General Purpose Relays 通用继电器
SR6C6K60 数据手册
通过下载SR6C6K60数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载General Purpose Relays
Safety Relay SR6
I
6 pole safety relay with either
4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts
Forcibly guided contacts according to EN50205
Rated current 8 A
I
I
I
I
coil power 800 mW or 1200 mW
RoHS compliant (Directive 2002/95/EC)
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-DS
Approvals (in preperation)
V
REG.-Nr. 128935,
Z
E214024,
T
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 3 NC contacts
4 NO contacts and 2 NC contacts
5 NO contacts and 1 NC contact
single contact, forcibly guided
type A according to EN 50205
micro disconnection
8 A
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Contact material
240 / 400 VAC
2000 VA
800 mW version
1200 mW version
AgSnO2 + 0,2 μm Au
AgSnO2
Minimum contact load
Contact resistance
10 mA / 5 V
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
10x106 cycles
Mechanical endurance
Rated frequency of operation with / without load
6 min-1 / 150 min-1
Contact ratings
Type
Load
Cycles
SR6 NO contact
SR6 NC contact
SR6 NO contact
SR6 NO contact
8A, 250VAC, resistiv, 70°C, EN61810-1
8A, 250VAC, resistiv, 70°C, EN61810-1
5A, 250VAC, AC15, 70°C, EN60947-5-1
5A, 24VDC, DC13, 25°C, EN60947-5-1
50x103
20x103
50x103
45x103
Coil data
800 mW
1200 mW
Rated coil voltage range DC coil
Coil power DC coil
5...110 VDC
appr. 800 mW
appr. 1200 mW
Operative range
Coil versions, 800 mW, DC-coil
Coil code
Order. code voltage
2
Nominal
Pull-in
voltage
VDC
3.8
Release
voltage
VDC
0.5
Coil
resistance
c
Rated coil
power
mW
block 4
K05
K06
K09
K12
K18
K21
K24
K36
K40
K48
K60
K85
L10
VDC
5
6
9
12
18
21
24
36
40
48
60
85
110
31+10%
45+10%
806
4.5
0.6
800
6.8
9.0
0.9
101+10%
180+10%
405+10%
551+10%
720+10%
1620+10%
2000+10%
2880+10%
4500+10%
9031+10%
15130+10%
802
1.2
800
13.5
15.8
18.0
27.0
30.0
36.0
45.0
63.8
82.5
1.8
800
2.1
800
2.4
800
3.6
800
4.0
800
4.8
800
6.0
800
8.5
800
11.0
800
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. FC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2006/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.
General Purpose Relays
Safety Relay SR6 (Continued)
Coil versions, 1200 mW, DC-coil
Coil
Rated
voltage
VDC
12
Operate
voltage
VDC
9.0
Release/Reset
Coil
resistance
c
120+10%
270+10%
368+10%
480+10%
1920+10%
10080+12%
Rated coil
power
mW
code
voltage
VDC
1.2
012
018
021
024
048
110
1200
18
13.5
1.8
1200
21
15.8
2.1
1198
24
18.0
2.4
1200
48
36.0
4.8
1200
110
82.5
11.0
1200
All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
Insulation resistance coil-contact circuit
Dielectric strength coil-contact circuit
open contact circuit
> 100x106 Ohm
4000 Vrms
1500 Vrms
adjacent contact circuits
3000 Vrms
Clearance / creepage coil-contact circuit
adjacent contact circuits
W 5.5 / 5.5 mm
W 5.5 / 5.5 mm
W IIIa
PCB layout / terminal assignment
Bottom view
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
open contact circuit
PTI 250
4 NO+2 NC and 3 NO+3 NC versions
basic
functional
basic
250 V
2
230/400 V
III
adjacent contact circuits
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
S0368-CA
Insulation to EN 50178
Type of insulation coil-contact circuit
adjacent contact circuits
reinforced
reinforced
Other data
RoHS - Directive 2002/95/EC
Ambient temperature range
Vibration resistance (function) NO / NC contact
Shock resistance (function) NO / NC contact
Category of protection
compliant
-25...+70°C
S0368-CB
> 10 / 2.5 g, 10....200 Hz
> 10 / 2.5 g, 16 ms half sine
RT III 1)
Resistance to soldering heat
Relay weight
260°C / 5 s
30 g
Packaging unit
10 pcs
1) please contact technical support for washing parameters
Accessories
PCB socket and hold down clip
S0368-CC
contact technical support
5 NO + 1 NC version
Dimensions
S0368-CE
S0367-DN
S0368-CD
2
Datasheet
Rev. FC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
‘Schrack’ section.
Issued 2006/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
only to be used together
with the 'Definitions' at
schrackrelays.com in the
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.
General Purpose Relays
Safety Relay SR6 (Continued)
Product key
S R 6
Type
Contact configuration
A
B
3 NO + 3 NC contacts
4 NO + 2 NC contacts
C
5 NO + 1 NC contacts
Contact material
4
6
AgSnO2, for 1200 mW version only
AgSnO2 + 0.2 μm Au, for 800 mW version only
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Available types please see Part Number table
800 mW version
Product key
SR6A6K05
SR6B6K05
SR6C6K05
SR6A6K06
SR6B6K06
SR6C6K06
SR6A6K09
SR6B6K09
SR6C6K09
SR6A6K12
SR6B6K12
SR6C6K12
SR6A6K15
SR6B6K15
SR6C6K15
SR6A6K18
SR6B6K18
SR6C6K18
SR6A6K21
SR6B6K21
SR6C6K21
SR6A6K24
SR6B6K24
SR6C6K24
SR6A6K36
SR6B6K36
SR6C6K36
SR6A6K40
SR6B6K40
SR6C6K40
SR6A6K48
SR6B6K48
SR6C6K48
SR6A6K60
SR6B6K60
SR6C6K60
SR6A6K85
SR6B6K85
SR6C6K85
SR6A6L10
SR6B6L10
SR6C6L10
Type
6-pole
safety relay
Contact material Contact configuration
Coil
Part number
5-1415537-8
7-1415537-2
8-1415537-7
5-1415537-9
7-1415537-4
8-1415537-8
6-1415537-0
7-1415537-5
8-1415537-9
6-1415537-1
7-1415537-6
9-1415537-0
6-1415537-2
7-1415537-7
9-1415537-1
6-1415537-3
7-1415537-8
9-1415537-2
6-1415537-4
7-1415537-9
9-1415537-3
6-1415537-5
8-1415537-0
9-1415537-4
6-1415537-6
8-1415537-1
9-1415537-5
6-1415537-7
8-1415537-2
9-1415537-6
6-1415537-8
8-1415537-3
9-1415537-7
6-1415537-9
8-1415537-4
9-1415537-8
7-1415537-0
8-1415537-5
9-1415537-9
7-1415537-1
8-1415537-6
6-1415538-0
AgSnO2
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
5 VDC
+ 0.2 μm Au
6 VDC
9 VDC
12 VDC
15 VDC
18 VDC
21 VDC
24 VDC
36 VDC
40 VDC
48 VDC
60 VDC
85 VDC
110 VDC
3
Datasheet
Rev. FC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
‘Schrack’ section.
Issued 2006/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
only to be used together
with the 'Definitions' at
schrackrelays.com in the
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.
General Purpose Relays
Safety Relay SR6 (Continued)
1200 mW version
Product key
SR6B4012
SR6B4018
SR6A4021
SR6B4021
SR6A4024
SR6B4024
SR6C4024
SR6B4048
SR6A4110
SR6B4110
SR6C4110
Prior product key Contact configuration Contact material
Coil
Part number
0-1393260-4
0-1393260-5
3-1415018-1
0-1393260-6
0-1415015-1
0-1393260-7
0-1415017-1
1-1393260-0
9-1415018-1
1-1393260-3
5-1415019-1
V23050-A1012-A542
V23050-A1018-A542
V23050-A1021-A533
V23050-A1021-A542
V23050-A1024-A533
V23050-A1024-A542
V23050-A1024-A551
V23050-A1048-A542
V23050-A1110-A533
V23050-A1110-A542
V23050-A1110-A551
AgSnO2
4 NO + 2 NC
12 VDC
18 VDC
21 VDC
3 NO + 3 NC
4 NO + 2 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
4 NO + 2 NC
3 NO + 3 NC
4 NO + 2 NC
5 NO + 1 NC
24 VDC
48 VDC
110 VDC
4
Datasheet
Rev. FC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
‘Schrack’ section.
Issued 2006/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
only to be used together
with the 'Definitions' at
schrackrelays.com in the
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.
SR6C6K60 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
SR6C6K85 | TE | General Purpose Relays | 获取价格 | |
SR6C6L10 | TE | General Purpose Relays | 获取价格 | |
SR6D4012 | TE | Rev. EK1 | 获取价格 | |
SR6D4018 | TE | Rev. EK1 | 获取价格 | |
SR6D4021 | TE | Rev. EK1 | 获取价格 | |
SR6D4024 | TE | Rev. EK1 | 获取价格 | |
SR6D4040 | TE | Rev. EK1 | 获取价格 | |
SR6D4110 | TE | Rev. EK1 | 获取价格 | |
SR6DM | TE | Rev. EK1 | 获取价格 | |
SR6DM_09 | TE | Safety Relay SR6 D/M | 获取价格 |
SR6C6K60 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6