PLED18Q12 [LITTELFUSE]
Electronics Circuit Protection Product Selection Guide; 电子电路保护产品选择指南型号: | PLED18Q12 |
厂家: | LITTELFUSE |
描述: | Electronics Circuit Protection Product Selection Guide |
文件: | 总26页 (文件大小:3032K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CIRCUIT
PROTECTION
SOLUTIONS
Electronics Circuit Protection
Product Selection Guide
A guide to selecting Littelfuse circuit protection
components for electronic applications.
Broadest and Deepest
Portfolio of Product
Backed by Unparalleled
Circuit Protection
Expertise
About this guide
This guide provides a summary of key circuit protection consideration factors, descriptions
of the technologies Littelfuse offers, and product selection tables. It is designed to help you
quickly find a protection solution appropriate to your application.
Topic
Page
Littelfuse Circuit ProtectionTechnologies
2–3
Overcurrent ProtectionTechnologies
Fuses
4–5
6
Fuseholders
PositiveTemperature Coefficient Devices (PTCs)
Overvoltage Suppression Protection
Varistors (MOVs, MLVs)
Gas DischargeTubes (GDTs)
PulseGuard® ESD Supressors
TVS Diodes
7
8
9
9
10–11
TVS Diode Array
SPA® Diodes
12
PLED Light-Emitting Diode (LED) Protectors
SIDACtor® ProtectionThyristors
SwitchingThyristors
13
14–15
16–17
Common Circuit Threats and Protection Solutions
18–19
20–23
Application Solutions by Circuit Type and RelatedThreat
©2013 Littelfuse, Inc.
Specifications descriptions and illustrative material in this literature are as accurate as known at the time of publication,
but are subject to changes without notice. Visit littelfuse.com for more information.
WhY Choose CiRCuit PRoteCtioN
Application Knowledge
Circuit protection devices interrupt overcurrent events and divert
overvoltage transients. They increase safety and enable end
products to survive harsh electrical conditions.
For over 85 years, Littelfuse has maintained a focus on circuit protection,
and we will continue to adapt as technologies evolve. Engineers and
circuit designers around the world have come to rely on Littelfuse
products and application knowledge to support their designs.
Most electrical and electronic equipment require circuit protection
devices. In many cases they must be installed to comply with safety
and performance standards before the end products can be sold
or used.
Global Support
Littelfuse products, application knowledge and technical support are
available around the globe. We offer a network of regional customer
support offices and hundreds of independent authorized distributor
contacts to assist you. Visit www.littelfuse.com/contact-us to find local
support near you.
Beyond this, strategically-selected protection devices will:
• Improve end-product uptime, sustainability and reliability
• Assure low warranty return, repair and replacement costs
• Minimize fire and shock risks and larger damage potential
• Minimize operating dangers and potential liabilities
Standards Compliance Expertise
Most Littelfuse products comply with a wide range of applicable industry
and government guidelines, as well as our own rigorous quality and
reliability criteria. We continually look forward and adapt to changing
requirements, so that our products will comply with industry specific,
national and international standards such as CCC, CSA, IEC, IEEE, ISO,
ITU, Meti, RoHs,Telcordia,TIA and many more.
WhY Choose LitteLFuse
Littelfuse is the global leader in circuit protection solutions.
We are the only company to offer all of the pertinent circuit
protection technologies, with products that can be used in
virtually everything that uses electrical energy.
FoR FuRtheR guidANCe
Littelfuse product representatives will work with you to find circuit
protection technologies that will meet your requirements.
Complementing our wide portfolio of circuit protection products
is a global network of design and technical support expertise.
To address your requirements or questions in detail, please contact
a representative near you (Littelfuse.com/contact-us).
We offer decades of design experience to help you address
application challenges and achieve regulatory compliance.
For reference diagrams, technical articles, and other application
guidance materials to assist in your design processes, please visit
Littelfuse.com/designsupport
Your Single Source
Littelfuse offers an extensive circuit protection product line.
We design forward-thinking, application-specific solutions to
provide assurance that your most demanding requirements will
be met. Our goal is to provide the most complete range of options
so that you will not have to make compromises.
For detailed selection of Littelfuse circuit protection technologies
and their common applications, please visit Littelfuse.com/products
For a library of detailed application guides, please visit
Littelfuse.com/technical-resources/application-designs
Testing Support
To download the most current edition of this brochure and our product
catalogs, please visit Littelfuse.com/catalogs
Littelfuse can help assure that your products will withstand most
common threats repeatedly and will fail safely under extreme
circumstances. We can serve as an independent source to provide
assistance as you design by offering lab testing capabilities for
customer applications. This testing includes industry specific
required power fault and ESD/EFT/lightning surge conditions.
littelfuse.com
Littelfuse
Circuit Protection
Technologies
Key Features
and Protection
Characteristics
TypicalVoltage
Clamping
Speeds
Typical
Mounting/
Size/Packaging
Options
When / Where
Typically Used
Surge Energy
Rating Range
Technology
Capacitance/
Insertion Loss
Overcurrent ProtectionTechnologies:
Completely stop current flow,
which helps to identify faults;
Wide range of options
Ultimate protection for sensitive/
expensive/critical components
Series impedance
measured in nH
Very Extensive Range
of Options
Fuses
Low thru Very High
Low thru High
Not applicable
Not applicable
Resettable; No device
replacement after most
common overcurrent events
Where overcurrent events may
occur often, and continuous uptime
desired
Series resistance
measured in ohms
Surface Mount, Radial
Leaded, Axial Strap
PTCs
Overvoltage SuppressionTechnologies:
Multi-Layer
Varistors (MLVs)
Compact and capable of handling
significant surges for their size
ESD and EFT suppression in
smaller and portable electronics
Miniature
Surface Mount
Low thru Medium
Moderate
High
Capable of withstanding very
high energy transients;
Wide range of options
Metal-Oxide
Varistor (MOVs)
Appliance, industrial and very high
energy suppression applications
Medium thru
Very High
Radial Leaded,
Industrial Terminal
Moderate
Fast
High
Low
Switches that turn to on state and
shunt overvoltage to ground using a
contained inert gas as an insulator
Protection of
telecom equipment
from lightning surges
Surface Mount, Axial
Leaded,
2/3 Lead Radial
GDTs
Medium thru High
Low
Extremely low capacitance;
Fast response time;
Compact size
ESD suppression;
Ultra fast reaction;
Low signal distortion
PulseGuard®
ESD Suppressors
Miniature
Surface Mount
Moderate
Very Fast
Very Fast
Fast
Low
Medium
Low
Shunt function bypasses open
LEDs; ESD and reverse power
protection
PLED LED
Protectors
High brightness outdoor
LED lighting applications
Miniature
Surface Mount
Low
Low capacitance /
low clamping voltage;
Compact size
ESD suppression; Low distortion;
Ideal for I/O interfaces and digital &
analog signal lines
TVS Diode Array
SPA® Diodes
Extensive range of
surface mount options
Low thru Medium
Medium thru High
Medium thru High
Fast response to
fast transients;
Wide range of options
Semiconductor protection;
telecom I/O interfaces, electronics,
industrial equipment
Axial Leaded, Radial
Leaded, Surface Mount
TVS Diodes
High
SIDACtor®
Protection
Thyristors
Specifically designed to
serve stringent telecom/
networking standards
Extensive range of
surface mount and
thru-hole options
Telecom / Datacom and
networking applications
Very Fast
Low
SwitchingTechnologies:
Solid state switches that switch
to low “on” state and control the
flow of current
Extensive range of
surface mount and
thru-hole options
Home appliances, power tools,
outdoor equipment
Power Thyristors
Not applicable
Not applicable
Not applicable
1. Fuses and Holders—
mount holders allow for easy
replacement of the fuse from
outside of the appliance,
perfect for applications that
require replacing the fuse
without opening the appliance
enclosure. (Pages 4-6).
mount configurations, Littelfuse
GDTs respond fast to transient
overvoltage events, reducing
the risk of equipment damage
8. PLED Bypass Protectors—
Specialty silicon devices that
enable LED lighting strings
to continue to function if any
single LED fails as an open
circuit, and also offer ESD and
reverse power protection
(Page 13).
Fuses– Full range including
surface mount, axial, glass or
ceramic, thin-film or Nano2®
style, fast-acting or Slo-Blo®
fuse.
(Page 9)
.
5. PulseGuard® ESD
Clips– Used in applications
that require a fuse to be
Suppressors—Available in
various surface mount form
factors to protect high-speed
digital lines without causing
signal distortion (Page 9).
2. PositiveTemperature
easily mounted to a PCB, but
real-estate is scarce. Clips
are also ideal for high-current
applications, allowing for
better heat management of
the fuse. They are the most
economical solution.
Coefficient Devices (PTCs)—
Provide resettable overcurrent
protection for a wide range of
applications (Page 7).
9. SIDACtor® Protection
Thyristors— Complete line of
protection thyristor products
specifically designed to
suppress overvoltage transients
in a broad range of telecom and
datacom applications
6. TVS Diodes—Suppress
3.Varistors—Multiple forms,
from Metal OxideVaristors
overvoltage transients such as
Electrical Fast Transients (EFT),
inductive load switching and
lightning in a wide variety of
applications in the computer,
industrial, telecom and
Blocks– An alternative solution
to Clips but with easier
(MOVs) andThermally Protected
MOV (TMOV® varistors) that
suppress lightning transient
voltages to Multi-LayerVaristors
(MLVs) designed for applications
requiring protection from various
ESD/EFT transients in computers
and handheld devices as well
as industrial and automotive
applications (Page 8).
(Pages 14–15).
placement on the PC board
during manufacturing. In some
instances, Blocks may provide
insulation to the side ears of
the clips. In addition to being
through-hole, Blocks can also
be screwed or riveted in place.
Holders– The ideal solutions for
those applications that require
the cartridge fuse to be
10. SwitchingThyristors—
Solid-state switches used to
control the flow of electrical
current in applications, capable
of withstanding rated blocking/
off-state voltage until triggered
to the on-state (Pages 16–17).
automotive markets (Pages 10–11).
7.TVS Diode Array –
SPA® Diodes—Designed
specifically to protect analog
and digital signal lines
from electrostatic discharge
(ESD) and other overvoltage
transients such as EFT and
Lightning (Page 12).
4. Gas DischargeTubes
(GDTs)—Available in small
footprint leaded and surface
protected, providing a shock-
safe environment. Panel-
1
2
3
7
9
4
10
8
5
6
littelfuse.com
Overcurrent Protection Technologies
Product
Specifications and
Selection Guide
Fuse PRoduCts
Fuses provide protection by completely stopping the flow of energy to sensitive circuits. If current exceeds the fuse’s operating range, the metal
wire or strip melts safely within an enclosure. Littelfuse offers the most extensive range of fuses available, and for easy replacement of cartridge
fuses Littelfuse offers a wide selection of fuseholders including panel mount, in-line, and surface and thru-hole circuit board mount devices.
See page 6 for fuseholder selection.
Agency
Interrupting
Rating at
Max. Voltage
Rating3
Approvals3
Device Range3
(Operating
Current Options
in Amps)
Max. Voltage
Rating3
(Volts)
Operating
Temperature
Range
Series
Name1
Size2
(Amps)
Surface Mount:
437
438
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1206
0603
1206
0603
1206
1206
1206
1206
1206
0603
0603
0402
2410
2410
2410
2410
4012
1206
4012
4818
4818
4118
4818
4012
4012
•
•
•
•
0.25 - 8
0.25 - 6
1.75 - 8
2 - 6
125 / 63 / 32
32 / 24
32
50
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
440
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Ceramic Chip
-55°C to +150°C
-55°C to +90°C
441
32
50
469
•
1 - 8
24 / 32
32
24 - 63
150
50
501
•
10, 12, 15, 20
0.125 - 5
7
466
•
•
125 / 63 / 32
24
•
•
•
•
•
•
•
•
•
•
429
35
•
•
•
•
•
•
•
468
•
•
0.5 - 3
63 / 32
32
35 - 50
35 - 50
35 - 50
35
•
•
•
•
Thin Film
467
•
0.25 - 5
0.25 - 5
0.25 - 5
0.062 - 15
0.375 - 5
0.062 - 15
0.375 - 12
20, 25, 30, 40
1.0 - 10
0.5 - 5
494
32
435
•
•
32
448
125 / 65
125
35 - 50
50
•
•
•
•
449
•
451 / 453
452 / 454
456
•
125 / 65
125 / 72
125
35 - 50
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
100
50
-55°C to +125°C
Nano2® Fuse
458
•
•
75 / 63
250
443
•
50
464
0.5 - 6.3
1 - 6.3
250
100
100
100
100
60
•
•
•
•
•
465
•
•
250
462
0.500 - 5
0.500 - 3.15
0.5 - 2.0
1.25
350
-40°C to +80°C
-55°C to +125°C
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
485
•
600
•
•
•
•
•
•
•
•
•
461
600
•
Telelink® Fuse
-55°C to +125°C
-55°C to +125°C
461E
154
600
60
OMNI-BLOK®
Fuseholder
•
•
•
•
0.062 - 10.0
0.375 - 5
0.062 - 10
0.375 - 5
0.5 - 2
125
35 - 50
50
*
*
*
*
*
*
*
*
*
*
*
*
154T
157
•
•
•
•
•
125
125
35 - 50
50
157T
159
125
Fuse and Clip
Assemblies
-55°C to +125°C
•
•
600
60
160
0.5 - 5
250
50
PICO® SMF
Fuse
459
•
•
•
•
•
•
•
•
•
•
•
•
•
0.062 - 5
0.5 - 5
125
50 - 300
50
•
•
•
•
•
•
-55°C to +125°C
-55°C to +125°C
-40°C to +125°C
460
125
202
•
0.062 - 5
0.25 - 5
2.0 - 10.0
2.0 - 10.0
250
50
Flat Pak
EBF
203
250
50
446
•
•
350
100
100
447
350
(1) Detailed information about most product series listed here can be found on our web site.
(2) Size for these surface mount items refers to common industry length and width dimensions of the device surface area. Example: 0402 = .04” x .02”
(3) In some cases for these categories the ratings, agency approvals and specifications vary by part number and are presented here as ranges representing the whole series.
Please refer to product data on www.littelfuse.com and in our data sheets for detailed information by part number.
* Please refer to data sheet for detailed specifications.
Device
Range3
(Operating
Current
Options in
Amps)
Agency Approvals3
Europe
Interrupting
Rating at
Max Voltage
Rating3
Max. Voltage
Rating3
(Volts)
Operating
Temperature
Range
Series
Name1
Americas
Asia
(Amps)
Radial Leaded / Socket:
262/268
269
272/278
273/279
274
303
370
372
373
374
382
383
369
385
391
392
395
396
397
398
399
400
804
808
807
•
••
•
••
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.002 - 5
0.002 - 5
0.002 - 5
0.002 - 5
0.002 - 5
0.5 - 5
0.4 - 6.3
0.4 - 6.3
0.5 - 10
0.5 - 10
1 - 10
125
125
125
125
125
125
250
250
250
250
250
300
300
125
65
10,000
10,000
10,000
10,000
10,000
50
35 - 50
35 - 50
50
50
100
50 - 100
50
50
50
25 - 63
100
100
50
50
50
130
150
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
-55°C to +85°C
-55°C to +85°C
-55°C to +70°C
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Micro™
Fuse /
TR3 Fuse
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
TR5®
Fuse
•
•
•
•
•
-40°C to +85°C
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1 - 10
1 - 6.3
0.35 - 1.5
0.125 - 4
0.8 - 6.3
0.05 - 6.3
0.05 - 6.3
0.35 - 1.5
0.125 - 4
0.125 - 4
0.5 - 6.3
0.8 - 6.3
2 - 5
•
•
•
250
125
125
125
65
•
•
•
•
•
•
•
•
•
•
-40°C to +85°C
•
•
•
•
•
•
•
•
•
•
TE5
TE7
•
•
•
•
•
•
•
65
250
250
250
300
•
•
•
•
-40°C to +125°C
-40°C to +85°C
-40°C to +125°C
•
•
•
•
100
100
•
•
•
0.8 - 6.3
•
•
•
•
Axial Leaded / Cartridge:
251
253
275
263
471
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•••
•
•
•
•
•
•
•
•
••
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.062 - 15
0.062 - 15
20 - 30
0.062 - 5
0.5 - 5
125
125
32
250
125
125
125
125
250
250
250
250
350
300DC / 50AC
300DC / 50AC
300DC / 50AC
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PICO®
Fuse /
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
-55°C to +125°C
PICO® II
Fuse Axial
•
•
•
50
50
50
472
473
0.5 - 5
0.375 - 7
0.062 - 15
0.1 - 10
0.1 - 10
0.125 - 5
2 - 6.3
0.125 - 10
0.25 - 7
0.3 - 7
0.25 - 2.5
0.375 - 10
0.25 - 7
0.032 - 15
0.032 - 16
0.2 - 6.3
0.04 - 6.3
0.05 - 16
0.125 - 20
1 - 10
•
•
•
265/266/267
874
•
•
300DC / 50AC
50
50
35 - 50
35 - 63
100
100
35 - 100
35
35 - 500
35 - 400
35 - 150
35 - 100
35 - 63
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
875
876
877
208
209
220
2205
224/225
229/230
217
218
213
219XA
216
215
232
235
233
234
239
285
477
977
312/318
313/315
314/324
322
332
325/326
505
•
•
3.6x10 mm
-55°C to +125°C
-55°C to +125°C
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
350
4.5x14.5
mm
(2AG)
Special Fuse
250 / 300 / 350
250
250 / 125
250 / 125
250
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
250
250
250
250
150
•
•
750 - 1500
400 / 1500
300 / 10,000
35 - 10,000
10,000
•
•
•
•
•
•
•
•
250
•
250 / 125
250 / 125
125
250
250 / 125
250
400DC / 500AC
450DC / 500AC
250 / 32
250 / 125 / 32
250
65
250
250
450 / 500
600DC
5x20
mm
-55°C to +125°C
0.1 - 7
1 - 10
1 - 10
•
•
•
•
•
•
•
•
•
•
100 - 200
35 - 10,000
400 - 1500
100 - 1500
200 / 100
35 - 300
35 - 300
35 - 1000
200 - 1000
100 / 200
100 - 600
20,000 - 50,000
10,000
•
•
•
•
0.08 - 7
0.125 - 20
0.5 - 16
0.5 - 16
0.062 - 35
0.01 - 30
0.375 - 40
12 - 30
•
•
•
•
•
••
••
••
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1- 10
0.01 - 30
10 - 30
•
•
•
•
•
•
•
•
6.3x32 mm
(3AG/3AB)
-55°C to +125°C
•
•
•
•
•
506
•
15 - 20
1000VAC / DC
High Voltage
Fuse
508
•
•
0.315 - 1
1000
10,000
•
•
•
•
•
littelfuse.com
Overcurrent Protection Technologies (continued)
FusehoLdeR seLeCtioN guide
Circuit Connection Method
Wire
Wire Connector Terminals
TH= Thru-Hole SM= Surface Mount CT= Wire Connector Terminal QC= Quick Connect
Circuit Board Mount
In- Line
Fuseholders
Panel Mount
Fuse Enclosures
Fuseholder Type
Fuse Blocks
Fuse Clips
Fuse Enclosures
3452 series Int. Shocksafe
345 series Int. Shocksafe ( old )
245001 Solder QC
CT
TH
TH
QC
254 011 - 008
254 101, 254 121
254 131
TH
SM
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
TH
111501
111505
150274
150300
150307
150308
4.5x14.5
208 / 209
mm
111506
225 / 229
(2AG)
245002 Nema QC
254 201 - 208
111510
286377 Fip Top
111512
345 Shocksafe
TH
TH
TH
TH
TH
345121 Shocksafe
4450718 / 595 / 596
598 / 652
TH
TH
TH
QC
CT
354252
445073
100 / 111 Series
04450001 / 00300210
5200001
3455 Int. Shocksafe
286677 Flip Top
520 002, 520 101
520 003, 520 005
520 004
150274
150300
150307
150308
150315
150316
150317
150318
150319
PTF0080M
FH503
800 / 801 / 802 / 821 Series
823 Series Snap-in
810 / 811 / 813 / 814
830 / 831 / 834
852 / 853 / 862
PTF045 / PTF050
52000001009
52100001009
51900001009
51800001009
523 Series
445 Series
NY61AP
213 / 215
216 / 217
218 / 219XA
824 / 824 - 20 / 850 / 851 / 860 series TH
TH
CT
646 / 649 / 656
647
870 Series Medical Grade
TH
5x20
mm
232 / 233
234 / 235
239 / 285
377 / 477
617 / 618
820/ 820-20 Series Mini Shocksafe
SM
658
601
445
CT
PTF010 / PTF020
PTF030 / PTF035 / PTF040
TH
TH
TH
PTF015 / PTF065
PTF075 / PTF077
PTF078
OCT136
FC51
PTF055 / PTF070
FH02A
FB55 / FB58
354 Series
35406
3453 Series Int. Shocksafe
345 Series Int. Shocksafe (old)
342 Series Traditionalf
TH
TH
TH
TH
TH
TH
345101 Shocksafe
810 Series
CT
QC
QC
QC
CT
CT
QC
QC
QC
QC
CT
CT
CT
CT
TH
TH
TH
TH
TH
TH
TH
CT
TH
TH
101001 / 101002
101003 / 102064
121001 / 121002
121003 / 121004
102071
811 Series
35408
813 Series
35409
342006 Watertight
312
313
314
322
326
332
373
505
506
508
605
814 Series
356 Series
359 Series
OMN002
344 Series Snap / Panel Mount
348 Series Snap Mount
862 Series
102076 / 102078
102079 / 102080
122083 / 122087
122088 / 122093
122090 / 100058
51800001009
101010
155 Series
150322
445
PTF080
LH61A800
FH602 / FH604
340 Series RF Shielded / Watertight
346877 Flip Top
OMN004
6.3x32
mm (3AB/3AG)
OMN006
342021 (FHN26W) Water Tight
342024 (FHN26G2) Drip Proof
342025 (FHN20G) Drip Proof
800 Series Shocksafe
FB65 / FB66
102074
10207101009
030201
801 / 802 / 803-01 Series
0CT136
860 Series
570 Series
TH
TH
SM
TH
TH
571 0000 000
559 / 560 / 562 Series
564 Series
303 / 369
370 / 372
373 / 374
382 / 383
385 / 392
395 / 396
397 / 398
400 / 662
663 / 664
665 / 804
807 / 808
576 Series
TE5 /
556 / 557
TR5® Fuse
282001 Front mt. Neoprene
282007 Front mt. Conductive
282002 Rear mt. Neoprene
282008 Rear mt. Conductive
280004 32V indicating
TH
281005 Vertical Silver
TH 281007 Horizontal Silver
262 / 268
269 / 272
273 / 274
278 / 279
Micro™ Fuse
/ TR3
TH
TH
281008 Vertical Tin
281010 Horizontal Tin
PtC PRoduCts
PTCs (positive temperature coefficient) increase resistance as temperature increases. They are designed to prevent unsafe
levels of current while allowing constant safe current levels, and their resistance will “reset” automatically when the current and
temperature returns to a safe level. PTCs are typically used in applications where automatic reset is desired.
Agency Approvals
Operating
Temperature
Range
Max Voltage
(VMAX
Max Fault
current (IMAX)
Series Name1
Size2
Hold Current (IHOLD
)
)
Surface Mount:
0402
0603
0805
1206
1812
2920
0.1 - 0.5A
0.5 - 2.0A
0.75 - 3.0A
0.75 - 4.5A
1.9 - 3.7A
7.0A
LoRho PTC
(Low Resistance)
•
•
6 / 12 V
50 A
•
•
•
•
•
•
0603
(1608)
0603L
0805L
1206L
1210L
1812L
2016L
2920L
250S
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.04 - 0.5A
0.10 - 1.10 A
0.10 - 2.0A
0.05 - 2.0A
0.1 - 3.0A
6 - 15 V
6 - 15 V
6 - 30 V
6 - 30 V
6 - 60 V
6 - 60 V
6 - 60 V
60 V
40 A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0805
(2012)
100 / 40 A
100 A
1206
(3216)
-40°C to 85°C
1210
(3225)
10 / 100 A
1812
(4532)
10 / 20 / 100 A
20 / 40 A
10 / 40 A
3 A
2016
(5041)
0.30 - 2.00 A
0.30 - 3.00 A
0.13 A
2920
(7351)
see data sheet
Radial Leaded:
USBR
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.75 - 2.50 A
2.50 - 14.00 A
0.90 - 9.00 A
0.10 - 3.75 A
0.20 - 3.75 A
0.08 - 0.18 A
0.15 - 0.16 A
6 / 16 V
16 V
40 A
100 A
40 A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
16R
30R
60R
72R
250R
30 V
see data sheet
60 V
40 A
-40°C to 85°C
72 V
40 A
250 V
600 V
3 / 10 A
3 A
600R
Battery Strap:
SL
•
•
see data sheet
1.9 - 3.7 A
6 V
50 A
-40°C to 85°C
•
•
•
•
•
•
(Low Resistance)
(1) Detailed information about most product series listed here can be found on our web site.
(2) Size for these surface mount items refers to common industry length and width dimensions of the device surface area. Example: 0402 = .04” x .02”
littelfuse.com
Overvoltage Suppression Protection
VARistoR PRoduCts
Shorthand for “Variable Resistors,” Varistors possess characteristics that divert transient currents away from sensitive components.
Littelfuse offers two types: Miniature surface mount Multi-Layer Varistors (MLVs) for small electronics applications and Metal Oxide
Varistors (MOV) for higher energy applications.
Agency Approvals
Operating
AC Voltage DC Voltage
Range
Operating
Operating
Temperature
Range
Technology
Type
Peak Current Peak Energy
Lines
Mount/
Series Name1
Disc Size
Range2 (A)
Range (J)
Protected Form Factor
Range
Surface Mount MLV / MOV:
MHS
•
•
•
•
•
•
•
•
•
•
9 - 42
18
30 - 135
18
300
•
•
•
•
•
MLE
22 - 28
4 - 500
Multi-Layer
Zinc Oxide
(MLV)
1
ML
2.7 - 107
5.5 - 120
18
0.02 - 2.5
-55 to
+125°C
AUML
MLN
Surface
Mount
Not
Applicable
18
5.5 - 18
30
0.05 - 0.10
1.0 - 8.0
4
1
CH
•
•
14 - 275
18 - 369
100 - 250
•
•
Zinc Oxide
(MOV)
SM7
•
•
•
•
115 - 510
20 - 320
369 - 675
26
1200
6500
23 - 40
165
•
•
•
•
•
•
•
•
-55 to +85°C
SM20
Radial Leaded MOV:
UltraMOV™
Varistor
UltraMOV™ 25S
Varistor
7, 10, 14
20mm
•
•
•
130 - 625
170 - 825 1750 -10000 12.5 - 720
•
•
•
•
•
•
•
•
•
•
115 - 750
130 - 660
150 - 970
22000
230 - 890
25mm
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Zinc
Oxide
Radial
Leaded
-55 to +85°C
1
C-III
LA
•
•
•
•
3500 - 9000
40 - 530
11 - 360
10, 14, 20mm •
7, 10, 14
•
130 - 1000 175 - 1200 1200 - 6500
•
•
20mm
5, 7, 10, 14,
20mm
ZA
•
•
4 - 460
5.5 - 615
50 - 6500
0.1 - 52
•
•
•
•
•
Industrial High EnergyTerminal MOV:
•
•
•
•
50000
70000
BA/BB
•
130 - 2800 175 - 3500
450 - 10000
270 - 1050
60mm
40mm
•
•
•
•
Screw /
Clip
Terminals
DA/DB
•
130 - 750
130 - 750
175 - 970
175 - 970
40000
•
•
25000
40000
HA
•
•
•
200 - 1050
270 - 1050
32, 40mm
34mm
•
•
•
•
•
Zinc
Oxide
-55 to +85°C
1
Industrial
Packaged
Radial Leads
HB34,
HG34, HF34
130 - 750
175 - 970
40000
•
•
•
•
•
•
•
•
20000
70000
20000
70000
DHB34
CA
•
•
•
•
250 - 2800 330 - 3500
250 - 2800 330 - 3500
330 - 10000
330 - 10000
34mm
60mm
•
•
Bare Disc
Specialty Application MOV:
Not
Applicable
Not
Applicable
MA
•
•
9 - 264
13 - 365
40 - 100
0.06 - 1.7 -55 to +85°C
Axial Leaded
•
•
•
•
•
-55 to
0.4 - 160
Inline Radial
Leads
Zinc Oxide
1
RA
•
•
•
4 - 275
5.5 - 369
4 - 675
100 - 6500
100 - 6500
•
•
+125°C
High Reliability
130 - 510
0.4 - 190
-55 to +85°C
(Varies)
(Varies)
•
Thermally Protected MOV:
Industrial
Packaged
Radial Leads
Industrial
Packaged
Radial Leads
Industrial
Packaged
Radial Leads
TCMOV® 34S
Varistor
•
115 - 550
115 - 750
115 - 750
115 - 750
150 - 700
150 - 970
150 - 970
150 - 970
150 - 970
50000
20000
40000
20000
40000
280 - 960 -45 to +75°C
170 - 670 -45 to +75°C
280 - 1200 -45 to +75°C
170 - 670 -55 to +85°C
235 - 1050 -55 to +85°C
34mm
25mm
34mm
25mm
•
•
•
•
•
•
•
•
SMOV™ 25S
Varistor
•
•
•
•
•
•
•
SMOV™ 34S
Varistor
Zinc Oxide
1
TMOV® 25S
Varistor
Radial
Leaded
•
•
Industrial
Packaged
Radial Leads
TMOV® 34S
Varistor
•
•
115 - 750
115 - 750
34mm
•
•
•
•
•
•
•
•
TMOV® Varistor /
iTMOV® Varistor
•
•
Radial
Leaded
150 - 970 6000 - 10000
35 - 480
-55 to +85°C
14, 20mm
•
(1) Detailed information about most product series listed here can be found on our web.
(2) Not an applicable parameter for Crowbar devices
gdt PRoduCts
GDTs (gas discharge tube) dissipate voltage transients through a contained plasma gas. They have high insulation resistance plus low
capacitance and leakage to ensure minimal effect on normal operation of equipment. Littelfuse devices offer a small footprint and are available
in leaded and surface mount configurations, with high surge handling capability. Their fast response to transient over-voltage events, and ability
to dissipate large amounts of energy, translates into reduced risk of equipment damage. The amount of energy they can dissipate makes them a
good choice for lightning surge protection, particularly for telecom equipment located in outdoor structures.
Mounting Options
DC Breakover
Voltage Range
(Nom VBO)
Peak Pulse
Current
(8/20µs)
Series
Name1
Max AC
Surge Rating
Max
Operating
Capacitance Temperature Range
HighVoltage GDTs:
AC
•
•
•
285 - 600
5000A
5000A
1.5pF
2
2
•
•
•
•
NA
-40°C to +90°C
1.5pF
CG3
•
1000 - 7500
Low to Medium Surge GDTs:
CG5
•
•
•
•
•
•
•
•
•
•
90 - 600
90 - 600
75 - 600
90 - 500
75 - 600
5A
5A
5000A
5000A
5000A
10,000A
5000A
1.5pF
1.5pF
2
2
2
3
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SL0902A
SL1002A
SL1003A
SL1011A
•
•
•
•
5A
1.2pF
1.2pF
1.5pF
-40°C to +90°C
10A*
5A
•
•
Medium to High Surge GDTs:
SG
(1812 Size)
•
•
75 - 420
500 - 750
1.0pF
•
•
•
SL1122A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
90 - 260
90 - 600
90 - 600
90 - 400
75 - 350
75 - 600
90 - 500
75 - 1000
10A*
10A*
10A*
10A*
10A
10000A*
10000A*
10000A*
20000A*
10000A
10000A
20000A*
20000A
100-270pF
1.5pF
3
3
3
3
2
2
3
2
•
•
•
•
•
•
•
•
•
•
•
•
SL1021A
SL1024A
PMT8
•
•
•
•
•
•
•
•
•
•
•
•
1.5pF
-40°C to +90°C
1.5pF
SL1011B
SL1411A
PMT3
1.5pF
•
•
10A
1.5pF
20A*
20A
1.5pF
•
CG/CG2
1.5pF
•
•
Very High Surge GDTs:
SL1021B
SL1024B
SL1026
•
•
•
•
•
•
90 - 600
90 - 600
275 - 700
10A*
10A*
10A*
20000A*
20000A*
20000A*
1.5pF
1.5pF
3
3
2
•
•
•
•
•
•
•
•
•
•
-40°C to +90°C
•
(1) Detailed information about most product series listed here can be found on our web site.
* Total current through center (ground) terminal
PuLseguARd® esd suPPRessoRs
Rated
Single Line Typical Device Leakage Immunity to
Bidirectional
(transients Performs Low
of either
polarity)
Also Rated
for EFT or
Lightning
Series
Array Package
(No. of Lines)
Technology Type Working Voltage
Name
Package
Capacitance Current IEC 61000-4-
2 level 4
Pass Filtering
PulseGuard® ESD Suppressors:
Voltage Variable
Material
Voltage Variable
Material
0402,
0603
0402,
0201
PGB1
•
•
•
0–24VDC
0–12VDC
SOT23 (2)
NA
0.04–0.12pF
0.07pF
<1nA
<1nA
•
•
•
•
PGB2
•
•
•
littelfuse.com
Overvoltage Suppression Protection (continued)
tVs diodes
TVS Diodes are used to protect semiconductor components from high-voltage transients.Their p-n junctions have a larger cross-sectional
area than those of a normal diode, allowing them to conduct large currents to ground without sustaining damage. Littelfuse suppliesTVS
Diodes with peak power ratings from 200W to 30kW, and reverse standoff voltages from 5V to 512V.
Peak Pulse Power
Range†
Peak Pulse
Current
(IPP 8/20μs)
Operating
Temperature
Reverse Standoff Voltage
(VR)
Series Name
Photo
Package Type
(PPP)
Surface Mount-Standard Application (200–5000W):
SMF
200W
400W
400W
600W
600W
500W
600W
600W
1000W
1500W
1500W
3000W
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SOD-123
DO-214AC
DO-214AC
DO-214AC
5.0 - 54
5.0 - 440
5.8 - 495
5.0 - 12
*
•
SMAJ
P4SMA
SMA6J
SMA6L
SACB
•
•
DO-221AC
DO-214AA
DO-214AA
DO-214AA
DO-214AA
DO-214AB
DO-214AB
DO-214AB
5.0 - 85
*
•
5.0 - 50
-85° to +302° F
(-65° to +150° C)
SMBJ
•
•
•
•
•
•
5.0 - 440
5.8 - 495
5.8 - 136
5.0 - 440
5.8 - 495
5.0 - 170
P6SMB
1KSMB
SMCJ
•
•
•
1.5SMC
SMDJ
5000W
•
•
•
5.0SMDJ
•
•
DO-214AB
12 - 170
Axial Leaded-Standard Application (400–5000W):
DO-41
•
•
•
•
•
•
P4KE
•
•
5.8 - 495
400W
DO-15
SA
•
•
5.0 - 180
500W
500W
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SAC
P6KE
1.5KE
LCE
•
•
•
•
•
•
•
•
•
•
•
•
DO-15
DO-15
DO-201
DO-201
P600
5.0 - 50
5.8 - 512
5.8 - 512
6.5 - 90
600W
-85° to +302° F
(-65° to +150° C)
1500W
1500W
3000W
5000W
3KP
5.0 - 220
5.0 - 250
5KP
P600
Axial Leaded-High Power:
15KPA
15000W
20000W
•
•
•
•
•
•
•
•
P600
P600
17 - 280
20 - 300
-85° to +302° F
(-65° to +150° C)
20KPA
•
•
30KPA
AK1
30000W
•
•
•
•
•
•
•
•
•
•
P600
28 - 288
76
Radial Lead
1000A
3000A
AK3
15 - 430
•
•
•
•
•
Radial Lead
-67° to +347° F
(-55° to +150° C)
AK6
•
•
•
•
•
•
•
•
•
•
Radial Lead
Radial Lead
30 - 430
30 - 430
6000A
AK10
10000A
-67° to +257° F
(-55° to +125° C)
AK15
•
•
•
•
•
Radial Lead
58 - 76
15000A
Remark: "*" UR approval is pending.
tVs diodes (cꢀnꢂꢅnꢈꢁꢇ)
Peak Pulse Power
Range†
Peak Pulse
Current
(IPP 8/20μs)
Operating
Temperature
Reverse Standoff Voltage
(VR)
Series Name
Photo
Package Type
DO-221AC
(PPP)
Automotive Application:
-85° to +302° F
(-65° to +150° C)
TPSMA6L
•
•
•
•
•
10 - 60
600W
*
Remark: "*" UR approval is pending.
Led LightiNg desigN
etheRNet PRoteCtioN
plꢀrꢁ ꢂꢃꢁ laꢂꢁꢄꢂ Led lꢅꢆꢃꢂꢅnꢆ ꢅnꢇꢈꢄꢂry
ꢆꢈꢅꢇꢁ fꢀr prꢀꢂꢁcꢂꢅnꢆ eꢂꢃꢁrnꢁꢂ cꢅrcꢈꢅꢂꢄ
ꢇ ꢁqꢈꢅpmꢁnꢂ frꢀm ꢁlꢁcꢂrꢀꢄꢂaꢂꢅc
cꢃarꢆꢁ (esd), lꢅꢆꢃꢂnꢅnꢆ, pꢀwꢁr faꢈlꢂꢄ
ꢇ ꢀꢂꢃꢁr ꢁlꢁcꢂrꢅcal ꢂranꢄꢅꢁnꢂ ꢂꢃrꢁaꢂꢄ.
anꢇarꢇꢄ, prꢀꢇꢈcꢂ ꢅnfꢀrmaꢂꢅꢀn, cꢅrcꢈꢅꢂ
aꢆramꢄ anꢇ lꢅnkꢄ ꢂꢀ applꢅcaꢂꢅꢀn nꢀꢂꢁꢄ
ꢇ vꢅꢇꢁꢀꢄ ꢈꢄꢅnꢆ ꢂꢃꢅꢄ NeW ꢁ-ꢉꢀꢀk.
scan ꢂꢃꢅꢄ cꢀꢇꢁ
ꢂꢀ vꢅꢁw ꢀꢈr
Led Lꢅꢆꢃꢂꢅnꢆ
dꢁꢄꢅꢆn gꢈꢅꢇꢁ.
scan ꢂꢃꢅꢄ cꢀꢇꢁ
ꢂꢀ vꢅꢁw ꢀꢈr
eꢂꢃꢁrnꢁꢂ
dꢁꢄꢅꢆn gꢈꢅꢇꢁ.
esd PRoteCtioN
usb 3.0 CiRCuit PRoteCtioN
ꢆꢈꢅꢇꢁ fꢀr prꢀꢂꢁcꢂꢅnꢆ ꢁlꢁcꢂrꢀnꢅc cꢅrcꢈꢅꢂꢄ
ꢇ ꢅnꢂꢁrfacꢁꢄ frꢀm ꢁlꢁcꢂrꢀꢄꢂaꢂꢅc
ꢄcꢃarꢆꢁ (esd) ꢈꢄꢅnꢆ tVs dꢅꢀꢇꢁ Arrayꢄ.
rn aꢉꢀꢈꢂ ꢂꢃꢁ kꢁy ꢄꢁlꢁcꢂꢅꢀn
ꢁrꢅa anꢇ ꢂraꢇꢁꢀffꢄ amꢀnꢆ prꢀꢂꢁcꢂꢅꢀn
ꢃnꢀlꢀꢆꢅꢁꢄ fꢀr usb 3.0 ꢇꢁvꢅcꢁꢄ.
ꢁnꢂly ꢈpꢇaꢂꢁꢇ!
scan ꢂꢃꢅꢄ cꢀꢇꢁ ꢂꢀ
vꢅꢁw ꢀꢈr usb 3.0
Cꢅrcꢈꢅꢂ Prꢀꢂꢁcꢂꢅꢀn
Applꢅcaꢂꢅꢀn Nꢀꢂꢁ.
scan ꢂꢃꢅꢄ cꢀꢇꢁ
ꢂꢀ vꢅꢁw ꢀꢈr esd
Prꢀꢂꢁcꢂꢅꢀn
dꢁꢄꢅꢆn gꢈꢅꢇꢁ.
littelfuse.com
Overvoltage Suppression Protection (continued)
tVs diode ARRAY – sPA® diodes
TVS Diode Arrays are designed to protect analog and digital signal lines from electrostatic discharge (ESD), Electrical Fast Transients
(EFT), and lightning-induced surge currents. Offering low dynamic resistance for improved clamping performance, TVS Diode
Arrays are offered in a wide range of industry standard discrete and multi-channel SMD packages. Features of this portfolio include
capacitance as low as 0.4 pF and enhanced ESD capability up to 30kV (contact discharge).
ESD Rating
(Contact
Discharge,
IEC61000-4-2)
Maximum
Clamping Voltage Surge
Working
Voltage
Number of
Channels
Series Name
Photo
Package Type
Capacitance
(tP=8/20µs)
Rating
(tP=8/20µs)
General Purpose ESD Protection (SCR Diode Array):
SP720
SP721
SP723
SP724
SP725
2-30V
2-30V
2-30V
2-20V
2-30V
3pF
3pF
5pF
3pF
5pF
14
6
4kV
4kV
8kV
8kV
8kV
2V @ 1A
2V @ 1A
2V @ 2A
2V @ 1A
2V @ 2A
3A
3A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PDIP
SOIC
6
7A
SOT23
SOIC
4
3A
4
14A
(
):
General Purpose ESD Protection TVS Discretes and Arrays
SC70
SOT23
SOT143
MSOP
2 / 3 / 4 / 5 /
6
SP05
5.5V
30pF
30kV
15kV
N/A
N/A
2A
•
•
•
•
•
•
SC70
SOT553
SOT563
SOT963
SP1001
5.5V
8pF
2 / 4 / 5
8.0V @ 1A
•
•
SP1002
SP1003
SP1004
SP1005
SP1006
SP1007
SC70
6.0V
5.0V
6.0V
6.0V
6.0V
6.0V
5pF
30pF
5pF
1 / 2
8kV
30kV
8kV
9.2V @ 1A
12.0V @ 7A
10V @ 1A
2A
7A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0402 (SOD723)
0402 (SOD882)
1
4
1
1
1
SOT953
1A
0201 (Flipchip)
0402 (SOD882)
30pF
25pF
3.5pF
30kV
30kV
8kV
9.3V @ 1A
8.3V @ 1A
11.2V @ 1A
10A
5A
0201 (µDFN-2)
0201 (Flipchip)
0402 (SOD882)
2A
SP1008
SP1011
0201 (Flipchip)
µDFN-6
6.0V
6.0V
6pF
7pF
1
4
15kV
15kV
10.7V @ 1A
8.7V @ 1A
2.5A
2A
•
•
•
•
•
•
Low Capacitance ESD Protection:
SP3001
SP3002
SP0504S
SC70
6.0V
6.0V
0.65pF
0.85pF
4
4
8kV
9.5V @ 1A
9.5V @ 1A
2.5A
4.5A
•
•
•
•
•
•
SC70
SOT23
µDFN-6
•
•
12kV
SOT23
µDFN-6
SC70
SOT5x3
MSOP10
SP3003
6.0V
0.65pF
2 / 4 / 8
8kV
10.0V @ 1A
2.5A
•
•
•
•
SP3004
SP3010
SP3011
SOT563
µDFN-10
µDFN-14
6.0V
6.0V
6.0V
0.85pF
0.45pF
0.40pF
4
4
6
12kV
8kV
10.0V @ 1A
10.8V @ 1A
11.0V @ 1A
4A
3A
3A
•
•
•
•
•
•
•
•
•
•
•
•
8kV
µDFN-10
µDFN-14
SP3012
5.0V
0.50pF
4 / 6
12kV
6.6V @ 1A
4A
•
•
•
•
SP3021
SP3030
SP3031
SP0524P
0402 (SOD882)
0402 (SOD882)
0402 (SOD882)
µDFN-10
5.0V
5.0V
5.0V
5.0V
0.50pF
0.50pF
0.80pF
0.50pF
1
1
1
4
8kV
13.1V @ 1A
9.2V @ 1A
6.9V @ 1A
6.6V @ 1A
2A
3A
5A
4A
•
•
•
•
•
•
•
•
20kV
10kV
12kV
Lightning Surge Protection:
SRV05-4
SOT23
SOIC
6.0V
3.3V
6.0V
3.3V
3.3V
2.8V
2.8V
70V
2.4pF
16pF
4
2
2
2
2
1
4
2
8
4
4
20kV
30kV
30kV
30kV
30kV
30kV
30kV
30kV
30kV
30kV
30kV
11.5V @ 5A
15V @ 100A
20V @ 100A
17V @ 100A
20V @ 75A
13.9V @ 24A
13.9V @ 24A
12V @ 30A
8.0V @ 10A
6.3V @ 5A
10A
150A
150A
150A
75A
40A
40A
40A
20A
20A
20A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SP03-3.3
SP03-6
•
•
•
•
SOIC
16pF
LC03-3.3
SP2502L
SLVU2.8
SLVU2.8-4
SR70
SOIC
9.0pF
5.0pF
2.0pF
2.0pF
2.0pF
4.4pF
3.5pF
3.5pF
SOIC
SOT23
SOIC
•
•
•
•
•
•
SOT143
MSOP
µDFN-10
µDFN-10
SP4060
2.5V
2.5V
3.3V
SP2504N
SP3304N
7V @ 5A
PLed Light-eꢊittiNg diode (Led) PRoteCtoRs
Littelfuse PLED devices provide added reliability to LED lighting strings. Designed to minimize the impact of losing an entire
LED string due to a single LED failure, PLED devices provide a switching function that will bypass LEDs that go open circuit,
and allow current to flow to the remaining LEDs in the string. PLED devices also offer LED protection against electrostatic
discharge (ESD) and accidental reverse power connection (PLED5 devices only). Designed to serve the needs of high brightness
outdoor LED lighting applications (advertising and traffic signs, roadway/pathway/runway lighting, aircraft and emergency
lighting, etc), PLED devices help assure reliability and lower maintenance costs.
