L4008R8TP [LITTELFUSE]

TRIAC, 400V V(DRM), 8A I(T)RMS,;
L4008R8TP
型号: L4008R8TP
厂家: LITTELFUSE    LITTELFUSE
描述:

TRIAC, 400V V(DRM), 8A I(T)RMS,

栅 三端双向交流开关 栅极
文件: 总14页 (文件大小:378K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
tꢀ  
tꢀ  
                                                                                       
/PꢀDPOUBDUTꢀUPꢀXFBSꢀPVUꢀ  
from reaction of switching  
events  
                                                                
7PMUBHFꢀDBQBCJMJUZꢀVQꢀ  
to 1000 V  
                                                                                       
3FTUSJDUFEꢀꢂPSꢀMJNJUFEꢃꢀ3'*ꢀ  
generation, depending on  
activation point of  
                                                                
4VSHFꢀDBQBCJMJUZꢀVQꢀ  
to 100 A  
                                                                
&MFDUSJDBMMZꢀJTPMBUFEꢀ  
“L-Package” is UL  
tꢀ  
                                                                                       
3FRVJSFTꢀPOMZꢀBꢀTNBMMꢀHBUFꢀ  
activation pulse in each  
half-cycle  
tꢀ  
                                                                
4PMJEꢁTUBUFꢀTXJUDIJOHꢀ  
tꢀ  
tꢀ  
tꢀ  
tꢀ  
                                                                
(MBTTꢀoꢀQBTTJWBUFEꢀ  
junctions  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
Description  
8 Amp bi-directional solid state switch series is designed  
for AC switching and phase control applications such as  
motor speed and temperature modulation controls, lighting  
controls, and static switching relays.  
Sensitive type devices guarantee gate control in Quadrants  
I & IV needed for digital control circuitry.  
Standard type devices normally operate in Quadrants I & III  
triggered from AC line.  
Alternistor type devices only operate in quadrants I, II, & III  
and are used in circuits requiring high dv/dt capability.  
Agency Approval  
Features & Benefits  
tꢀ3P)4ꢀDPNQMJBOU  
contact bounce that  
create voltage transients  
Agency  
Agency File Number  
L Package: E71639  
®
Main Features  
Symbol  
IT(RMS)  
Value  
Unit  
A
sine wave  
8
VDRM/VRRM  
IGT (Q1)  
400 to 1000  
5 to 50  
V
recognized for 2500Vrms  
mA  
eliminates arcing or  
Schematic Symbol  
Applications  
Excellent for AC switching and phase control applications  
such as heating, lighting, and motor speed controls.  
MT2  
MT1  
Typical applications are AC solid-state switches, light  
dimmers, power tools, home/brown goods and white  
goods appliances.  
G
AlternistorTriacs (no snubber required) are used in  
applications with extremely inductive loads requiring  
highest commutation performance.  
Internally constructed isolated packages are offered for  
ease of heat sinking with highest isolation voltage.  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
77  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Absolute Maximum Ratings — SensitiveTriac (4 Quadrants)  
Symbol Parameter  
IT(RMS)  
Value  
Unit  
Lxx08Ly  
TC = 80°C  
TC = 85°C  
t = 20 ms  
t = 16.7 ms  
RMS on-state current (full sine wave)  
