CXM-4 Product Datasheet
Generation 4
CXM-4 White LED
Pico-COB Arrays
Features:
• High lumen output and efficacy typical
Contents
• Over 440 lm, 110 LPW @ 3000K, 90CRI, Tj = 85ºC
• Over 555 lm, 140 LPW @ 5000K, 80CRI, Tj = 85ºC
Part Number Nomenclature2
CCT, CRI & R9 Specification. .2
Chromaticity Bin Structure .3
Ordering Part Numbers. . . . .4
Operating Characteristics . .7
• CCT range 2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K, 5700K and 6500K
• AccuWhite High Color Rendering, 97CRI Typ. Most CCTs
• 3 SDCM color binning standard, 2 SDCM binning available
• Excellent optical emission uniformity and color over angle consistency
• Exceptional long term color stability
Optical and Electrical Charac-
teristics . . . . . . . . . . . . . . . . . . . .8
• Superior thermal conductivity for uniform heat spreading
• Environmentally friendly: RoHS and REACH compliant
• UL recognized, file # E465703
Typical Spectrum . . . . . . . . 11
Radiation Pattern . . . . . . . . 11
Mechanical Dimension . . . 12
Shipping Container . . . . . . 12
Label Information . . . . . . . . 12
Technology Review . . . . . . 13
Test Specifications . . . . . . . 13
RoHS
REACH
Applications
• Hotel Lighting
• Spotlights/Track Lights
• Downlights
• Shop Lighting
• Hospitality Lighting
• Architectural and Specialty
Handling Notes . . . . . . . . . . 14
1
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Part Number Nomenclature
All Luminus COB products are packaged and labeled with part numbers as outlined in the table on page 4. Luminus may include any
smaller chromaticity bin that is contained in the larger bin as part of the ordered part. When shipped, each package will contain only a
single flux and chromaticity bin. The part number designation is as follows:
CXM
4
NN
XX
VV
QQPP
FG
W
Product
Family
Typical
Voltage
Package
Configurator4
Chromaticity
Bin
LES1
CCT2
Min. CRI3
Flux Bin
Chip on Board,
Multi-die
4mm LES
diameter
See Note 2
below
CRI See Table
Below
See page 3 for
bins
Volts (V)
AC40
Lumens
Notes:
1. Light Emitting Surface (LES) Diameter.
2. Correlated Color Temperature (CCT), NN nomenclature corresponds to the following:
22 = 2200K
24 = 2400K
27 = 2700k
30 = 3000k
35 = 3500K
40 = 4000K
50 = 5000K
57 = 5700K
65= 6000K
3. Minimum Color Rendering Index (CRI).
4. AC is a standard substrate; 4 means Generation 4 COB products, 0 means a product with chromaticity on the BBL.
5. Luminus part numbers may be accompanied by prefixes or suffixes. The most common is the“Rev01”suffix indicating a part is fully released and
carries a full warranty. These additional characters may appear on shipping labels, packing slips and invoices. In all cases the basic part number
described above will always be included.
CCT, CRI and R9 Values
Correlated Color Temperatures
2700K, 3000K, 3500K, 4000K, 5000K, 5700K, 6500K
2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K
2700K, 3000K
XX Value
80
CRI
>80
>90
*R9
>0
90
>50
>85
>75
95
>95
3500K, 4000K, 5000K
Note: R9 values have a tolerance of +/- 5%
2
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Chromaticity Bin Structure
Chromaticity Bins: 1931 CIE Color Space
0.48
0.46
0.44
0.42
0.4
Blackbody locus
ANSI bins C78.377-2008
Isothem lines
Standard 2-step ellipse
Standard 3-step ellipse
2400K
2700K
3000K
3500K
2200K
4000K
5000K
5700K
0.38
0.36
0.34
0.32
0.3
6500K
0.28
0.3
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0.48
0.5
0.52
CIE_x
The following tables describe the chromaticity bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum
radii for the ellipses. The ANSI Bin is provided for reference.
