CLM-6-35-90-18-AA00-F2-2 [LUMINUS]
COB Arrays White LED;型号: | CLM-6-35-90-18-AA00-F2-2 |
厂家: | Luminus |
描述: | COB Arrays White LED |
文件: | 总14页 (文件大小:1845K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CLM-6 Product Datasheet
Preliminary
CLM-6 COB Arrays
White LED
Features:
• High lumen output and efficacy typical
• Over 370 lm, 114 LPW @ 3000K, 25ºC
• Over 400 lm, 125 LPW @ 5000K, 25ºC
Table of Contents
Technology Overview . . . . . .2
• Complete CCT range 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
• 80 or 90 CRI min. up to 95 min. in warm white
Test Specifications . . . . . . . . .2
Chromaticity Bins . . . . . . . . . .3
• 3-step MacAdam Ellipse color binning accuracy
• Excellent optical emission uniformity and color over angle consistency
• Exceptional long term color stability
Product Ordering & Shipping
Part Numbers . . . . . . . . . . . . . .4
• Superior thermal conductivity for uniform heat spreading
• Environmentally friendly: RoHS and REACh compliant
Product Typical Flux . . . . . . . .5
Operating Characteristics . .8
Optical and Electrical Character-
istics. . . . . . . . . . . . . . . . . . . . . . .9
Spectra . . . . . . . . . . . . . . . . . . 12
Mechanical Dimensions . . 13
Packaging Information . . . 13
Handling Notes . . . . . . . . . . 14
Applications
• Spotlights/Track Lights
• Shop Lighting
• Down Lights
• Hospitality Lighting
• Architectural and Specialty
• MR16 Replacement lamps
1
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Technology Overview
Luminus XNova™ Chip-on-Board (COB) LED series offers a complete lighting class solution designed for high performance illumination
applications. The selection covers a wide lumen range from less than 400lm to over 10,000lm, all major color temperatures and can
deliver color rendering greater than 97 at 2700K and 3000K and R9 equal to 95. These breakthroughs allow illumination engineers and
designers to develop lighting solutions with maximum efficacy, brightness and overall quality.
Reliability
UL Recognized Compliance
Designed from the ground up, the XNova™ COB LED is one of
the most reliable light sources in the world today. Having
passed a rigorous suite of environmental and mechanical stress
tests, including mechanical shock, vibration, temperature
cycling and humidity. Only then are the devices qualified for
use in a wide range of lighting application including some of the
most demanding commercial applications. Delivered with fully
qualified LM80 test data and TM21 lifetime results that certify
lumen maintenance at 35,000 hours or more, XNova™ COB LEDs
are ready for the toughest challenges.
XNova COB arrays are tested in accordance with ANSI/UL 8750
to ensure safe operation for their intended applications.
REACh & RoHS Compliance
All LED products manufactured by Luminus are REACh and
RoHS compliant and free of hazardous materials, including lead
and mercury.
Understanding XNova™ COB LED Test Specifications
Every XNova™ LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’products.
Traceability
Chromaticity Bin Range
Each XNova COB LED is marked with a 2D bar code that contains
a unique serial number. With this serial number, Luminus has
the ability to provide customers with actual test data
measurements for a specific LED. In addition, the 2D bar code is
linked to manufacturing date codes that enables traceability of
production processes and materials.
Chromaticity binning delivers color consistency for every order.
Standard products are delivered with a 3-step MacAdam ellipse.
This ensures color performance matching in the application. For
the most demanding application, Luminus is one of only a few
companies that can provide a 2-step ellipse bin. These tightly
controlled, small distribution bins provide customers
predictable, repeatable colors.
Testing Temperature
XNova™ COB products are measured at temperatures typical for
the LED operating in the fixture. Each device is tested at 85ºC
junction temperature eliminating the need to scale data sheet
specifications to real world situations.