8
A
Lxx08Ry / Lxx08Vy / Lxx08Dy  
f = 50 Hz  
65  
85  
Non repetitive surge peak on-state current  
(full cycle, TJ initial = 25°C)  
ITSM  
A
f = 60 Hz  
I2t  
I2t Value for fusing  
tp = 8.3 ms  
f = 120 Hz  
26.5  
70  
A2s  
Critical rate of rise of on-state current  
IG = 50mA with 0.1μs rise time  
di/dt  
A/ꢀs  
TJ = 110°C  
IGTM  
PG(AV)  
Tstg  
TJ  
Peak gate trigger current  
Average gate power dissipation  
Storage temperature range  
tp 10 ꢀs  
1.6  
A
TJ = 110°C  
TJ = 110°C  
0.4  
W
°C  
°C  
-40 to 150  
-40 to 110  
Operating junction temperature range  
Note: xx = voltage, y = sensitivity  
Absolute Maximum Ratings — StandardTriac  
Symbol  
Parameter  
Value  
Unit  
Qxx08Ry / Qxx08Ny  
Qxx08Ly  
TC = 95°C  
TC = 90°C  
IT(RMS)  
RMS on-state current (full sine wave)  
8
A
A
f = 50 Hz  
f = 60 Hz  
t = 20 ms  
83  
100  
41  
Non repetitive surge peak on-state current  
(full cycle, TJ initial = 25°C)  
ITSM  
t = 16.7 ms  
I2t  
I2t Value for fusing  
tp = 8.3 ms  
A2s  
Critical rate of rise of on-state current  
di/dt  
f = 120 Hz  
tp 10 ꢀs;  
IGT TGTM  
70  
A/ꢀs  
TJ = 125°C  
IG = 200mA with 0.1μs rise time  
IGTM  
Peak gate trigger current  
1.8  
A
TJ = 125°C  
TJ = 125°C  
PG(AV)  
Tstg  
TJ  
Average gate power dissipation  
Storage temperature range  
0.5  
W
°C  
°C  
-40 to 150  
-40 to 125  
Operating junction temperature range  
Note: xx = voltage, y = sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
78  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Absolute Maximum Ratings — Alternistor (3 Quadrants)  
Symbol Parameter  
Value  
Unit  
Qxx08LHy  
TC = 90°C  
TC = 95°C  
IT(RMS)  
RMS on-state current (full sine wave)  
8
A
Qxx08RHy / Qxx08NHy  
Qxx08VHy / Qxx08DHy  
Qxx08VHy /  
Qxx08DHy  
80  
83  
f = 50 Hz  
f = 60 Hz  
t = 20 ms  
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
Non repetitive surge peak on-state current  
(full cycle, TJ initial = 25°C)  
ITSM  
A
Qxx08VHy /  
Qxx08DHy  
85  
t = 16.7 ms  
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
100  
30  
Qxx08VHy /  
Qxx08DHy  
I2t  
I2t Value for fusing  
Critical rate of rise of on-state current  
Peak gate trigger current  
tp = 8.3 ms  
A2s  
A/ꢀs  
A
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
41  
di/dt  
IGTM  
f = 120 Hz  
70  
TJ = 125°C  
Qxx08VHy /  
Qxx08DHy  
1.6  
tP 10 ꢀs;  
IGT IGTM  
TJ = 125°C  
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
2.0  
0.4  
0.5  
Qxx08VHy /  
Qxx08DHy  
IGT = 10mA  
IGT = 35mA  
PG(AV)  
Average gate power dissipation  
W
TJ = 125°C  
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
Storage temperature range  
-40 to 150  
-40 to 125  
°C  
°C  
Tstg  
TJ  
Operating junction temperature range  
Note: xx = voltage, y = sensitivity  
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — SensitiveTriac (4 Quadrants)  
Symbol  
Test Conditions  
Quadrant  
Lxx08x6  
Lxx08x8  
Unit  
*ꢀoꢀ**ꢀoꢀ***  
5
10  
10  
20  
IGT  
MAX.  
mA  
IV  
VD = 12V RL = 60 ꢁ  
VGT  
VGD  
IH  
ALL  