Center Point
Angle
θ (°)
3-step Bin
2-step Bin
CCT
CIEx
CIEy
a
b
a
b
2200K
2400K
2700K
3000K
3500K
4000K
5000K
5700K
6500K
0.5014
0.481
0.4153
0.414
53.7
53.7
53.7
53.2
54
0.0081
0.0081
0.0081
0.0042
0.0042
0.0042
0.00408
0.00414
0.00402
0.00354
0.0032
0.00285
0.0054
0.0054
0.0054
0.0028
0.0028
0.0028
0.00272
0.00276
0.00268
0.4578
0.4338
0.4073
0.3818
0.3447
0.3287
0.3123
0.4101
0.403
0.00834
0.00927
0.00939
0.00822
0.00746
0.00669
0.00556
0.00618
0.00626
0.3917
0.3797
0.3553
0.3417
0.3282
53.7
59.6
59.1
58.57
Note: Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements
3
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Ordering Part Numbers - 36V
The following tables describe products with typical flux and minimum flux measured at 120mA and specified at Tj = 85ºC. The values at
25ºC are calculated and shown for reference only.
Output Flux (lm)
Color
Rendering
Index
Ordering Part Number
CCT
Calculated
Typ. (85ºC) Min. (85ºC)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
Typ. (25ºC)
(min.)
2200K
2400K
375
390
350
365
400
415
90
90
CXM-4-22-90-36-AC40-F5-3
CXM-4-24-90-36-AC40-F5-3
CXM-4-22-90-36-AC40-F5-2
CXM-4-24-90-36-AC40-F5-2
505
415
390
470
385
365
540
445
415
80
90
95
CXM-4-27-80-36-AC40-F5-3
CXM-4-27-90-36-AC40-F5-3
CXM-4-27-95-36-AC40-F5-3
CXM-4-27-80-36-AC40-F5-2
CXM-4-27-90-36-AC40-F5-2
CXM-4-27-95-36-AC40-F5-2
2700K
3000K
3500K
4000K
5000K
520
440
405
485
410
375
555
470
435
80
90
95
CXM-4-30-80-36-AC40-F5-3
CXM-4-30-90-36-AC40-F5-3
CXM-4-30-95-36-AC40-F5-3
CXM-4-30-80-36-AC40-F5-2
CXM-4-30-90-36-AC40-F5-2
CXM-4-30-95-36-AC40-F5-2
540
460
435
500
430
405
580
490
465
80
90
95
CXM-4-35-80-36-AC40-F5-3
CXM-4-35-90-36-AC40-F5-3
CXM-4-35-95-36-AC40-F5-3
CXM-4-35-80-36-AC40-F5-2
CXM-4-35-90-36-AC40-F5-2
CXM-4-35-95-36-AC40-F5-2
550
465
425
510
430
395
590
500
455
80
90
95
CXM-4-40-80-36-AC40-F5-3
CXM-4-40-90-36-AC40-F5-3
CXM-4-40-95-36-AC40-F5-3
CXM-4-40-80-36-AC40-F5-2
CXM-4-40-90-36-AC40-F5-2
CXM-4-40-95-36-AC40-F5-2
555
470
410
515
435
380
595
505
440
80
90
95
CXM-4-50-80-36-AC40-F5-3
CXM-4-50-90-36-AC40-F5-3
CXM-4-50-95-36-AC40-F5-3
5700K
6500K
550
545
510
505
590
585
80
80
CXM-4-57-80-36-AC40-F5-3
CXM-4-65-80-36-AC40-F5-3
Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
4
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Ordering Part Numbers - 18V
The following tables describe products with typical flux and minimum flux measured at 240mA and specified at Tj = 85ºC. The values at
25ºC are calculated and shown for reference only.
Output Flux (lm)
Color
Rendering
Index
Ordering Part Number
CCT
Calculated
Typ. (85ºC) Min. (85ºC)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
Typ. (25ºC)
(min.)