2
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Chromaticity Bin Structure
Chromaticity Bins: 1931 CIE Curve
0.46
0.44
0.42
0.4
ANSI C78.377-2008
2-step Ellipse
3-step Ellipse
5-step Ellipse
2700K
3000K
3500K
Black Body
4000K
5000K
0.38
0.36
0.34
0.32
0.3
6500K
0.3
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0.48
0.5
CIE x
ticity Bins
hroma
White C
CLM-6
adii for
maximum r
θ °), and the
dam ellipse (
or the MacA
ientation angle f
ts, the or
enter poin
ANSI bin c
describe the
wing tables
The follo
.
eference
ovided for r
. The ANSI Bin is pr
the ellipses
5-step Bin
3-step Bin
2-step Bin
Angle
θ (°)
oint
Center P
b
a
b
a
b
a
CIEy
CIEx
CCT
0.007
0.0135
0.0139
0.01545
0.01565
0.0137
0.01115
0.0042
0.00408
0.00414
0.00402
0.00354
0.00285
0.0081
0.00834
0.00927
0.00939
0.00822
0.00669
0.0028
0.00272
0.00276
0.00268
0.00236
0.0019
0.0054
0.00556
0.00618
0.00626
0.00548
0.00446
53.7
0.4101
0.4578
2700K
3000K
3500K
4000K
5000K
6500K
0.0068
0.0069
0.0067
0.0059
0.00475
53.2
54
0.403
0.3917
0.3797
0.3553
0.3282
0.4338
0.4073
0.3818
0.3447
0.3123
53.7
59.6
58.57
*Note: Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements.
3
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Product Ordering and Shipping Part Number Nomenclature
All CLM-6 products are packaged and labeled with part numbers as outlined in the table on page 5 and 6. Luminus may include any
smaller chromaticity bin that is contained in the larger bin as part of the ordered part. When shipped, each package will contain only a
single flux and chromaticity bin. The part number designation is as follows:
CLM-6
CLM
6
NN
XX
XX
QQPP
FG
W
Light Emitting
Color
Color Render-
Voltage
Package
Chromaticity
Bin
Product Family
Flux Bin
Surface Diameter Temperature1 ing Index (CRI)2 (typical)3 Configurator
Color
See Note 1
below
6.3 : LES
Diameter (mm)
CRI See Table
Below
AA00
(Basic package)
See page 4 for
bins
CLM: Special
Volts
Lumens
Note 1: NN nomenclature corresponds to the following:
27 = 2700K
30 = 3000K
35 = 3500K
40 = 4000K
50 = 5000K
65 = 6500K
Note 2: XX Voltage typical values are
27V typical
18V typical
9V typical
Color Temperature, CRI and R9 Values
Color Temperatures
XX Value
CRI
>80
>90
R9
>0
2700K, 3000K, 3500K, 4000K, 5000K, 6500K
2700K, 3000K
80
90
>50
Note:
Luminus part numbers may be accompanied by prefixes or suffixes. The most common is the“Rev01”suffix indicating a part is fully released
and carries a full warranty. These additional characters may appear on shipping labels, packing slips and invoices. In all cases the basic part
number described above will always be included.
4
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 120mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
Color
Output Flux (lm) Reference Rendering
Index
Ordering Part Number
Typ.
Typ.
(85ºC)
Min.
(85ºC)
(calculated)
CCT
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
(25ºC)
315
245
235
290
225
215
350
270
260
80
90
95
CLM-6-27-80-27-AA00-F2-3
CLM-6-27-90-27-AA00-F2-3
CLM-6-27-95-27-AA00-F2-3
CLM-6-27-80-27-AA00-F2-2
CLM-6-27-90-27-AA00-F2-2
CLM-6-27-95-27-AA00-F2-2
2700K
330
280
260
310
260
240
370
310
290
80
90
95
CLM-6-30-80-27-AA00-F2-3
CLM-6-30-90-27-AA00-F2-3
CLM-6-30-95-27-AA00-F2-3
CLM-6-30-80-27-AA00-F2-2
CLM-6-30-90-27-AA00-F2-2
CLM-6-30-95-27-AA00-F2-2
3000K
340
290
315
265
380
320
80
90
CLM-6-35-80-27-AA00-F2-3
CLM-6-35-90-27-AA00-F2-3
CLM-6-35-80-27-AA00-F2-2
CLM-6-35-90-27-AA00-F2-2
3500K
4000K
360
305
335
280
400
335
80
90
CLM-6-40-80-27-AA00-F2-3
CLM-6-40-90-27-AA00-F2-3
CLM-6-40-80-27-AA00-F2-2
CLM-6-40-90-27-AA00-F2-2
Color
Output Flux (lm) Reference Rendering
Index
Part Number
Typ.
