FM200BBYYY [TE]

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc; KILOVAC FM200 ( “ FLATMAN ” )系列1-, 2-或3极接触器触点额定200安培, 480VAC ( 50/60赫兹)或48V直流
FM200BBYYY
型号: FM200BBYYY
厂家: TE CONNECTIVITY    TE CONNECTIVITY
描述:

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
KILOVAC FM200 ( “ FLATMAN ” )系列1-, 2-或3极接触器触点额定200安培, 480VAC ( 50/60赫兹)或48V直流

异步传输模式 ATM
文件: 总2页 (文件大小:168K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor  
With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc  
Product Facts  
Multi-pole configurations  
Normally open, normally  
closed and mixed contact  
arrangements  
Optional quick connect tabs  
for sensing  
Small, lightweight & cost-  
effective – designed to be the  
smallest, lowest cost  
contactor in the industry with  
its current rating  
Standard models available  
with 12VDC, 24VDC and 115  
VAC coils. Consult factory for  
240VAC coil models.  
1 Form A auxiliary contacts  
For factory-direct application assistance, dial  
800-253-4560, ext. 2055, or 805-220-2055.  
File E208033  
Product Specifications  
Parameter  
Units  
Value for FM200 Series  
Coil Operating Voltage (valid over temperature range)  
Contact Arrangement  
1, 2 or 3 poles  
Coil Designator  
Nominal Voltage  
Voltage Range  
Hold Voltage  
Units  
A
B
C
D
Contact Form (per pole)  
Rated Operating Voltage  
Max. Contact Voltage (transient)  
Continuous (Carry) Current  
Form X or Y (NO-DM or NC-DB)  
480Vrms (L-L) or 48VDC  
750Vrms or 60VDC  
V
V
V
V
12 (DC)  
9.6-13.2  
24 (DC)  
115 (AC)  
24 (DC)  
V
V
19.2-26.4 92-126.5 19.2-26.4  
0.5V  
0.1V  
0.5V  
0.1V  
0.5V  
0.1V  
0.5V  
0.2V  
nom  
nom  
nom  
nom  
nom  
nom  
nom  
nom  
Arms or ADC 200/pole (Form X)  
150/pole (Form Y)  
Dropout Voltage  
Power Switching Form X (0.7-1.0 PF)  
Cycles  
2,000 @ 300Arms  
10,000@ 200Arms  
20,000 @ 100Arms  
5,000 @ 200A/48VDC  
2 million @ 50A/28VDC  
Coil Resistance Data for Pole Configurations (@25°C)  
Coil Designator  
Units  
A
B*  
C*  
D*  
Resistance 10ꢀ  
Ohms  
X = 36  
XX = 18  
XXX = 12  
X = 36  
XX = 18  
XXX = 12  
X = 36  
XX = 18  
XXX = 12 YYY = 6.9  
Y = 20.8  
YY = 10.4  
Power Switching Form Y (0.7-1.0 PF)  
Cycles  
2,000 @ 225Arms  
10,000@ 150Arms  
20,000 @ 75Arms  
XY = 13.2 XY = 13.2 XY = 13.2 YXY = 8.1  
XYX = 9.6 XYX = 9.6 XYX = 9.6  
5,000 @ 150A/48VDC  
2 million @ 35A/28VDC  
*Coil resistance not measurable at terminals due to converter/economizer circuit.  
Mechanical Life  
Cycles  
mV  
>2 million  
Contact Voltage Drop  
Auxiliary Contact Arrangement  
Auxiliary Contact Rating  
Dielectric Withstanding Voltage  
Insulation Resistance @ 500VDC  
Shock, 11ms 1/2 sine, peak  
Vibration, sine, 10-2000Hz.  
Operating Temperature  
Storage Temperature  
75 for Form X or Form Y  
1 Form A (SPST-NO)  
Coil Current/Power Data for Pole Configurations (@25°C, V =1.1V  
)
nom  
coil  
Coil Designator  
Current/Power  
A
B**  
Arms or ADC 1 @ 30VDC, 3 @ 125VAC  
Vrms 2,200 @ sea level  
Megohms 100  
X = 0.37 ADC / 4.84W  
XX = 0.73ADC / 9.68W  
XXX = 1.1ADC / 14.5W  
XY = 1.0ADC / 13.2W  
XYX = 1.38ADC / 18.2W  
X = 0.33ADC / 3.9W  
XX = 0.65ADC / 7.6W  
XXX = 0.97ADC / 11.3W  
XY = 0.98ADC / 12.7W  
XYX = 1.31ADC / 16.5W  
G
G
10  
5
Coil Designator  
Current/Power  
C
D***  
Y = 0.13ADC / 3.4W  
XX = 0.115Arms / 11.6VA YY = 0.23ADC / 6.1W  
Pick-Up I / Duration  
°C  
-20 to +60  
-40 to +85  
0 to 95  
X = 0.067 Arms / 6.8VA  
1.28ADC / 75ms  
2.4ADC / 75ms  
°C  
Ambient Humidity  
ꢀRH  
oz. / kg  
XXX = 0.146Arms / 14.8VA YYY = 0.34ADC / 9.0W 3.0ADC / 75ms  
XY = 0.074Arms / 7.5VA YXY = 0.28ADC / 7.4W 3.0ADC / 75ms  
XYX = 0.161Arms / 16.3VA  
Weight  
17.6 - 49.4 / 0.5 -1.4  
See Outline Dimensions for model-specific weight information.  
**Average coil current.  
***Economized.  
Available Pole Configurations and Applicable Coil Codes  
No. of NC Poles (across)  
No. of NO Poles (down)  
0
1
2
3
Operate/Release Time (25°C, 0.8V  
V < V ) Typ.  
nom  
nom  
Coil Designator  
Operate Time  
Release Time  
Bounce Time  
Units  
ms  
A
B****  
30-50  
70-80  
2-5  
C****  
50-150  
75-100  
2-5  
D****  
20-30  
75-100  
2-5  
0
1
2
3
Y
YY  
Coil D  
YYY  
Coil D  
