QK010N5TP56 [LITTELFUSE]
TRIAC, 1000V V(DRM), 10A I(T)RMS, TO-263AB, ROHS COMPLIANT, PLASTIC, D2PAK-3/2;型号: | QK010N5TP56 |
厂家: | LITTELFUSE |
描述: | TRIAC, 1000V V(DRM), 10A I(T)RMS, TO-263AB, ROHS COMPLIANT, PLASTIC, D2PAK-3/2 三端双向交流开关 |
文件: | 总9页 (文件大小:670K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
RoHS
Qxx10xx & Qxx10xHx Series
Description
10 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Features & Benefits
• RoHS Compliant
• Solid-state switching
eliminates arcing or
contact bounce that
create voltage transients
• Glass – passivated
junctions
Agency Approval
• Voltage capability up to
1000 V
• No contacts to wear
out from reaction of
switching events
Agency
Agency File Number
• Surge capability up to
120 A
L Package: E71639
• Restricted (or limited) RFI
generation, depending on
activation point sine wave
• Electrically isolated
package “L - Package”
and UL Recognized for
2500Vrms
Main Features
Symbol
IT(RMS)
Value
Unit
A
10
Applications
VDRM/VRRM
IGT (Q1)
400 to 1000
25 to 50
V
Alternistor type devices are used in applications requiring
high commutation performance such as controlling
inductive loads. Isolated packages are offered with internal
construction, having the case or mounting tab electrically
isolated from the semiconductor chip.
mA
Schematic Symbol
Additional Information
MT2
MT1
G
ꢀatasheet
ꢀesoꢁrces
ꢀaꢁꢂꢃes
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Absolute Maximum Ratings — StandardTriac
Symbol
IT(RMS)
Parameter
RMS on-state current (full sine wave)
Value
Unit
Qxx10Ry/
Qxx10Ny
TC = 95°C
10
A
Qxx10Ly
f = 50 Hz
f = 60 Hz
TC = 90°C
t = 20 ms
t = 16.7 ms
100
120
60
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
I2t
I2t Value for fusing
tp = 8.3 ms
A2s
Critical rate of rise of on-state current
IG = 200mA with ≤ 0.1μs rise time
di/dt
f = 120 Hz
70
A/μs
TJ = 125°C
tp ≤ 10 μs
IGT ≤ IGTM
IGTM
Peak gate trigger current
1.8
A
TJ = 125°C
TJ = 125°C
PG(AV)
Tstg
TJ
Average gate power dissipation
Storage temperature range
0.5
W
°C
°C
-40 to 150
-40 to 125
Operating junction temperature range
Absolute Maximum Ratings — AlternistorTriac (3 Quadrants)
Symbol Parameter
IT(RMS) RMS on-state current (full sine wave)
Value
Unit
Qxx10LHy
TC = 90°C
TC = 95°C
10
A
Qxx10RHy/
Qxx10NHy
f = 50 Hz
f = 60 Hz
t = 20 ms
110
120
60
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
ITSM
A
t = 16.7 ms
I2t
I2t Value for fusing
tp = 8.3 ms
A2s
di/dt
Critical rate of rise of on-state current
f = 120 Hz
70
A/μs
TJ = 125°C
TJ = 125°C
TJ = 125°C
tp ≤ 10 μs
IGT ≤ IGTM
IGTM
Peak gate trigger current
2.0
A
PG(AV)
Tstg
TJ
Average gate power dissipation
Storage temperature range
0.5
W
°C
°C
-40 to 150
-40 to 125
Operating junction temperature range
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — StandardTriac
Symbol
Test Conditions
VD = 12V RL = 60 Ω
Quadrant
Qxx10x4
Qxx10x5
Unit
I – II – III
25
50
50
75 (TYP)
IGT
MAX.
mA
IV
VGT
VGD
IH
VD = 12V RL = 60 Ω
VD = VDRM RL = 3.3 kΩ TJ = 125°C
IT = 200mA
I – II – III
ALL
MAX.
MIN.
MAX.
1.3
V
V
0.2
35
150
100
75
50
mA
400V
600V
800V
1000V
225
200
175
150
VD = VDRM Gate Open TJ = 125°C
dv/dt
MIN.
