2-1393254-7 [MACOM]

Magnetic Hydraulic P&B Circuit Breakers; 电磁液压P&B断路器
2-1393254-7
型号: 2-1393254-7
厂家: Tyco Electronics    Tyco Electronics
描述:

Magnetic Hydraulic P&B Circuit Breakers
电磁液压P&B断路器

断路器
文件: 总7页 (文件大小:2238K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
W6/W9 series  
Magnetic Hydraulic  
P&B Circuit Breakers  
Features  
Typical Resistance and Impedance  
• Designed for the international market. UL Recognized (UL1077 and  
UL1500), CSA Accepted and VDE approved.  
• Ratings to 50 amps.  
DC  
50/60 Hz.  
Impedance  
(Ohms)  
Current  
(Amps)  
Resistance  
(Ohms)  
• Heavy duty #10-32 stud connections. (W9)  
• Quick-connect or screw terminals. (W6)  
• Optional 10 amp auxiliary switch.  
0.2  
1.0  
90  
90  
1.2  
1.2  
2.0  
0.28  
0.04  
0.28  
0.04  
• Several delay curve options.  
5.0  
10.0  
20.0  
30.0  
40.0  
50.0  
0.013  
0.004  
0.0027  
0.002  
0.0015  
0.013  
0.005  
0.004  
0.002  
0.0015  
• Choice of toggle or rocker actuator per pole or per unit (W6).  
• Optional relay/remote trip pole available.  
Trip-free operation.  
Agency Approvals  
UL: Recognized as Supplementary Protector under UL 1077. Available  
models meet Ignition Protection requirements in accordance with  
UL1500. File E69543.  
CSA: Accepted as a Supplementary Protector. File LR15734.  
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)  
License No. 73782.  
Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%.  
Mechanical/Environmental Data  
Operating Temperature: -40°C to +85°C.  
Humidity: Meets requirements of Mil-STD-202 method 103.  
Shock: Tested per Mil-STD-202, method 213, test condition C  
(100g @ 6 ms).  
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06"  
(1.52mm) total excursion in 2 planes.  
Users should thoroughly review the technical data before selecting a product part  
number. It is recommended that users also seek out the pertinent approvals files of  
the agencies/laboratories and review them to confirm the product meets the  
requirements for a given application.  
Fungus And Moisture Resistance: Special moisture resistant finish  
applied to all ferrous parts.  
Electrical Data  
Plastic parts are made of inherently  
fungus resistant material.  
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.  
Calibration: Breakers will hold 100% of rated current.  
Breakers may trip between 101% and 124% of rated load  
(134% for AC/DC units).  
Breakers must trip at 125% of rated load and above (135%  
for AC/DC units).  
Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V.  
Insulation Resistance: 100 Megohms at 500VDC.  
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.  
Units tested at six cycles per minute, 1 second on and 9  
seconds off at 25°C ambient.  
Marking: International “1” and “0” symbols are marked on the toggle for  
both W6 and W9. W9 units have “ON” and “OFF” molded into  
the area at the base of the toggle. On a special order basis,  
graphics can be imprinted on the rockers of rocker actuated W6  
units. VDE approved versions of rocker actuated W6 breakers  
have their rockers imprinted with “1” and “0.”  
Mounting: Units are mounted with two #6-32 screws from the front of  
the panel. Metric models for use with M3 x 0.5 screws are  
available. To maintain published performance specifications,  
units should not be mounted more than 90° from their normal  
upright position.  
Relay Trip Coil: (Ratings applicable to all W6 models with this option)  
24 to 277VAC, 150mA minimum available current;  
6 to 48VDC, 300mA minimum available current.  
Weight: Approximately 2.5 ounces per pole.  
Approvals and Ratings Table 1  
W6 Series  
UL1077/CSA (All Circuit Functions)  
W6 or W9 Series VDE (Circuit Function X)  
Current  
Rating  
(Amps)  
Interrupting  
Capacity  
(Amps)  
Current  
Rating  
(Amps)  
Interrupting  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Phase  
Maximum  
Voltage  
Frequency  
(Hz)  
Phase  
65  
277  
DC  
-
0.2 - 50  
0.2 - 20  
21 - 50  
0.2 - 20  
2,000  
5,000  
2,500  
5,000  
65  
250  
DC  
-
1
0.2-50  
0.2-30  
31-50  
0.2-30  
2,000  
5,000  
2,000  
5,000  
50/60  
50/60  
50/60  
1
1
50/60  
50/60  
50/60  
277  
250  
1
277/480  
3Ø-Wye  
415/240  
3Ø  
W9 Series  
UL1077/CSA (All Circuit Functions)  
W6 or W9 Series UL1500 (Circuit Function X)  
Current  
Rating  
(Amps)  
Interrupting  
Capacity  
(Amps)  
Current  
Interrupting  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Phase  
Maximum  
Voltage  
Frequency  
(Hz)  
Phase  
Rating  
(Amps)  
65  
277  
277/480  
DC  
50/60  
50/60  
-
1
0.2 - 50  
0.2 - 50  
0.2 - 20  
2,000  
5,000  
5,000  
48  
125/250  
250  
DC  
50/60  
50/60  
-
1
0.2 - 50  
0.2 - 50  
0.2 - 50  
3,000  
1,000  
1,000  
3Ø-Wye  
3Ø-Wye  
Auxiliary Switch Ratings Table 2  
UL/CSA  
Switch  
Number  
Voltage  
50/60 Hz.  
Current  
(Amps)  
Terminals  
WxTxL  
A
125  
10  
.093 x .020 x .250  
(2.36 x .51 x 6.40)  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
1
UK: 44-8706-080208  
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Time vs. Current Trip Curves For W6 Series and W9 Series  
AC 50/60 Hz.  
DC & 50/60 Hz.  
400 Hz.  
10,000  
CURVE 0 INSTANTANEOUS  
CURVE 2 STANDARD DELAY 50/60 Hz.  
CURVE 3 SHORT DELAY 50/60 Hz.  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
TRIPTIMES  
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
1000  
100  
10  
125%  
150%  
200%  
400%  
600%  
800%  
100 ms max.  
55 ms max.  
30 ms max.  
15 ms max.  
12 ms max.  
12 ms max.  
MayTrip  
125%  
200%  
400%  
600%  
800%  
1000%  
10 - 150  
2.2 - 20  
.2 - 2  
.03 - .75  
.007 - .15  
.005 - .04  
125%  
200%  
400%  
600%  
800%  
1000%  
1 - 15  
.15 - 1.5  
.03 - .25  
100 ms max.  
30 ms max.  
15 ms max.  
12 ms max.  
12 ms max.  
.007 - .15  
.003 - .08  
.003 - .04  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
MOTOR START / LONG DELAY  
CURVE 13 HIGH INRUSH 50/60 Hz.  
CURVE 12 HIGH INRUSH 50/60 Hz.  
CURVE 10 HIGH INRUSH 50/60 Hz. AC  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
(SEC.)  
125%  
200%  
400%  
600%  
800%  
1000%  
40 - 500  
9 - 100  
2 - 20  
125%  
200%  
400%  
600%  
800%  
1000%  
10 - 150  
3 - 25  
.5 - 2.5  
.15 - 1  
.015 - .7  
.009 - .35  
125%  
200%  
400%  
600%  
800%  
1000%  
.8 - 30  
.15 - 2.5  
.03 - .3  
.02 - .15  
.009 - .12  
.009 - .09  
.8 - 10  
.1 - 4.5  
.009 - 2  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
DC  
CURVE 2 STANDARD DELAY DC  
CURVE 3 SHORT DELAY DC  
CURVE 53 DC HIGH INRUSH  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
OVERLOAD TRIPTIMES  
(SEC.)  
OVERLOAD TRIPTIMES  
(SEC.)  
(SEC.)  
125%  
200%  
400%  
600%  
800%  
1000%  
80 - 700  
15 - 150  
2 - 20  
125%  
200%  
400%  
600%  
800%  
1000%  
2 - 55  
.60 - 8  
125%  
200%  
400%  
600%  
800%  
1000%  
.6 - 7  
.16 - 1.5  
.70 - 10  
.10 - 3  
.1 - 1.5  
.03 - .25  
.01 - .13  
.004 - .05  
.003 - .015  
.02 - .5  
.01 - .1  
.004 - .05  
.004 - .025  
1
1
1
.1  
.1  
.1  
.01  
.01  
.01  
.001  
0
.001  
0
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
125 150  
125 150  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
LOAD CURRENT AS A PERCENT  
OF BREAKER RATING  
OF BREAKER RATING  
OF BREAKER RATING  
AC/DC  
CURVE 34 DC, 50/60 Hz. STANDARD DELAY  
10,000  
1000  
100  
10  
OVERLOAD TRIPTIMES  
(SEC.)  
135%  
200%  
400%  
600%  
800%  
1000%  
1 - 90  
.60 - 20  
.095 - 2  
.02 - .95  
.002 - .45  
.002 - .09  
1
.1  
.01  
.001  
0
100 200 300 400 500 600 700 800 900 1000 1100 1200  
125 150  
LOAD CURRENT AS A PERCENT  
135  
OF BREAKER RATING  
Note:  
For instantaneous curves for all voltages refer to Curve 0 Instantaneous under the AC 50/60 Hz. heading.  
Pulse Tolerance Specifications  
Pulse tolerance is defined as a single pulse of a half sine  
wave (1/2 cycle or 8 milliseconds) that will not trip the  
breaker. An inertia wheel for increased pulse tolerance is  
available by specifying “P” after the time delay curve  
number in the ordering information. The table at right lists  
pulse tolerance values of standard and inertia delay models.  
Pulse Tolerance Value  
Inertia  
Time  
Delay  
Curve  
Voltage  
Standard  
Delay  
2
3
10  
12  
13  
7.5  
6
18  
18  
30  
30  
30  
AC  
50/60 Hz.  
18  
18  
18  
To determine pulse tolerance multiply breaker rating by value in table. For  
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance  
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance  
of 36A (2A x 18).  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
USA: 1-800-522-6752  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
UK: 44-8706-080208  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
2
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Ordering Information  
W6 Series  
Typical Part No. >  
W 67- X  
2
Q
1
2- 20  
1. Circuit Breaker Mounting:  
W = #6-32 mounting threads.  
M = M3.0 x 0.5 mounting threads.  
2. Number of Poles:  
67 = Single pole  
68 = Two pole  
69 = Three pole  
70 = Four pole  
3. Circuit Function: (Only X is VDE approved)  
A = Series trip with auxiliary switch (.093” QC)  
X = Series trip  
D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole (4 pole package) max., must  
specify #10-32 screw terminals below, but relay trip pole will be equipped with .250” QC term. only, not UL),  
relay trip pole will be on the right side of the breaker when viewed from the front.  
4. Actuator:  
One actuator per pole  
1 = Black toggle  
2 = White toggle  
3 = Black rocker  
4 = White rocker  
5 = Red rocker  
6 = Grey rocker  
9 = Red toggle  
One actuator per unit  
7 = Black toggle  
8 = White toggle  
J = Black rocker  
5. Termination:  
Q = .250” QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE]  
S = #8-32 screw [30A Max.]  
T = #10-32 screw [50A Max.]  
U = #8-32 screw, nickel plated, bent inward 30° [30A Max.]  
V = #10-32 screw, nickel plated, bent inward 30° [50A Max.]  
Notes: #10-32 termination must be used for all ratings of greater than 30 amps.  
#10-32 termination must be specified for circuit function D, but relay trip pole will be equipped with .250” QC.  
6. Maximum Line Voltage: (See Table 1 for current ranges)  
UL/CSA 1 = 277VAC, 50/60 Hz.  
TYPES  
2 = 277/480VAC, 50/60 Hz. [20A Max.] (Requires insulating barriers, see outline dimension drawing)  
5 = 65VDC  
7 = AC/DC 277VAC, 50/60 Hz. or 65VDC  
(Time delay curve 34 must be specified.)  
8 = AC/DC 120VAC, 120/240VAC, 48VDC  
(Agency Approval M [UL1500] and time delay curve 34 must be specified.)  
VDE  
TYPES  
1 = 250VAC, 415/240VAC  
5 = 65VDC  
7 = AC/DC 250VAC, 415/240VAC, 65VDC  
(Time delay curve 34 must be specified.)  
7. Time Delay Curve:  
0 = Instantaneous  
2 = Standard delay  
3 = Short delay  
10 = AC high inrush motor start / long delay  
12 = AC high inrush version of #2  
13 = AC high inrush version of #3  
53 = DC high inrush  
34 = Combination AC/DC standard delay  
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve.  
See delay curve section for availability and details.  
8. Amp Rating:  
0.20  
0.25  
0.50  
0.75  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
5.0  
6.0  
7.0  
7.5  
8.0  
9.0  
10.0  
11.0  
12.0  
15.0  
20.0  
25.0  
30.0  
35.0  
40.0  
45.0  
50.0  
Consult factory for  
other values.  
9. Agency Approval:  
Blank = UL1077/CSA breaker  
V = VDE approved breaker without auxiliary switch  
M = UL1077/UL1500 ignition protected breaker  
Authorized distributors are more likely to stock the following items.  
W67-A2Q12-5  
W67-A2Q12-10  
W67-X2Q10-3  
W67-X2Q10-5  
W67-X2Q12-2  
W67-X2Q12-3  
W67-X2Q12-5  
W67-X2Q12-7  
W67-X2Q12-10  
W67-X2Q12-15  
W67-X2Q12-20  
W67-X2Q12-30  
W67-X2Q13-1  
W67-X2Q13-2  
W67-X2Q13-3  
W67-X2Q13-10  
W67-X2Q13-15  
W67-X2Q13-20  
W67-X2Q13-25  
W67-X2Q13-30  
W67-X2Q50-5  
W67-X2Q50-10  
W67-X2Q52-5  
W67-X2Q52-10  
W67-X2Q52-15  
W68-X2Q12-5  
W68-X2Q12-7  
W68-X2Q12-10  
W68-X2Q12-15  
W68-X2Q12-20  
W68-X2Q12-25  
W68-X2Q12-30  
W69-X2Q12-15  
W69-X2Q12-20  
W69-X2Q12-25  
W69-X2Q12-30  
W69-X2Q110-20  
W69-X2Q110-30  
W67-X2Q52-20  
W67-X2Q52-30  
W67-X2Q110-15  
W67-X2Q110-20  
W68-X2Q12-3  
W68-X2Q13-15  
W68-X2Q110-10  
W68-X2Q110-20  
W69-X2Q12-5  
W69-X2Q12-10  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
3
UK: 44-8706-080208  
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Ordering Information  
W9 Series  
Typical Part No. >  
1
W
1
2- 20  
91-  
X
1. Circuit Breaker Mounting:  
W = #6-32 mounting threads.  
M = M3.0 x 0.5 mounting threads.  
2. Number of Poles:  
91 = Single pole  
92 = Two pole  
93 = Three pole  
94 = Four pole  
3. Circuit Function: (Only X is VDE approved)  
A = Series trip with auxiliary switch (.093” QC)  
X = Series trip  
D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole max., not UL)  
4. Actuator:  
One actuator per pole:  
1 = Black toggle  
2 = White toggle  
5. Maximum Line Voltage: (See Table 1 for current ranges)  
UL/CSA 1 = 277VAC, 50/60 Hz.  
TYPES  
2 = 277/480VAC, 50/60 Hz. [20A Max.]  
5 = 65VDC  
7 = AC/DC 277VAC, 50/60 Hz. or 65VDC  
(Time delay curve 34 must be specified.)  
8 = AC/DC 120VAC, 120/240VAC, 48VDC  
(Agency Approval M [UL1500] and time delay curve 34 must be specified.)  
VDE  
TYPES  
1 = 250VAC, 415/240VAC  
5 = 65VDC  
7 = AC/DC 250VAC, 415/240VAC, 65VDC  
(Time delay curve 34 must be specified.)  
6. Time Delay Curve:  
0 = Instantaneous  
2 = Standard delay  
3 = Short delay  
10 = AC high inrush motor start / long delay  
12 = AC high inrush version of #2  
13 = AC high inrush version of #3  
53 = DC high inrush  
34 = Combination AC/DC standard delay  
Notes:  
Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve.  
See delay curve section for availability and details.  
7. Amp Rating:  
0.20  
0.25  
0.50  
0.75  
2.0  
2.5  
3.0  
3.5  
4.0  
5.0  
6.0  
7.0  
7.5  
8.0  
9.0  
10.0  
11.0  
12.0  
15.0  
20.0  
25.0  
30.0  
35.0  
40.0  
45.0  
50.0  
1.0  
1.5  
Consult factory for other values  
8. Agency Approval:  
Blank = UL1077/CSA approved breaker  
V = VDE approved breaker without auxiliary switch  
M = UL1077/UL1500 ignition protected breaker  
Authorized distributors are more likely to stock the following items.  
W91-X112-1  
W91-X112-2  
W91-X112-3  
W91-X112-5  
W91-X112-7  
W91-X112-10  
W91-X112-15  
W91-X112-20  
W91-X112-40  
W91-X112-50  
W91-X113-5  
W91-X113-10  
W91-X113-15  
W91-X150-5  
W91-X152-10  
W91-X152-15  
W91-X152-20  
W91-X152-30  
W91-X152-40  
W91-X152-50  
W91-X1110-20  
W92-X112-1  
W92-X112-2  
W92-X112-3  
W92-X112-5  
W92-X112-7  
W92-X112-10  
W92-X112-15  
W92-X112-20  
W92-X112-25  
W92-X112-30  
W92-X112-40  
W92-X112-50  
W92-X113-15  
W92-X113-20  
W92-X1110-20  
W92-X1110-30  
W93-X112-5  
W93-X112-10  
W93-X112-15  
W93-X112-20  
W93-X112-25  
W93-X112-30  
W93-X112-40  
W93-X112-50  
W93-X1110-20  
W93-X1110-30  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
4
UK: 44-8706-080208  
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Outline Dimensions - Toggle Actuator Models  
W6 Series  
Panel Mounting Cutout  
2.043  
.750  
(19.05)  
.66  
(16.8)  
(51.89)  
Ø .625 +.010  
-.000  
.235  
(5.97)  
1.640  
(41.66)  
.245  
(6.22)  
15.88 +0.25  
-0.00  
1 PER POLE  
(
)
ON  
29°  
A
B
LINE  
1.660  
(42.16)  
1.048  
(26.62)  
1.520  
(38.61)  
30°  
OFF  
Ø .156  
(3.96)  
LOAD  
[2 PLACES PER POLE]  
W6 Series – One Actuator Per Pole  
1 Pole  
2 Pole  
3 Pole  
4 Pole  
Ø .590  
(15.00)  
.750  
(19.05)  
1.500  
(38.10)  
2.250  
(57.15)  
3.000  
(76.20)  
1.660  
(42.16)  
2.000  
(50.80)  
1.05  
(26.67)  
1.22  
(31.00)  
6.32TH'D. .14 (3.56) DP.TYP.  
M3 X 0.5 OPTIONAL  
Note:  
Multi-pole models furnished with separate handle tie hardware.  
W6 Series – One Actuator Per Unit  
1 Pole  
2 Pole  
3 Pole  
4 Pole  
Ø .590  
(15.00)  
.750  
(19.05)  
2.250  
(57.15)  
1.500  
(38.10)  
3.000  
(76.20)  
1.660  
2.000  
(50.80)  
(42.16)  
1.05  
(26.67)  
1.22  
(31.00)  
6.32TH'D. .14 (3.56) DP.TYP.  
M3 X 0.5 OPTIONAL  
Note: 4-pole models furnished with separate  
handle tie hardware.  
480V Model with Barriers  
Model with Aux. Relay Trip Pole  
2.778  
(70.56)  
2.250  
(57.15)  
.269  
(6.83)  
Note: W68 -D model shown. Note that the  
auxiliary relay trip pole is on the right.  
#10-32 screw terminals must be  
specified with this option; however,  
the terminals on the relay trip pole  
are 0.250” quick connects.  
2.530  
(64.26)  
The relay pole is self-opening, so the  
trip current can remain energized  
indefinitely.  
.266  
(6.76)  
Note: 3-pole model shown.  
Termination Options  
VDE Models  
W/Screw Terminals  
UL/CSA Models  
W/Screw Terminals  
UL/CSA/VDE Models  
W/Aux. Switch  
UL/CSA Models  
W/Terminals Bent 30°  
Notes:  
1. Terminal protrusion dimensions are  
referenced from back of mounting panel.  
2. Main terminals are male quick connect  
type .250 (6.35) wide x .031 (.79) thick x  
.377 (9.58) long. Optional 8-32 x .250  
(6.35) or 10-32 x .250 (6.35) screw type.  
3. Panel mounting cutout detail mtg. detail  
tol.: .005 (.13) unless noted. Add  
additional cutouts to correspond to  
number of poles. Outline drawing  
tolerance .015 (.38) unless noted.  
.235  
2.032  
2.380  
(60.45)  
(5.97)  
(51.61)  
LINE  
.416  
LINE  
LINE  
LINE  
A
A
A
(10.56)  
C
1.058  
(26.97)  
.827  
(21.00)  
NO  
NC  
1.520  
(38.61)  
B
B
B
LOAD  
LOAD  
LOAD  
LOAD  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
5
UK: 44-8706-080208  
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Outline Dimensions - Optional Toggle Guards  
W6 Series  
1.375 INSIDE  
(34.92)  
.625 INSIDE  
(15.88)  
2.185 INSIDE  
(55.50)  
1.093  
.03  
(.76)  
.313  
(7.95)  
(27.76)  
.313  
(7.95)  
.75  
(19.05)  
.75  
.75  
(19.05)  
(19.05)  
.2 x  
R1.0  
(25.4)  
.47  
.78  
(19.8)  
(11.94)  
.95  
.17  
(4.32)  
(24.1)  
.17 REF.  
(4.32)  
.08  
(2.03)  
.625  
(15.88)  
2.00  
(50.8)  
1.66  
(42.16)  
2 x  
.27 DIA.  
(6.86)  
.44  
(11.18)  
84-004 toggle guard shown  
with W67 series circuit  
breaker mounted in a panel.  
.53  
(13.46)  
2 x .16 DIA.  
(4.06)  
.20  
(5.08)  
4 x .16 DIA.  
(4.06)  
6 x .16 DIA.  
(4.06)  
84-004  
(For 1 Pole  
Breaker)  
84-005  
(For 2 Pole  
Breaker)  
84-006  
(For 3 Pole  
Breaker)  
Optional toggle guards may be ordered separately for use on W6 toggle actuator models. These guards help to prevent accidental operation and allow the breaker to be  
locked in the “off” position.  
Outline Dimensions - Rocker Actuator Models  
W6 Series  
1 Pole  
2, 3 & 4 Pole, One Actuator Per Pole  
(Shown with optional “ON”  
and “OFF” graphics)  
3.000  
(76.20)  
.750  
(19.05)  
4
2.250  
(57.15)  
POLE  
1.769  
(44.93)  
.774  
(19.65)  
3
1.500  
.375  
(9.53)  
.240  
(6.10)  
POLE  
(38.10)  
.392  
(9.96)  
2 POLE  
.180  
(4.57)  
LOAD  
D
A
.388  
(9.86)  
2.000  
(50.80)  
1.660  
(42.16)  
1.520  
(38.61)  
ON  
2.600  
(66.04)  
OFF  
1.30  
(33.0)  
LINE  
.375  
(9.53)  
TAPPED FOR #6-32  
M3 X 0.5 OPTIONAL  
.750  
(19.05)  
.750  
(19.05)  
2.435  
(61.85)  
.750  
(19.05)  
2, 3 & 4 Pole, One Actuator Per Unit  
1.500  
(38.10)  
2.250  
(57.15)  
3.000  
(76.20)  
.388  
(9.86)  
2.000  
(50.80)  
1.660  
(42.16)  
1.660  
(42.16)  
2.600  
(66.04)  
.375  
(9.53)  
.375  
(9.53)  
.750  
.750  
(19.05)  
.750  
(19.05)  
.375  
(9.53)  
(19.05)  
TAPPED FOR #6-32  
.750  
.750  
(19.05)  
.750  
(19.05)  
M3 X 0.5 OPTIONAL  
(19.05)  
Panel Mounting Cutout  
VDE Rocker Marking  
.750  
(19.05)  
.750  
(19.05)  
.205  
(5.21)  
.375  
(9.53)  
.750  
(19.05)  
1.250  
(31.75)  
I
1.660  
(42.16)  
O
Notes:  
1. Outline drawing tolerance .015 (.38) unless  
noted. Dimensions in brackets ( ) are in  
millimeters.  
2. Mounting Detail Tol.: .005 (.13) unless noted  
.750  
(19.05)  
1 POLE  
2 POLE  
3 POLE  
4 POLE  
1.500  
(38.10)  
Ø .156  
(3.96)  
TYP. 2  
2.250  
(57.15)  
PER POLE  
3.000  
(76.20)  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
6
UK: 44-8706-080208  
Catalog 1308242  
Issued 3-03 (PDF Rev. 03-10)  
Outline Dimensions  
W9 Series  
Series Trip Model  
Series Trip Model  
.060  
.750  
(19.05)  
.375  
(9.53)  
.750  
(19.05)  
.750  
(19.05)  
1.845  
(1.52)  
(46.86)  
.398  
(10.11)  
.375  
(9.53)  
.375  
(9.52)  
.313  
(7.95)  
.281  
(7.14)  
.750  
(19.05)  
1.15  
(29.21)  
LINE  
.060  
(1.52)  
ON  
ON ON  
OFFOFF  
ON ON ON ON ON ON ON ON  
OFFOFF OFFOFF OFFOFF OFFOFF  
Note:  
.218  
(5.54)  
2.065  
(52.45)  
29°  
30°  
1. Top mounted plate  
(shown with broken  
line) is present only on  
UL1500 models.  
1.438  
(36.53)  
1.940  
(49.28)  
2.50  
(63.5)  
OFF  
LOAD  
#10-32  
STUD  
2 POLE  
1.500  
(38.10)  
.14  
(3.56)  
1 POLE  
2.10  
(53.34)  
TERMINATION  
2.250  
(57.15)  
3POLE  
TAPPED #6-32 X .16 (4.06)  
DEEP  
M3 X 0.5 OPTIONAL  
2.50  
(64.00)  
.74  
(18.8)  
3.000  
4 POLE  
(76.20)  
Series Trip Model  
Panel Mounting Cutout Detail  
With Common Enclosed Auxiliary Switch  
.750  
(19.05)  
.750  
(19.05)  
Notes:  
.732  
(18.59)  
.281  
2.46  
.750  
(19.05)  
.385  
1. Terminal protrusion  
dimensions are referenced  
from the back of the  
mounting panel.  
'A' STYLE  
(7.14)  
(9.78)  
(62.48)  
.907  
(23.04)  
LINE  
2. Mounting detail tolerance  
.005 (13) unless noted.  
3. Outline drawing tolerance  
.015 (.38) unless noted.  
Dimensions in brackets ( )  
are in millimeters.  
1.450  
C
NO  
(36.83)  
2.065  
(52.45)  
1.940  
(49.28)  
NC  
LOAD  
.76  
(19.3)  
2X Ø .156  
(3.96)  
PER POLE  
1 POLE  
1.52  
(38.6)  
2 POLE  
3 POLE  
4 POLE  
2.50  
(64.00)  
2.28  
(57.9)  
3.04  
(77.2)  
Disclaimer:  
While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this  
document, Tyco Electronics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any representation or offer any  
guarantee that such information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information at any  
time. Tyco Electronics expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied  
warranties of merchantability or fitness for a particular purpose. Tyco Electronics‘ only obligations are those stated in Tyco Electronics’ Standard Terms and  
Conditions of Sale. Tyco Electronics will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including,  
but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate the suitability of a product for a certain  
purpose and test each product for its intended application.  
In case of any potential ambiguities or questions, please don’t hesitate to contact us for clarification.  
© 2010 by Tyco Electronics Corporation. All Rights Reserved.  
P&B, Potter & Brumfield, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors.  
Revised 03-10  
www.tycoelectronics.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and  
availability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
7
UK: 44-8706-080208  

相关型号:

2-1393254-8

Magnetic Hydraulic P&B Circuit Breakers
MACOM

2-1393254-9

Magnetic Hydraulic P&B Circuit Breakers
MACOM

2-1393255-2

Magnetic Hydraulic P&B Circuit Breakers
MACOM

2-1393255-3

Magnetic Hydraulic P&B Circuit Breakers
MACOM

2-1393258-0

Force Guided Relay SR2M
MACOM

2-1393258-0

2 pole relay with force guided contacts according to EN 50205
TE

2-1393258-1

2 pole relay with force guided contacts according to EN 50205
TE

2-1393258-2

2 pole relay with force guided contacts according to EN 50205
TE

2-1393258-3

2 pole relay with force guided contacts according to EN 50205
TE

2-1393302-2

Power Relay F4 / VF4 Plug-In Relays Mini ISO relays
MACOM

2-1393302-3

Power Relay F4 / VF4 Plug-In Relays Mini ISO relays
MACOM

2-1393305-1

Power Relay F4 / VF4 Plug-In Relays Mini ISO relays
MACOM