ALL  
MAX.  
MIN.  
MAX.  
1.3  
V
V
VD = VDRM RL = 3.3 kTJ = 110°C  
0.2  
IT = 100mA  
10  
30  
20  
2
20  
40  
30  
2
mA  
400V  
600V  
dv/dt  
VD = VDRM Gate Open TJ = 100°C  
TYP.  
V/ꢀs  
(dv/dt)c  
tgt  
(di/dt)c = 4.3 A/ms TJ = 110°C  
TYP.  
TYP.  
V/ꢀs  
ꢀs  
IG = 100mA PW = 15μs IT = 11.3 A(pk)  
3.0  
3.2  
Note: xx = voltage, x = package, y = sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
79  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — StandardTriac  
Symbol  
Test Conditions  
Quadrant  
Qxx08x4  
Qxx08x5  
Unit  
*ꢀoꢀ**ꢀoꢀ***  
MAX.  
TYP.  
25  
50  
50  
75  
IGT  
mA  
IV  
VD = 12V RL = 60 ꢁ  
VGT  
VGD  
IH  
*ꢀoꢀ**ꢀoꢀ***  
MAX.  
MIN.  
MAX.  
1.3  
V
V
VD = VDRM RL = 3.3 kTJ = 125°C  
ALL  
0.2  
IT = 200mA  
50  
50  
mA  
400V  
600V  
800V  
1000V  
150  
125  
100  
80  
dv/dt  
VD = VDRM Gate Open TJ = 125°C  
MIN.  
V/ꢀs  
(dv/dt)c  
tgt  
(di/dt)c = 4.3 A/ms TJ = 125°C  
TYP.  
TYP.  
4
4
V/ꢀs  
ꢀs  
IG = 100mA PW = 15μs IT = 11.3 A(pk)  
3.0  
3.0  
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — AlternistorTriac (3 Quadrants)  
Symbol  
IGT  
Test Conditions  
Quadrant  
Qxx08xH3  
Qxx08xH4  
Unit  
*ꢀoꢀ**ꢀoꢀ***  
MAX.  
10  
35  
mA  
VD = 12V RL = 60 ꢁ  
VGT  
VGD  
IH  
*ꢀoꢀ**ꢀoꢀ***  
*ꢀoꢀ**ꢀoꢀ***  
MAX.  
MIN.  
MAX.  
1.3  
V
V
VD = VDRM RL = 3.3 kTJ = 125°C  
0.2  
IT = 100mA  
15  
75  
50  
35  
mA  
400V  
600V  
800V  
1000V  
400V  
600V  
800V  
1000V  
400  
300  
200  
100  
450  
350  
250  
150  
25  
Qxx08LHy /  
Qxx08RHy /  
Qxx08NHy  
dv/dt  
VD = VDRM Gate Open TJ = 125°C  
MIN.  
V/ꢀs  
75  
50  
Qxx08VHy /  
Qxx08DHy  
(dv/dt)c  
tgt  
(di/dt)c = 4.3 A/ms TJ = 125°C  
MIN.  
TYP.  
20  
V/ꢀs  
ꢀs  
IG = 100mA PW = 15μs IT = 11.3 A(pk)  
4.0  
4.0  
Note : xx = voltage, x = package, y = sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
80  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Static Characteristics  
Symbol  
Test Conditions  
ITM = 11.3A tp = 380 μs  
Value  
1.60  
10  
0.5  
20  
2
Unit  
V
VTM  
MAX.  
MAX.  
TJ = 25°C  
TJ = 110°C  
TJ = 25°C  
TJ = 125°C  
TJ = 100°C  
400 - 600V  
400 - 600V  
400 - 1000V  
400 - 800V  
1000V  
ꢀA  
mA  
ꢀA  
Lxx08xy  
Qxx08xy  
mA  
ꢀA  
IDRM  
VDRM = VRRM  
3
IRRM  
400 - 800V  
1000V  
10  
20  
2
TJ = 25°C  
Qxx08xHy  
TJ = 125°C  
TJ = 100°C  
400 - 800V  
1000V  
mA  
3
Thermal Resistances  
Symbol  
Parameter  
Value  
Unit  
L/Qxx08Ryy /  
L/Qxx08Nyy  
1.5  
Junction to case (AC)  
°C/W  
°C/W  
R(J-C)  
L/Qxx08Lyy  
2.8  
2.1  
45  
50  
64  
L/Qxx08Vyy  
L/Qxx08Ryy  
L/Qxx08Lyy  
L/Qxx08Vyy  
Junction to ambient  
R(J-A)  
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity  
Figure 2: Normalized DC GateTrigger Current for  
All Quadrants vs. JunctionTemperature  
Figure 1: Definition of Quadrants  
ALL POLARITIES ARE REFERENCED TO MT1  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
MT2 POSITIVE  
(Positive Half Cycle)  
MT2  
MT2  
+
(-)  
I
(+)  
I
GT  
GT  
GATE  
GATE  
MT1  
MT1  
REF  
REF  
QII QI  
I
-
+I  
GT  
GT  
