RLS400 [LITTELFUSE]

Electric Fuse, 400A, 600VAC, 10000A (IR), Inline/holder;
RLS400
型号: RLS400
厂家: LITTELFUSE    LITTELFUSE
描述:

Electric Fuse, 400A, 600VAC, 10000A (IR), Inline/holder

电路保护
文件: 总1页 (文件大小:77K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Fuses  
RLN/RLS Class H Fuses  
250/600 VAC • Renewable • 1 – 600 Amperes  
and increasing automation, which makes downtime very expensive,  
have greatly reduced or eliminated the cost savings attributed to  
renewable fuses.  
We recommend the use of POWR-PRO® FLSR_ID series Indicator®  
fuses for circuits between 250 and 600 volts and FLNR_ID series for  
circuits 250 volts and below. Complete information on POWR-PRO  
Indicator fuses may be found in the POWR-PRO fuse section of this  
catalog. FLNR fuses are in this section of the catalog.  
Cost Considerations  
• When comparing the cost of using renewable fuses with the cost of  
other fuses, the labor required for replacing links and the cost of addi-  
tional downtime should be included.  
Cautions  
• Renewable fuses should only be used where short-circuit currents  
are known to be less than 10,000 amperes, and where correct  
replacement of open links is assured.  
• After disassembly of fuse, examine carefully. Discard any fuses  
which show evidence of weakened tube or damaged components.  
• Remove all link residue from fuse tube.  
• Carefully clean all contact surfaces, and remove metal spatter from  
all surfaces.  
• Install the proper rated fuse link and tighten all connections  
securely.  
• Visually examine fuses for correct alignment of blades.  
Littelfuse RLN/RLS series renewable fuses are a quality product that  
have traditionally been used to provide low cost protection of general  
purpose feeder and branch circuits where available short-circuit currents  
do not exceed 10,000 amperes. However, increased levels of available  
fault current and the possibility that renewable fuses may be improperly  
renewed is a potential safety hazard. In addition, escalating labor costs  
Dimensions  
• For dimensions, please refer to NLN series for RLN dimensions and  
NLS series for RLS dimensions.  
Specifications  
Ampere Ratings  
Voltage Ratings:  
Interrupting Ratings:  
Ampere Range:  
Approvals:  
AC: 250 Volts (RLN); 600 Volts (RLS)  
AC: 10,000 amperes rms symmetrical  
1 – 600 amperes  
Standard 248-6, Class H  
UL Listed (File No: E81895)  
1
2
3
4
5
6
8**  
10  
12**  
15  
20  
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
175  
200  
225*  
250*  
300*  
350*  
400*  
450*  
500*  
600*  
100  
110  
125  
150  
CSA Certified (File No: LR29862)  
To order, specify LKN (250V) or LKS (600V) plus  
ampere rating.  
FUSE LINKS:  
*These ampere ratings require two links per fuse.  
**RLS Only.  
Example part number (series & amperage): RLN 20  
Recommended Fuse Blocks  
LH250 series (for RLN series fuses)  
LH600 series (for RLS series fuses)  
Refer to the Blocks & Holders section of this catalog for additional information.  
38  
w w w . l i t t e l f u s e . c o m  
© 2005 Littelfuse POWR-GARDProducts Catalog  

相关型号:

RLS4148

Switching diode
ROHM

RLS4148TE-11A

0.15A, SILICON, SIGNAL DIODE
ROHM

RLS4148TE-12

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
ROHM

RLS4148TE-12A

0.15A, SILICON, SIGNAL DIODE
ROHM

RLS4148TE-15

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
ROHM

RLS4148TE-16

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
ROHM

RLS4148TE11

Switching diode
ROHM

RLS4148TE11A

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
ROHM

RLS4148TE11C

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon, LL-34, 2 PIN
ROHM

RLS4148TE12A

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon
ROHM

RLS4148_1

Switching diode
ROHM

RLS4149

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
ROHM