Q8008DH3 [LITTELFUSE]
Alternistor TRIAC, 800V V(DRM), 8A I(T)RMS, TO-252, DPAK-3;型号: | Q8008DH3 |
厂家: | LITTELFUSE |
描述: | Alternistor TRIAC, 800V V(DRM), 8A I(T)RMS, TO-252, DPAK-3 LTE 栅 三端双向交流开关 栅极 |
文件: | 总14页 (文件大小:765K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
RoHS
Lxx08xx & Qxx08xx & Qxx08xHx Series
Description
This 8 Amp bidirectional solid state switch series is
designed for AC switching and phase control applications
such as motor speed and temperature modulation controls,
lighting controls, and static switching relays.
Sensitive type components guarantee gate control in
Quadrants I & IV as needed for digital control circuitry.
Standard type components normally operate in Quadrants
I & III triggered from AC line.
Alternistor type components only operate in quadrants I, II,
& III and are used in circuits requiring high dv/dt capability.
Agency Approval
Features & Benefits
• RoHS compliant
• No contacts to wear out
from reaction of switching
events
Agency
Agency File Number
• Glass – passivated
junctions
E71639*
• Restricted (or limited) RFI
generation, depending on
activation point of
* - L Package Only
• Voltage capability up
to 1000 V
Main Features
• Surge capability up
to 100 A
sine wave
Symbol
IT(RMS)
Value
Unit
A
• Requires a short gate
activation pulse during
each half-cycle
• The L-package has
an isolation rating of
2500VRMS
8
VDRM/VRRM
IGT (Q1)
400, 600, 800 or 1000
V
5 to 50
mA
• Solid-state switching
eliminates arcing or
contact bounce that
create voltage transients
Schematic Symbol
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, light
dimmers, power tools, home/brown goods and white
goods appliances.
MT2
MT1
AlternistorTriacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
G
Additional Information
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
Datasheet
Resources
Samples
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Absolute Maximum Ratings — SensitiveTriac (4 Quadrants)
Symbol Parameter
IT(RMS)
Value
Unit
Lxx08Ly
TC = 80°C
TC = 85°C
t = 20 ms
t = 16.7 ms
RMS on-state current (full sine wave)
8
A
Lxx08Ry / Lxx08Vy / Lxx08Dy
f = 50 Hz
65
85
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
f = 60 Hz
I2t
I2t Value for fusing
tp = 8.3 ms
f = 120 Hz
26.5
70
A2s
Critical rate of rise of on-state current
IG = 50mA with 0.1µs rise time
di/dt
A/μs
TJ = 110°C
IGTM
PG(AV)
Tstg
TJ
Peak gate trigger current
Average gate power dissipation
Storage temperature range
tp=20μs
4
A
TJ = 110°C
TJ = 110°C
0.4
W
°C
°C
-40 to 150
-40 to 110
Operating junction temperature range
Note: xx = voltage/10, y = sensitivity
Absolute Maximum Ratings — StandardTriac
Symbol
Parameter
Value
Unit
Qxx08Ry / Qxx08Ny
Qxx08Ly
TC = 95°C
TC = 90°C
IT(RMS)
RMS on-state current (full sine wave)
8
A
A
f = 50 Hz
f = 60 Hz
t = 20 ms
83
100
41
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
t = 16.7 ms
I2t
I2t Value for fusing
tp = 8.3 ms
A2s
Critical rate of rise of on-state current
di/dt
f = 120 Hz