QIII QIV  
MT2  
MT2  
(-)  
I
(+)  
I
GATE  
GT  
GT  
GATE  
-65  
-40  
-15  
10  
35  
60  
85  
110  
125  
MT1  
REF  
MT1  
REF  
-
Junction Temperature (TJ)- ºC  
MT2 NEGATIVE  
(Negative Half Cycle)  
Note: Alternistors will not operate in QIV  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
81  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Figure 3: Normalized DC Holding Current  
vs. JunctionTemperature  
Figure 4: Normalized DC GateTriggerVoltage for  
All Quadrants vs. JunctionTemperature  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
2.0  
1.5  
1.0  
0.5  
0.0  
-65  
-40  
-15  
10  
35  
60  
85  
110  
125  
-65  
-40  
-15  
10  
35  
60  
85  
110  
125  
JunctionTemperature (T )- ºC  
JunctionTemperature (T )- ºC  
J
J
Figure 5: Power Dissipation (Typical)  
vs. RMS On-State Current  
Figure 6: Maximum Allowable CaseTemperature  
vs. On-State Current (SensitiveTriac)  
110  
18  
16  
14  
12  
10  
8
105  
Lxx08Vy  
100  
Lxx08Dy  
Lxx08Ry  
95  
90  
Lxx08Ly  
85  
80  
75  
70  
65  
60  
6
CURRENTWAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360  
4
CASETEMPERATURE: Measured as shown on  
Dimensional Drawings  
2
0
0
2
4
6
8
10  
0
1
2
3
4
5
6
7
8
RMS On-State Current (IT(RMS)) - Amps  
RMS On-State Current (IT(RMS)) - Amps  
Figure 7: Maximum Allowable CaseTemperature  
Figure 8: On-State Current vs. On-StateVoltage  
(Typical)  
vs. On-State Current (Standard / AlternistorTriac)  
20  
130  
120  
110  
100  
90  
TC = 25°C  
Qxx08Ryy  
Qxx08Nyy  
Qxx08Vyy  
Qxx08Dyy  
16  
12  
8
Qxx08Lyy  
80  
4
70  
0
60  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
0
1
2
3
4
5
6
7
8
Postitive or Negative Instantaneous  
On-StateVoltage (vT) -Volts  
RMS On-State Current (IT(RMS)) - Amps  
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
82  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Figure 9: Maximum Allowable AmbientTemperature vs. On-State Current  
120  
100  
80  
CURRENTWAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive CONDUCTION  
ANGLE: 360  
FREE AIR RATING - NO HEATSINK  
L/Qxx08Lyy  
L/Qxx08Ryy  
60  
L/Qxx08Vyy  
40  
20  
0.0  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
RMS On-State Current (IT(RMS)) - Amps  
Figure 10: Surge Peak On-State Current vs. Number of Cycles  
100  
L/Qxx08Ryy  
L/Qxx08Lyy  
L/Qxx08Nyy  
SUPPLY FREQUENCY: 60 Hz Sinusoidal  
LOAD: Resistive  
RMS On-State Current: [IT(RMS)]: Maximum Rated  
Value at Specified Case Temperature  
L/Qxx08Vyy  
L/Qxx08Dyy  
Notes:  
1. Gate control may be lost during and immediately  
following surge current interval.  
2. Overload may not be repeated until junction  
temperature has returned to steady-state  
rated value.  
10  
1
1
10  
100  
1000  
Surge Current Duration- Full Cycles  
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
83  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Soldering Parameters  
Reflow Condition  
1Cꢀoꢀ'SFFꢀBTTFNCMZ  
tP  
TP  
-Temperature Min (Ts(min)  
)
150°C  
Ramp-up  
TL  
TS(max)  
Pre Heat -Temperature Max (Ts(max)  
-Time (min to max) (ts)  
)
200°C  
tL  
ꢄꢅꢀoꢀꢆꢇꢅꢀTFDT  
Ramp-down  
Preheat  
Average ramp up rate (LiquidusTemp)  
(TL) to peak  
5°C/second max  
TS(min)  
tS  
TS(max) toTL - Ramp-up Rate  
5°C/second max  
217°C  
-Temperature (TL) (Liquidus)  
Reflow  
25  
time to peak temperature  
-Temperature (tL)  
ꢄꢅꢀoꢀꢆꢈꢅꢀTFDPOET  
260+0/-5 °C  
Time  
PeakTemperature (TP)  
Time within 5°C of actual peak  
Temperature (tp)  
ꢉꢅꢀoꢀꢊꢅꢀTFDPOET  
Ramp-down Rate  
5°C/second max  
8 minutes Max.  
280°C  
Time 25°C to peakTemperature (TP)  
Do not exceed  
Physical Specifications  
Environmental Specifications  
Test  
Specifications and Conditions  
Terminal Finish  
Body Material  
100% MatteTin-plated  
MIL-STD-750, M-1040, Cond A Applied  
Peak AC voltage @ 125°C for 1008 hours  
AC Blocking (VDRM  
)
UL recognized epoxy meeting flammability  
classification 94V-0  
MIL-STD-750, M-1051,  
100 cycles; -40°C to +150°C; 15-min  
dwell-time  
Temperature Cycling  
Terminal Material  
Copper Alloy  
EIA / JEDEC, JESD22-A101  
1008 hours; 320V - DC: 85°C; 85%  
rel humidity  
Temperature/  
Humidity  
MIL-STD-750, M-1031,  
1008 hours; 150°C  
HighTemp Storage  
Low-Temp Storage  
Design Considerations  
1008 hours; -40°C  
Careful selection of the correct device for the applications  
operating parameters and environment will go a long way  
toward extending the operating life of theThyristor. Good  
design practice should limit the maximum continuous  
current through the main terminals to 75% of the device  
rating. Other ways to ensure long life for a power discrete  
semiconductor are proper heat sinking and selection of  
voltage ratings for worst case conditions. Overheating,  
overvoltage (including dv/dt), and surge currents are  
the main killers of semiconductors. Correct mounting,  
soldering, and forming of the leads also help protect  
against component damage.  
MIL-STD-750, M-1056  
10 cycles; 0°C to 100°C; 5-min dwell-  
time at each temperature; 10 sec (max)  
transfer time between temperature  
Thermal Shock  
Autoclave  
EIA / JEDEC, JESD22-A102  
168 hours (121°C at 2 ATMs) and  
100% R/H  
Resistance to  
Solder Heat  
MIL-STD-750 Method 2031  
Solderability  
Lead Bend  
ANSI/J-STD-002, category 3, Test A  
MIL-STD-750, M-2036 Cond E  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
84  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-220AB (R-Package) — Non-Isolated MountingTab Common with Center Lead  
T
C MEASURING POINT  
AREA (REF.) 0.17 IN2  
Inches  
Millimeters  
Min  
Dimension  
O
8.13  
.320  
A
Min  
Max  
0.420  
0.115  
0.250  
0.620  
0.147  
0.130  
0.575  
0.035  
0.205  
0.105  
0.075  
0.095  
0.024  
0.188  
0.060  
0.048  
Max  
10.67  
2.92  
6.35  
15.75  
3.73  
3.30  
14.61  
0.89  
5.21  
2.67  
1.91  
E
P
MT2  
A
B
C
D
E
0.380  
0.105  
0.230  
0.590  
0.142  
0.110  
0.540  
0.025  
0.195  
0.095  
0.060  
0.085  
0.018  
0.178  
0.045  
0.038  
9.65  
2.67  
5.84  
14.99  
3.61  
2.79  
13.72  
0.64  
4.95  
2.41  
1.52  
B
C
13.36  
.526  
D
7. 01  
.276  
NOTCH IN  
GATE LEAD  
TO ID.  
NON-ISOLATED  
TAB  
F
F
G
H
J
R
G
L
H
K
K
N
L
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs. (0.904 Nm).  
J
M
M
N
O
P
2.16  
0.46  
4.52  
1.14  
2.41  
0.61  
4.78  
1.52  
MT1 MT2  
GATE  
R
0.97  
1.22  
Dimensions TO-220AB (L-Package) — Isolated MountingTab  
T
C MEASURING POINT  
AREA (REF.) 0.17 IN2  
Inches  
Millimeters  
Dimension  
O
8.13  
.320  
A
E
Min  
Max  
0.420  
0.115  
0.250  
0.620  
0.147  
0.130  
0.575  
0.035  
0.205  
0.105  
0.075  
0.095  
0.024  
0.188  
0.060  
0.048  
Min  
9.65  
2.67  
5.84  
14.99  
3.61  
2.79  
13.72  
0.64  
4.95  
2.41  
1.52  
Max  
10.67  
2.92  
6.35  
15.75  
3.73  
3.30  
14.61  
0.89  
5.21  
2.67  
1.91  
P
A
B
C
D
E
0.380  
0.105  
0.230  
0.590  
0.142  
0.110  
0.540  
0.025  
0.195  
0.095  
0.060  
0.085  
0.018  
0.178  
0.045  
0.038  
B
C
13.36  
.526  
D
7. 01  
.276  
F
F
G
H
J
R
G
L
H
K
K
N
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs. (0.904 Nm).  
L
J
MT1 MT2  
M
M
N
O
P
2.16  
0.46  
4.52  
1.14  
2.41  
0.61  
4.78  
1.52  
GATE  
R
0.97  
1.22  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
85  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-263AB (N-Package) — D2-PAK Surface Mount  
T
C MEASURING POINT  
AREA: 0.11 IN2  
Inches  
Millimeters  
C
B
V
Dimension  
E
MT2  
Min  
Max  
0.370  
0.420  
0.188  
0.035  
0.060  
0.075  
0.105  
0.102  
0.024  
0.110  
0.625  
0.045  
0.010  
0.070  
Min  
9.14  
9.65  
4.52  
0.64  
1.14  
Max  
9.40  
10.67  
4.78  
0.89  
1.52  
A
B
C
D
E
0.360  
0.380  
0.178  
0.025  
0.045  
0.060  
0.095  
0.092  
0.018  
0.090  
0.590  
0.035  
0.002  
0.040  
8.41  
.331  
7. 01  
.276  
A
S
W
U
J
K
GATE  
MT1  
8.13  
.320  
G
F
1.52  
2.41  
2.34  
0.46  
2.29  
14.99  
0.89  
0.05  
1.02  
1.91  
H
D
F
G
H
J
2.67  
2.59  
0.61  
2.79  
15.88  
1.14  
11.68  
.460  
2.16  
.085  
K
7. 01  
.276  
7. 01  
.276  
S
16.89  
.665  
V
8.89  
.350  
1.40  
.055  
U
W
0.25  
1.78  
3.81  
.150  
2.03  
.080  
6.60  
.260  
Dimensions TO-251AA (V-Package) V-PAKThrough Hole  
TC MEASURING POINT  
AREA: 0.040 IN2  
Inches  
Typ  
Millimeters  
Dimension  
Min  
Max  
Min  
0.94  
5.97  
8.89  
5.21  
6.48  
0.69  
2.21  
2.16  
4.47  
0.46  
0.90  
0.46  
1.06  
0.86  
0.86  
1.86  
Typ  
1.01  
6.15  
9.18  
5.29  
6.66  
0.80  
2.28  
2.34  
4.57  
0.51  
0.95  
0.52  
1.20  
1.00  
1.00  
2.00  
Max  
1.09  
6.22  
9.53  
5.41  
6.73  
0.84  
2.36  
2.41  
4.67  
0.58  
1.00  
0.58  
1.32  
1.11  
E
H
J
5.28  
.208  
MT2  
A
D
A
B
C
D
E
F
0.037  
0.235  
0.350  
0.205  
0.255  
0.027  
0.087  
0.085  
0.176  
0.018  
0.035  
0.018  
0.042  
0.034  
0.034  
0.074  
0.040  
0.242  
0.361  
0.208  
0.262  
0.031  
0.090  
0.092  
0.180  
0.020  
0.037  
0.020  
0.047  
0.039  
0.039  
0.079  
0.043  
0.245  
0.375  
0.213  
0.265  
0.033  
0.093  
0.095  
0.184  
0.023  
0.039  
0.023  
0.052  
0.044  
0.044  
0.084  
5.34  
.210  
B
R
P
Q
S
G
H
I
K
C
J
K
L
MT1  
