RLS100 [LITTELFUSE]

Electric Fuse, 100A, 600VAC, 10000A (IR), Inline/holder;
RLS100
型号: RLS100
厂家: LITTELFUSE    LITTELFUSE
描述:

Electric Fuse, 100A, 600VAC, 10000A (IR), Inline/holder

电路保护
文件: 总1页 (文件大小:77K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Fuses  
RLN/RLS Class H Fuses  
250/600 VAC • Renewable • 1 – 600 Amperes  
and increasing automation, which makes downtime very expensive,  
have greatly reduced or eliminated the cost savings attributed to  
renewable fuses.  
We recommend the use of POWR-PRO® FLSR_ID series Indicator®  
fuses for circuits between 250 and 600 volts and FLNR_ID series for  
circuits 250 volts and below. Complete information on POWR-PRO  
Indicator fuses may be found in the POWR-PRO fuse section of this  
catalog. FLNR fuses are in this section of the catalog.  
Cost Considerations  
• When comparing the cost of using renewable fuses with the cost of  
other fuses, the labor required for replacing links and the cost of addi-  
tional downtime should be included.  
Cautions  
• Renewable fuses should only be used where short-circuit currents  
are known to be less than 10,000 amperes, and where correct  
replacement of open links is assured.  
• After disassembly of fuse, examine carefully. Discard any fuses  
which show evidence of weakened tube or damaged components.  
• Remove all link residue from fuse tube.  
• Carefully clean all contact surfaces, and remove metal spatter from  
all surfaces.  
• Install the proper rated fuse link and tighten all connections  
securely.  
• Visually examine fuses for correct alignment of blades.  
Littelfuse RLN/RLS series renewable fuses are a quality product that  
have traditionally been used to provide low cost protection of general  
purpose feeder and branch circuits where available short-circuit currents  
do not exceed 10,000 amperes. However, increased levels of available  
fault current and the possibility that renewable fuses may be improperly  
renewed is a potential safety hazard. In addition, escalating labor costs  
Dimensions  
• For dimensions, please refer to NLN series for RLN dimensions and  
NLS series for RLS dimensions.  
Specifications  
Ampere Ratings  
Voltage Ratings:  
Interrupting Ratings:  
Ampere Range:  
Approvals:  
AC: 250 Volts (RLN); 600 Volts (RLS)  
AC: 10,000 amperes rms symmetrical  
1 – 600 amperes  
Standard 248-6, Class H  
UL Listed (File No: E81895)  
1
2
3
4
5
6
8**  
10  
12**  
15  
20  
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
175  
200  
225*  
250*  
300*  
350*  
400*  
450*  
500*  
600*  
100  
110  
125  
150  
CSA Certified (File No: LR29862)  
To order, specify LKN (250V) or LKS (600V) plus  
ampere rating.  
FUSE LINKS:  
*These ampere ratings require two links per fuse.  
**RLS Only.  
Example part number (series & amperage): RLN 20  
Recommended Fuse Blocks  
LH250 series (for RLN series fuses)  
LH600 series (for RLS series fuses)  
Refer to the Blocks & Holders section of this catalog for additional information.  
38  
w w w . l i t t e l f u s e . c o m  
© 2005 Littelfuse POWR-GARDProducts Catalog  

相关型号:

RLS100E

Potentiometer, Wire Wound, 150W, 100ohm, 10% +/-Tol, 1 Turn(s), ROHS COMPLIANT
OHMITE

RLS10K

POT 10K OHM 150W WIREWOUND LIN
OHMITE

RLS10KE

POT 10K OHM 150W WIREWOUND LIN
OHMITE

RLS10R

POT 10 OHM 150W WIREWOUND LINEAR
OHMITE

RLS10RE

POT 10 OHM 150W WIREWOUND LINEAR
OHMITE

RLS110

Electric Fuse, 110A, 600VAC, 10000A (IR), Inline/holder
LITTELFUSE

RLS12

Fuse
ETC

RLS125

Electric Fuse, 125A, 600VAC, 10000A (IR), Inline/holder
LITTELFUSE

RLS135

Mixer Diode, Very High Frequency to Ultra High Frequency, Silicon
ROHM

RLS135TE-11

Mixer Diode, Very High Frequency to Ultra High Frequency, Silicon
ROHM

RLS135TE-12

Mixer Diode, Very High Frequency to Ultra High Frequency, Silicon
ROHM

RLS135TE-16

Mixer Diode, Very High Frequency to Ultra High Frequency, Silicon
ROHM