LDC0500 [LITTELFUSE]
Electric Fuse, Time Delay Blow, 500A, 600VAC, 600VDC, 200000A (IR), Inline/holder,;型号: | LDC0500 |
厂家: | LITTELFUSE |
描述: | Electric Fuse, Time Delay Blow, 500A, 600VAC, 600VDC, 200000A (IR), Inline/holder, |
文件: | 总2页 (文件大小:145K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
POWR-PRO® Fuses
LDC Series POWR-PRO® Class L Fuses
600 V AC/DC Time-Delay • 150 – 2000 Amperes
constants. This makes the fuse uniquely suited for applications such
as crane rail circuits and mass transit systems. Contact the factory for
application information.
For AC only systems, consider the use of POWR-PRO KLPC series
fuses. They have a full 10 seconds time-delay at 500% rated current,
and have a wider range of ratings.
Applications
UPS protection, especially for large battery circuits
DC distribution
DC variable speed drives
Protection of crane rail circuits and other large DC equipment such as
electrical power shovels, ship and dock cranes, etc.
Mass transit systems, including new light rail applications
General purpose AC/DC circuits for mains, feeders, and branch circuits
Features/Benefits
•
•
•
600 Volt AC/DC rated — “All-purpose” Class L fuses reduce
inventory requirements because the need for separate AC and DC
fuses is eliminated.
UL Listed 200,000 A.I.R. AC – 50,000 A.I.R. DC — Reliable
interruption of all overcurrents up to their ratings. Minimizes the need
for time consuming and expensive short-circuit studies.
Moderate time-delay — Four seconds time-delay at 500% current
provides adequate time-delay for many AC applications and most
DC applications. They will withstand most harmless overloads or line
surges. If your needs exceed the LDC capabilities, consider the use
of KLPC fuses for AC applications.
Littelfuse POWR-PRO LDC series Class L fuses represent another
first in fuse protection. LDC series fuses are the first UL Listed 600
volts AC and DC Class L fuses. Since they may be used for both
AC and DC, they eliminate the concern that AC only fuses may be
inserted into DC circuits.
•
•
Selective coordination — LDC series fuses coordinate well with all
Littelfuse fuses rated 600 amperes or less. A combination of LDC
and IDSR series fuses provide a complete 600 volt rated DC system.
Extremely current-limiting — Maximum current limitation reduces
damage to circuits and equipment under short-circuit conditions.
Stops damaging short-circuits faster than any mechanical protective
device.
While LDC series fuses UL Listed DC interrupting rating is more than
adequate for most applications (50,000 amperes at a 16 millisecond
time constant), tests in our high power laboratory have shown that
this remarkable fuse is capable of performing at much longer time
Specifications
Ampere Ratings
Voltage Ratings:
AC: 600 Volts
DC: 600 Volts
AC: 200,000 amperes rms symmetrical
DC: 50,000 amperes
(16 millisecond time-constant)
150 – 2000 amperes
Standard 248-10, Class L
UL Listed 601 – 2000 amps (File No: E81895)
UL Recognized 150 – 600 amps
(File No: E71611)
CSA Certified 150 – 2000 amps
(File No: LR29862)
150
200
250
300
350
400
450
500
600
601
650
700
750
800
900
1000
1100
1200
1300
1350
1400
1500
1600
1800
1900
2000
Interrupting Ratings:
Ampere Range:
Approvals:
Example part number (series & amperage): LDC 1200
Dimensions
Please refer to the KLPC dimensions
© 2005 Littelfuse POWR-GARD™ Products Catalog
w w w . l i t t e l f u s e . c o m
ꢀ3
•
POWR-PRO® Fuses
LDC Series POWR-PRO® Class L Fuses
600 V AC/DC Time-Delay • 150 – 2000 Amperes
Current-Limiting Effects of LDC (600V) Fuses
Apparent RMS Symmetrical for Various Fuse Ratings
Short-Circuit Current*
ꢂ00A
5,000
ꢃꢀ00A
5,000
ꢃꢄ00A
5,000
ꢀ000A
5,000
5,000
ꢃ0,000
ꢃ5,000
ꢀ0,000
ꢀ5,000
30,000
35,000
ꢁ0,000
50,000
ꢄ0,000
ꢂ0,000
ꢃ00,000
ꢃ50,000
ꢀ00,000
8,500
10,000
14,000
15,000
16,000
17,000
18,000
19,000
21,000
22,000
24,000
25,000
30,000
32,000
10,000
15,000
19,000
21,000
22,000
23,000
24,000
26,000
28,000
30,000
33,000
38,000
41,000
10,000
15,000
20,000
25,000
26,000
28,000
30,000
32,000
34,000
36,000
40,000
44,000
46,000
9,750
10,500
11,500
12,000
12,500
13,500
14,000
15,000
16,000
18,000
20,000
23,000
* Prospective RMS Symmetrical Amperes Short-Circuit Current
Note:ꢀDataꢀDerivedꢀfromꢀPeakꢀLet-ThruꢀCurves
1000
800
600
1000000
800000
600000
400
300
400000
300000
200
200000
100
80
2000A
1600A
1200A
60
100000
80000
60000
40
30
800A
40000
30000
20
10
8
20000
6
10000
8000
6000
4
3
2
4000
3000
1
.8
2000
.6
.4
.3
1000
800
600
.2
400
300
.1
.08
.06
200
.04
.03
100
.02
.01
AVAILABLE FAULT CURRENT
SYMMETRICAL R. M. S. AMPERES
CURRENT IN AMPERES
ꢀꢁ
w w w . l i t t e l f u s e . c o m
© 2005 Littelfuse POWR-GARD™ Products Catalog
•
相关型号:
LDC0650
Electric Fuse, Time Delay Blow, 650A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
LDC0700
Electric Fuse, Time Delay Blow, 700A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
LDC0750
Electric Fuse, Time Delay Blow, 750A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
LDC0900
Electric Fuse, Time Delay Blow, 900A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
LDC1000
Electric Fuse, Time Delay Blow, 1000A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
©2020 ICPDF网 联系我们和版权申明