2200K
2400K
375
390
350
365
400
415
90
90
CXM-4-22-90-18-AC40-F5-3
CXM-4-24-90-18-AC40-F5-3
CXM-4-22-90-18-AC40-F5-2
CXM-4-24-90-18-AC40-F5-2
505
415
390
470
385
365
540
445
415
80
90
95
CXM-4-27-80-18-AC40-F5-3
CXM-4-27-90-18-AC40-F5-3
CXM-4-27-95-18-AC40-F5-3
CXM-4-27-80-18-AC40-F5-2
CXM-4-27-90-18-AC40-F5-2
CXM-4-27-95-18-AC40-F5-2
2700K
3000K
3500K
4000K
5000K
520
440
405
485
410
375
555
470
435
80
90
95
CXM-4-30-80-18-AC40-F5-3
CXM-4-30-90-18-AC40-F5-3
CXM-4-30-95-18-AC40-F5-3
CXM-4-30-80-18-AC40-F5-2
CXM-4-30-90-18-AC40-F5-2
CXM-4-30-95-18-AC40-F5-2
540
460
435
500
430
405
580
490
465
80
90
95
CXM-4-35-80-18-AC40-F5-3
CXM-4-35-90-18-AC40-F5-3
CXM-4-35-95-18-AC40-F5-3
CXM-4-35-80-18-AC40-F5-2
CXM-4-35-90-18-AC40-F5-2
CXM-4-35-95-18-AC40-F5-2
550
465
425
510
430
395
590
500
455
80
90
95
CXM-4-40-80-18-AC40-F5-3
CXM-4-40-90-18-AC40-F5-3
CXM-4-40-95-18-AC40-F5-3
CXM-4-40-80-18-AC40-F5-2
CXM-4-40-90-18-AC40-F5-2
CXM-4-40-95-18-AC40-F5-2
555
470
410
515
435
380
595
505
440
80
90
95
CXM-4-50-80-18-AC40-F5-3
CXM-4-50-90-18-AC40-F5-3
CXM-4-50-95-18-AC40-F5-3
5700K
6500K
550
545
510
505
590
585
80
80
CXM-4-57-80-18-AC40-F5-3
CXM-4-65-80-18-AC40-F5-3
Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
5
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Ordering Part Numbers - 9V
The following tables describe products with typical flux and minimum flux measured at 480mA and specified at Tj = 85ºC. The values at
25ºC are calculated and shown for reference only.
Output Flux (lm)
Color
Rendering
Index
Ordering Part Number
CCT
Calculated
Typ. (85ºC) Min. (85ºC)
3-step MacAdam Ellipse
2-step MacAdam Ellipse
Typ. (25ºC)
(min.)
2200K
2400K
375
390
350
365
400
415
90
90
CXM-4-22-90-9-AC40-F5-3
CXM-4-24-90-9-AC40-F5-3
CXM-4-22-90-9-AC40-F5-2
CXM-4-24-90-9-AC40-F5-2
505
415
390
470
385
365
540
445
415
80
90
95
CXM-4-27-80-9-AC40-F5-3
CXM-4-27-90-9-AC40-F5-3
CXM-4-27-95-9-AC40-F5-3
CXM-4-27-80-9-AC40-F5-2
CXM-4-27-90-9-AC40-F5-2
CXM-4-27-95-9-AC40-F5-2
2700K
3000K
3500K
4000K
5000K
520
440
405
485
410
375
555
470
435
80
90
95
CXM-4-30-80-9-AC40-F5-3
CXM-4-30-90-9-AC40-F5-3
CXM-4-30-95-9-AC40-F5-3
CXM-4-30-80-9-AC40-F5-2
CXM-4-30-90-9-AC40-F5-2
CXM-4-30-95-9-AC40-F5-2
540
460
435
500
430
405
580
490
465
80
90
95
CXM-4-35-80-9-AC40-F5-3
CXM-4-35-90-9-AC40-F5-3
CXM-4-35-95-9-AC40-F5-3
CXM-4-35-80-9-AC40-F5-2
CXM-4-35-90-9-AC40-F5-2
CXM-4-35-95-9-AC40-F5-2
550
465
425
510
430
395
590
500
455
80
90
95
CXM-4-40-80-9-AC40-F5-3
CXM-4-40-90-9-AC40-F5-3
CXM-4-40-95-9-AC40-F5-3
CXM-4-40-80-9-AC40-F5-2
CXM-4-40-90-9-AC40-F5-2
CXM-4-40-95-9-AC40-F5-2
555
470
410
515
435
380
595
505
440
80
90
95
CXM-4-50-80-9-AC40-F5-3
CXM-4-50-90-9-AC40-F5-3
CXM-4-50-95-9-AC40-F5-3
5700K
6500K
550
545
510
505
590
585
80
80
CXM-4-57-80-9-AC40-F5-3
CXM-4-65-80-9-AC40-F5-3
Note: Luminus maintains a +/- 6% tolerance on flux measurements.
Luminus maintains a +/- 2% tolerance on CRI measurements.
6
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Operating Characteristics1
Parameter - 36V
Forward Current2
Forward Voltage3
Symbol
Minimum
Typical
120
Maximum
400
Unit
mA
V
If
Vf
31.0
33.8
37.0
Parameter - 18V
Forward Current2
Forward Voltage3
Symbol
Minimum
Typical
240
Maximum
800
Unit
mA
V
If
Vf
15.5
16.9
18.5
Parameter - 9V
Symbol
Minimum
Typical
480
Maximum
1600
Unit
mA
V
Forward Current2
Forward Voltage3
If
Vf
7.7
8.46
9.3
Parameter
Symbol
Minimum
Typical
4.0
Maximum
15.7
Unit
W
Power
Operating Case Temperature
Light Emitting Surface Diameter
Thermal Resistance (junction-to-case)
Junction Temperature
Viewing Angle
Tc
LES
Qjc
Tj
120
ºC
4.5
mm
ºC/W
ºC
1.43
140
120
Degree
Notes:
1. Ratings are based on operation at a constant junction temperature of Tj = 85ºC.
2. To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions
3. Voltage is rated at typical forward current. For voltage at higher drive current, refer to performance graphs.
4. Device operation not recommended at drive currents less than 10% of the typical value
5. Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye.
6. All product operating specifications are subject to change without advance notice.
7
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Optical & Electrical Characteristics - 36V
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
300%
400
350
300
250
200
150
100
50
250%
200%
150%
100%
50%
0%
0
0
50
100
150
200
250
300
350
400
31
32
33
34
35
36
37
38
39
Forward Curremt (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Junction Temperature
120%
110%
100%
90%
35
34.5
34
33.5
33
32.5
32
80%
20
30
40
50
60
70
80
90
100
110
120
0
20
40
60
80
100
120
Junction Temperature (℃)
Junction Temperature (℃)
Change in CIE_x/y vs. Junction Temp. (3000K, 90CRI)
Change in CIE_x/y vs. Forward Current (3000K, 90CRI)
0.003
0.01
ΔCIE_x
ΔCIE_y
ΔCIE_x
ΔCIE_y
0.002
0.001
0
0.005
0
-0.005
-0.01
-0.001
-0.002
0
20
40
60
80
100
120
0
40
80
120
160
200
240
280
320
360
400
Forward Current (mA)
Junction Temperature (℃)
8
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Optical & Electrical Characteristics - 18V
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
300%
800
700
600
500
400
300
200
100
250%
200%
150%
100%
50%
0%
100
200
300
400
500
600
700
800
15.5
16
16.5
17
17.5
18
18.5
19
19.5
Forward Curremt (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Junction Temperature
120%
110%
100%
90%
17.5
17
16.5
16
80%
20
30
40
50
60
70
80
90
100
110
120
0
20
40
60
80
100
120
Junction Temperature (℃)
Junction Temperature (℃)
Change in CIE_x/y vs. Junction Temp. (3000K, 90CRI)
Change in CIE_x/y vs. Forward Current (3000K, 90CRI)
0.003
0.01
ΔCIE_x
ΔCIE_y
ΔCIE_x
ΔCIE_y
0.002
0.001
0
0.005
0
-0.005
-0.01
-0.001
-0.002
0
20
40
60
80
100
120
0
80
160
240
320
400
480
560
640
720
800
Forward Current (mA)
Junction Temperature (℃)
9
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Optical & Electrical Characteristics - 9V
Relative Output Flux vs. Forward Current @ 85ºC
Forward Current vs. Forward Voltage @ 85ºC
300%
1600
1400
1200
1000
800
600
400
200
0
250%
200%
150%
100%
50%
0%
0
200
400
600
800
1000
1200
1400
1600
7.5
8
8.5
9
9.5
10
Forward Curremt (mA)
Forward Voltage (V)
Relative Output Flux vs. Junction Temperature
Change in Voltage vs. Junction Temperature
120%
110%
100%
90%
8.8
8.6
8.4
8.2
8
80%
20
30
40
50
60
70
80
90
100
110
120
0
20
40
60
80
100
120
Junction Temperature (℃)
Junction Temperature (℃)
Change in CIE_x/y vs. Junction Temp. (3000K, 90CRI)