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
CCT
CRI (min.)
5-step MacAdam Ellipse
3-step MacAdam Ellipse
(25ºC)
5000K
6500K
370
370
340
340
400
80
80
CLM-6-50-80-27-AA00-F2-5
CLM-6-65-80-27-AA00-F2-5
CLM-6-50-80-27-AA00-F2-3
CLM-6-65-80-27-AA00-F2-3
400
*Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
5
PDS-002350 Rev 04 © 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6ProductDatasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 180mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
Color
Output Flux (lm) Reference Rendering
Index
Ordering Part Number
Typ.
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
CCT
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
(25ºC)
315
245
235
290
225
215
350
270
260
80
90
95
CLM-6-27-80-18-AA00-F2-3
CLM-6-27-90-18-AA00-F2-3
CLM-6-27-95-18-AA00-F2-3
CLM-6-27-80-18-AA00-F2-2
CLM-6-27-90-18-AA00-F2-2
CLM-6-27-95-18-AA00-F2-2
2700K
330
280
260
310
260
240
370
310
290
80
90
95
CLM-6-30-80-18-AA00-F2-3
CLM-6-30-90-18-AA00-F2-3
CLM-6-30-95-18-AA00-F2-3
CLM-6-30-80-18-AA00-F2-2
CLM-6-30-90-18-AA00-F2-2
CLM-6-30-95-18-AA00-F2-2
3000K
340
290
315
265
380
320
80
90
CLM-6-35-80-18-AA00-F2-3
CLM-6-35-90-18-AA00-F2-3
CLM-6-35-80-18-AA00-F2-2
CLM-6-35-90-18-AA00-F2-2
3500K
4000K
360
305
335
280
400
335
80
90
CLM-6-40-80-18-AA00-F2-3
CLM-6-40-90-18-AA00-F2-3
CLM-6-40-80-18-AA00-F2-2
CLM-6-40-90-18-AA00-F2-2
Color
Output Flux (lm) Reference Rendering
Index
Part Number
Typ.
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
CCT
CRI (min.)
5-step MacAdam Ellipse
5-step MacAdam Ellipse
(25ºC)
5000K
6500K
370
370
340
340
400
80
80
CLM-6-50-80-18-AA00-F2-5
CLM-6-65-80-18-AA00-F2-5
CLM-6-50-80-18-AA00-F2-3
CLM-6-65-80-18-AA00-F2-3
400
*Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
6
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Flux Bin Part Numbers
The following tables describe the products with a maximum and minimum output flux measured at 360mA and specified at 85ºC. The
values at 25ºC are calculated and shown for reference only. All product is measured and specified at 85ºC junction temperature. Luminus
may choose to ship a smaller chromaticity bin in an order for a larger.
Color
Output Flux (lm) Reference Rendering
Index
Ordering Part Number
Typ.
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
CCT
CRI (min.)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
(25ºC)
315
245
235
290
225
215
350
270
260
80
90
95
CLM-6-27-80-9-AA00-F2-3
CLM-6-27-90-9-AA00-F2-3
CLM-6-27-95-9-AA00-F2-3
CLM-6-27-80-9-AA00-F2-2
CLM-6-27-90-9-AA00-F2-2
CLM-6-27-95-9-AA00-F2-2
2700K
330
280
260
310
260
240
370
310
290
80
90
95
CLM-6-30-80-9-AA00-F2-3
CLM-6-30-90-9-AA00-F2-3
CLM-6-30-95-9-AA00-F2-3
CLM-6-30-80-9-AA00-F2-2
CLM-6-30-90-9-AA00-F2-2
CLM-6-30-95-9-AA00-F2-2
3000K
340
290
315
265
380
320
80
90
CLM-6-35-80-9-AA00-F2-3
CLM-6-35-90-9-AA00-F2-3
CLM-6-35-80-9-AA00-F2-2
CLM-6-35-90-9-AA00-F2-2
3500K
4000K
360
305
335
280
400
335
80
90
CLM-6-40-80-9-AA00-F2-3
CLM-6-40-90-9-AA00-F2-3
CLM-6-40-80-9-AA00-F2-2
CLM-6-40-90-9-AA00-F2-2
Color
Output Flux (lm) Reference Rendering
Index
Part Number
Typ.