tp=20μs
70
A/μs
TJ = 125°C
IG = 200mA with ≤ 0.1µs rise time
IGTM
PG(AV)
Tstg
TJ
Peak gate trigger current
Average gate power dissipation
Storage temperature range
4
A
TJ = 125°C
TJ = 125°C
0.5
W
°C
°C
-40 to 150
-40 to 125
Operating junction temperature range
Note: xx = voltage/10, y = sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Absolute Maximum Ratings — Alternistor (3 Quadrants)
Symbol
Parameter
Value
Unit
Qxx08LHy
TC = 90°C
TC = 95°C
IT(RMS)
RMS on-state current (full sine wave)
8
A
Qxx08RHy / Qxx08NHy
Qxx08VHy / Qxx08DHy
Qxx08VHy /
Qxx08DHy
80
83
f = 50 Hz
f = 60 Hz
t = 20 ms
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
Qxx08VHy /
Qxx08DHy
85
t = 16.7 ms
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
100
30
Qxx08VHy /
Qxx08DHy
I2t
I2t Value for fusing
Critical rate of rise of on-state current
Peak gate trigger current
tp = 8.3 ms
A2s
A/μs
A
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
41
di/dt
IGTM
f = 120 Hz
70
4
TJ = 125°C
Qxx08VHy /
Qxx08DHy
tp=20μs
TJ = 125°C
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
4
Qxx08VHy /
Qxx08DHy
IGT = 10mA
IGT = 35mA
0.4
0.5
PG(AV)
Average gate power dissipation
W
TJ = 125°C
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
Storage temperature range
-40 to 150
-40 to 125
°C
°C
Tstg
TJ
Operating junction temperature range
Note: xx = voltage/10, y = sensitivity
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — SensitiveTriac (4 Quadrants)
Symbol
Test Conditions
VD = 12V RL = 60 Ω
Quadrant
Lxx08x6
Lxx08x8
Unit
I – II – III
5
10
10
20
IGT
MAX.
mA
IV
VGT
VGD
IH
VD = 12V RL = 60 Ω
VD = VDRM RL = 3.3 kΩ TJ = 110°C
IT = 100mA
ALL
ALL
MAX.
MIN.
MAX.
1.3
V
V
0.2
10
30
20
2
20
40
30
2
mA
400V
600V
dv/dt
VD = VDRM Gate Open TJ = 100°C
TYP.
V/μs
(dv/dt)c
tgt
(di/dt)c = 4.3 A/ms TJ = 110°C
TYP.
TYP.
V/μs
μs
IG = 100mA PW = 15µs IT = 11.3 A(pk)
3.0
3.2
Note: xx = voltage/10, x = package, y = sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — StandardTriac
Symbol
Test Conditions
VD = 12V RL = 60 Ω
Quadrant
Qxx08x4
Qxx08x5
Unit
I – II – III
MAX.
TYP.
25
50
50
75
IGT
mA
IV
VGT
VGD
IH
VD = 12V RL = 60 Ω
VD = VDRM RL = 3.3 kΩ TJ = 125°C
IT = 200mA
I – II – III
ALL
MAX.
MIN.
MAX.
1.3
V
V
0.2
50
50
mA
400V
600V
800V
1000V
150
125
100
80
dv/dt
VD = VDRM Gate Open TJ = 125°C
MIN.
V/μs
(dv/dt)c
tgt
(di/dt)c = 4.3 A/ms TJ = 125°C
TYP.
TYP.
4
4
V/μs
μs
IG = 100mA PW = 15µs IT = 11.3 A(pk)
3.0
3.0
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — AlternistorTriac (3 Quadrants)
Symbol
IGT
Test Conditions
VD = 12V RL = 60 Ω
Quadrant
Qxx08xH3
Qxx08xH4
Unit
I – II – III
MAX.
10
35
mA
VGT
VGD
IH
VD = 12V RL = 60 Ω
VD = VDRM RL = 3.3 kΩ TJ = 125°C
IT = 100mA
I – II – III
I – II – III
MAX.
MIN.
MAX.
1.3
V
V
0.2
15
75
50
35
mA
400V
600V
800V
1000V
400V
600V
800V
1000V
400
300
200
100
450
350
250
150
25
Qxx08LHy /
Qxx08RHy /
Qxx08NHy
dv/dt
VD = VDRM Gate Open TJ = 125°C
MIN.
V/μs
75
50
Qxx08VHy /
Qxx08DHy
(dv/dt)c
tgt
(di/dt)c = 4.3 A/ms TJ = 125°C
MIN.