Change in CIE_x/y vs. Forward Current (3000K, 90CRI)
0.003
0.01
ΔCIE_x
ΔCIE_y
ΔCIE_x
ΔCIE_y
0.002
0.001
0
0.005
0
-0.005
-0.01
-0.001
-0.002
0
20
40
60
80
100
120
0
160
320
480
640
800
960
1120
1280
1440
1600
Forward Current (mA)
Junction Temperature (℃)
10
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Typical Spectrum
6500K
5000K
4000K
3500K
3000K
2700K
2400K
380
430
480
530
580
630
680
730
780
Radiation Pattern
Typical Polar Radiation Pattern
Typical Angular Radiation Pattern
120%
100%
80%
60%
40%
20%
0%
-80
-60
-40
-20
0
20
40
60
80
Anglular Displacement (Degrees)
11
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Mechanical Dimensions
Note: Unless otherwise specified, tolerance is 0.3mm
0.87±0.15
.034±.006
13.50±0.25
.531±.010
2X 0.85
.033
2X 0.85
.033
1.37
.054
5.50
.217
RING O.D.
4.5 LES
13.50±0.25
.531±.010
2X 2.02
.079
1.00
.039
TcPOINT
0.50±0.10
.020±.004
2X 2.02
.079
2X 0.20±0.10
.008±.004
RING HEIGHT
Shipping Container
Package model -- for illuminaꢀon
Note: 80 pcs per tray and 5 trays
are stacked together to be
sealed in an anti-static bag.
Note: The anti-static bag is
boxed for easier storage,
400 pcs per box.
Label Information
Notes:
①
① Manufacture part number, flux bin and chromaꢀcity bin
② Customer part number
②
③
③ Rev.01 indicates a fully released product
④ Box ID
⑥
⑤
⑤ Producꢀon ID
④
⑥ Total number of units in a box
Label model -- for illuminaꢀon only
12
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Technology Overview
Luminus Chip-on-Board (COB) LED series offers a complete lighting class solution designed for high performance illumination
applications. The selection covers a wide lumen range from less than 300lm to over 25,000lm, all major color temperatures and can
deliver color rendering greater than 97 at 2700K and 3000K and R9 equal to 95. These breakthroughs allow illumination engineers and
designers to develop lighting solutions with maximum efficacy, brightness and overall quality.
Reliability
Designed from the ground up, the Luminus COB LED is one of the most reliable light sources in the world today. Having passed a
rigorous suite of environmental and mechanical stress tests, including mechanical shock, vibration, temperature cycling and humidity.
Only then are the devices qualified for use in a wide range of lighting application including some of the most demanding commercial
applications. Delivered with fully qualified LM80 test data and TM21 lifetime results that certify lumen maintenance at 50,000 hours or
more, Luminus COB LEDs are ready for the toughest challenges.
UL Recognized Compliance
Luminus COB arrays are tested in accordance with ANSI/UL 8750 to ensure safe operation for their intended applications.
REACH & RoHS Compliance
All LED products manufactured by Luminus are REACH and RoHS compliant and free of hazardous materials, including lead and mercury
Test Specifications
Every Luminus LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’products.
Traceability
Each Luminus COB LED is marked with a 2D bar code that contains a unique serial number. With this serial number, Luminus has the
ability to provide customers with actual test data measurements for a specific LED. In addition, the 2D bar code is linked to
manufacturing date codes that enables traceability of production processes and materials.
Testing Temperature
Luminus COB products are measured at temperatures typical for the LED operating in the fixture. Each device is tested at 85ºC junction
temperature eliminating the need to scale data sheet specifications to real world situations.