V/μs
VD = VDRM Gate Open TJ = 100°C
(di/dt)c = 5.4 A/ms TJ = 125°C
50
(dv/dt)c
tgt
TYP.
TYP.
2
4
V/μs
μs
IG = 2 x IGT PW = 15µs IT = 14.1 A(pk)
3.0
3.0
Note: xx = voltage, x = package, y = sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — AlternistorTriac (3 Quadrants)
Symbol
Test Conditions
VD = 12V RL = 60 Ω
Quadrant
Value
Unit
IGT
I – II – III
MAX.
50
mA
VGT
VGD
IH
VD = 12V RL = 60 Ω
VD = VDRM RL = 3.3 kΩ TJ = 125°C
IT = 100mA
I – II – III
I – II – III
MAX.
MIN.
MAX.
1.3
V
V
0.2
50
mA
400V
600V
800V
1000V
750
650
500
300
VD = VDRM Gate Open TJ = 125°C
dv/dt
MIN.
V/μs
VD = VDRM Gate Open TJ = 100°C
(di/dt)c = 5.4 A/ms TJ = 125°C
(dv/dt)c
tgt
TYP.
TYP.
30
V/μs
μs
IG = 2 x IGT PW = 15µs IT = 14.1 A(pk)
4.0
Static Characteristics
Symbol
Test Conditions
Value
1.60
10
Unit
V
VTM
ITM = 14.1A tp = 380 µs
TJ = 25°C
MAX.
MAX.
400 - 600V
400 - 800V
1000V
μA
IDRM
IRRM
VDRM = VRRM
TJ = 125°C
2
mA
TJ = 100°C
3
Thermal Resistances
Symbol
Parameter
Value
Unit
Qxx10Ryy/
1.3
2.6
45
Qxx10Nyy
Junction to case (AC)
°C/W
°C/W
Rθ(J-C)
Qxx10Lyy
Qxx10Ryy
Qxx10Lyy
Junction to ambient (AC)
Rθ(J-A)
50
Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Figure 2: Normalized DC GateTrigger Current for
All Quadrants vs. JunctionTemperature
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
4.0
3.0
2.0
1.0
0.0
MT2 POSITIVE
(Positive Half Cycle)
MT2
MT2
+
(-)
I
(+)
I
GT
GT
GATE
GATE
MT1
REF
MT2
MT1
REF
QII QI
QIII QIV
I
-
+I
GT
GT
MT2
(-)
I
(+)
I
GATE
GT
GT
GATE
+125
110
MT1
REF
-65
-40
-15
10
35
60
85
MT1
REF
-
Junction Temperature (TJ) - ºC
MT2 NEGATIVE
(Negative Half Cycle)
Note: Alternistors will not operate in QIV
Figure 3: Normalized DC Holding Current
vs. JunctionTemperature
Figure 4: Normalized DC GateTriggerVoltage for
All Quadrants vs. JunctionTemperature
4.0
3.0
2.0
1.0
0.0
2.0
1.5
1.0
0.5
0.0
+125
110
+125
110
-65
-40
-15
10
35
60
85
-65
-40
-15
10
35
60
85
Junction Temperature (TJ) - ºC
Junction Temperature (TJ) - ºC
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Figure 6: Maximum Allowable CaseTemperature
vs. On-State Current
12
10
8
130
120
110
Qxx10Ryy
Qxx10Nyy
100
Qxx10Lyy
6
90
4
80
70
60
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360
2
0
0
2
4
6
8
10
12
14
0
2
4
6
8
10
12
RMS On-State Current [IT(RMS)] - AMPS
RMS On-State Current [IT(RMS)] - AMPS
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Figure 7: Maximum Allowable AmbientTemperature
vs. On-State Current
Figure 8: On-State Current vs. On-StateVoltage
(Typical)
20
18
16
14
12
10
8
120
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive CONDUCTION
ANGLE: 360º
FREE AIR RATING - NO HEATSINK
110
TC = 25 ºC
100
90
80
Qxx10LHy
Qxx10RHy
70
60
50
40
30
20
Qxx10Ly
Qxx10Ry
6
4
2
0
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Positive or Negative Instantaneous On-State Voltage
(VT) - Volts
RMS On-State Current [IT(RMS)] - AMPS
Figure 9: Surge Peak On-State Current vs. Number of Cycles
1000
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Notes:
100
10
1
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
1
10
100
1000
Surge Current Duration - Full Cycles
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Soldering Parameters
Reflow Condition
Pb – Free assembly
tP
TP
-Temperature Min (Ts(min)
)
150°C
Ramp-up
TL
TS(max)
Pre Heat -Temperature Max (Ts(max)
)
200°C
tL
-Time (min to max) (ts)
60 – 180 secs
Ramp-down
Preheat
Average ramp up rate (LiquidusTemp)
(TL) to peak
5°C/second max
TS(min)
tS
TS(max) toTL - Ramp-up Rate
5°C/second max
217°C
-Temperature (TL) (Liquidus)
Reflow
25
time to peak temperature
-Temperature (tL)
60 – 150 seconds
260+0/-5 °C
Time
PeakTemperature (TP)
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
8 minutes Max.
280°C
Time 25°C to peakTemperature (TP)
Do not exceed
Physical Specifications
Environmental Specifications
Test
AC Blocking
Specifications and Conditions
Terminal Finish
Body Material
100% MatteTin-plated
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
UL recognized epoxy meeting flammabilty
classification 94V-0.
MIL-STD-750, M-1051, 100 cycles; -40°C
to +150°C, 15-min dwell-time
Temperature Cycling
Temperature/
Humidity
EIA/JEDEC, JESD22-A101 1008 hours;
320V - DC: 85°C; 85% rel humidity
Terminal Material
Copper Alloy
MIL-STD-750, M-1031,
1008 hours; 150°C
HighTemp Storage
Low-Temp Storage
1008 hours; -40°C
Design Considerations
Resistance to
Solder Heat
MIL-STD-750 Method 2031
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of theThyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
Solderability
Lead Bend
ANSI/J-STD-002, category 3Test A
MIL-STD-750, M-2036 Cond E
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Dimensions —TO-220AB (R-Package) — Non-Isolated MountingTab Common with Center Lead
TC MEASURING POINT
Inches
Millimeters
Min
O
8.13
.320
Dimension
A
Ø
E
P
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
MT2
B
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
C
AREA (REF.)
13.36
.526
2
0.17 in
D
7. 01
.276
F
NOTCH IN GATE LEAD
TO ID. NON-ISOLATEDTAB
R
G
F
L
G
H
J
H
K
N
J
M
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
MT1 MT2
GATE
K
L
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
R
0.965
1.22
Dimensions —TO-220AB (L-Package) — Isolated MountingTab
T
C MEASURING POINT
Inches
Millimeters
O
Dimension
8.13
.320
A
Ø
E
P
Min
Max
0.420
0.115
0.250
0.620
0.147
0.130
0.575
0.035
0.205
0.105
0.075
0.095
0.024
0.188
0.060
0.048
Min
9.65
2.67
5.84
14.99
3.61
2.79
13.72
0.64
4.95
2.41
1.52
Max
10.67
2.92
6.35
15.75
3.73
3.30
14.61
0.89
5.21
2.67
1.91
B
A
B
C
D
E
0.380
0.105
0.230
0.590
0.142
0.110
0.540
0.025
0.195
0.095
0.060
0.085
0.018
0.178
0.045
0.038
C
AREA (REF.)
2
13.36
.526
0.17 in
D
7. 01
.276
F
F
R
G
G
H
J
L
H
K
N
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
J
MT1 MT2
M
K
GATE
L
M
N
O
P
2.16
0.46
4.52
1.14
2.41
0.61
4.78
1.52
R
0.965
1.22
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Dimensions —TO-263AB (N-Package) — D2-PAK Surface Mount
TC MEASURING POINT
AREA: 0.11 IN2
Inches
Millimeters
Min
C
B
V
Dimension
E
MT2
Min
Max
0.370
0.420
0.188
0.035
0.060
0.075
0.105
0.102
0.024
0.110
0.625
0.045
0.010
0.070
Max
9.40
10.67
4.78
0.89
1.52
8.41
.331
A
B
C
D
E
0.360
0.380
0.178
0.025
0.045
0.060
0.095
0.092
0.018
0.090
0.590
0.035
0.002
0.040
9.14
9.65
4.52
0.64
1.14
7. 01
.276
A
S
W
U
J
K
GATE
MT1
8.13
.320
G
H
D
F
F
1.52
1.91
G
H
J
2.41
2.34
0.46
2.29
14.99
0.89
0.05
1.016
2.67
2.59
0.61
2.79
15.88
1.14
11.68
.460
2.16
.085
7. 01
.276
7. 01
.276
K
16.89
.665
S
8.89
.350
1.40
.055
V
3.81
.150
U
W
0.25
1.78
2.03
.080
6.60
.260
Product Selector
Voltage (xx)
Gate Sensitivity Quadrants
Part Number
Type
Package
400V
600V
800V
1000V
I – II – III
25 mA
25 mA
25 mA
50 mA
50 mA
50 mA
50 mA
50 mA
50 mA
IV
Qxx10L4
Qxx10R4
Qxx10N4
Qxx10L5
Qxx10R5
Qxx10N5
Qxx10LH5
Qxx10RH5
Qxx10NH5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
50 mA
50 mA
50 mA
StandardTriac
StandardTriac
StandardTriac
StandardTriac
StandardTriac
StandardTriac
AlternistorTriac
AlternistorTriac
AlternistorTriac
TO-220L
TO-220R
TO-263 D²-PAK
TO-220L
TYP. 75 mA
TYP. 75 mA
TYP. 75 mA
TO-220R
TO-263 D²-PAK
TO-220L
TO-220R
TO-263 D²-PAK
Packing Options
Part Number
Marking
Weight
Packing Mode
Base Quantity
Qxx10L/RyyTP
Qxx10NyyTP
Qxx10NyyRP
Qxx10L/Ryy
Qxx10Nyy
Qxx10Nyy
2.2 g
1.6 g
1.6 g
Tube Pack
Tube
500 (50 per tube)
500 (50 per tube)
500
Embossed Carrier
Note: xx = voltage, yy = type & sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
Teccor® brandThyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
TO-263 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
0.63
(16.0)
0.157
(4.0)
Gate
MT1
0.059
(1.5)
DIA
0.945
(24.0)
0.827
(21.0)
*
*
Cover tape
MT2
12.99
(330.0)
0.512 (13.0) Arbor
Hole Dia.
Dimensions
are in inches
(and millimeters).
1.01
(25.7)
Direction of Feed
Part Numbering System
Part Marking System
TO-220 AB - (L and R Package)
Q 60 10 L H5 56
TO-263 AB - (N Package)
DEVICE TYPE
Q: Triac or Alternistor
LEAD FORM DIMENSIONS
xx: Lead Form Option
VOLTAGE RATING
40: 400V
SENSITIVITY
Standard Triac:
60: 600V
Q6010R5
4: 25 mA (QI, II, III)
50 mA (QIV)
5: 50 mA (QI, II, III)
Alternistor Triac:
H5: 50mA (QI, II, III)
80: 800V
K0: 1000V
M
Y
®
CURRENT RATING
10: 10A
PACKAGE TYPE
L: TO-220 Isolated
R: TO-220 Non-Isolated
N: TO-263 (D2 Pak)
Date Code Marking
Y:Year Code
M: Month Code
XXX: Lot Trace Code
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 04/30/16
相关型号:
QK010NH556
Alternistor TRIAC, 1000V V(DRM), 10A I(T)RMS, TO-263AB, ROHS COMPLIANT, PLASTIC, D2PAK-3/2
LITTELFUSE
QK010NH5TP56
Alternistor TRIAC, 1000V V(DRM), 10A I(T)RMS, TO-263AB, ROHS COMPLIANT, PLASTIC, D2PAK-3/2
LITTELFUSE
QK010R456
4 Quadrant Logic Level TRIAC, 1000V V(DRM), 10A I(T)RMS, TO-220AB, ROHS COMPLIANT, PLASTIC PACKAGE-3
LITTELFUSE
©2020 ICPDF网 联系我们和版权申明