TYP.
20
V/μs
μs
IG = 100mA PW = 15µs IT = 11.3 A(pk)
4.0
4.0
Note : xx = voltage/10, x = package, y = sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Static Characteristics
Symbol
VTM
Test Conditions
ITM = 11.3A tp = 380 µs
Value
1.60
10
0.5
20
2
Unit
V
MAX.
MAX.
TJ = 25°C
TJ = 110°C
TJ = 25°C
TJ = 125°C
TJ = 100°C
400 - 600V
400 - 600V
400 - 1000V
400 - 800V
1000V
μA
mA
μA
Lxx08xy
Qxx08xy
mA
μA
IDRM
IRRM
VDRM = VRRM
3
400 - 800V
1000V
10
20
2
TJ = 25°C
Qxx08xHy
TJ = 125°C
TJ = 100°C
400 - 800V
1000V
mA
3
Thermal Resistances
Symbol
Parameter
Value
Unit
L/Qxx08Ryy /
L/Qxx08Nyy
1.5
Junction to case (AC)
Junction to ambient
°C/W
°C/W
Rθ(J-C)
L/Qxx08Lyy
2.8
2.1
45
50
64
L/Qxx08Vyy
L/Qxx08Ryy
L/Qxx08Lyy
L/Qxx08Vyy
Rθ(J-A)
Note: xx = voltage/10, x = package, y = sensitivity, yy = type & sensitivity
Figure 2: Normalized DC GateTrigger Current for
All Quadrants vs. JunctionTemperature
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
MT2 POSITIVE
(Positive Half Cycle)
MT2
MT2
+
(-)
I
(+)
I
GT
GT
GATE
GATE
MT1
MT1
REF
REF
QII QI
I
-
+I
GT
GT
QIII QIV
MT2
MT2
(-)
I
(+)
I
GATE
GT
GT
GATE
-65
-40
-15
10
35
60
85
110
125
MT1
REF
MT1
REF
-
Junction Temperature (TJ)- ºC
MT2 NEGATIVE
(Negative Half Cycle)
Note: Alternistors will not operate in QIV
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 3: Normalized DC Holding Current
vs. JunctionTemperature
Figure 4: Normalized DC GateTriggerVoltage for
All Quadrants vs. JunctionTemperature
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
2.0
1.5
1.0
0.5
0.0
-65
-40
-15
10
35
60
85
110
125
-65
-40
-15
10
35
60
85
110
125
JunctionTemperature (T )- ºC
JunctionTemperature (T )- ºC
J
J
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable CaseTemperature
vs. On-State Current (SensitiveTriac)
110
18
16
14
12
10
8
105
Lxx08Vy
100
Lxx08Dy
Lxx08Ry
95
90
Lxx08Ly
85
80
75
70
65
60
6
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
4
CASETEMPERATURE: Measured as shown on
Dimensional Drawings
2
0
0
2
4
6
8
10
0
1
2
3
4
5
6
7
8
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable CaseTemperature
Figure 8: On-State Current vs. On-StateVoltage
(Typical)
vs. On-State Current (Standard / AlternistorTriac)
20
130
120
110
100
90
TC = 25°C
Qxx08Ryy
Qxx08Nyy
Qxx08Vyy
Qxx08Dyy
16
12
8
Qxx08Lyy
80
4
70
0
60
0.6
0.8
1.0
1.2
1.4
1.6
0
1
2
3
4
5
6
7
8
Postitive or Negative Instantaneous
On-StateVoltage (vT) -Volts
RMS On-State Current (IT(RMS)) - Amps
Note: xx = voltage/10, x = package, yy = type & sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Figure 9: Maximum Allowable AmbientTemperature vs. On-State Current
120
CURRENTWAVEFORM: Sinusoidal
LOAD: Resistive or Inductive CONDUCTION
ANGLE: 360
FREE AIR RATING - NO HEATSINK
100
80
L/Qxx08Lyy
L/Qxx08Ryy
60
L/Qxx08Vyy
40
20
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