25-50  
10-20  
2-5  
Coil D  
X
XY  
YXY  
Coil D  
ms  
Coil A/B/C/E Coil A/B/C/E  
ms  
XX XYX  
Coil A/B/C/E Coil A/B/C/E  
****Includes internal coil suppression.  
XXX  
Coil A/B/C/E  
© 2003 and 2007 by Tyco Electronics Corporation. All Rights Reserved.  
FLATMAN, KILOVAC and TE Logo and Tyco Electronics are trademarks.  
X = Form X (NO-DM) Y = Form Y (NC-DB)  
1
Catalog 1654769  
Issued 11-07  
Dimensions are in inches and  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA: 1-800-522-6752  
South America: 55-11-3611-1514  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
millimeters unless otherwise  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-5-729-0425  
specified. Values in brackets  
are metric equivalents.  
www.tycoelectronics.com  
UK: 44-141-810-8967  
200 Amp, 480Vac or 48Vdc Contactor  
with 1, 2 or Poles  
KILOVAC FM200 Series (FLATMAN) (Continued)  
Part Numbering System  
Typical Part Number  
Series:  
FM200  
A
B
XYX  
FM200 = Multipole, 200 Amp, 480VAC/48VDC Contactor  
Control Voltage:  
A = 12VDC Coil, No Suppression  
B = 24VDC Converter, with Suppression  
C = 115VAC Converter, with Suppression  
D = 24VDC Electronic Chopper, with Suppression  
E = 240VAC Converter, with Suppression - Consult Factory for Availability and Specifications  
Optional Termination:  
A = Optional Quick Connect Tabs  
B = No Optional Terminals  
Pole Configuration (All models have a 1 Form A (SPST-NO) auxiliary switch):  
X = 1 Form X (SPST-NO-DM), Available with control voltage codes A, B, C and E  
XX = 2 Form X (2PST-NO-DM), Available with control voltage codes A, B, C and E  
XXX = 3 Form X (3PST-NO-DM), Available with control voltage codes A, B, C and E  
Y = 1 Form Y (SPST-NC-DB), Available only with control voltage code D  
YY = 2 Form Y (DPST-NC-DB), Available only with control voltage code D  
YYY = 3 Form Y (3PST-NC-DB), Available only with control voltage code D  
XY = 1 Form X (SPST-NO-DM) + 1 Form Y (SPST-NC-DB), Available with control voltage codes A, B, C and E  
XYX = 1 Form X (SPST-NO-DM) + 1 Form Y (SPST-NC-DB) + 1 Form X (SPST-NO-DM), Available with control voltage codes A, B, C and E  
YXY = 1 Form Y (SPST-NC-DB) + 1 Form X (SPST-NO-DM) + 1 Form Y (SPST-NC-DB), Available only with control voltage code D  
Outline Dimensions  
2.29  
.40  
(58.2)  
(10.2)  
1.86  
(47.2)  
C
OPTIONAL TAB  
TERMINALS  
.250 x .032  
(6.35 x .813)  
MAIN TERMINAL  
WIRE CONNECT  
VIA M8 BOLT W/LOCK/FLAT  
13MM (0.5 IN) HEX HEAD  
3.77  
(95.8)  
2.29  
(58.2)  
1.93  
(49.0)  
1.22  
(31.0)  
4.2  
(106.7)  
RIGHT ANGLE SCREW  
TERMINAL STRIP  
ACCEPTS  
A
#24 - #14 WIRE  
NUMBER OF POLES  
DIM.  
1
2
3
1.68  
(42.7)  
2.67  
(67.7)  
3.65  
(92.7)  
A
2.74  
(69.6)  
3.42  
(86.9)  
2.14  
(54.3)  
3.12  
(79.3)  
4.11  
(104.4)  
B
C
2.98  
(75.7)  
3.77  
(95.8)  
1.56  
(39.6)  
2.55  
(64.6)  
3.53  
(89.7)  
17.6 oz.  
(0.5 kg)  
35.3 oz.  
(1.0 kg)  
49.4 oz.  
(1.4 kg)  
WEIGHT  
.256 DIA.  
(6.5)  
B
For factory-direct application assistance, dial  
800-253-4560, ext. 2055, or 805-220-2055.  
1654769 – 0M – KRG – PDF – 11-07  
Printed in U.S.A.  
2
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in brackets  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA: 1-800-522-6752  
South America: 55-11-3611-1514  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
www.tycoelectronics.com  
C. America: 52-55-5-729-0425  
UK: 44-141-810-8967  

相关型号:

FM200CAX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAXX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAXXX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
TE

FM200CAXXX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAXY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAXYX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
TE

FM200CAXYX

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAYXY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
TE

FM200CAYXY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAYY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
MACOM

FM200CAYYY

KILOVAC FM200 (“FLATMAN”) Series 1-, 2- or 3-pole Contactor With Contacts Rated 200 Amps, 480Vac (50/60 Hz. ) or 48Vdc
TE