄
6 ⁄
9 ⁄
9 ⁄
10 ⁄
1 ⁄
1 ⁄
⁄
⁄ x ⁄
⁄ x 1 ⁄
(101.6)
(101.6)
(127.0)
(146.1)
(171.5)
(235.0)
(241.3)
(273.1)
(41.3) (44.5)
(19.1)
(15.9) x (19.1)
(15.9) x (28.6)
3
3
1
3
3
3
5
3
5
3
8
3
3
1
1
4
4
4
4
4
4
8
8
8
10 ⁄
1 ⁄
3 ⁄
4 ⁄
5 ⁄
⁄
⁄ x 1 ⁄
⁄ x 1 ⁄
4
4
4
2
4
5 ⁄
6 ⁄
9 ⁄
9 ⁄
(101.6) (146.1)
(171.5)
(235.0)
(241.3)
(273.1) (44.5) (82.6) (120.7) (146.1)
(19.1)
(15.9) x (34.9) (15.9) x (34.9)
© 2005 Littelfuse POWR-GARD™ Products Catalog
w w w . l i t t e l f u s e . c o m
27
•
General Purpose Fuses
KLLU Class L Fuses
600 VAC • Time-Delay • 601 – 4000 Amperes
Current-Limiting Effects of KLLU (600V) fuses
Apparent RMS Symmetrical Current for Various Fuse Ratings
Short-Circuit Current*
800A
5,000
1200A
5,000
1600A
5,000
2000A
5,000
3000A
5,000
4000A
5,000
5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
50,000
60,000
80,000
100,000
150,000
200,000
10,000
11,900
13,000
14,000
14,500
15,000
16,000
17,000
18,000
19,000
21,000
24,000
26,000
10,000
15,000
18,500
20,000
21,000
22,000
23,000
24,000
26,000
28,000
30,000
35,000
38,000
10,000
15,000
20,000
25,000
26,500
28,500
30,000
32,000
34,000
36,000
38,000
44,000
48,000
10,000
15,000
20,000
25,000
30,000
34,000
35,000
38,000
42,000
44,000
46,000
50,000
53,000
10,000
15,000
20,000
25,000
30,000
35,000
37,000
39,000
43,000
46,000
48,000
51,000
60,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
44,000
50,000
54,500
57,500
68,000
74,000
* Prospective RMS Symmetrical Amperes Short-Circuit Current
Note: Data Derived from Peak Let-Thru Curves
1000
800
600
10000000
1000000
100000
10000
400
300
200
100
80
60
40
30
20
10
8
6
4000A
3000A
2000A
1600A
1200A
800A
4
3
2
1
.8
.6
.4
.3
.2
.1
.08
.06
.04
.03
.02
1000
.01
AVAILABLE FAULT CURRENT
SYMMETRICAL R.M.S. AMPERES
CURRENT IN AMPERES
28
w w w . l i t t e l f u s e . c o m
© 2005 Littelfuse POWR-GARD™ Products Catalog
•
相关型号:
©2020 ICPDF网 联系我们和版权申明