RMS On-State Current (IT(RMS)) - Amps
Figure 10: Surge Peak On-State Current vs. Number of Cycles
100
L/Qxx08Ryy
L/Qxx08Lyy
L/Qxx08Nyy
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
L/Qxx08Vyy
L/Qxx08Dyy
Notes:
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
10
1
1
10
100
1000
Surge Current Duration- Full Cycles
Note: xx = voltage/10, x = package, y = sensitivity, yy = type & sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Soldering Parameters
Reflow Condition
Pb – Free assembly
tP
TP
-Temperature Min (Ts(min)
)
150°C
Ramp-up
TL
TS(max)
Pre Heat -Temperature Max (Ts(max)
)
200°C
tL
-Time (min to max) (ts)
60 – 180 secs
Ramp-down
Preheat
Average ramp up rate (LiquidusTemp)
(TL) to peak
5°C/second max
TS(min)
tS
TS(max) toTL - Ramp-up Rate
5°C/second max
217°C
-Temperature (TL) (Liquidus)
Reflow
25
time to peak temperature
-Temperature (tL)
60 – 150 seconds
260+0/-5 °C
Time
PeakTemperature (TP)
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
8 minutes Max.
280°C
Time 25°C to peakTemperature (TP)
Do not exceed
Physical Specifications
Environmental Specifications
Test
Specifications and Conditions
Terminal Finish
Body Material
100% MatteTin-plated
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
AC Blocking (VDRM
)
UL Recognized compound meeting
flammability rating V-0
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
Temperature Cycling
Terminal Material
Copper Alloy
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
Temperature/
Humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
HighTemp Storage
Low-Temp Storage
Design Considerations
1008 hours; -40°C
Careful selection of the correct component for the
application’s operating parameters and environment will
go a long way toward extending the operating life of the
Thyristor. Good design practice should limit the maximum
continuous current through the main terminals to 75% of
the component rating. Other ways to ensure long life for
a power discrete semiconductor are proper heat sinking
and selection of voltage ratings for worst case conditions.
Overheating, overvoltage (including dv/dt), and surge
currents are the main killers of semiconductors. Correct
mounting, soldering, and forming of the leads also help
protect against component damage.
Resistance to
Solder Heat
MIL-STD-750 Method 2031
Solderability
Lead Bend
ANSI/J-STD-002, category 3, Test A
MIL-STD-750, M-2036 Cond E
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-220AB (R-Package) — Non-Isolated MountingTab Common with Center Lead
T
C MEASURING POINT
AREA (REF.) 0.17 IN2
Inches
Millimeters
Min
Dimension
O
8.13
.320
A
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
E
P
MT2
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
B
C
13.36
.526
D
7. 01
.276
NOTCH IN
GATE LEAD
TO ID.
