Q8025LH5TP [LITTELFUSE]

TRIAC ALTERNISTOR 800V 25A TO220;
Q8025LH5TP
型号: Q8025LH5TP
厂家: LITTELFUSE    LITTELFUSE
描述:

TRIAC ALTERNISTOR 800V 25A TO220

LTE 三端双向交流开关
文件: 总11页 (文件大小:990K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
RoHS  
Qxx25xx & Qxx25xHx Series  
Description  
This 25 Amp bi-directional solid state switch series is  
designed for AC switching and phase control applications  
such as motor speed and temperature modulation controls,  
lighting controls, and static switching relays.  
Standard alternistor triac components operate with in-  
phase signals in Quadrants I or III and ONLY unipolar  
negative gate pulses for Quadrant II or III. The alternistor  
triac will not operate in Quadrant IV.  
Features & Benefits  
• RoHS compliant  
• Surge capability up  
to 250A at 60 Hz  
half cycle  
• Glass – passivated  
junctions  
Agency Approval  
• Voltage capability up  
to 1000 V  
Agency  
Agency File Number  
E71639*  
* - Only Package Types TO-220L, TO-218K and TO-218J  
Applications  
Excellent for AC switching and phase control applications  
such as heating, lighting, and motor speed controls.  
Typical applications are AC solid-state switches, industrial  
power tools, exercise equipment, white goods and  
commercial appliances.  
Main Features  
Symbol  
Value  
Unit  
Alternistor Triacs (no snubber required) are used in  
applications with high inductive loads requiring the highest  
commutation performance.  
IT(RMS)  
25  
A
V
DRM/VRRM  
IGT  
1000  
V
50 or 80  
mA  
Internally constructed isolated packages are offered for  
ease of heat sinking with highest isolation voltage.  
Schematic Symbol  
Additional Information  
MT2  
MT1  
ꢀꢁtꢁshꢂꢂt  
ꢀꢁsoꢂrꢃꢁs  
ꢀꢁꢂꢃꢄꢅs  
G
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Absolute Maximum Ratings – StandardTriac  
Symbol  
Parameter  
Test Conditions  
Tc = 65°C  
Value  
Unit  
Qxx25R5  
Qxx25N5  
Qxx25L5  
IT(RMS)  
RMS on-state current  
25  
A
TC = 95°C  
full cycle; f = 50Hz;  
TJ (initial) = 25°C  
167  
200  
Qxx25R5  
Qxx25N5  
Qxx25L5  
ITSM  
Peak non-repetitive surge current  
I2t Value for fusing  
A
full cycle; f = 60Hz;  
TJ (initial) = 25°C  
Qxx25R5  
Qxx25N5  
Qxx25L5  
I2t  
tp = 8.3ms  
166  
A2s  
di/dt  
IGTM  
Critical rate-of-rise of on-state current  
Peak gate current  
f = 60Hz;TJ =125°C  
100  
4
A/μs  
A
tp=20μs, TJ =125°C  
TJ = 125°C  
PG(AV)  
Tstg  
Average gate power dissipation  
0.5  
W
Storage temperature range  
-40 to 125  
°C  
Qxx25R5  
Qxx25N5  
Qxx25L5  
TJ  
Operating junction temperature range  
-40 to 125  
°C  
Absolute Maximum Ratings – AlternistorTriac  
Symbol  
Parameter  
Test Conditions  
Value  
Unit  
Qxx25LH5  
Qxx25L6  
TC = 65°C  
Qxx25K6  
Qxx25J6  
TC = 85°C  
TC = 95°C  
IT(RMS)  
RMS on-state current  
25  
A
Qxx25RH5  
Qxx25NH5  
Qxx25R6  
Qxx25NH6  
full cycle; f = 50Hz;  
TJ (initial) = 25°C  
208  
250  
ITSM  
Peak non-repetitive surge current  
A
full cycle; f = 60Hz;  
TJ (initial) = 25°C  
I2t  
I2t Value for fusing  
Critical rate-of-rise of on-state current  
Peak gate current  
tp = 8.3ms  
f = 60Hz;TJ =125°C  
tp=20μs, TJ =125°C  
TJ = 125°C  
260  
100  
A2s  
A/μs  
A
di/dt  
IGTM  
4
PG(AV)  
Average gate power dissipation  
0.5  
W
Tstg  
TJ  
Storage temperature range  
-40 to 125  
-40 to 125  
°C  
Operating junction temperature range  
°C  
Note: xx = voltage/10  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — StandardTriac  
Value  
Qxx25R5  
Qxx25N5  
Qxx25L5  
Symbol  
Test Conditions  
Quadrant  
Unit  
I – II – III  
IV  
MAX.  
TYP.  
50  
120  
1.3  
IGT  
VD = 12V; RL = 60 Ω  
VD = 12V; RL = 60 Ω  
mA  
V
I – II – III  
IV  
MAX.  
TYP.  
VGT  
2.5  
VGD  
IH  
VD = VDRM; RL = 3.3 kΩ ; TJ = 125°C  
IT = 400mA (initial)  
ALL  
MIN.  
0.2  
V
MAX.  
100  
mA  
400V  
600V  
800V  
275  
225  
200  
VD = VDRM; Gate Open; TJ = 125°C  
dv/dt  
MIN.  
V/μs  
VD = VDRM; Gate Open; TJ = 100°C  
(di/dt)c = 13.3 A/ms; TJ = 125°C  
IG = 2 x IGT; PW = 15µs; IT = 35.4 A  
1000V  
200  
5
(dv/dt)c  
tgt  
MIN.  
TYP.  
V/μs  
μs  
4
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — AlternistorTriac  
Value  
Qxx25R6  
Qxx25L6  
Qxx25NH6  
Qxx25K6  
Qxx25J6  
Qxx25RH5  
Qxx25LH5  
Qxx25NH5  
Symbol  
Test Conditions  
Quadrant  
Unit  
IGT  
VGT  
VGD  
IH  
VD = 12V; RL = 60 Ω  
VD = 12V; RL = 60 Ω  
I – II – III  
I – II – III  
I – II – III  
MAX.  
MAX.  
MIN.  
MAX.  
50  
80  
mA  
V
1.3  
VD = VDRM; RL = 3.3 kΩ ; TJ = 125°C  
IT = 400mA (initial)  
0.2  
V
50  
575  
500  
400  
-
100  
600  
600  
475  
400  
30  
mA  
400V  
600V  
800V  
1000V  
VD = VDRM; Gate Open; TJ = 125°C  
dv/dt  
MIN.  
V/μs  
VD = VDRM; Gate Open; TJ = 100°C  
(di/dt)c = 13.3 A/ms; TJ = 125°C  
IG = 2 x IGT; PW = 15µs; IT = 35.4 A  
(dv/dt)c  
tgt  
MIN.  
TYP.  
20  
3
V/μs  
μs  
5
Static Characteristics  
Value  
Qxx25R5  
Qxx25N5  
Qxx25xH5  
Qxx25x6  
Qxx25NH6  
Qxx25L5  
Symbol  
Test Conditions  
Unit  
VTM  
IT = 35.4A; tp = 380 μs  
MAX.  
MAX.  
1.8  
10  
V
400 - 800V  
1000V  
TJ = 25°C  
20  
I
DRM / IRRM  
VDRM / VRRM  
400 - 800V  
1000V  
500  
1000  
2000  
μA  
TJ = 100°C  
TJ = 125°C  
400 - 800V  
Note: xx = voltage/10, x = package  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Thermal Resistances  
Symbol  
Parameter  
Value  
Unit  
Qxx25R5 / Qxx25N5  
Qxx25R6 / Qxx25NH6  
Qxx25RH5 / Qxx25NH5  
0.89  
RƟ(J-C)  
Junction to case (AC)  
Junction to ambient  
°C/W  
Qxx25L6 / Qxx25LH5 /Qxx25L5  
Qxx25K6 / Qxx25J6  
2.0  
1.32  
45  
Qxx25Ry  
RƟ(J-A)  
°C/W  
Qxx25L6 / Qxx25LH5 /Qxx25L5  
50  
Note: xx = voltage/10, y = sensitivity  
Figure 1: Normalized DC GateTrigger Current  
vs. JunctionTemperature  
Figure 2: Normalized DC GateTriggerVoltage  
vs. JunctionTemperature  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
2.0  
1.5  
1.0  
0.5  
0.0  
-40  
-15  
10  
35  
60  
85  
110  
125  
125  
-40  
-15  
10  
35  
60  
85  
110  
Junction Temperature (TJ) -- (ºC)  
Junction Temperature (TJ) -- (°C)  
Figure 3: Normalized DC Holding Current  
vs. JunctionTemperature  
Figure 4: On-State Current vs. On-State  
Voltage (Typical)  
2.0  
1.5  
1.0  
0.5  
0.0  
90  
TJ = 25°C  
80  
70  
60  
50  
40  
30  
20  
10  
0
Qxx25P5/Qxx25R6  
Qxx25L6/Qxx25NH6  
Qxx25K6/Qxx25J6  
Qxx25RH5/Qxx25LH5  
Qxx25NH5  
Qxx25R5  
Qxx25N5  
Qxx25L5  
0.7  
0.8  
0.9  
1.0  
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
1.7  
-40  
-15  
10  
35  
60  
85  
110  
125  
Instantaneous On-state Voltage (vT) – Volts  
Junction Temperature (TJ) -- (ºC)  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Figure 5: Power Dissipation (Typical) vs. RMS  
Figure 6: Maximum Allowable CaseTemperature  
vs. RMS On-State Current  
On-State Current  
130  
35  
30  
25  
20  
15  
10  
5
Qxx25R6  
Qxx25NH6  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360°  
120  
Qxx25RH5  
Qxx25NH5  
Qxx25R5  
Qxx25N5  
Qxx25R5  
Qxx25N5  
Qxx25L5  
Qxx25K6  
Qxx25J6  
110  
100  
90  
Qxx25L6  
Qxx25LH5  
Qxx25L5  
80  
Qxx25R6  
Qxx25L6/Qxx25NH6  
Qxx25K6/Qxx25J6  
Qxx25RH5/Qxx25LH5  
Qxx25NH5  
70  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360°  
60  
0
50  
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
30  
RMS On-State Current [IT(RMS)] -- Amps  
RMS On-State Current [IT(RMS)] - Amps  
Figure 7: Maximum Allowable AmbientTemperature vs. RMS On-State Current (TO-220 packages only)  
120  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360°  
100  
FREE AIR RATING  
80  
60  
40  
20  
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
RMS On-State Current [IT(RMS)] -- Amps  
Figure 8: Surge Peak On-State Current vs. Number of Cycles  
1000  
Qxx25P5/Qxx25R6  
Qxx25L6/Qxx25NH6  
Qxx25K6/Qxx25J6  
Qxx25RH5/Qxx25LH5  
Qxx25NH5  
SUPPLY FREQUENCY: 60 Hz Sinusoidal  
LOAD: Resistive  
RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified  
Case Temperature  
100  
Notes:  
1. Gate control may be lost during and immediately following surge current interval.  
2. Overload may not be repeated until junction temperature has returned to steady-state  
Qxx25R5  
rated value.  
Qxx25N5  
Qxx25L5  
10  
1
10  
100  
1000  
Surge Current Duration -- Full Cycles  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Soldering Parameters  
Reflow Condition  
Pb – Free assembly  
tP  
-Temperature Min (Ts(min)  
-Temperature Max (Ts(max)  
-Time (min to max) (ts)  
)
150°C  
TP  
Pre Heat  
)
200°C  
Ramp-up  
60 – 180 secs  
TL  
TS(max)  
tL  
Average ramp up rate (LiquidusTemp)  
(TL) to peak  
5°C/second max  
5°C/second max  
Ramp-down  
Preheat  
TS(max) toTL - Ramp-up Rate  
TS(min)  
-Temperature (TL) (Liquidus) 217°C  
Reflow  
tS  
-Temperature (tL)  
60 – 150 seconds  
260+0/-5 °C  
PeakTemperature (TP)  
25  
time to peak temperature  
Time  
Time within 5°C of actual peak  
Temperature (tp)  
20 – 40 seconds  
Ramp-down Rate  
5°C/second max  
8 minutes Max.  
280°C  
Time 25°C to peakTemperature (TP)  
Do not exceed  
Physical Specifications  
Environmental Specifications  
Terminal Finish  
Body Material  
Lead Material  