Chromaticity Bin Range
Chromaticity binning delivers color consistency for every order. Standard products are delivered with a 3-step MacAdam ellipse. This
ensures color performance matching in the application. For the most demanding application, Luminus is one of only a few companies
that can provide a 2 SCDM bin distribution. These tightly controlled, small distribution bins provide customers predictable, repeatable
colors.
13
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Handling Notes
Luminus products are designed for robust performance in general lighting application. However, care must be taken when handling and
assembling the LEDs into their fixtures. To avoid damaging Luminus COBs please follow these guidelines.
The following is an overview of the application notes detailing some of the practices to follow when working with these devices. More
detailed information is available on the Luminus web site at www.luminus.com.
General Handling
Devices are made to be lifted or carried with tweezers on two adjacent corners opposite the contact pads. At no time should the devices
be handled by or should anything come in contact with the light emitting surface (LES) area. This area includes the yellow colored
circular area and the ring surrounding it. There are electrical connections under the LES which if damaged will cause the device to fail. In
addition, the ring frame itself should not be used for moving, lifting or carrying the device. Also do not attach any optics or mechanical
holders to the ring as it is not capable to handle the mechanical stress.
Storage Condition
Please follow the conditions below.
Temperature 5~30 ºC, relative humidity less than 60%.
Before opened
Note: before opened LED should be used within a year
Temperature 5~30ºC, relative humidity less than 60%. Please apply soldering within one week.
After opened
After opened LED should be kept in an aluminum moisture proof bag with a moisture absorbent material
Avoid exposing to air with corrosive gas. If exposed, electrode surface would be damaged, which may affect
Avoid
soldering. Furthermore, if the device is stored in an environment which contain elements that could volatize resin
corrosive gas
material, then the volatized resin particles may stick to electrodes, which may result in connection failures.
Static Electricity
Luminus COBs are electronic devices which can be damaged by electrostatic discharge (ESD). Please use appropriate measures to assure
the devices do not experience ESD during their handling and or storage. ESD protection guidelines should be used at all time when
working with Luminus COBs.
Storage
Luminus products are delivered in ESD shielded bags and should be stored in these bags until used
Transporting
When transporting the devices from one assembly area to another, ESD shielded carts and carriers should be used
Individuals handling Luminus COBs during assembly should be trained in ESD protection practices. Assemblers
should maintain constant conductive contact with a path to ground by means of a wrist strap, ankle straps, mat or
other ESD protection system
Assembly
14
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
CXM-4 Product Datasheet
Chemical Compatibility
The resin material used to form the LES can getter hydrocarbons from the surrounding environment. As a result, certain chemical
compounds (HꢀSOꢁ, HꢀS, SOꢀ, NHꢂ, HꢂPOꢁ etc.) are not recommended for use with the Luminus products. Use of these compounds can
cause damage to the light output of the device and may permanently damage the device. Please refer to the table below for a list of the
compounds not recommended for use with the Luminus COB products.
Common Chemicals Know to Adversely Affect Luminus Devices
Acetates
Acetic acid
Acrylates
Aldehydes
Aldehydes
Amines
Ethers
Cl, F or Br containing compounds
Liquid hydrocarbons
Hydrochloric Acid
Ketones
Potassium hydroxide
Siloxanes, fatty acids
Sodium Hydroxide
Sulfur compounds
Sulfuric Acid
Nitric Acid
Toluene
Benzene
Dienes
Phosphoric acid
Xylenes
Thermal Interface Material (TIM)
Proper thermal management is critical for successful operation of any LED system. Excess operating temperature can reduce the light
output of the device. And excessive heating can cause permanent damage to the device. Proper TIM material is a crucial component for
effective heat transfer away from the LED during normal operation. Please refer to www.luminus.com for specific recommendations for
TIM solutions.the compounds not recommended for use with the Luminus COB products.
15
Luminus Devices, Inc. • www.luminus.com
1145 Sonora Court Sunnyvale, CA 94086 USA
PDS-003035 Rev 01
© 2019 Luminus Devices, Inc. - All Rights Reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明