Typ.
(85ºC)
Min..
(85ºC)
(calculated)
CCT
CRI (min.)
5-step MacAdam Ellipse
5-step MacAdam Ellipse
(25ºC)
5000K
6500K
370
370
340
340
400
80
80
CLM-6-50-80-9-AA00-F2-5
CLM-6-65-80-9-AA00-F2-5
CLM-6-50-80-9-AA00-F2-3
CLM-6-65-80-9-AA00-F2-3
400
*Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
7
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Operating Characteristics1
27V Operating Conditions
Parameter
Forward Current2
Symbol
Typical
120
Maximum
240
Unit
mA
V
If
Forward Voltage
Vf
27
31
18V Operating Conditions
Parameter
Forward Current2
Symbol
Typical
180
Maximum
360
Unit
mA
V
If
Forward Voltage
Vf
18
20
9V Operating Conditions
Parameter
Forward Current2
Symbol
Typical
360
Maximum
720
Unit
mA
V
If
Forward Voltage
Vf
9
11
Operating Conditions
Parameter
Symbol
Typical
Maximum
6.5
Unit
W
Power
3.24
Operating Case Temperature3
Light Emitting Surface Diameter
Thermal Resistance (junction-to-case)
Junction Temperature
Tc
LES
Qjc
Tj
105
ºC
6.3
mm
ºC/W
ºC
2.33
140
Viewing Angle
120
Degree
Note 1: Ratings are based on operation at a constant junction temperature of Tj = 85ºC.
Note 2: To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions
Note 3: Maximum operating case temperature combined with maximum drive current defines the total maximum operating condition for the device. To
prevent damage, please follow derating curves for all operating conditions.
Note 4: CLM-6 COB LEDs are designed for operation up to an absolute maximum forward drive current as specified above. Refer to the current vs. case
temperature derating curves for further information.
Note 5: Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye.
8
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (27V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
200.0%
180.0%
160.0%
140.0%
120.0%
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
300
250
200
150
100
50
0
0
50
100
150
200
250
300
23
24
25
26
27
28
29
30
Forward Current (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Juction Temperature
29
120.0%
28.5
28
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
27.5
27
26.5
26
5
15
25
35
45
55
65
75
85
95
105
5
15
25
35
45
55
65
75
85
95
105
Junction Temperature (ºC)
Junction Temperature (ºC)
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
0.015
0.01
0.02
0.015
0.01
0.005
0
0.005
0
-0.005
-0.01
-0.015
-0.02
-0.005
-0.01
-0.015
-0.02
5
15
25
35
45
55
65
75
85
95
105
5
15
25
35
45
55
65
75
85
95
105
Junction Temperature (ºC)
Junction Temperature (ºC)
9
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (18V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
200.0%
180.0%
160.0%
140.0%
120.0%
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
400
350
300
250
200
150
100
50
0
50
100
150
200
250
300
350
15.5
16
16.5
17
17.5
18
18.5
19
19.5
Forward Current (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Juction Temperature
19
18.5
18
120.0%
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
17.5
17
5
15
25
35
45
55
65
75
85
95
105
50
60
70
80
90
100
Junction Temperature (ºC)
Junction Temperature (ºC)
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
0.015
0.01
0.02
0.015
0.01
0.005
0
0.005
0
-0.005
-0.01
-0.015
-0.02
-0.005
-0.01
-0.015
-0.02
5
15
25
35
45
55
65
75
85
95
105
5
15
25
35
45
55
65
75
85
95
105
Junction Temperature (ºC)
Junction Temperature (ºC)
10
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics (9V)
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
200.0%
180.0%
160.0%
140.0%
120.0%
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
800
700
600
500
400
300
200
100
0
0
100
200
300
400
500
600
700
800
7.5
8
8.5
9
9.5
10
Forward Current (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Juction Temperature
120.0%
10
9.5
9
100.0%
80.0%
60.0%
40.0%
20.0%
0.0%
8.5
8
7.5
5
15
25
35
45
55
65
75
85
95
105
5
15
25
35
45
55
65
75
85
95
105
Junction Temperature (ºC)
Junction Temperature (ºC)
Change in CIEx vs. Junction Temp. (3000K, 80CRI)
Change in CIEy vs. Junction Temp. (3000K, 80CRI)
0.02
0.015
0.01
0.02
0.015
0.01
0.005
0
0.005
0
-0.005
-0.01
-0.015
-0.02
-0.005
-0.01
-0.015
-0.02
5
15
25
35
45
55
65
75
85
95
105
5
15
25
35
45
55
65
75
85
95
105
Junction Temperature (ºC)
Junction Temperature (ºC)
11
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
CLM-6 Optical & Electrical Characteristics
Typical Spectrum
120.00%
100.00%
80.00%
60.00%
40.00%
20.00%
0.00%
Warm White
Neutral White
Cool White
3000K-90CRI
3000K-97CRI
400
450
500
550
600
650
700
750
800
-20.00%
Wavelength (nm)
Typical Polar Radiation Pattern
Typical Angular Radiation Pattern
120%
100%
80%
60%
40%
20%
0%
-80
-60
-40
-20
0
20
40
60
80
Anglular Displacement (Degrees)
12
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Mechanical Dimensions
Shipping Container
Each bag is boxed for
easier storage/stacking
Trays are sealed in an
anti-static bag
5 trays are stacked together
with one tray as a cover
Label
•
Customer
Part Number
Lot ID
•
•
Quantity
13
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
CLM-6 Product Datasheet
Preliminary
Handling Notes for XNova COBs
XNova products are designed for robust performance in general lighting application. However, care must be taken when handling and
assembling the LEDs into their fixtures. To avoid damaging XNova COBs please follow these guide lines.
The following is an overview of the application notes detailing some of the practices to follow when working with these devices. More
detailed information is available on the Luminus web site at www.luminus.com.
General Handling
Electrical Contact
Devices are made to be lifted or carried with tweezers on two
adjacent corners opposite the contact pads. At no time should
the devices be handled by or should anything come in contact
with the light emitting surface (LES) area. This area includes the
yellow colored circular area and the ring surrounding it. There
are electrical connections under the LES which if damaged will
cause the device to fail.
XNova COBs are designed with contact pads on their top
surface. These pads are clearly marked with + and – polarity.
Wires can be soldered to the contact pads for electrical
connections or other solderless connector products are
available.
If wires are being soldered to the COB product, we recommend
attaching these wires prior to mounting the devices to a heat
sink. Please contact Luminus for specific recommendations on
how to solder wires if not familiar with the standard practice.
Luminus can also offer design recommendations for jigs to
allow easily soldering multiple products in rapid succession.
In addition, the ring frame itself should not be used for moving,
lifting or carrying the device. Also do not attach any optics or
mechanical holders to the ring as it is not capable to handle the
mechanical stress.
Static Electricity
Chemical Compatibility
XNova COBs are electronic devices which can be damaged by
electrostatic discharge (ESD). Please use appropriate measures
to assure the devices do not experience ESD during their
handling and or storage. ESD protection guidelines should be
used at all times when working with XNova COBs.
The resin material used to form the LES can getter hydrocarbons
from the surrounding environment. As a results, certain
chemical compounds are not recommended for use with the
XNova products. Use of these compounds can cause damage to
the light output of the device and may permanently damage
the device. Please refer to www.luminus.com for a list of the
compounds not recommended for use with the XNova COB
products.
Storage: XNova products are delivered in ESD shielded bags
and should be stored in these bags until used.
Assembly: Individuals handling XNova COBs during assembly
should be trained in ESD protection practices. Assemblers
should maintain constant conductive contact with a path to
ground by means of a wrist strap, ankle straps, mat or other ESD
protection system.
Thermal Interface Material (TIM)
Proper thermal management is critical for successful operation
of any LED system. Excess operating temperature can reduce
the light output of the device. And excessive heating can cause
permanent damage to the device. Proper TIM material is a
crucial component for effective heat transfer away from the LED
during normal operation. Please refer to www.luminus.com for
specific recommendations for TIM solutions.
Transporting: When transporting the devices from one
assembly area to another, ESD shielded carts and carriers should
be used.
14
PDS-002350 Rev 04
© 2015 Luminus Devices, Inc. - All Rights Reserved
相关型号: