CTM-14-4018-90-36-TW01 [LUMINUS]
CCT Tunable LED Spot Modules;型号: | CTM-14-4018-90-36-TW01 |
厂家: | Luminus |
描述: | CCT Tunable LED Spot Modules |
文件: | 总10页 (文件大小:1561K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
CCT Tunable LED Spot Modules
Features:
Two channel cool and warm 90+ CRI MP-1616 XNOVA Cube LEDs on metal PC board
95 CRI typical with both channels powered on
High lumen density for directional lighting
Enables system beam angles from 10 to 40 degrees
4000K to 1800K CCT range for residential and hospitality lighting
6500K to 2700K CCT range for commercial lighting
Robust design with 9000 hour LM-80 tested MP-1616 series LEDs
Consistent white light <3 SDCM
Specified “hot” performance and 100% factory tested at Tj=85°C
Applications:
Human centric lighting
Hospitality / hotel / restaurant lighting
Residential lighting
Museum and high-end retail lighting
Circadian lighting in hospitals, offices, or schools
Public, commercial buildings
Ceiling and wall mounted lights
Multi-function space lighting
Products Families
CTM-9-XXXX-YY-36-TW01: Typical 7W per channel, 9.5mm LES
CTM-14-XXXX-YY-36-TW01: Typical 15W per channel, 14.5mm LES
CTM-18-XXXX-YY-36-TW01: Typical 20W per channel, 17.5mm LES
CTM-22-XXXX-YY-36-TW01: Typical 32W per channel, 22mm LES
o
o
o
o
XXXX: CCT range (“4018” = 4000K to 1800K)
YY: minimum CRI
“36” = 36V typical voltage
TW01 = standard configuration
PDS-002951
www.luminus.com
1
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
Technical Data
Electrical data @ Tj=85°C
Nominal
forward
current
per
Nominal
input
power
per
channel
Maximum Maximum
Nominal
voltage
per
Maximum forward
input
power
per
voltage
per
channel
current
per
Part number
channel
channel
channel* channel*
CTM-9-4018-90-36-TW01
CTM-9-6527-90-36-TW01
CTM-14-4018-90-36-TW01
CTM-14-6527-90-36-TW01
CTM-18-4018-90-36-TW01
CTM-18-6527-90-36-TW01
CTM-22-4018-90-36-TW01
CTM-22-6527-90-36-TW01
200mA
200mA
400mA
400mA
550mA
550mA
875mA
875mA
7W
7W
37V
37V
37V
37V
37V
37V
37V
37V
39V
39V
39V
39V
39V
39V
39V
39V
220mA
220mA
440mA
440mA
660mA
660mA
1100mA
1100mA
9W
9W
15W
15W
20W
20W
32W
32W
18W
18W
27W
27W
45W
45W
* Note that the maximum current and maximum power per channel also serve as guidelines for maximum current
and maximum power for both channels combined. Luminaire thermal system capability and power derating
curves on page 6 must be considered, and most 2 channel drivers will limit or should limit the combined maximum
forward current of both channels per the values in the table above.
Photometric Data @ Tj=85°C and Nominal Forward Current:
CCT of Minimum Nominal
CCT of Minimum Nominal
CRI
cool
flux
flux
warm flux
flux
Part number
(min) white (lumens)
(lumens)
white (lumens)
(lumens)
650
670
415
600
850
1200
1200
1700
1850
2750
470
675
940
1350
1320
1860
2150
2950
CTM-9-4018-90-36-TW01
CTM-9-6527-90-36-TW01
CTM-14-4018-90-36-TW01
CTM-14-6527-90-36-TW01
CTM-18-4018-90-36-TW01
CTM-18-6527-90-36-TW01
CTM-22-4018-90-36-TW01
CTM-22-6527-90-36-TW01
90
90
90
90
90
90
90
90
4000K
6500K
4000K
6500K
4000K
6500K
4000K
6500K
715
740
1800K
2700K
1800K
2700K
1800K
2700K
1800K
2700K
1300
1350
1850
1900
2945
3000
1400
1490
1950
2050
3100
3250
PDS-002951
www.luminus.com
2
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
Chromaticity Bins and Ellipse Definitions @ Tj=85°C:
Center Point
Angle
3-step Bin
Nominal
CCT
CIEx
CIEy
Θ(°)
a
b
1800K
2700K
4000K
6500K
0.5656
0.4700
0.3860
0.3160
0.4136
0.4120
0.3870
0.3375
46.51
54.39
60.58
65.10
0.00989
0.00964
0.00979
0.00995
0.00476
0.00421
0.00385
0.00348
PDS-002951
www.luminus.com
3
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
Absolute Maximum Ratings & Optical/Electrical Characteristics:
Parameter
Symbol
Tc
Tj
2(Θ1/2)
Vr
Topr
Tsto
ESD
Minimum
Typical
Maximum Unit
Operating case temperature
Junction temperature
Viewing angle
105
125
°C
°C
130
degrees
volts
°C
Reverse voltage
5
+85
Ambient operating temperature
Storage temperature
Electrostatic Discharge
-40
-40
+85
°C
4000V
HBM
Mechanical Dimensions & Thermal Resistance:
Typical
Thermal
Resistance
(Rthj-c)
1.8 K/W
1.8 K/W
0.67 K/W
0.67 K/W
0.5 K/W
0.5 K/W
0.4 K/W
0.4 K/W
Light Emitting
Surface (LES)
Part Number
Diameter
9.5mm
9.5mm
14.5mm
14.5mm
17.5mm
17.5mm
22mm
Board Size
12x15mm
12x15mm
20x24mm
20x24mm
20x24mm
20x24mm
28x28mm
28x28mm
PCB Thickness
1mm
1mm
1mm
1mm
1mm
1mm
1mm
1mm
CTM-9-4018-90-36-TW01
CTM-9-6527-90-36-TW01
CTM-14-4018-90-36-TW01
CTM-14-6527-90-36-TW01
CTM-18-4018-90-36-TW01
CTM-18-6527-90-36-TW01
CTM-22-4018-90-36-TW01
CTM-22-6527-90-36-TW01
22mm
PDS-002951
www.luminus.com
4
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
PDS-002951
www.luminus.com
5
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
PDS-002951
www.luminus.com
6
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
CTM-9 Series Package Dimensions
CTM-14 Series Package Dimensions
PDS-002951
www.luminus.com
7
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
CTM-18 Series Package Dimensions
CTM-22 Series Package Dimensions
PDS-002951
www.luminus.com
8
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
Shipping Container (CTM-9)
Shipping Container (CTM-14 and CTM-18)
Similar to above but 30 pcs per tray and 150 pcs per box
Shipping Container (CTM-22)
Similar to above but 20 pcs per tray and 100 pcs per box
PDS-002951
www.luminus.com
9
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
Luminus Dynamic COB
Two Channel CCT Tunable
Datasheet
Handling Notes for Luminus COBs
Luminus products are designed for robust performance in general lighting applications; however, care must be
taken when handling and assembling the LEDs into their fixtures. To avoid damaging Luminus COBs, please follow
these guidelines. The following is an overview of the application notes detailing some of the practices to follow
hen working with these devices. More detailed information is available on the Luminus website at
www.luminus.com
General Handling
Devices are made to be lifted or carried with tweezers on two “mouse bite” locations. At no time should the
devices be handled by or should anything come in contact with the light emitting surface (LES) area. There are
electrical connections under the LES which, if damaged, will cause the device to fail.
Static Electricity
LEDs are electronic devices which can be damaged by electrostatic discharge (ESD). Please use appropriate
measures to assure the devices do not experience ESD during their handling and/or storage. ESD protection
guidelines should be used at all times when working with LEDs.
Storage: Luminus products are delivered in ESD shielded bags and should be stored in these bags until used.
Assembly: Individuals handling LEDs during assembly should be trained in ESD protection practices. Assemblers
should maintain constant conductive contact with a path to ground by means of a wrist strap, ankle straps, mat, or
other ESD protection system.
Transporting: When transporting the devices from one assembly area to another, ESD shielded carts and carriers
should be used.
Electrical Contact
Luminus COBs are designed with electrical contact pads on their top surface. These pads are clearly marked with
“+” and “-“ polarity. Wires can be soldered to the contact pads for electrical connections or other solderless
connector products are available. If wires are being soldered to the COB product, we recommend attaching these
wires prior to mounting the devices to a heat sink. Please contact Luminus for specific recommendations on how
to solder wires if not familiar with the standard practice. Luminus can also offer design recommendations for jigs
to enable easy soldering of multiple products in rapid succession.
Chemical Compatibility
The resin material used to form the emitters inside the LES can getter hydrocarbons from the surrounding
environment. As a result, certain chemical compounds are not recommended for use with Luminus products. Use
of these compounds can cause damage to the light output of the device and may permanently damage the device.
Please refer to www.luminus.com for a list of the compounds not recommended for use with Luminus COB
products.
Thermal Interface Material (TIM)
Proper thermal management is critical for successful operation of any LED system. Excess operating temperature
can reduce the light output of the device, and excessive heating can cause permanent damage to the device.
Proper TIM material is a crucial component for effective heat transfer away from the LED during normal operation.
Please refer to www.luminus.com for specific recommendations for TIM solutions.
Human Eye Safety
Caution must be taken not to stare at the light emitted from Luminus LEDs, as severe eye damage may occur.
PDS-002951
www.luminus.com
10
Luminus, Inc. · 1145 Sonora Court · Sunnyvale, CA 94086
相关型号:
©2020 ICPDF网 联系我们和版权申明