100% MatteTin-plated  
Test  
Specifications and Conditions  
UL Recognized compound meeting flammability  
rating V-0  
HighTemperature  
Voltage Blocking  
MIL-STD-750: Method 1040, Condition A  
Rated VRRM, 125°C, 1008 hours  
Copper Alloy  
MIL-STD-750: Method 1051  
-40°C to 125°C, 15-minute dwell,  
100 cycles  
Temperature Cycling  
BiasedTemp &  
Humidity  
EIA/JEDEC: JESD22-A101  
320VDC, 85°C, 85%RH, 1008 hours  
Design Considerations  
Careful selection of the correct component for the  
application’s operating parameters and environment will  
go a long way toward extending the operating life of the  
Thyristor. Good design practice should limit the maximum  
continuous current through the main terminals to 75%  
of the device rating. Other ways to ensure long life for  
a power discrete semiconductor are proper heat sinking  
and selection of voltage ratings for worst case conditions.  
Overheating, overvoltage (including dv/dt), and surge  
currents are the main killers of semiconductors. Correct  
mounting, soldering, and forming of the leads also help  
protect against component damage.  
MIL-STD-750: Method 1031  
150°C, 1008 hours  
HighTemp. Storage  
Low-Temp Storage  
-40°C, 1008 hours  
Resistance to  
Solder Heat  
MIL-STD-750: Method 2031  
260°C, 10 seconds  
Solderability  
Lead Bend  
ANSI/J-STD-002, Category 3, Test A  
MIL-STD-750: Method 2036, Condition E  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-220AB (R Package) — Non-isolated MountingTab  
T
C MEASURING POINT  
AREA (REF.) 0.17 IN2  
Inches  
Millimeters  
Min  
Dimension  
O
8.13  
.320  
Min  
Max  
0.420  
0.115  
0.250  
0.620  
0.147  
0.130  
0.575  
0.035  
0.205  
0.105  
0.075  
0.095  
0.024  
0.188  
0.060  
0.048  
Max  
10.67  
2.92  
6.35  
15.75  
3.73  
3.30  
14.61  
0.89  
5.21  
2.67  
1.91  
A
Ø
E
P
MT2  
A
B
C
D
E
0.380  
0.105  
0.230  
0.590  
0.142  
0.110  
0.540  
0.025  
0.195  
0.095  
0.060  
0.085  
0.018  
0.178  
0.045  
0.038  
9.65  
2.67  
5.84  
14.99  
3.61  
2.79  
13.72  
0.64  
4.95  
2.41  
1.52  
B
C
13.36  
.526  
D
7.01  
.276  
F
G
H
J
NOTCH IN  
GATE LEAD  
TO ID.  
NON-ISOLATED  
TAB  
F
R
G
L
K
L
H
M
N
O
P
2.16  
0.46  
4.52  
1.14  
2.41  
0.61  
4.78  
1.52  
K
N
J
M
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs. (0.904 Nm).  
MT1 MT2  
GATE  
R
0.97  
1.22  
Dimensions TO-220AB (L Package) — Isolated MountingTab  
T
C MEASURING POINT  
AREA (REF.) 0.17 IN2  
Millimeters  
Inches  
Dimension  
O
Min  
9.65  
2.66  
5.85  
14.98  
3.61  
2.80  
13.71  
0.63  
4.95  
2.41  
1.52  
Max  
10.67  
2.92  
6.35  
15.75  
3.73  
3.30  
14.60  
0.89  
5.21  
2.67  
1.91  
Min  
Max  
8.13  
.320  
A
Ø
E
P
A
B
C
D
E
0.380  
0.420  
B
0.105  
0.230  
0.590  
0.142  
0.110  
0.540  
0.025  
0.195  
0.095  
0.060  
0.085  
0.018  
0.178  
0.045  
0.038  
0.115  
0.250  
0.620  
0.147  
0.130  
0.575  
0.035  
0.205  
0.105  
0.075  
0.095  
0.024  
0.188  
0.060  
0.048  
C
13.36  
.526  
D
7.01  
.276  
F
F
G
H
J
R
G
L
H
K
L
K
N
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs. (0.904 Nm).  
J
MT1 MT2  
M
GATE  
M
N
O
P
1.78  
2.16  
0.61  
4.78  
1.53  
0.45  
4.52  
1.14  
R
0.97  
1.22  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-263 (N Package) — D2Pak Surface Mount  
TC MEASURING POINT  
AREA: 0.11 IN2  
Inches  
Millimeters  
C
B
V
Dimension  
E
MT2  
Min  
Max  
Min  
Max  
A
B
C
D
E
0.360  
0.380  
0.178  
0.025  
0.045  
0.060  
0.095  
0.092  
0.018  
0.090  
0.590  
0.035  
0.002  
0.040  
0.370  
0.420  
0.188  
0.035  
0.060  
0.075  
0.105  
0.102  
0.024  
0.110  
0.625  
0.045  
0.010  
0.070  
9.14  
9.65  
4.52  
0.64  
1.14  
9.40  
10.67  
4.78  
0.89  
1.52  
8.41  
.331  
7. 01  
.276  
A
S
W
U
J
K
F
1.52  
2.41  
2.34  
0.46  
2.29  
14.99  
0.89  
0.05  
1.02  
1.91  
GATE  
MT1  
G
H
J
2.67  
2.59  
0.61  
2.79  
15.88  
1.14  
8.13  
.320  
G
H
D
F
11.68  
.460  
2.16  
.085  
K
S
V
U
W
0.25  
1.78  
7. 01  
.276  
7. 01  
.276  
16.89  
.665  
8.89  
.350  
1.40  
.055  
3.81  
.150  
2.03  
.080  
6.60  
.260  
Dimensions TO-218AC (K Package) — Isolated MountingTab  
TC Measurement Point  
Inches  
Millimeters  
U (diameter)  
C
Dimension  
B
Min  
Max  
Min  
Max  
D
A
B
C
D
E
0.810  
0.610  
0.178  
0.055  
0.487  
0.635  
0.022  
0.075  
0.575  
0.211  
0.422  
0.058  
0.045  
0.095  
0.008  
0.008  
0.164  
0.085  
0.835  
0.630  
0.188  
0.070  
0.497  
0.655  
0.029  
0.095  
0.625  
0.219  
0.437  
0.068  
0.055  
0.115  
0.016  
0.016  
0.165  
0.095  
20.57  
15.49  
4.52  
1.40  
21.21  
16.00  
4.78  
1.78  
A
F
E
W
12.37  
16.13  
0.56  
1.91  
12.62  
16.64  
0.74  
Gate  
F
J
P
G
H
J
MT1  
MT2  
2.41  
15.88  
5.56  
11.10  
1.73  
H
M
Q
14.61  
5.36  
10.72  
1.47  
G
K
L
R
N
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs. (0.904 Nm).  
M
N
P
K
1.14  
1.40  
L
2.41  
0.20  
0.20  
4.10  
2.92  
0.41  
0.41  
4.20  
2.42  
Q
R
U
W
2.17  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Dimensions TO-218X (J Package) — Isolated MountingTab  
C
Inches  
Millimeters  
Min  
Dimension  
D
B
Min  
Max  
0.835  
0.630  
0.188  
0.070  
0.497  
0.655  
0.029  
0.095  
0.625  
0.264  
0.228  
0.088  
0.177  
0.042  
0.121  
0.096  
0.166  
0.165  
0.618  
0.005  
0.012  
0.032  
0.095  
Max  
21.21  
16.00  
4.78  
1.78  
U (diameter)  
A
B
C
D
E
0.810  
0.610  
0.178  
0.055  
0.487  
0.635  
0.022  
0.075  
0.575  
0.256  
0.220  
0.080  
0.169  
0.034  
0.113  
0.086  
0.156  
0.164  
0.603  
0.000  
0.003  
0.028  
0.085  
20.57  
15.49  
4.52  
1.40  
T
c
Measurement  
Point  
A
F
Z
12.37  
16.13  
0.56  
1.91  
12.62  
16.64  
0.74  
E
F
G
H
J
MT1  
2.41  
15.88  
6.71  
5.79  
2.24  
4.49  
1.07  
X
W
14.61  
6.50  
5.58  
2.03  
4.29  
0.86  
2.87  
2.18  
3.96  
0.410  
15.31  
0.00  
0.07  
0.71  
2.17  
J
K
L
Gate  
R
N
T
S
P
MT2  
M
N
P
G
H
M
Y
K
L
R
S
T
3.07  
2.44  
4.22  
0.420  
15.70  
0.13  
Note: Maximum torque to  
be applied to mounting tab  
is 8 in-lbs . (0.904 Nm).  
V
U
V
W
X
Y
Z
0.30  
0.81  
2.42  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
Product Selector  
Voltage  
Gate Sensitivity Quadrants  
Part Number  
Package  
400V  
600V  
800V  
1000V  
I - II - III  
50 mA  
50 mA  
50 mA  
50 mA  
50 mA  
50 mA  
80 mA  
80 mA  
80 mA  
80 mA  
80 mA  
IV  
Qxx25R5  
Qxx25N5  
Qxx25L5  
Qxx25RH51  
Qxx25LH5  
Qxx25NH5  
Qxx25R6  
Qxx25L6  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
-
120 mA (TYP)  
TO-220R  
TO-263 D2-Pak  
TO-220L  
120 mA (TYP)  
120 mA (YTP)  
-
-
-
-
-
-
-
-
TO-220R  
-
TO-220L  
TO-263 D2-Pak  
-
X
X
X
-
TO-220R  
TO-220L  
TO-263 D2-Pak  
Qxx25NH6  
Qxx25J6  
TO-218X  
Qxx25K6  
X
TO-218AC  
Packing Options  
Part Number  
Marking  
Weight  
Packing Mode  
Base Quantity  
Qxx25R5TP  
Qxx25N5TP  
Qxx25N5RP  
Qxx25RH5TP  
Qxx25LH5TP  
Qxx25NH5TP  
Qxx25NH5RP  
Qxx25R6TP  
Qxx25L6TP  
Qxx25NH6TP  
Qxx25NH6RP  
Qxx25J6TP  
Qxx25R5  
Qxx25N5  
Qxx25N5  
Qxx25RH5  
Qxx25LH5  
Qxx25NH5  
Qxx25NH5  
Qxx25R6  
Qxx25L6  
2.20g  
1.60g  
1.60g  
2.20g  
2.20g  
1.60g  
1.60g  
2.20g  
2.20g  
1.60g  
1.60g  
5.23g  
4.40g  
2.20g  
Tube  
1000 (50 per tube)  
1000 (50 per tube)  
500  
Tube  
Embossed Carrier  
Tube  
1000 (50 per tube)  
1000 (50 per tube)  
1000 (50 per tube)  
500  
Tube  
Tube  
Embossed Carrier  
Tube  
1000 (50 per tube)  
1000 (50 per tube)  
1000 (50 per tube)  
500  
Tube  
Qxx25NH6  
Qxx25NH6  
Qxx25J6  
Tube  
Embossed Carrier  
Tube  
250 (25 per tube)  
250 (25 per tube)  
1000 (50 per tube)  
Qxx25K6TP  
Qxx25L5TP  
Qxx25K6  
Qxx25L5  
Tube  
Tube  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  
Thyristors  
25 Amp Standard & Alternistor (High Commutation) Triacs  
TO-263 Embossed Carrier Reel Pack (RP) Specifications  
Meets all EIA-481-2 Standards  
0.63  
(16.0)  
0.157  
(4.0)  
Gate  
0.059  
(1.5)  
DIA  
MT1 / Cathode  
0.945  
(24.0)  
0.827  
(21.0)  
*
*
Cover tape  
MT2 / Anode  
12.99  
(330.0)  
0.512 (13.0) Arbor  
Hole Dia.  
Dimensions  
are in inches  
(and millimeters).  
1.01  
(25.7)  
Direction of Feed  
Part Numbering System  
ꢀꢁ 2ꢂ  
Part Marking System  
TO-22ꢇ Aꢉ - (L anꢊ R Pacꢂaꢃe)  
TO-2ꢆꢋ Aꢉ - (N Pacꢂaꢃe)  
TO-21ꢀAC - (ꢁ Pacꢂaꢃe)  
TO-21ꢀꢄ - (ꢅ Pacꢂaꢃe)  
Q
N
ꢃꢀ  
SENSITIꢄITY  
Standard Triac  
5: 50mA  
Alternistor  
H5: 50mA  
6: 80mA  
COMPONENT TYPE  
Q: Triac or Alternistor  
Qꢆꢇ2ꢈRꢈ  
YMꢄꢄꢄ  
Qꢆꢇ2ꢈꢁꢆ  
ꢄOLTAꢅE RATINꢅ  
40: 400V  
60: 600V  
80: 800V  
K0: 1000V  
®
H6: 80mA  
YMLXX  
®
PACꢆAꢅE TYPE  
L
: TO-220AB Isolated  
Date Code Marking  
Y:Year Code  
M: Month Code  
XXX: Lot Trace Code  
R
N
K
J
: TO-220AB Non-Isolated  
: TO-263 (D2 -Pak)  
CURRENT RATINꢅ  
25: 25A  
: TO-218AC Isolated  
: TO-218X Isolated  
Date Code Marking  
Y:Year Code  
M: Month Code  
L: Location Code  
XX: Lot Serial Code  
Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are  
not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at http://www.littelfuse.com/disclaimer-electronics.  
©2019 Littelfuse, Inc  
Specifications are subject to change without notice.  
Revised: BO.12/10/20  

相关型号:

Q8025N5

Triacs (0.8 A to 35 A)
LITTELFUSE

Q8025N5RP

暂无描述
LITTELFUSE

Q8025N5TP

TRIAC, 800V V(DRM), 25A I(T)RMS, TO-263AB, ROHS COMPLIANT, TO-263, D2PAK-3
LITTELFUSE

Q8025NH5RP

ALTERNISTOR TRIAC 800V 25A 50-50
LITTELFUSE

Q8025NH5TP

ALTERNISTOR TRIAC 800V 25A 50-50
LITTELFUSE

Q8025NH6

Alternistor Triacs
TECCOR

Q8025NH6

Alternistor Triacs (6 A to 40 A)
LITTELFUSE

Q8025NH6RP

Alternistor TRIAC, 800V V(DRM), 25A I(T)RMS, TO-263AB, ROHS COMPLIANT, TO-263, D2PAK-3
LITTELFUSE

Q8025NH6TP

TRIAC ALTERNISTOR 800V 25A TO263
LITTELFUSE

Q8025P

Alternistor Triacs
TECCOR

Q8025P

Alternistor TRIAC, 800V V(DRM), 25A I(T)RMS, ISOLATED TO-3, FASTPAK-3
LITTELFUSE

Q8025P5

Triacs (0.8 A to 35 A)
LITTELFUSE