VBR
breakdown
Critical rate of
rise dV/dt
IH
IS
IT@VT
VT and IT
Part Number
PLED6M
Photo
Volts
mAmps
mAmps
Max
Amps
Max
Volts
Max
Volts
Max
Min
5.5
Max
7.5
•
12
70
0.35
1.2
N/A
•
•
PLED6Q12
PLED6S
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6
9
16
18
26
33
•
•
•
•
PLED9Q12
PLED9S
5
100
1.0
1.2
250V/µs
PLED13Q12
PLED13S
PLED18Q12
PLED18S
13
18
VOSR
IOSR
VESD
VAK
VTO
IS
VOS
IS
Reverse
On-State
Voltage
Reverse
On-State
Current
ESD WIthstand
Voltage
(IEC61000-4-2)
Input
Voltage
Turn-On
Voltage
Switching
Current
On-State
Voltage
On-State
Current
Part Number
Photo
Volts
Max
Volts
Typ
mAmps
Max
Volts
Min
Volts
Max
mAmps
Max
mAmps
Max
kV
Min
4.65
Max
5.15
Contact
Air
15
1.3@
1.4@
PLED5Q12
PLED5HT
•
40
38
500
700
500
700
8
8
•
•
•
•
IAK=350mA
IAK=350mA
4.9
20
1.8@
1.8@
•
15
IAK=700mA
IAK=700mA
littelfuse.com
Overvoltage Suppression Protection (continued)
sidACꢂꢀr® PRoteCtioN thYRistoRs
SIDACtor® ProtectionThyristors are designed to suppress overvoltage transients in telecom and datacom equipment, and are able to divert
currents as high as 5000A to ground within nanoseconds of reaching their breakover voltage. Littelfuse offers a wide range of configurations
including DO-214AA, DO214AC, COMPAK (3-Pin DO-214), SOT23-5, QFN, MS-012 and modified MS-013 surface mount,TO-92,TO-218, DO-15,
modifiedTO-220, andTO-220 through-hole package options designed to handle medium to high energy transients.
Peak Pulse Rating:
Standoff
(working)
Voltage (VDRM
Switching Voltage
Series Name
Photo
Package Type
Type
(VS)
)
2/10µs
10/1000µs
8/20µs
Broadband Optimized Protection:
A
C
6 - 25
25 - 40
150A
500A
45A
150A
400A
•
DO-214AA
6 - 320
25 - 400
100A
MC Series
•
•
•
•
•
TO-92
C
6 - 320
25 - 400
500A
100A
400A
A
C
150A
500A
45A
150A
500A
Pin 1-2, 3-2: 6-275 Pin 1-2, 3-2: 25-350
Pin 1-3: 12-550 Pin 1-3: 50-700
Modified TO-220
Modified TO-220
100A
Balanced
MC Series
Pin 1-2, 3-2, 1-3: Pin 1-2, 3-2, 1-3:
C
500A
100A
400A
•
•
•
•
•
•
130-420
180-600
A
B
C
150A
250A
500A
45A
80A
150A
250A
400A
3x3 QFN
3.3x3.3 QFN
MS-013
Q2L Series
•
•
6 - 320
25 - 400
100A
MC Multiport Series
C
6 - 320
220 - 640
220 - 320
8 - 24
25 - 400
300 - 800
300 - 400
15 - 35
500A
100A
400A
A
B
A
B
150A
250A
45A
80A
50A
80A
150A
250A
DO-214AA
DO-15
TwinChip™ Protectors
•
•
•
•
3x3 QFN
F
50A
•
•
SDP Series
•
•
•
•
•
SOT23 - 5
5x6 QFN
B
C
C
G
58 - 320
6 - 320
6 - 75
8
77 - 400
25 - 400
25 - 98
15
250A
500A
500A
45A
80A
100A
100A
18A
250A
400A
400A
50A
•
•
•
•
•
•
•
•
SDP Biased Series
SEP Biased Series
P0080T023G5
5x6 QFN
SOT 23 - 5
Subscriber Line Interface Circuit (SLIC) Protection:
A
C
150A
500A
45A
150A
400A
Fixed Voltage Series
•
•
•
•
•
•
DO-214AA
58 - 160
58 - 160
58 - 160
77 - 200
77 - 200
77 - 200
•
•
•
•
•
•
100A
Fixed Voltage
Twin SLIC Series
Modified
DO-214AA
A
C
150A
500A
45A
150A
400A
Fixed Voltage
Q2L Series
QFN
3.3x3.3
100A
Fixed Voltage
Single Port Series
•
•
•
•
MS-012
MS-012
F
F
58 - 95
77 - 130
77 - 200
120A
120A
30A
30A
100A
100A
•
•
•
•
Fixed Voltage
Enhanced Single Series
58 - 160
A
C
A
C
150A
500A
150A
500A
45A
100A
45A
150A
400A
150A
400A
Fixed Voltage
Multiport Series
•
•
•
•
•
•
•
•
•
•
MS-013
58 - 160
77 - 200
•
•
•
•
•
•
•
•
•
•
Battrax® Protectors
Positive/Negative
Modified
DO-214AA
100A
These devices track their
reference voltages.
Please refer to data sheets
in SIDACtor® Protection Thyristor
catalog or www.littelfuse.com
for detailed information.
Battrax® Protectors
Single Port Negative
MS-013
MS-013
MS-013
C
C
C
500A
500A
500A
100A
100A
100A
400A
400A
400A
Battrax® Protectors
Single Port Positive/Negative
Battrax® Protectors
Dual Port Negative
sidACꢂꢀr® PRoteCtioN thYRistoRs (cꢀnꢂꢅnꢈꢁꢇ)
Peak Pulse Rating:
10/1000µs
Standoff
(working)
Voltage (VDRM
Switching
Voltage (VS)
Series Name
Photo
Package Type
Type
)
2/10µs
8/20µs
Line Circuit Access Switch (LCAS) Protection:
A
C
150A
500A
45A
150A
400A
Asymmetrical
Multiport Series
These products have asymmetric
trigger voltages. See data sheet.
•
•
MS-013
•
•
•
•
100A
A
B
C
150A
250A
500A
45A
80A
100A
150A
250A
400A
Custom LCAS
Discrete Series
•
•
DO-214AA
100 - 230
130 - 290
Baseband Protection (Voice-DS1):
A
B
C
150A
250A
500A
45A
80A
100A
150A
250A
400A
•
•
DO-214AA
DO-214AC (SMA)
TO-92
6 - 320
6 - 320
6 - 320
25 - 400
25 - 400
25 - 400
•
•
•
•
•
A
150A
50A
150A
A
B
C
150A
250A
500A
45A
80A
100A
150A
250A
400A
SIDACtor®
Protection Thyristors
•
•
•
•
•
•
•
A
45A
DO-15
90 - 320
130 - 400
•
•
•
•
B
80A
A
B
C
150A
250A
400A
45A
80A
100A
150A
250A
400A
Pins 1-2,3-2:
25-275
Pins 1-3: 50-550
Pins 1-2,3-2:
40-350
Pins 1-3: 80-700
Modified TO-220
SIDACtor® Protection
Thyristors Multiport
Series
Pins 1-2,3-2,4-5,6-5:
6-320
Pins 1-3,4-6: 12-640
Pins 1-2,3-2,4-5,6-5:
25-400
Pins 1-3,4-6: 50-800
A
C
150A
500A
45A
150A
400A
•
•
•
•
•
•
•
•
MS-013
MS-013
100A
C
130 - 420
180 - 600
500A
100A
400A
•
•
•
•
SIDACtor® Protection
Thyristors Balanced
Series
A
150A
250A
400A
150A
250A
500A
150A
250A
500A
45A
80A
150A
250A
400A
150A
250A
400A
150A
250A
400A
Pins 1-2, 3-2:
130-420
Pins 1-3: 130-420
Pins 1-2, 3-2:
180-600
Pins 1-3: 180-600
B
Modified TO-220
C
100A
45A
A
B
130 - 420
180 - 600
80A
SIDACtor® Protection
Thyristors Balanced
Multiport Series
C
100A
45A
•
•
MS-013
•
•
Asym. A6
Asym. B6
Asym. C6
Pins 1-2,2-3,4-5,5-6:
170-400
Pins 4-6,1-3: 50-270
Pins 1-2,2-3,4-5,5-6:
250-550
Pins 4-6,1-3: 80-340
80A
100A
T10A Series
T10B Series
•
•
•
•
DO-15
A
B
50 - 245
80 - 275
84 - 370
50A
100A
250A
•
•
•
•
DO-201
120 - 360
100A
High Exposure Surge Protection:
Pins 1-2,3-2:
25-275
Pins 1-3: 50-550
Pins 1-2,3-2:
40-350
Pins 1-3: 80-700
Primary Protection
•
•
•
•
Modified TO-220
Modified TO-220
C
C
500A
500A
100A
100A
400A
400A
•
•
•
•
Series
Pins 1-2, 3-2:
130-420
Pins 1-3: 130-420
Pins 1-2, 3-2:
180-600
Pins 1-3: 180-600
Primary Protection
•
Balanced Series
5kA Series
•
TO-218
E
140 - 180
6 - 320
180 - 260
25 - 400
5000A
800A
•
•
•
•
High Surge Current Series
DO-214AA
D
1000A
200A
littelfuse.com
Switching Technologies
sWitChiNg thYRistoRs
SwitchingThyristors are solid state switches that are normally open circuits (very high impedance), capable of
withstanding rated blocking/off-state voltage until triggered to on state. Used for circuit control applications,
Littelfuse offersTriac, QUADRAC® Semiconductors, SCRs, Rectifiers plus AlternistorTriacs for best commutating
and noise immunity. Offered in various and other configurations for a wide range of currents blocking/off-state
voltages, packages, and triggering.
Through-Hole Packages:
Other:
DO-15
TO-92-2L
TO-92-3L
TO-251
TO-220
TO-252
TO-218
TO-263
TO-218X
TO3 Fastpak
Surface Mount Packages:
SOT-89
SOT-223
Compak
DO-214AA
IT(RMS)
VDRM/VRRM
IGT (Q1)
Series
Surface Mount
Through-Hole
Sensitive
Standard
Alternistor
Triac:
LxX8Ex
LxXx
QxX8Ex
QxXx
0.8A
3-25mA
3-5mA
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.8A
1.0A
400-600V
400-800V
LX8
Lx01Ex,LxNx
L01
•
3-25mA
3-10mA
3-25mA
5-50mA
5-50mA
25-50mA
10-50mA
10-80mA
50-80mA
50mA
Qx01Ex,QxNx
1.0A
•
•
•
•
4A
Lxx04xx
Lxx06xx
Lxx08xx
Qxx04xx
Qxx06xx
Qxx08xx
Qxx10xx
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6A
Qxx06xHx
Qxx08xHx
Qxx10xHx
Qxx12xHx
Qxx16xHx
Qxx25xHx
HQ6025xH5
Qxx35xHx
Qxx40xx
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
8A
10A
400-1000V
12A
15A & 16A
25A
Qxx15xx
Qxx25xx
•
•
•
•
•
•
•
•
•
•
25A
600V
30A & 35A
40A
400-800V
400-1000V
50mA
Qxx35xx
QxxxxLT
•
•
50-100mA
•
QUADRAC® Semiconductors:
400-600V
4-15A
QxxxxLTH
•
sWitChiNg thYRistoRs (cꢀnꢂꢅnꢈꢁꢇ)
IT(RMS)
VDRM/VRRM
IGT (Q1)
Series
Surface Mount
Through-Hole
Sensitive
Standard
SCR:
EC103xx
SxSx
0.8A
0.8A
1A
400-600V
400-800V
12 - 500µA
5 - 200µA
10mA
•
•
•
•
•
•
•
•
•
SxX8xSx
•
•
•
Sx01E
SxN1
•
•
1.5A
1.5A
4A
200µA
200µA
TCR22-x
Sx02xS
•
•
•
•
•
•
•
•
•
•
400-600V
50- 500µA
0.2-15mA
Sxx04xSx
Sxx06xSx
•
•
•
•
6A
Sxx06x
•
•
•
•
8A
0.2-15mA
0.2-15mA
20mA
Sxx08xSx
Sxx10xSx
•
•
•
•
Sxx08x
Sxx10x
Sxx12x
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
10A
12A
Sxx15x
Sxx16x
15A & 16A
20A & 25A
30mA
•
•
•
•
•
•
•
•
•
•
400-1000V
Sxx20x
Sxx25x
30-35mA
35A
40A
55A
65A
70A
40mA
40mA
40mA
50mA
50mA
Sxx35x
Sxx40x
Sxx55x
Sxx65x
Sxx70x
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Series
Surface
Mount
Through Hole
Switching VBO
IH
ITSM
static dv/dt
1500V/µs
di/dt
TJ
Standard
High Energy
Multipulse
SIDAC:
Kxxxzy
•
•
DO-15,TO-92 DO-214AA
DO-15,TO-92 DO-214AA
DO-15
79-330V
190-280V
190-260V
200-380V
150mA
150mA
60mA
20A
20A
150A/µs -40 to +125 °C
150A/µs -40 to +125 °C
220A/µs -40 to +125 °C
150A/µs -40 to +125 °C
Kxxx0yH
•
•
•
K2xx0GHU
•
Kxxx1G
•
•
DO-15
120mA
I2t
T
IF(RMS)
IF(AV)
Average
stg
IFSM
Storage
temperature
range
I2t Value for
fusing
Series
Through Hole
TO-220 Isl.
TJ
RMS forward
current
Peak non-repetitive surge current
forward current
Rectifiers:
Dxx15L
•
•
•
single half cycle; f = 50Hz;
single half cycle; f = 60Hz;
Dxx20L
•
15 - 25A
9.5 to15.9A
210 - 508 A2s
-40 to +150 °C
-40 to +125 °C
TJ (initial) = 25°C
188 - 300A
TJ (initial) = 25°C
225 - 350A
Dxx25L
littelfuse.com
Common
CircuitThreats
and Protection
Solutions
Threat or
Typical
Principal
Littelfuse Protection
Circuit Action
Wꢃaꢂ ꢅꢄ ꢂꢃꢁ ꢂꢃrꢁaꢂ ꢀr cꢅrcꢈꢅꢂ
acꢂꢅꢀn ꢂꢃaꢂ may ꢇamaꢆꢁ
ꢄꢁnꢄꢅꢂꢅvꢁ ꢁlꢁcꢂrꢀnꢅcꢄ?
Applications
Protection Criteria
Wꢃaꢂ arꢁ ꢂꢃꢁ cꢃaracꢂꢁrꢅꢄꢂꢅcꢄ
rꢁqꢈꢅrꢁꢇ ꢀf ꢂꢃꢁ
Technologies
Wꢃꢅcꢃ cꢅrcꢈꢅꢂ prꢀꢂꢁcꢂꢅꢀn
ꢂꢁcꢃnꢀlꢀꢆꢅꢁꢄ ꢉꢁꢄꢂ ꢄꢁrvꢁ
ꢂꢃꢁꢄꢁ ꢂypꢁꢄ ꢀf ꢄꢅꢂꢈaꢂꢅꢀnꢄ?
Wꢃaꢂ arꢁ ꢂꢃꢁ ꢂypꢅcal
ꢁnꢇ prꢀꢇꢈcꢂꢄ ꢂꢃaꢂ rꢁqꢈꢅrꢁ
prꢀꢂꢁcꢂꢅꢀn frꢀm ꢂꢃꢅꢄ ꢇamaꢆꢁ?
cꢅrcꢈꢅꢂ prꢀꢂꢁcꢂꢅꢀn ꢂꢁcꢃnꢀlꢀꢆy?
Systems that are grounded and/or
in near proximity to AC power lines
Proper interrupting rating, current
carrying capability and voltage rating
Overcurrent / Ground Faults
Lightning
Fuses and/or PTCs
SIDACtor® Protection Thyristors,
Varistors (MOVs),
TVS Diodes,
Gas Discharge Tubes (GDTs)
Any electronic or electrical equipment
with connections to the
Fast response,
proper switching threshold,
surge current rating
outside environment
PulseGuard® ESD Suppressors,
TVS Diode Array – SPA® Diodes,
Multi-Layer Varistors (MLVs)
PLED Bypass Protectors
Any electronic equipment
with a human interface
Fast response,
high peak voltage rating
Electrostatic Discharge (ESD)
Electrical Fast Transients (EFT)
TVS Diodes,
Fast rise time and recovery
for repetitive pulses
Any system that has inductive loads
Varistors (MLVs and MOVs),
TVS Diode Array – SPA® Diodes
Inductive Load Switching and
Commutative Spikes
Large motors, pumps, compressors,
relays and AC distribution
Varistors (MOVs and MLVs),
GDTs, TVS Diodes
High energy rating
TVS Diode Array – SPA® Diodes,
SIDACtor® Protection Thyristors
Data and Communication Line
Voltage Transients
Ethernet, xDSL, data bus,
telecom, etc.
Fast response,
low load capacitance
Wide range of electrical and
electronic circuits
Proper blocking voltage and current
carrying capacity
Switching Thyristors,
PLED Bypass Protectors
Current Switching / Diversion
oVeRCuRReNt eVeNts
VoLtAge tRANsieNt eVeNts
Excessive current events can lead to catastrophic
failures in electronic circuits. These failures can
result in safety hazards such as fire, shock, or
explosion. Common types of overcurrent
threats include:
Voltage transients are short duration surges or
spikes. Unsuppressed, they may damage circuits and
components, and result in complete system failure.
Below are descriptions of common types of voltage
transients, and technologies to reduce their effects:
ovꢁrlꢀaꢇ
elꢁcꢂrꢀꢄꢂaꢂꢅc dꢅꢄcꢃarꢆꢁ (esd)
Overloads occur when more current is allowed to
flow through a circuit path than it was designed
to carry. This excess current can generate and
accumulate heat and result in complete circuit
destruction and possible fire, electrocution or
explosion. Sources of overload can include:
Damage from ESD is generally caused by the transfer
of static electrical charge from a body to an electronic
circuit. It may result in faulty circuit operation, latent
defects, and even catastrophic failure of sensitive
components. ESD suppressors must have very fast
response times and handle high peak voltages and
currents for short durations. Littelfuse offers a range
of PulseGuard® ESD suppressors, Multi-Layer Varistors
(MLVs) and TVS Diode Array – SPA® Diodes that are
designed to suppress these types of events.
• Construction hazards cutting across power mains
• Equipment failure in the power grid
• Environmental hazards on the power grid
• Short spikes of energy within the circuit as a result
of turning equipment on or off
inꢇꢈcꢂꢅvꢁ Lꢀaꢇ swꢅꢂcꢃꢅnꢆ
Switching of inductive loads, such as those that occur
with transformers, generators, motors, and relays, can
create transients up to hundreds of volts and amps, and
can last as long as 400 milliseconds, affecting both AC
and DC circuits. For these applications, commonly used
suppressor devices include Metal Oxide Varistors (MOVs),
Gas Discharge Tubes (GDTs), and Transient Voltage
Suppression (TVS) Diodes.
sꢃꢀrꢂ Cꢅrcꢈꢅꢂ
Short circuits occur when one conducting path
comes in contact with another conducting path or
with ground, such as may occur due to a loose wire,
insulation breakdown, or contact with water. These
conditions can increase the likelihood of arcs, shock,
or fire hazards.
The principal forms of protection against overcurrent
conditions include fuses and resettable positive
temperature coefficient (PTC) thermistors.
Lꢅꢆꢃꢂnꢅnꢆ inꢇꢈcꢁꢇ tranꢄꢅꢁnꢂ
Most transients induced by nearby lightning strikes
result in an electromagnetic disturbance on electrical
and communication lines connected to electronic
equipment. Devices that protect against these transients
must have a fast response time and must be able to
dissipate a large amount of energy. Littelfuse Metal
Oxide Varistor (MOV), TVS Diodes and GDT products are
typically used to protect against these events. Look to
Littelfuse SIDACtor® Protection Thyristors and TVS Diode
Array – SPA® Diode products for Telecom/Datacom
requirements (see page 22).
Their function is to limit current to acceptable
levels and prevent catastrophic events, and during
acceptable conditions act dormant with a minimal
amount of resistance to the circuit.
Fuses will completely stop the flow of current when
opened, which may be desired with sensitive,
expensive or critical applications.
PTCs offer the ability to re-set for withstanding
most minor, common and recurring overcurrent
events. They will allow safe levels of current to pass
continuously, and during major overcurrent events,
increase in resistance as they heat, to restrict the
flow of current. When the overcurrent event ends,
the device resets to its normal operating state.
Aꢈꢂꢀmꢀꢂꢅvꢁ Lꢀaꢇ dꢈmp
Load dump refers to what happens to the supply voltage
in a vehicle when a load is removed. If a load is removed
rapidly (such as when the battery is disconnected while
the engine is running), the voltage may spike before
stabilizing and damage electronic components. In a
typical 12V circuit, load dump can rise as high as 120V
and take 400 ms to decay—more than enough to cause
serious damage. Littelfuse offers a wide range of TVS
Diode and Multi-Layer Varistor (MLV) products designed
to protect against these types of events.
littelfuse.com
Application
Solutions by
Circuit Type and
Related Threat
CoNsuꢊeR eLeCtRoNiC PRoduCt APPLiCAtioNs
Computers—Server, Notebook, Ultrabook, Desktop
Handheld Portables—Smart Phone, Tablet, eReader, PND/GPS, MP3/PMP, Digital Camera/Camcorder
Consumer A/V Equipment—LCD/LED TV, set top box, DVD player
Peripherals—Scanner, Printer, Monitor, Disk Drive
CircuitType
Function or Threat Standards Littelfuse Product Series
TVS Diode Array
sP05x, sP10xx, sP40xx, LC03, sP72x,
sP03-xx, sLVu2.8, sLVu2.8-4
SPA® Diodes
Medium/Low-Speed
Data Interfaces:
usb 1.1, eꢂꢃꢁrnꢁꢂ, Rs-232,
Rs-485, Kꢁypaꢇꢄ, Aꢈꢇꢅꢀ,
Analꢀꢆ Vꢅꢇꢁꢀ
Varistor (MLV)
ꢊLA, ꢊLe, ꢊLN, ꢊhs
IEC61000-4-2
IEC61000-4-4
ESD, EMI, EFT
SIDACtor® Protection
Thyristors
PxxxxsA/sb/sC, PxxxxQ12/Q22
sꢊF, sꢊAJ, sꢊA6L, sꢊbJ,
sꢊCJ, sꢊdJ
TVS Diodes
Overcurrent
PTCs
0603L, 0805L, 1206L, 1210L, 1812L, 2920L
PulseGuard®
ESD Supressor
Pgb1, Pgb2 - 0201, 0402, 0603
High-Speed
Data Interfaces:
USB 2.0/3.0, HDMI, eSATA,
DisplayPort, DVI, IEEE 1394,
RF Antenna
IEC61000-4-2,
IEC61000-4-4
ESD, EMI, EFT
TVS Diode Array
SPA® Diodes
sP30xx, sP40xx, sP0524P, sP0504s
sL sꢊt sꢁrꢅꢁꢄ 0402L, 0603L, 0805L,
1206L, 1210L, 1812L
sꢊF, sꢊAJ, sꢊA6L, sꢊbJ, sꢊCJ,
sꢊdJ, P4Ke, P6Ke, 1.5Ke
Overcurrent
Lightning
LoRho PTCs
TVS Diode
IEC61000-4-5
Varistor (MOV)
LA, ulꢂraꢊoV™, C-iii, tꢊoV® varꢅꢄꢂꢀrꢄ
Power Inputs:
120/240 VAC
sꢊd: Nanꢀ2®, Fꢈꢄꢁ, PiCo® sꢊd fꢈꢄꢁꢄ
Lꢁaꢇꢁꢇ: 2Ag, 3Ab/3Ag, 5x20, 3.6x10,
tR5®/te5 fꢈꢄꢁꢄ
Overcurrent
Fuse
sꢊF, sꢊAJ, sꢊA6L, sꢊbJ, sꢊCJ,
sꢊdJ, P4Ke, P6Ke, 1.5Ke
TVS Diode
IEC61000-4-2,
IEC61000-4-5
Lightning / ESD
Varistor (MLV)
Varistor (MOV)
ꢊL, ꢊLe
ZA
Power Inputs:
blaꢇꢁ dC ꢅnpꢈꢂ,
Lꢀw vꢀlꢂaꢆꢁ dC,
Lꢅ-ꢅꢀn baꢂꢂꢁry
sꢊd - tꢃꢅn Fꢅlm, Cꢁramꢅc, Cꢃꢅp, Nanꢀ2®
(1206 ꢄꢅzꢁ), 501 (20A), 456 (40A) fꢈꢄꢁꢄ
,
Fuse
Overcurrent
sL sꢊt sꢁrꢅꢁꢄ 0402L, 0603L, 0805L,
1206L, 1210L, 1812L
LoRho PTC
PoWeR ꢊAiNs / AC LiNe PRoteCtioN*
Circuit Type
Function or Threat Littelfuse Product Series
typꢁ 1 (Pꢀwꢁr ꢉꢁfꢀrꢁ ꢂꢃꢁ panꢁl)
Surge Protective Devices (SPD)
(Primary building entrance, electric meters)
tCꢊoV®, sꢊoV™, tꢊoV®, ulꢂraꢊoV™, LA, C-iii, hA, hb34, hF34,
hg34 varꢅꢄꢂꢀrꢄ
Lightning
Varistor (MOV)
Varistor (MOV)
typꢁ 2 (Pꢁrmanꢁnꢂly cꢀnnꢁcꢂꢁꢇ ꢇꢁvꢅcꢁꢄ afꢂꢁr ꢂꢃꢁ panꢁl)
tCꢊoV®, sꢊoV™, tꢊoV®, ulꢂraꢊoV™, LA, C-iii, hA, hb34, hF34,
hg34 varꢅꢄꢂꢀrꢄ
Uninterruptible Power Supply
(commercial/industrial)
Lightning, Switching Transients
TVS Diode
GDT
5KP, 15KPA, 20KPA, 30KPA, AK1, AK3, AK6, AK10, AK15
AC120, AC240
Surge Protective Devices (SPD)
(building level equipment, load-center
panels, datacenters)
Power Fault / Short Circuit and other
themal events
PoWR-gARd® ꢊꢅꢇꢆꢁꢂ fꢈꢄꢁꢄ
LVsP ꢄꢁrꢅꢁꢄ (ꢊoV prꢀꢂꢁcꢂꢅꢀn)
Power Inverters
Fuse
typꢁ 3 (Plꢈꢆ-ꢅn ꢁqꢈꢅpmꢁnꢂ afꢂꢁr ꢂꢃꢁ panꢁl)
Varistor (MOV)
TVS Diode
GDT
tꢊoV®, ulꢂraꢊoV™, LA, C-iii, hA, hb34, hF34, hg34 varꢅꢄꢂꢀrꢄ
5KP, 15KPA, 20KPA, 30KPA, AK1, AK3, AK6, AK10, AK15
Cg3 4.0
Uninterruptible Power Supply
(consumer/residential)
Lightning, Switching Transients
External Power Supplies
(chargers, peripheral devices, etc)
Consumer Electronics
AC Appliances
tꢃrꢈ hꢀlꢁ: tR5® / te5, 2Ag, 3Ag, 5x20, 3.6x10, PiCo® fꢈꢄꢁꢄ
sꢈrfacꢁ ꢊꢀꢈnꢂ: Nanꢀ2®, PiCo® sꢊd fꢈꢄꢁꢄ
Power Fault / Short Circuit and other
themal events
Fuse
AC Power Strips
Switch Mode Power Supplies
LightiNg sYsteꢊs
Circuit Type
Function or Threat Littelfuse Product Series
Improved LED String Reliability
PLED devices
PLedxx
Varistor (MOV)
tꢊoV®, ulꢂraꢊoV™, Ch, LA, C-iii varꢅꢄꢂꢀrꢄ
Power Supply (Lightning, Inductive
Load Switching)
sꢊbJ, P4Ke, P6Ke, 1.5Ke, 5KP, 15KPA, 30KPA,
AK1, AK3, AK6, AK10, AK15
LED Lighting Systems
Light Dimmers
TVS Diode
Fuse
tꢃrꢈ hꢀlꢁ: tR5® / te5, 2Ag, 3Ag, 5x20, 3.6x10, PiCo® fꢈꢄꢁꢄ
Power Fault / Short Circuit and
other themal events
sꢈrfacꢁ ꢊꢀꢈnꢂ: Cꢁramꢅc Cꢃꢅp, Nanꢀ2®, PiCo® sꢊd
(hꢅꢆꢃ Vꢀlꢂaꢆꢁ) 477 ꢄꢁrꢅꢁꢄ, 505 ꢄꢁrꢅꢁꢄ, 808 ꢄꢁrꢅꢁꢄ, 485 ꢄꢁrꢅꢁꢄ fꢈꢄꢁꢄ
trꢅacꢄ / Alꢂꢁrnꢅꢄꢂꢀr trꢅacꢄ: Q6010Lx, Q6016Lx, Q6025Lx
QuAdRAC® ꢄꢁmꢅcꢀnꢇꢈcꢂꢀrꢄ: Q6010Lt, Q6015Lt
Phase Control
Thyrsitor
Overcurrent (Europe)
Lightning
Fuse
Varistor (MOV)
Fuse
3.6x10
LA
Electronic Fluorescent
Lighting Ballasts
Overcurrent
383 tR ꢄꢁrꢅꢁꢄ / 369 tR5® ꢄꢁrꢅꢁꢄ, 446 / 447 ebF fꢈꢄꢁ
Compact Fluorescent Lamps (CFL)
Metal Halide Lighting
Overcurrent
Fuse
3.6x10
Lamp Ignition
Lamp Ignition
Thyristor
Thyristor
ꢊꢈlꢂꢅpꢈlꢄꢁ sꢅꢇac: K2401g
sꢅꢇac: K1200g
High Pressure Sodium Lighting
eLeCtRiC ꢊotoRs*
Circuit Type
Function or Threat Littelfuse Product Series
trꢅac: Q6016Lh4
sCR: s6025L
Rꢁcꢂꢅfiꢁr: d6025L
Universal / DC Motors
(intermittant use)
Speed Control
Thyristor
Speed Control
Thyristor
Varistor (MOV)
TVS Diode
trꢅac: Q6012Lh4
LA, sꢊ20
AC Induction Motors
(continuous use)
Thyristor Overvoltage Protection
sꢊbJ, P4Ke, P6Ke, 1.5Ke
* Littelfuse offers protection solutions to serve a wide range of electric motors, controllers and power systems. Please consult with your Littelfuse products
representative for detailed discussion about your requirements. For higher power and industrial applications, please refer to our POWR-GARD® division
product catalogs (www.littelfuse.com/catalogs).
littelfuse.com
Application Solutions by Circuit Type and Related Threat (continued)
teLeCoꢊ/dAtACoꢊ
Circuit
Threat
Standards Littelfuse Product Series
TVS Diode Array sP05x, sP10xx, sP40xx, sP72x, sP03-xx, sLVu2.8,
SPA® Diodes
sLVu2.8-4
Medium/Low-Speed
Data Interfaces:
usb 1.1, Rs-232, Rs-485,
Kꢁypaꢇꢄ, Aꢈꢇꢅꢀ, Analꢀꢆ
Vꢅꢇꢁꢀ
IEC61000-4-2,
IEC61000-4-4
ESD, EMI, EFT
Varistor (MLV) ꢊL, ꢊLe, ꢊLN, ꢊhs
TVS Diodes
PTCs
sꢊF, sꢊAJ, sꢊA6L, sꢊbJ, sꢊCJ, sꢊdJ
Overcurrent
0805L, 1206L, 1210L, 1812L
PulseGuard®
ESD Suppressor
Pgb1, Pgb2 - 0201, 0402, 0603
IEC61000-4-2,
IEC61000-4-4
High-Speed Data
Interfaces:
USB 2.0/3.0, HDMI, eSATA,
DisplayPort, DVI, IEEE 1394,
RF Antenna
ESD, EMI, EFT
TVS Diode Array
SPA® Diodes
sP30xx, sP40xx, sP0524P, sP0504s
0805L, 1206L, 1210L, 1812L
sg, sL0902A
Overcurrent
Overvoltage
PTCs
GDTs
IEC61000-4-5, GR-1089,
ITU-7 K.12
SLICs
SIDACtor®
Protection
Thyristors
GR-1089, TIA-968-A/B,
ITU K.20/.21/.45,
UL/EN/IEC 60950-1,
UL 497B,
Pxxx1 Fꢅxꢁꢇ Vꢀlꢂaꢆꢁ sLiC Prꢀꢂꢁcꢂꢀrꢄ
(Subscriber Line
Interface Circuits):
CO sites, Remote
Cabinets/Terminals,
VoIP systems,
Lightning
bxxxx baꢂꢂrax® Prꢀꢆrammaꢉlꢁ sLiC Prꢀꢂꢁcꢂꢀrꢄ
Fuses
PTCs
tꢁlꢁLꢅnk® 461
600R150
IEC 61000-4-5,
YD/T-993
Power Fault
FXS ports
SIDACtor®
Protection
Thyristors
Pxxxx sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ
GR-1089, TIA-968-A/B,
ITU K.20/.21/.45,
UL/EN/IEC 60950-1,
UL 497B,
sdP ꢄꢁrꢅꢁꢄ lꢀw prꢀfꢅlꢁ sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ
Lightning
Low-Speed Circuits:
Vꢀꢅcꢁ, Fax, ꢊꢀꢇꢁm,
FXo / dAA
GDTs
Fuses
PTCs
sL0902A, sL1002A, sL1003A, sL1011A, sL1024A
tꢁlꢁLꢅnk® 461 fꢈꢄꢁ
IEC 61000-4-5,
YD/T-993
Power Fault
600R150
PxxxxxxꢊCL sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ
SIDACtor®
Protection
Thyristors
Pxxx2xxꢊCL twꢅnCꢃꢅp™ Prꢀꢂꢁcꢂꢀrꢄ
PxxxxQxx QFN sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ, sdP, seP ꢄꢁrꢅꢁꢄ
lꢀw prꢀfꢅlꢁ sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ, sdP023t
Lightning
GR-1089, TIA-968-A/B,
ITU K.20/.21/.45, UL/EN/
IEC 60950-1,UL 497B, IEC
61000-4-5, YD/T-993
TVS Diode Array sRV05-4, sP4060, sP2504N, sP3304N, sP2502L,
Medium-Speed Circuits:
t1/e1/J1/ds1,
SPA® Diodes
LC03, sP03-xx
t3/e3/ds3
GDTs
sL0902A, sL1002A, sL1003A, sL1011A, sL1024A
tꢁlꢁLꢅnk® 461 / 461e fꢈꢄꢁꢄ
600R150, 250s, 250R
Fuses
Power Fault
Lightning
PTCs
SIDACtor®
Protection
Thyristors
sdP, seP ꢄꢁrꢅꢁꢄ lꢀw prꢀfꢅlꢁ sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ
GR-1089, TIA-968-A/B,
ITU K.20/.21/.45, UL/EN/
IEC 60950-1, UL 497B,
YD/T-993, IEEE 802.3,
IEC61000-4-5
GDTs
sL0902A, sL1002A, sL1003A, sL1011A, sL1024A
Ethernet:
10/100/1000baꢄꢁt
TVS Diode Array sP30xx, sP40xx, LC03, sLVu2.8, sLVu2.8-4, sRV05-4,
SPA® Diodes
sP2504N, sP3304N, sP2502L, sP03A-3.3
Fuses
tꢁlꢁLꢅnk® 461 fꢈꢄꢁ
Power Fault
ESD
PTCs
600R150, 250s, 250R
TVS Diode Array
SPA® Diodes
IEC 61000-4-2
sP30xx, sP0524P, sP0504s
SIDACtor®
Protection
Thyristors
TVS Diode Array
SPA® Diodes
GR-1089, TIA-968-A/B,
ITU K.20/.21/.45,
IEC 61000-4-5,
YD/T-993, IEEE 802.3
sdP sidACꢂꢀr® Prꢀꢂꢁcꢂꢀrꢄ, sdP023t
sR70
xDSL:
AdsL, AdsL2, hdsL,
VdsL, VdsL2
Lightning
UL497
GR-974
UL/EN/IEC 60950-1
Lightning and Power
Fault
sL0902A, sL1002A, sL1003A, sL1011A,
sL1024A, sL1411A, sL1021A, sL1122A
Primary Protection
GDT
TVS Diode
P4Ke, P6Ke, 1.5Ke, AK1, AK3, AK6, AK10, AK15
Lightning
Varistor (MOV) Ch, ZA, ulꢂraꢊoV™ varꢅꢄꢂꢀrꢄ
Power Inputs:
120/240 VAC, ꢈp ꢂꢀ
120 VdC, AtCA
ꢊꢅꢇꢆꢁꢂ sꢁrꢅꢁꢄ (sFe, KlK, KLKd, bLs, bLN, FLQ, FLꢊ,
FLA, KLQ)
Fault Current
Fuse
Faꢄꢂ Acꢂꢅnꢆ: 435, 431/434, 429/433, 271, 446, 445, 451/453,
456, 459
slꢀ-blꢀ® fꢈꢄꢁꢄ: 430, 452 / 454, 461, PiCo® ii fꢈꢄꢁꢄ
AutoꢊotiVe eLeCtRoNiCs*
Engine/Body/Chassis Controllers — Anti-lock brake / steering / air bag / seat belt / collision control and
other safety systems and sensors, lighting / signalling controls, instrument cluster, engine / emission
controllers, window / wipers controls, door lock / security controls, seating sensors and controllers
Multimedia/Information Systems — In-dash stereo / GPS / climate control electronics, portable GPS,
portable CD/DVD/media players, audio / video / data / power docks and inputs
Circuit Type
Function or Threat
Standards
Littelfuse Product Series
PulseGuard® ESD
Suppressor
Pgb1, Pgb2 - 0201, 0402, 0603
High-Speed Interfaces:
USB 2.0, IEEE 1394
ESD
IEC61000-4-2
TVS Diode Array
SPA® Diodes
TVS Diode Array
SPA® Diodes
sP30xx, sP0524P, sP0504s
sP05x, sP72x, sP10xx
Medium/Low-Speed
Interfaces:
ESD, EMI
IEC61000-4-2
USB 1.1, CAN
Varistor (MLV)
ꢊL, ꢊLe, ꢊLN, ꢊhs
RoHS; ISO 7637;
GM 9105; Various UL,
CSA, IEC, MITI
blaꢇꢁ / tꢁrmꢅnal Fꢈꢄꢁ sꢁrꢅꢁꢄ:
257, 297, 298, 299, 495, 498
(ꢄꢁꢁ aꢈꢂꢀmꢀꢂꢅvꢁ prꢀꢇꢈcꢂꢄ caꢂalꢀꢆꢄ)
Fault Currents
Fuse
Power Inputs:
Up to 42 VDC
Varistor (MLV)
AuꢊL, ꢊLA, ꢊLe, ꢊhs
tPsꢊA6L
Load Dump
and Inductive Switching
TVS Diode
(AEC-Q101)
—
Varistor (MOV)
Ch, ZA
* Littelfuse offers a wide range of solutions designed to serve the requirements of automotive, truck, and off-road vehicle applications. Please refer to our automotive
products catalogs (www.littelfuse.com/catalogs) and your Littelfuse products representative for detailed discussion about your requirements.
White goods / APPLiANCes
Circuit Type
AC Induction Motor
Function or Threat Littelfuse Product Series
On / Off / Speed Control
On / Off / Speed Control
On / Off
Switching Thyristor
Switching Thyristor
Switching Thyristor
Varistor (MOV)
Alꢂꢁrnꢅꢄꢂꢀr trꢅac
AC Shaded Pole Motor Fan
eV sꢁrꢅꢁꢄ trꢅac
eV sꢁrꢅꢁꢄ trꢅac
AC Solenoid Valve / Lock
Spike Suppression
DC Supply Protection
ESD Protection
LA
Brushless DC Motor Drive
Display / Touchscreen
TVS Diode
1.5Ke / 1.5sꢊC
Varistor (MLV)
ꢊL
Free-Running Oscillator
Micro-controller Fired
On / Off / Variable
On / Off / Dim
Switching Thyristor
Switching Thyristor
Switching Thyristor
Switching Thyristor
Varistor (MLV)
K2xxxyh sꢁrꢅꢁꢄ sidAC
Gas Ignitor
eC sꢁrꢅꢁꢄ sCR
Heating Element
Incandescent Bulb
LED Indicator / Light
MicroController I/O
Sensor
hQ sꢁrꢅꢁꢄ hꢅꢆꢃ tꢁmp trꢅac
L-sꢁrꢅꢁꢄ trꢅac
ESD Protection
ꢊL
ꢊL
ꢊL
ESD Protection
Varistor (MLV)
ESD Protection
Varistor (MLV)
Carꢂrꢅꢇꢆꢁ 215, 218, 877, PiCo® ii, tR / te 392,
382 fꢈꢄꢁꢄ
AC Input Overcurrent
Input Overvoltage
Output Overcurrent
Output Overvoltage
Fuse
Varistor (MOV)
Fuse
LA
Switch-Mode Power Supply
477, 977, 505 hV dC Carꢂrꢅꢇꢆꢁ, te 808 hV dC,
485 Nanꢀ2® fꢈꢄꢁꢄ
TVS Diode
1.5Ke / 1.5sꢊC
ꢊL
Varistor (MLV)
Touch Keypad
ESD Protection
TVS Diode Array – SPA® Diodes sP10xx
TVS Diode
Varistor (MOV)
1.5Ke / 1.5sꢊC
Triac Control
Overvoltage Protection
On / Off
LA
Wax Motor Latch / Lock
Switching Thyristor
eV sꢁrꢅꢁꢄ trꢅac
littelfuse.com
littelfuse.com
circuitprotection@littelfuse.com
EC102v0413
相关型号: