LDC150 [LITTELFUSE]

Electric Fuse, Time Delay Blow, 150A, 600VAC, 600VDC, 200000A (IR), Inline/holder;
LDC150
型号: LDC150
厂家: LITTELFUSE    LITTELFUSE
描述:

Electric Fuse, Time Delay Blow, 150A, 600VAC, 600VDC, 200000A (IR), Inline/holder

电路保护
文件: 总2页 (文件大小:84K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LDC Series POWR-PRO® Class L Fuses  
600 V AC/DC 150 2000 Amperes  
SPECIFICATIONS  
Voltage Ratings: AC: 600 Volts  
DC: 600 Volts  
Interrupting Ratings:AC: 200,000 amperes rms symmetrical  
DC: 50,000 amperes  
(16 millisecond time-constant)  
Ampere Range:150 2000 amperes  
Approvals: Standard 248-10, Class L  
UL Listed 601 2000 amps (File No: E81895)  
UL Recognized 150 600 amps  
(File No: E71611)  
CSA Certified 150 2000 amps  
(File No: LR29862)  
AMPERE RATINGS  
150  
200  
250  
300  
350  
400  
450  
500  
600  
601  
650  
700  
750  
800  
900  
1000  
1100  
1200  
1300  
1350  
1400  
1500  
1600  
1800  
1900  
2000  
Example part number (series & amperage): LDC 1200  
DIMENSIONS  
Please refer to the KLPC dimensions  
Littelfuse POWR-PRO® LDC series Class L fuses represent  
another first in fuse protection. LDC series fuses are the first  
UL Listed 600 volts AC and DC Class L fuse. Since they may  
be used for both AC and DC, they eliminate the concern that  
AC only fuses may be inserted into DC circuits.  
FEATURES/BENEFITS  
600 Volt AC/DC rated All-purposeClass L fuse  
reduces inventory requirements because the need for  
special fuses is eliminated.  
UL Listed 200,000 A.I.R. AC 50,000 A.I.R. DC —  
While LDC series fusesUL Listed DC interrupting rating is  
more than adequate for most applications (50,000 amperes at  
a 16 millisecond time constant), tests in our high power  
testing laboratory have shown that this remarkable fuse is  
capable of performing at much longer time constants. This  
makes the fuse uniquely suited for such applications as crane  
rail circuits and mass transit systems. Contact the factory for  
application information for special needs such as this.  
For AC-only systems, consider the use of POWR-PRO®  
KLPC series fuses. They have a full ten seconds time-delay  
at 500% rated current, and have a wider range of ratings.  
Reliable interruption of all overcurrents up to their ratings.  
Minimizes the need for time-consuming and expensive  
short-circuit studies.  
Moderate time delay Four seconds time delay at 500%  
current provides adequate time-delay for many AC  
applications and most DC applications. They will withstand  
most harmless overloads or line surges. If your needs  
exceed the LDC capabilities, consider the use of KLPC  
fuses for AC applications.  
Selective coordination LDC series fuses coordinate  
well with all Littelfuse fuses rated 600 amperes or less.  
A combination of LDC and IDSR series fuses provide a  
complete 600 volt rated DC system.  
APPLICATIONS  
UPS protection, especially for large battery circuits  
DC distribution  
Extremely current limiting Maximum current limitation  
reduces damage to circuits and equipment under short-  
circuit conditions. Stops damaging short circuits faster than  
any mechanical protective device.  
DC variable speed drives  
Protection of crane rail circuits and other large DC equipment  
such as electrical power shovels, ship and dock cranes, etc.  
Mass transit systems, including new light rail applications  
General-purpose AC/DC circuits for mains, feeders, and  
branch circuits  
22  
LDC Series POWR-PRO® Class L Fuses  
600 V AC/DC 150 2000 Amperes  
Peak Let-Thru Current**  
for various fuse ratings  
Short Circuit  
*
Current  
800A  
1200A  
1600A  
2000A  
5,000  
10,000  
15,000  
20,000  
25,000  
30,000  
35,000  
40,000  
50,000  
60,000  
80,000  
5,000  
8,500  
9,750  
5,000  
10,000  
14,000  
15,000  
16,000  
17,000  
18,000  
19,000  
21,000  
22,000  
24,000  
25,000  
30,000  
32,000  
5,000  
10,000  
15,000  
19,000  
21,000  
22,000  
23,000  
24,000  
26,000  
28,000  
30,000  
33,000  
38,000  
41,000  
5,000  
10,000  
15,000  
20,000  
25,000  
26,000  
28,000  
30,000  
32,000  
34,000  
36,000  
40,000  
44,000  
46,000  
Current-Limiting Effects  
of LDC (600V) fuses  
* Prospective RMS Symmetrical Amperes Short-Circuit  
Current  
10,500  
11,500  
12,000  
12,500  
13,500  
14,000  
15,000  
16,000  
18,000  
20,000  
23,000  
** Apparent RMS Symmetrical  
Note: Data derived from Peak Let-Thru Curves  
100,000  
150,000  
200,000  
1000  
800  
1000000  
800000  
600000  
600  
400  
300  
400000  
300000  
200  
200000  
100  
80  
2000A  
1600A  
1200A  
60  
100000  
80000  
60000  
40  
30  
800A  
40000  
30000  
20  
10  
8
20000  
6
10000  
8000  
6000  
4
3
2
4000  
3000  
1
.8  
2000  
.6  
.4  
.3  
1000  
800  
600  
.2  
400  
300  
.1  
.08  
.06  
200  
.04  
.03  
100  
.02  
.01  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
CURRENT IN AMPERES  
23  

相关型号:

LDC1500

Electric Fuse, Time Delay Blow, 1500A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LDC151G4418Q-352

Directional Coupler, 1429MHz Min, 1453MHz Max, 0.23dB Insertion Loss-Max,
MURATA

LDC151G7313Q-360

Directional Coupler, 1710MHz Min, 1755MHz Max, 0.42dB Insertion Loss-Max,
MURATA

LDC151G7421Q-359

Directional Coupler, 1710MHz Min, 1785MHz Max, 0.22dB Insertion Loss-Max,
MURATA

LDC151G7424Q-392

Directional Coupler, 1709.5MHz Min, 1784.5MHz Max, 0.2dB Insertion Loss-Max
MURATA

LDC151G8117Q-352

Directional Coupler, 1710MHz Min, 1910MHz Max, 0.25dB Insertion Loss-Max,
MURATA

LDC151G8620Q-359

Directional Coupler, 1750MHz Min, 1980MHz Max, 0.22dB Insertion Loss-Max,
MURATA

LDC151G8820Q-359

Directional Coupler, 1850MHz Min, 1910MHz Max, 0.22dB Insertion Loss-Max,
MURATA

LDC151G8824Q-393

Directional Coupler, 1850MHz Min, 1910MHz Max, 0.2dB Insertion Loss-Max,
MURATA

LDC151G9120Q-359

Directional Coupler, 1850MHz Min, 1980MHz Max, 0.22dB Insertion Loss-Max,
MURATA

LDC151G9520Q-359

Directional Coupler, 1920MHz Min, 1980MHz Max, 0.22dB Insertion Loss-Max,
MURATA

LDC151G9523Q-392

Directional Coupler, 1920MHz Min, 1980MHz Max, 0.2dB Insertion Loss-Max
MURATA