NON-ISOLATED
TAB
F
F
G
H
J
R
G
L
H
K
K
N
L
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
J
M
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
MT1 MT2
GATE
R
0.97
1.22
Dimensions —TO-220AB (L-Package) — Isolated MountingTab
T
C MEASURING POINT
AREA (REF.) 0.17 IN2
Inches
Millimeters
Dimension
O
8.13
.320
A
E
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Min
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
P
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
B
C
13.36
.526
D
7. 01
.276
F
F
G
H
J
R
G
L
H
K
K
N
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
L
J
MT1 MT2
M
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
GATE
R
0.97
1.22
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-263AB (N-Package) — D2-PAK Surface Mount
TC MEASURING POINT
C
AREA: 0.11 IN2
Inches
Millimeters
B
V
Dimension
E
MT2
Min
Max
0.370
0.420
0.188
0.035
0.060
0.075
0.105
0.102
0.024
0.110
0.625
0.045
0.010
0.070
Min
Max
9.40
10.67
4.78
0.89
1.52
A
B
C
D
E
0.360
0.380
0.178
0.025
0.045
0.060
0.095
0.092
0.018
0.090
0.590
0.035
0.002
0.040
9.14
9.65
4.52
0.64
1.14
8.41
.331
7. 01
.276
A
S
W
U
J
K
GATE
MT1
8.13
.320
G
F
1.52
2.41
2.34
0.46
2.29
14.99
0.89
0.05
1.02
1.91
H
D
F
G
H
J
2.67
2.59
0.61
2.79
15.88
1.14
11.68
.460
2.16
.085
K
7. 01
.276
7. 01
.276
S
16.89
.665
V
8.89
.350
1.40
.055
U
W
0.25
1.78
3.81
.150
2.03
.080
6.60
.260
Dimensions —TO-251AA (V-Package) —V-PAKThrough Hole
TC MEASURING POINT
AREA: 0.040 IN2
Inches
Typ
Millimeters
Dimension
Min
Max
Min
0.94
5.97
8.89
5.21
6.48
0.69
2.21
2.16
4.47
0.46
0.90
0.46
1.06
0.86
0.86
1.86
Typ
1.01
6.15
9.18
5.29
6.66
0.80
2.28
2.34
4.57
0.51
0.95
0.52
1.20
1.00
1.00
2.00
Max
1.09
6.22
9.53
5.41
6.73
0.84
2.36
2.41
4.67
0.58
1.00
0.58
1.32
1.11
E
H
J
5.28
.208
MT2
A
D
A
B
C
D
E
F
0.037
0.235
0.350
0.205
0.255
0.027
0.087
0.085
0.176
0.018
0.035
0.018
0.042
0.034
0.034
0.074
0.040
0.242
0.361
0.208
0.262
0.031
0.090
0.092
0.180
0.020
0.037
0.020
0.047
0.039
0.039
0.079
0.043
0.245
0.375
0.213
0.265
0.033
0.093
0.095
0.184
0.023
0.039
0.023
0.052
0.044
0.044
0.084
5.34
.210
B
R
P
Q
S
G
H
I
K
C
J
K
L
MT1
L
F
MT2
GATE
G
P
Q
R
S
I
1.11
2.11
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Dimensions —TO-252AA (D-Package) — D-PAK Surface Mount
E
6.71
.264
MT2
A
5.28
.208
Inches
Typ
Millimeters
Typ
TC MEASURING POINT
D
Dimension
Min
0.037
0.235
0.106
0.205
0.255
0.027
0.087
0.085
0.176
0.018
0.035
0.018
0.000
0.021
0°
Max
0.043
0.245
0.113
0.213
0.265
0.033
0.093
0.095
0.184
0.023
0.039
0.023
0.004
0.027
5°
Min
0.94
5.97
2.69
5.21
6.48
0.69
2.21
2.16
4.47
0.46
0.90
0.46
0.00
0.53
0°
Max
1.09
6.22
2.87
5.41
6.73
0.84
2.36
2.41
4.67
0.58
1.00
0.58
0.10
0.69
5°
6.71
.264
5.34
.210
A
B
C
D
E
F
0.040
0.243
0.108
0.208
0.262
0.031
0.090
0.092
0.179
0.020
0.037
0.020
0.000
0.026
0°
1.01
B
6.16
2.74
1.60
.063
P
Q
C
5.29
6.65
0.80
2.28
2.33
4.55
0.51
0.95
0.51
0.00
0.67
0°
1.80
.071
GATE
F
AREA: 0.040 IN2
MT1
MT2
3
.118
4.60
.181
G
I
G
H
I
L
O
H
K
J
M
N
J
K
L
M
N
O
P
Q
0.042
0.034
0.047
0.039
0.052
0.044
1.06
0.86
