L6006R8 [LITTELFUSE]
TRIAC, 600V V(DRM), 6A I(T)RMS, TO-220AB, ROHS COMPLIANT, PLASTIC PACKAGE-3;型号: | L6006R8 |
厂家: | LITTELFUSE |
描述: | TRIAC, 600V V(DRM), 6A I(T)RMS, TO-220AB, ROHS COMPLIANT, PLASTIC PACKAGE-3 局域网 栅 三端双向交流开关 栅极 |
文件: | 总14页 (文件大小:1081K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Lxx06xx & Qxx06xx & Qxx06xHx Series
®
Description
6 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in
Quadrants I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I &
III triggered from AC line.
Alternistor type devices only operate in quadrants I, II, &
III and are used in circuits requiring high dv/dt capability.
Features & Benefits
• RoHS compliant
contact bounce that
Agency Approval
create voltage transients
• Glass – passivated
junctions
• No contacts to wear out
from reaction of switching
events
Agency
Agency File Number
• Voltage capability up
to 1000 V
L Package: E71639
®
• Restricted (or limited) RFI
generation, depending on
activation point of
• Surge capability up
to 85 A
Main Features
• Electrically isolated
“L - Package” is UL
recognized for 2500Vrms
sine wave
• Requires only a small gate
activation pulse in each
half-cycle
Symbol
IT(RMS)
Value
Unit
A
• Solid-state switching
eliminates arcing or
6
VDRM/VRRM
IGT (Q1)
400 to 1000
5 to 50
V
Applications
mA
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Schematic Symbol
Typical applications are AC solid-state switches, light
dimmers, power tools, home/brown goods and white
goods appliances.
AlternistorTriacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
MT2
MT1
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
G
Absolute Maximum Ratings — SensitiveTriac (4 Quadrants)
Symbol Parameter
Value
Unit
Lxx06Ly
Lxx06Vy / Lxx06Dy/ Lxx06Ry
f = 50 Hz
TC = 80°C
TC = 85°C
t = 20 ms
t = 16.7 ms
IT(RMS)
RMS on-state current (full sine wave)
6
A
50
60
15
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
I2t Value for fusing
Critical rate of rise of on-state current
IG = 50mA with 0.1µs rise time
ITSM
I2t
A
f = 60 Hz
tp = 8.3 ms
A2s
A/μs
di/dt
f = 120 Hz
70
TJ = 110°C
IGTM
PG(AV)
Tstg
TJ
Peak gate trigger current
Average gate power dissipation
Storage temperature range
tp ≤ 10 μs
1.6
A
TJ = 110°C
TJ = 110°C
0.4
W
°C
°C
-40 to 150
-40 to 110
Operating junction temperature range
Note: xx = voltage, y = sensitivity
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
61
Revised: June 24, 2011 04:57 PM
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Absolute Maximum Ratings — StandardTriac
Symbol
IT(RMS)
Parameter
Value
Unit
Qxx06Ry / Qxx06Ny
Qxx06Ly
TC = 95°C
TC = 90°C
RMS on-state current (full sine wave)
6
A
f = 50 Hz
t = 20 ms
65
80
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
f = 60 Hz
t = 16.7 ms
I2t
I2t Value for fusing
tp = 8.3 ms
26.5
A2s
Critical rate of rise of on-state current
IG = 200mA with 0.1µs rise time
di/dt
f = 120 Hz
70
A/μs
TJ = 125°C
IGTM
PG(AV)
Tstg
TJ
Peak gate trigger current
Average gate power dissipation
Storage temperature range
tp ≤ 10 μs; IGT ≤ IGTM
1.6
A
TJ = 125°C
TJ = 125°C
0.5
W
°C
°C
-40 to 150
-40 to 125
Operating junction temperature range
Note: xx = voltage, y = sensitivity
Absolute Maximum Ratings — AlternistorTriac (3 Quadrants)
Symbol Parameter
IT(RMS)
Value
Unit
Qxx06LHy
TC = 95°C
RMS on-state current (full sine wave)
6
A
Qxx06RHy / Qxx06NHy
Qxx06VHy / Qxx06DHy
TC = 100°C
Qxx06VHy
Qxx06DHy
55
80
f = 50 Hz
f = 60 Hz
t = 20 ms
Qxx06LHy
Qxx06RHy
Qxx06NHy
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
Qxx06VHy
Qxx06DHy
65
t = 16.7 ms
Qxx06LHy
Qxx06RHy
Qxx06NHy
85
Qxx06VHy
Qxx06DHy
17. 5
30
I2t
I2t Value for fusing
tp = 8.3 ms
A2s
Qxx06LHy
Qxx06RHy
Qxx06NHy
di/dt
IGTM
PG(AV)
Tstg
TJ
Critical rate of rise of on-state current
Peak gate trigger current
f = 120 Hz
70
1.6
A/μs
A
TJ = 125°C
TJ = 125°C
TJ = 125°C
tp ≤ 10 μs; IGT ≤ IGTM
Average gate power dissipation
Storage temperature range
0.5
W
-40 to 150
-40 to 125
°C
°C
Operating junction temperature range
Note: xx = voltage, y = sensitivity
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
62
Revised: June 24, 2011 04:57 PM
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — SensitiveTriac (4 Quadrants)
Value
Symbol
IGT
Test Conditions
Quadrant
Unit
Lxx06x5 Lxx06x6 Lxx06x8
I – II – III
5
5
5
10
10
20
MAX.
mA
IV
VD = 12V RL = 60 Ω
VGT
VGD
IH
ALL
ALL
MAX.
MIN.
MAX.
1.3
0.2
10
V
V
VD = VDRM RL = 3.3 kΩ TJ = 110°C
IT = 100mA
10
20
mA
400V
600V
30
20
30
20
40
30
dv/dt
VD = VDRM Gate Open TJ = 100°C
TYP.
V/μs
(dv/dt)c
(di/dt)c = 3.2 A/ms TJ = 110°C
TYP.
TYP.
1
2
2
V/μs
μs
tgt
IG = 2 x IGT PW = 15µs IT = 8.5 A(pk)
3.0
3.0
3.2
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — StandardTriac
Value
Symbol
Test Conditions
Quadrant
Unit
Qxx06x4
Qxx06x5
I – II – III
MAX.
TYP.
25
50
50
75
IGT
mA
IV
VD = 12V RL = 60 Ω
VGT
VGD
IH
I – II – III
MAX.
MIN.
MAX.
1.3
V
V
VD = VDRM RL = 3.3 kΩ TJ = 125°C
ALL
0.2
IT = 200mA
50
50
mA
400V
600V
800V
1000V
120
VD = VDRM Gate Open TJ = 125°C
100
85
dv/dt
MIN.
V/μs
VD = VDRM Gate Open TJ = 100°C
(di/dt)c = 3.2 A/ms TJ = 125°C
100
4
(dv/dt)c
TYP.
TYP.
4
V/μs
μs
tgt
IG = 2 x IGT PW = 15µs IT = 8.5 A(pk)
3.0
3.0
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — AlternistorTriac (3 Quadrants)
Value
Symbol
Test Conditions
Quadrant
Unit
Qxx06xH3
Qxx06xH4
IGT
I – II – III
I – II – III
I – II – III
MAX.
MAX.
MIN.
10
35
mA
V
VD = 12V RL = 60 Ω
VGT
VGD
1.3
VD = VDRM RL = 3.3 kΩ TJ = 125°C
0.2
V
IH
IT = 100mA
MAX.
15
75
50
35
mA
400V
600V
800V
400V
600V
800V
1000V
400
300
200
450
350
250
150
Qxx06VHy /
Qxx06DHy
VD = VDRM Gate Open TJ = 125°C
VD = VDRM Gate Open TJ = 100°C
dv/dt
MIN.
75
V/μs
Qxx06LHy /
Qxx06RHy /
Qxx06NHy
50
ALL
(dv/dt)c
(di/dt)c = 3.2 A/ms TJ = 125°C
MIN.
20
25
V/μs
μs
tgt
IG = 2 x IGT PW = 15µs IT = 8.5 A(pk)
TYP.
4.0
4.0
Note: xx = voltage, x = package, y = sensitivity
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
63
Revised: June 24, 2011 04:57 PM
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Static Characteristics
Symbol
VTM
Test Conditions
ITM = 11.3A tp = 380 µs
Value
1.60
20
0.5
50
2
Unit
V
MAX.
MAX.
TJ = 25°C
TJ = 110°C
TJ = 25°C
TJ = 125°C
TJ = 100°C
400 - 600V
400 - 600V
400 - 1000V
400 - 800V
1000V
μA
mA
μA
Lxx06xy
Qxx06xy
mA
μA
IDRM / IRRM
VDRM = VRRM
3
400 - 800V
1000V
10
20
3
TJ = 25°C
Qxx06xHy
TJ = 125°C
TJ = 100°C
400 - 800V
1000V
mA
2
Thermal Resistances
Symbol
Parameter
Value
1.8
Unit
L/Qxx06Ryy / L/Qxx06Nyy
L/Qxx06Lyy
Junction to case (AC)
3.3
3.2
45
°C/W
°C/W
Rθ(J-C)
L/Qxx06Vyy / L/Qxx06Dyy
L/Qxx06Ryy
Junction to ambient
L/Qxx06Lyy
50
Rθ(J-A)
L/Qxx06Vyy
70
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
Figure 2: Normalized DC GateTrigger Current for
All Quadrants vs. JunctionTemperature
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
4.0
3.0
2.0
1.0
0.0
MT2 POSITIVE
(Positive Half Cycle)
MT2
MT2
+
(-)
IGT
GATE
(+)
IGT
GATE
MT1
MT1
REF
REF
QII QI
QIII QIV
IGT
-
+IGT
MT2
MT2
(-)
IGT
GATE
(+)
IGT
GATE
MT1
REF
MT1
REF
-65
-40
-15
10
35
60
85
110
125
-
MT2 NEGATIVE
Junction Temperature (TJ)- °C
(Negative Half Cycle)
NOTE: Alternistors will not operate in QIV
Note: Alternistors will not operate in QIV
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
64
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 3: Normalized DC Holding Current
vs. JunctionTemperature
Figure 4: Normalized DC GateTriggerVoltage for
All Quadrants vs. JunctionTemperature
2.0
1.5
1.0
0.5
0.0
4.0
3.0
2.0
1.0
0.0
-65
-40
-40
10
35
60
85
110
125
-65
-40
-15
10
35
60
85
110
125
JunctionTemperature (T )- °C
Junction Temperature (TJ)- ºC
J
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable CaseTemperature
vs. On-State Current (SensitiveTriac)
120
110
18
16
14
12
10
8
Lxx06Vy
Lxx06Dy
Lxx06Ry
100
90
Lxx06Ly
6
80
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
4
2
0
70
60
CONDUCTION ANGLE: 360°
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
0
2
4
6
8
10
12
14
16
0
1
2
3
4
5
6
7
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable CaseTemperature
vs. On-State Current (StandardTriac)
Figure 8: Maximum Allowable CaseTemperature
vs. On-State Current (AlternistorTriac)
130
130
120
Qxx06RHy
Qxx06NHy
120
Qxx06VHy
Qxx06DHy
Qxx06Ry
Qxx06Ny
110
110
100
100
Qxx06LHy
Qxx06Ly
90
90
80
80
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CONDUCTION ANGLE: 360°
70
60
70
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
CASETEMPERATURE: Measured as shown
on Dimensional Drawings
60
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
65
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 9: Maximum Allowable AmbientTemperature
vs. On-State Current (Sensitive / StandardTriac)
Figure 10: Maximum Allowable AmbientTemperature
vs. On-State Current (AlternistorTriac)
120
100
80
120
100
Qxx06LHy
Qxx06RHy
Qxx06NHy
Lxx06Ly
Lxx06Ry
80
60
40
20
Qxx06Ly
Qxx06Ry
Qxx06Ny
Qxx06VHy
L/Qxx06Vy
60
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
40
CONDUCTION ANGLE: 360°
CASETEMPERATURE: Measured as shown
FREE AIR RATING – NO HEATSINK
on Dimensional Drawing
20
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current [IT(RMS)] - Amps
Figure 11: On-State Current vs. On-StateVoltage
(Typical)
20
TC = 25°C
18
16
14
12
10
8
6
4
2
0
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
Postitive or Negative Instantaneous
On-StateVoltage (vT) -Volts
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
66
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 12: Surge Peak On-State Current vs. Number of Cycles (Sensitive / StandardTriac)
100
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Qxx06Ly
Qxx06Ry
Qxx06Ny
Notes:
Lxx06Ly
Lxx06Ry
Lxx06Vy
Lxx06Dy
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
10
1
1
10
100
1000
Surge Current Duration- Full Cycles
Figure 13: Surge Peak On-State Current vs. Number of Cycles (AlternistorTriac)
100
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Qxx06LHy
Qxx06RHy
Qxx06NHy
Notes:
Qxx06VHy
Qxx06DHy
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
10
1
1
10
100
1000
Surge Current Duration- Full Cycles
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
67
Revised: June 24, 2011 04:57 PM
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Soldering Parameters
Reflow Condition
-Temperature Min (Ts(min)
Pb – Free assembly
tP
TP
)
150°C
Ramp-up
TL
TS(max)
Pre Heat -Temperature Max (Ts(max)
)
200°C
tL
-Time (min to max) (ts)
60 – 180 secs
Ramp-down
Preheat
Average ramp up rate (LiquidusTemp)
(TL) to peak
5°C/second max
TS(min)
tS
TS(max) toTL - Ramp-up Rate
5°C/second max
217°C
-Temperature (TL) (Liquidus)
Reflow
25
time to peak temperature
-Temperature (tL)
60 – 150 seconds
260+0/-5 °C
Time
PeakTemperature (TP)
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
8 minutes Max.
280°C
Time 25°C to peakTemperature (TP)
Do not exceed
Physical Specifications
Environmental Specifications
Test
Specifications and Conditions
Terminal Finish
Body Material
100% MatteTin-plated
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
AC Blocking (VDRM
)
UL recognized epoxy meeting flammability
classification 94V-0
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
Temperature Cycling
Terminal Material
Copper Alloy
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
Temperature/
Humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
HighTemp Storage
Low-Temp Storage
Design Considerations
1008 hours; -40°C
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of theThyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
MIL-STD-750, M-1056
10 cycles; 0°C to 100°C; 5-min dwell-
time at each temperature; 10 sec (max)
transfer time between temperature
Thermal Shock
Autoclave
EIA / JEDEC, JESD22-A102
168 hours (121°C at 2 ATMs) and
100% R/H
Resistance to
Solder Heat
MIL-STD-750 Method 2031
Solderability
Lead Bend
ANSI/J-STD-002, category 3, Test A
MIL-STD-750, M-2036 Cond E
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
68
Revised: June 24, 2011 04:57 PM
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-220AB (R-Package) — Non-Isolated MountingTab Common with Center Lead
T
C MEASURING POINT
AREA (REF.) 0.17 IN2
Inches
Millimeters
Min
O
Dimension
8.13
.320
A
Ø
E
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
P
MT2
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
B
C
13.36
.526
D
7. 01
.276
NOTCH IN
GATE LEAD
TO ID.
NON-ISOLATED
TAB
F
F
G
H
J
R
G
L
H
K
K
N
L
J
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs, (0.904 Nm).
M
MT1 MT2
GATE
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
R
0.97
1.22
Dimensions —TO-220AB (L-Package) — Isolated MountingTab
T
C MEASURING POINT
AREA (REF.) 0.17 IN2
Inches
Millimeters
O
Dimension
8.13
.320
A
Ø
E
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Min
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
P
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
B
C
13.36
.526
D
7. 01
.276
F
F
G
H
J
R
G
L
H
K
K
N
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs, (0.904 Nm).
L
J
MT1 MT2
M
GATE
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
R
0.97
1.22
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
69
Revised: June 24, 2011 04:57 PM
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-263AB (N-Package) — D2-PAK Surface Mount
TC MEASURING POINT
Inches
Millimeters
AREA: 0.11 IN2
C
Dimension
B
V
E
Min
Max
0.370
0.420
0.188
0.035
0.060
0.075
0.105
0.102
0.024
0.110
0.625
0.045
0.010
0.070
Min
Max
9.40
10.67
4.78
0.89
1.52
MT2
A
B
C
D
E
0.360
0.380
0.178
0.025
0.045
0.060
0.095
0.092
0.018
0.090
0.590
0.035
0.002
0.040
9.14
9.65
4.52
0.64
1.14
8.41
.331
7. 01
.276
A
S
W
U
J
K
GATE
MT1
8.13
.320
G
F
1.52
2.41
2.34
0.46
2.29
14.99
0.89
0.05
1.02
1.91
H
D
F
G
H
J
2.67
2.59
0.61
2.79
15.88
1.14
11.68
.460
2.16
.085
K
7. 01
7. 01
.276
.276
S
16.89
.665
8.89
.350
1.40
.055
V
U
W
0.25
1.78
3.81
.150
2.03
.080
6.60
.260
Dimensions —TO-251AA (V-Package) —V-PAKThrough Hole
TC MEASURING POINT
AREA: 0.040 IN2
Inches
Typ
Millimeters
Dimension
Min
Max
Min
1.02
5.97
8.89
5.21
6.48
0.69
2.21
2.16
4.47
0.46
0.97
0.46
1.06
0.86
0.86
1.86
Typ
1.11
Max
1.27
6.22
9.53
5.41
6.73
0.84
2.36
2.41
4.67
0.58
1.12
0.58
1.32
1.11
E
H
J
5.28
.208
MT2
A
D
A
B
C
D
E
F
0.040
0.235
0.350
0.205
0.255
0.027
0.087
0.085
0.176
0.018
0.038
0.018
0.042
0.034
0.034
0.074
0.044
0.242
0.361
0.208
0.262
0.031
0.090
0.092
0.180
0.020
0.040
0.020
0.047
0.039
0.039
0.079
0.050
0.245
0.375
0.213
0.265
0.033
0.093
0.095
0.184
0.023
0.044
0.023
0.052
0.044
0.044
0.084
6.15
9.18
5.29
6.66
0.80
2.28
2.34
4.57
0.51
1.01
0.52
1.20
1.00
1.00
2.00
5.34
.210
B
R
P
Q
S
G
H
I
K
C
J
K
L
MT1
L
F
MT2
GATE
G
P
Q
R
S
I
1.11
2.11
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
70
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-252AA (D-Package) — D-PAK Surface mount
E
6.71
.264
MT2
A
5.28
.208
TC MEASURING POINT
Inches
Typ
Millimeters
Typ
D
Dimension
Min
0.040
0.235
0.106
0.205
0.255
0.027
0.087
0.085
0.176
0.018
0.038
0.018
0.000
0.021
0°
Max
0.050
0.245
0.113
0.213
0.265
0.033
0.093
0.095
0.184
0.023
0.044
0.023
0.004
0.027
5°
Min
1.02
5.97
2.69
5.21
6.48
0.69
2.21
2.16
4.47
0.46
0.97
0.46
0.00
0.53
0°
Max
1.27
6.22
2.87
5.41
6.73
0.84
2.36
2.41
4.67
0.58
1.12
0.58
0.10
0.69
5°
6.71
.264
5.34
.210
A
B
C
D
E
F
0.043
0.243
0.108
0.208
0.262
0.031
0.090
0.092
0.179
0.020
0.040
0.020
0.000
0.026
0°
1.09
B
6.16
2.74
1.60
.063
P
Q
C
5.29
6.65
0.80
2.28
2.33
4.55
0.51
1.02
1.80
.071
GATE
F
AREA: 0.040 IN2
MT1
MT2
3
.118
4.60
.181
G
I
G
H
I
L
O
H
K
J
M
N
J
K
L
0.51
0.00
0.67
0°
M
N
O
P
Q
0.042
0.034
0.047
0.039
0.052
0.044
1.06
0.86
1.20
1.32
1.11
1.00
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
71
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Product Selector
Voltage
Gate Sensitivity Quadrants
Part Number
Type
Package
400V 600V 800V 1000V
I - II - III
5 mA
IV
Lxx06L5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
5 mA
5 mA
5mA
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
AlternistorTriac
AlternistorTriac
StandardTriac
StandardTriac
StandardTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
StandardTriac
StandardTriac
StandardTriac
TO-220L
TO-252 D-PAK
TO-220R
Lxx06D5
Lxx06R5
Lxx06V5
Lxx06L6
5 mA
5mA
5 mA
5 mA
10 mA
10 mA
10mA
10 mA
20 mA
20 mA
20mA
20 mA
TO-251 V-PAK
TO-220L
5 mA
Lxx06D6
Lxx06R6
Lxx06V6
Lxx06L8
5 mA
TO-252 D-PAK
TO-220R
5mA
5 mA
TO-251 V-PAK
TO-220L
10 mA
10 mA
10mA
10 mA
10 mA
10 mA
25 mA
25 mA
25 mA
10mA
35 mA
35 mA
35 mA
35 mA
35 mA
50 mA
50 mA
50 mA
Lxx06D8
Lxx06R8
Lxx06V8
Qxx06VH3
Qxx06DH3
Qxx06L4
Qxx06R4
Qxx06N4
Qxx06RH3
Qxx06LH4
Qxx06RH4
Qxx06VH4
Qxx06DH4
Qxx06NH4
Qxx06L5
Qxx06R5
Qxx06N5
TO-252 D-PAK
TO-220R
TO-251 V-PAK
TO-251 V-PAK
TO-252 D-PAK
TO-220L
TO-220R
TO-263 D²-PAK
TO-220R
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
TO-220L
TO-220R
TO-251 V-PAK
TO-252 D-PAK
TO-263 D²-PAK
TO-220L
TO-220R
TO-263 D²-PAK
Packing Options
Part Number
Lxx06L/Ry
Marking
Lxx06L/Ry
Lxx06L/Ry
Lxx06Dy
Weight
Packing Mode
Bulk
Base Quantity
500
2.2 g
2.2 g
0.3 g
0.3 g
0.4 g
2.2 g
2.2 g
1.6 g
1.6 g
0.3 g
0.3 g
0.4 g
Lxx06L/RyTP
Lxx06DyTP
Tube Pack
Tube
500 (50 per tube)
750 (75 per tube)
2500
Lxx06DyRP
Lxx06Dy
Embossed Carrier
Tube
Lxx06VyTP
Lxx06Vy
750 (75 per tube)
500
Qxx06L/Ryy
Qxx06L/RyyTP
Qxx06NyyTP
Qxx06NyyRP
Qxx06DyyTP
Qxx06DyyRP
Qxx06VyyTP
Qxx06L/Ryy
Qxx06L/Ryy
Qxx06Nyy
Qxx06Nyy
Qxx06Dyy
Qxx06Dyy
Qxx06Vyy
Bulk
Tube Pack
Tube
500 (50 per tube)
500 (50 per tube)
500
Embossed Carrier
Tube
750 (75 per tube)
2500
Embossed Carrier
Tube
750 (75 per tube)
Note: xx = voltage; yy = sensitivity
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
72
Revised: June 24, 2011 04:57 PM
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
TO-252 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.157
(4.0)
0.059
DIA
(1.5)
Gate
MT1
0.63
(16.0)
0.524
(13.3)
*
0.315
(8.0)
*
Cover tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
0.64
(16.3)
Direction of Feed
TO-263 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.63
(16.0)
0.157
(4.0)
Gate
MT1
0.059
(1.5)
DIA
0.945
(24.0)
0.827
(21.0)
*
*
Cover tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
1.01
(25.7)
Direction of Feed
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
73
Revised: June 24, 2011 04:57 PM
Teccor® brandThyristors
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Part Numbering System
Q 60 06 L H4 56
Part Marking System
TO-252AA – (D Package)
TO-251AA – (V Package)
DEVICE TYPE
L : Sensitive Triac
Q
: Triac or Alternistor
LEAD FORM DIMENSIONS
xx : Lead Form Option
VOLTAGE RATING
40 : 400V
60 : 600V
80: 800V
K0 : 1000V
SENSITIVITY & TYPE
Sensitive Triac:
Q6006R5
3
5
6
:
:
:
3 mA (QI, II, III, IV)
5 mA (QI, II, III, IV)
5 mA (QI, II, III)
10 mA (QIV)
M
Y
®
CURRENT
8
:
10 mA (QI, II, III)
20 mA (QIV)
06: 6A
Standard Triac:
4
5
:
:
25 mA (QI, II, III)
50 mA (QI, II, III)
PACKAGE TYPE
L : TO-220 Isolated
Alternistor Triac:
H3
H4
R : TO-220 Non-Isolated
:
:
10 mA (QI, II, III)
35 mA (QI, II, III)
N: TO-263 (D2
PAK)
V : TO-251 (VPAK)
D : TO-252 (DPAK)
MY
®
Lxx06xx & Qxx06xx & Qxx06xHx Series
©2011 Littelfuse, Inc
74
Revised: June 24, 2011 04:57 PM
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.