L
F
MT2  
GATE  
G
P
Q
R
S
I
1.11  
2.11  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
86  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-252AA (D-Package) — D-PAK Surface Mount  
E
6.71  
.264  
MT2  
A
5.28  
.208  
Inches  
Typ  
Millimeters  
Typ  
TC MEASURING POINT  
D
Dimension  
Min  
0.037  
0.235  
0.106  
0.205  
0.255  
0.027  
0.087  
0.085  
0.176  
0.018  
0.035  
0.018  
0.000  
0.021  
0°  
Max  
0.043  
0.245  
0.113  
0.213  
0.265  
0.033  
0.093  
0.095  
0.184  
0.023  
0.039  
0.023  
0.004  
0.027  
5°  
Min  
0.94  
5.97  
2.69  
5.21  
6.48  
0.69  
2.21  
2.16  
4.47  
0.46  
0.90  
0.46  
0.00  
0.53  
0°  
Max  
1.09  
6.22  
2.87  
5.41  
6.73  
0.84  
2.36  
2.41  
4.67  
0.58  
1.00  
0.58  
0.10  
0.69  
5°  
6.71  
.264  
5.34  
.210  
A
B
C
D
E
F
0.040  
0.243  
0.108  
0.208  
0.262  
0.031  
0.090  
0.092  
0.179  
0.020  
0.037  
0.020  
0.000  
0.026  
0°  
1.01  
B
6.16  
2.74  
1.60  
.063  
P
Q
C
5.29  
6.65  
0.80  
2.28  
2.33  
4.55  
0.51  
0.95  
0.51  
0.00  
0.67  
0°  
1.80  
.071  
GATE  
F
AREA: 0.040 IN2  
MT1  
MT2  
3
.118  
4.60  
.181  
G
I
G
H
I
L
O
H
K
J
M
N
J
K
L
M
N
O
P
Q
0.042  
0.034  
0.047  
0.039  
0.052  
0.044  
1.06  
0.86  
1.20  
1.32  
1.11  
1.00  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
87  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Product Selector  
Voltage (xx)  
400V 600V 800V 1000V  
Gate Sensitivity Quadrants  
Part Number  
Type  
Package  
I – II – III  
5 mA  
IV  
Lxx08L6  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10 mA  
10 mA  
10mA  
10 mA  
20 mA  
20 mA  
20mA  
20 mA  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
SensitiveTriac  
AlternistorTriac  
AlternistorTriac  
AlternistorTriac  
AlternistorTriac  
Triac  
TO-220L  
TO-252 D-PAK  
TO-220R  
Lxx08D6  
Lxx08R6  
5 mA  
5mA  
Lxx08V6  
5 mA  
TO-251 V-PAK  
TO-220L  
Lxx08L8  
10 mA  
10 mA  
10mA  
10 mA  
10mA  
10 mA  
10 mA  
10 mA  
25 mA  
25 mA  
25 mA  
35 mA  
35 mA  
35 mA  
35 mA  
35 mA  
50 mA  
50 mA  
50 mA  
Lxx08D8  
Lxx08R8  
TO-252 D-PAK  
TO-220R  
Lxx08V8  
TO-251 V-PAK  
TO-263 D²-PAK  
TO-220R  
Qxx08NH3  
Qxx08RH3  
Qxx08VH3  
Qxx08DH3  
Qxx08L4  
Qxx08R4  
Qxx08N4  
Qxx08LH4  
Qxx08RH4  
Qxx08VH4  
Qxx08DH4  
Qxx08NH4  
Qxx08L5  
Qxx08R5  
Qxx08N5  
TO-251 V-PAK  
TO-252 D-PAK  
TO-220L  
Triac  
TO-220R  
Triac  
TO-263 D²-PAK  
TO-220L  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AlternistorTriac  
AlternistorTriac  
AlternistorTriac  
AlternistorTriac  
AlternistorTriac  
Triac  
TO-220R  
TO-251 V-PAK  
TO-252 D-PAK  
TO-263 D²-PAK  
TO-220L  
Triac  
TO-220R  
Triac  
TO-263 D²-PAK  
Packing Options  
Part Number  
L/Qxx08L/Ryy  
L/Qxx08L/RyyTP  
Qxx08NyyTP  
Marking  
Weight  
Packing Mode  
Base Quantity  
L/Qxx08L/Ryy  
L/Qxx08L/Ryy  
Qxx08Nyy  
2.2 g  
2.2 g  
1.6 g  
1.6 g  
0.3 g  
0.3 g  
0.4 g  
Bulk  
Tube Pack  
Tube  
500  
500 (50 per tube)  
500 (50 per tube)  
500  
Qxx08NyyRP  
Qxx08Nyy  
Embossed Carrier  
Tube  
L/Qxx08DyyTP  
L/Qxx08DyyRP  
L/Qxx08VyyTP  
L/Qxx08Dyy  
L/Qxx08Dyy  
L/Qxx08Vyy  
750 (75 per tube)  
2500  
Embossed Carrier  
Tube  
750 (75 per tube)  
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
88  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
TO-252 Embossed Carrier Reel Pack (RP) Specifications  
Meets all EIA-481-2 Standards  
0.157  
(4.0)  
0.059  
(1.5)  
Dia  
Gate  
MT1  
0.63  
(16.0)  
0.524  
(13.3)  
*
0.315  
(8.0)  
*
Cover tape  
MT2  
12.99  
(330.0)  
0.512 (13.0) Arbor  
Hole Dia.  
Dimensions  
are in inches  
(and millimeters).  
0.64  
(16.3)  
Direction of Feed  
TO-263 Embossed Carrier Reel Pack (RP) Specifications  
Meets all EIA-481-2 Standards  
0.63  
(16.0)  
0.157  
(4.0)  
Gate  
MT1  
0.059  
(1.5)  
DIA  
0.945  
(24.0)  
0.827  
(21.0)  
*
*
Cover tape  
MT2  
12.99  
(330.0)  
0.512 (13.0) Arbor  
Hole Dia.  
Dimensions  
are in inches  
(and millimeters).  
1.01  
(25.7)  
Direction of Feed  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
89  
Revised: 09/23/13  
Teccor® brandThyristors  
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs  
Part Numbering System  
Q 60 08 L 5 56  
Part Marking System  
TO-251AA – (V Package)  
TO-252AA – (D Package)  
DEVICE TYPE  
L : Sensitive Triac  
LEAD FORM DIMENSIONS  
xx : Lead Form Option  
Q : Triac or Alternistor  
L6008V5  
L6008V5  
VOLTAGE RATING  
40 : 400V  
60 : 600V  
80: 800V  
K0 : 1000V  
SENSITIVITY & TYPE  
Sensitive Triac:  
6
:
5 mA (QI, II, III)  
10 mA (QIV)  
8
:
10 mA (QI, II, III)  
20 mA (QIV)  
YMLDD  
YMLDD  
®
®
Standard Triac:  
Date Code Marking  
Y:Year Code  
M: Month Code  
L: Location Code  
DD: Calendar Code  
CURRENT  
4
5
:
:
25 mA (QI, II, III)  
50 mA (QI, II, III)  
08: 8A  
Alternistor Triac:  
H3  
H4  
:
:
10 mA (QI, II, III)  
35 mA (QI, II, III)  
TO-220 AB - (L and R Package)  
TO-263 AB - (N Package)  
PACKAGE TYPE  
L : TO-220 Isolated  
R : TO-220 Non-Isolated  
N: TO-263 (D2PAK)  
V : TO-251 (VPAK)  
D : TO-252 (DPAK)  
Q6008R5  
YMXXX  
®
Date Code Marking  
Y:Year Code  
M: Month Code  
XXX: Lot Trace Code  
Lxx08xx & Qxx08xx & Qxx08xHx Series  
©2013 Littelfuse, Inc  
Specifications are subject to change without notice.  
90  
Revised: 09/23/13  

相关型号:

L4008R8TP56

4 Quadrant Logic Level TRIAC
LITTELFUSE

L4008RH356

8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
LITTELFUSE

L4008V456

8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
LITTELFUSE

L4008V6

Sensitive Triacs (0.8A to 8A)
TECCOR

L4008V6

Sensitive Triacs (0.8 A to 8 A)
LITTELFUSE

L4008V656

8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
LITTELFUSE

L4008V6RP

4 Quadrant Logic Level TRIAC, 400V V(DRM), 8A I(T)RMS, TO-251AA, VPAK-3
LITTELFUSE

L4008V6TP

4 Quadrant Logic Level TRIAC, 400V V(DRM), 8A I(T)RMS, TO-251AA, VPAK-3
LITTELFUSE

L4008V6TP56

4 Quadrant Logic Level TRIAC
LITTELFUSE

L4008V8

Sensitive Triacs (0.8A to 8A)
TECCOR

L4008V8

Sensitive Triacs (0.8 A to 8 A)
LITTELFUSE

L4008V856

8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
LITTELFUSE