1.20
1.32
1.11
1.00
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Product Selector
Voltage (xx)
400V 600V 800V 1000V
Gate Sensitivity Quadrants
Part Number
Type
Package
I – II – III
5 mA
IV
Lxx08L6
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10 mA
10 mA
10mA
10 mA
20 mA
20 mA
20mA
20 mA
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
SensitiveTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
Triac
TO-220L
TO-252 D-PAK
TO-220R
Lxx08D6
Lxx08R6
5 mA
5mA
Lxx08V6
5 mA
TO-251 V-PAK
TO-220L
Lxx08L8
10 mA
10 mA
10mA
10 mA
10mA
10 mA
10 mA
10 mA
25 mA
25 mA
25 mA
35 mA
35 mA
35 mA
35 mA
35 mA
50 mA
50 mA
50 mA
Lxx08D8
Lxx08R8
TO-252 D-PAK
TO-220R
Lxx08V8
TO-251 V-PAK
TO-263 D²-PAK
TO-220R
Qxx08NH3
Qxx08RH3
Qxx08VH3
Qxx08DH3
Qxx08L4
Qxx08R4
Qxx08N4
Qxx08LH4
Qxx08RH4
Qxx08VH4
Qxx08DH4
Qxx08NH4
Qxx08L5
Qxx08R5
Qxx08N5
TO-251 V-PAK
TO-252 D-PAK
TO-220L
Triac
TO-220R
Triac
TO-263 D²-PAK
TO-220L
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
Triac
TO-220R
TO-251 V-PAK
TO-252 D-PAK
TO-263 D²-PAK
TO-220L
Triac
TO-220R
Triac
TO-263 D²-PAK
Packing Options
Part Number
L/Qxx08L/RyyTP
Qxx08NyyTP
Marking
Weight
Packing Mode
Base Quantity
L/Qxx08L/Ryy
Qxx08Nyy
2.2 g
1.6 g
1.6 g
0.3 g
0.3 g
0.4 g
Tube Pack
Tube
500 (50 per tube)
500 (50 per tube)
500
Qxx08NyyRP
Qxx08Nyy
Embossed Carrier
Tube
L/Qxx08DyyTP
L/Qxx08DyyRP
L/Qxx08VyyTP
L/Qxx08Dyy
L/Qxx08Dyy
L/Qxx08Vyy
750 (75 per tube)
2500
Embossed Carrier
Tube
750 (75 per tube)
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
TO-252 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.157
(4.0)
0.059
Dia
(1.5)
Gate
MT1
0.63
0.524
(13.3)
*
(16.0)
0.315
(8.0)
*
Cover tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
0.64
(16.3)
Direction of Feed
TO-263 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.63
(16.0)
0.157
(4.0)
Gate
MT1
0.059
(1.5)
DIA
0.945
(24.0)
0.827
(21.0)
*
*
Cover tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
1.01
(25.7)
Direction of Feed
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
Thyristors
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
Part Numbering System
Q 60 08 L 5 56
Part Marking System
TO-251AA – (V Package)
TO-252AA – (D Package)
DEVICE TYPE
L : Sensitive Triac
LEAD FORM DIMENSIONS
xx : Lead Form Option
Q : Triac or Alternistor
L6008V5
L6008V5
VOLTAGE RATING
40 : 400V
60 : 600V
80: 800V
K0 : 1000V
SENSITIVITY & TYPE
Sensitive Triac:
6
:
5 mA (QI, II, III)
10 mA (QIV)
8
:
10 mA (QI, II, III)
20 mA (QIV)
YMLDD
YMLDD
®
®
Standard Triac:
Date Code Marking
Y:Year Code
M: Month Code
L: Location Code
DD: Calendar Code
CURRENT
08: 8A
4
5
:
:
25 mA (QI, II, III)
50 mA (QI, II, III)
Alternistor Triac:
H3
H4
:
:
10 mA (QI, II, III)
35 mA (QI, II, III)
TO-220 AB - (L and R Package)
TO-263 AB - (N Package)
PACKAGE TYPE
L : TO-220 Isolated
R : TO-220 Non-Isolated
N: TO-263 (D2PAK)
V : TO-251 (VPAK)
D : TO-252 (DPAK)
Q6008R5
YMXXX
®
Date Code Marking
Y:Year Code
M: Month Code
XXX: Lot Trace Code
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/29/18
相关型号: