Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
W6/W9 series
Magnetic Hydraulic
P&B Circuit Breakers
Features
Typical Resistance and Impedance
• Designed for the international market. UL Recognized (UL1077 and
UL1500), CSA Accepted and VDE approved.
• Ratings to 50 amps.
DC
50/60 Hz.
Impedance
(Ohms)
Current
(Amps)
Resistance
(Ohms)
• Heavy duty #10-32 stud connections. (W9)
• Quick-connect or screw terminals. (W6)
• Optional 10 amp auxiliary switch.
0.2
1.0
90
90
1.2
1.2
2.0
0.28
0.04
0.28
0.04
• Several delay curve options.
5.0
10.0
20.0
30.0
40.0
50.0
0.013
0.004
0.0027
0.002
0.0015
0.013
0.005
0.004
0.002
0.0015
• Choice of toggle or rocker actuator per pole or per unit (W6).
• Optional relay/remote trip pole available.
• Trip-free operation.
Agency Approvals
UL: Recognized as Supplementary Protector under UL 1077. Available
models meet Ignition Protection requirements in accordance with
UL1500. File E69543.
CSA: Accepted as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782.
Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms).
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06"
(1.52mm) total excursion in 2 planes.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to confirm the product meets the
requirements for a given application.
Fungus And Moisture Resistance: Special moisture resistant finish
applied to all ferrous parts.
Electrical Data
Plastic parts are made of inherently
fungus resistant material.
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Calibration: Breakers will hold 100% of rated current.
Breakers may trip between 101% and 124% of rated load
(134% for AC/DC units).
Breakers must trip at 125% of rated load and above (135%
for AC/DC units).
Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Marking: International “1” and “0” symbols are marked on the toggle for
both W6 and W9. W9 units have “ON” and “OFF” molded into
the area at the base of the toggle. On a special order basis,
graphics can be imprinted on the rockers of rocker actuated W6
units. VDE approved versions of rocker actuated W6 breakers
have their rockers imprinted with “1” and “0.”
Mounting: Units are mounted with two #6-32 screws from the front of
the panel. Metric models for use with M3 x 0.5 screws are
available. To maintain published performance specifications,
units should not be mounted more than 90° from their normal
upright position.
Relay Trip Coil: (Ratings applicable to all W6 models with this option)
24 to 277VAC, 150mA minimum available current;
6 to 48VDC, 300mA minimum available current.
Weight: Approximately 2.5 ounces per pole.
Approvals and Ratings Table 1
W6 Series
UL1077/CSA (All Circuit Functions)
W6 or W9 Series VDE (Circuit Function X)
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
Maximum
Voltage
Frequency
(Hz)
Phase
Maximum
Voltage
Frequency
(Hz)
Phase
65
277
DC
-
0.2 - 50
0.2 - 20
21 - 50
0.2 - 20
2,000
5,000
2,500
5,000
65
250
DC
-
1
0.2-50
0.2-30
31-50
0.2-30
2,000
5,000
2,000
5,000
50/60
50/60
50/60
1
1
50/60
50/60
50/60
277
250
1
277/480
3Ø-Wye
415/240
3Ø
W9 Series
UL1077/CSA (All Circuit Functions)
W6 or W9 Series UL1500 (Circuit Function X)
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
Current
Interrupting
Capacity
(Amps)
Maximum
Voltage
Frequency
(Hz)
Phase
Maximum
Voltage
Frequency
(Hz)
Phase
Rating
(Amps)
65
277
277/480
DC
50/60
50/60
-
1
0.2 - 50
0.2 - 50
0.2 - 20
2,000
5,000
5,000
48
125/250
250
DC
50/60
50/60
-
1
0.2 - 50
0.2 - 50
0.2 - 50
3,000
1,000
1,000
3Ø-Wye
3Ø-Wye
Auxiliary Switch Ratings Table 2
UL/CSA
Switch
Number
Voltage
50/60 Hz.
Current
(Amps)
Terminals
WxTxL
A
125
10
.093 x .020 x .250
(2.36 x .51 x 6.40)
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
1
UK: 44-8706-080208
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Time vs. Current Trip Curves For W6 Series and W9 Series
AC 50/60 Hz.
DC & 50/60 Hz.
400 Hz.
10,000
CURVE 0 INSTANTANEOUS
CURVE 2 STANDARD DELAY 50/60 Hz.
CURVE 3 SHORT DELAY 50/60 Hz.
10,000
1000
100
10
10,000
1000
100
10
TRIPTIMES
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
1000
100
10
125%
150%
200%
400%
600%
800%
100 ms max.
55 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
MayTrip
125%
200%
400%
600%
800%
1000%
10 - 150
2.2 - 20
.2 - 2
.03 - .75
.007 - .15
.005 - .04
125%
200%
400%
600%
800%
1000%
1 - 15
.15 - 1.5
.03 - .25
100 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
.007 - .15
.003 - .08
.003 - .04
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
MOTOR START / LONG DELAY
CURVE 13 HIGH INRUSH 50/60 Hz.
CURVE 12 HIGH INRUSH 50/60 Hz.
CURVE 10 HIGH INRUSH 50/60 Hz. AC
10,000
1000
100
10
10,000
1000
100
10
10,000
1000
100
10
OVERLOAD TRIPTIMES
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
(SEC.)
125%
200%
400%
600%
800%
1000%
40 - 500
9 - 100
2 - 20
125%
200%
400%
600%
800%
1000%
10 - 150
3 - 25
.5 - 2.5
.15 - 1
.015 - .7
.009 - .35
125%
200%
400%
600%
800%
1000%
.8 - 30
.15 - 2.5
.03 - .3
.02 - .15
.009 - .12
.009 - .09
.8 - 10
.1 - 4.5
.009 - 2
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
DC
CURVE 2 STANDARD DELAY DC
CURVE 3 SHORT DELAY DC
CURVE 53 DC HIGH INRUSH
10,000
1000
100
10
10,000
1000
100
10
10,000
1000
100
10
OVERLOAD TRIPTIMES
OVERLOAD TRIPTIMES
(SEC.)
OVERLOAD TRIPTIMES
(SEC.)
(SEC.)
125%
200%
400%
600%
800%
1000%
80 - 700
15 - 150
2 - 20
125%
200%
400%
600%
800%
1000%
2 - 55
.60 - 8
125%
200%
400%
600%
800%
1000%
.6 - 7
.16 - 1.5
.70 - 10
.10 - 3
.1 - 1.5
.03 - .25
.01 - .13
.004 - .05
.003 - .015
.02 - .5
.01 - .1
.004 - .05
.004 - .025
1
1
1
.1
.1
.1
.01
.01
.01
.001
0
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
125 150
125 150
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OF BREAKER RATING
OF BREAKER RATING
AC/DC
CURVE 34 DC, 50/60 Hz. STANDARD DELAY
10,000
1000
100
10
OVERLOAD TRIPTIMES
(SEC.)
135%
200%
400%
600%
800%
1000%
1 - 90
.60 - 20
.095 - 2
.02 - .95
.002 - .45
.002 - .09
1
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
135
OF BREAKER RATING
Note:
For instantaneous curves for all voltages refer to Curve 0 Instantaneous under the AC 50/60 Hz. heading.
Pulse Tolerance Specifications
Pulse tolerance is defined as a single pulse of a half sine
wave (1/2 cycle or 8 milliseconds) that will not trip the
breaker. An inertia wheel for increased pulse tolerance is
available by specifying “P” after the time delay curve
number in the ordering information. The table at right lists
pulse tolerance values of standard and inertia delay models.
Pulse Tolerance Value
Inertia
Time
Delay
Curve
Voltage
Standard
Delay
2
3
10
12
13
7.5
6
18
18
30
30
30
AC
50/60 Hz.
18
18
18
To determine pulse tolerance multiply breaker rating by value in table. For
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance
of 36A (2A x 18).
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
USA: 1-800-522-6752
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080208
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
2
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Ordering Information
W6 Series
Typical Part No. >
W 67- X
2
Q
1
2- 20
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
2. Number of Poles:
67 = Single pole
68 = Two pole
69 = Three pole
70 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole (4 pole package) max., must
specify #10-32 screw terminals below, but relay trip pole will be equipped with .250” QC term. only, not UL),
relay trip pole will be on the right side of the breaker when viewed from the front.
4. Actuator:
One actuator per pole
1 = Black toggle
2 = White toggle
3 = Black rocker
4 = White rocker
5 = Red rocker
6 = Grey rocker
9 = Red toggle
One actuator per unit
7 = Black toggle
8 = White toggle
J = Black rocker
5. Termination:
Q = .250” QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE]
S = #8-32 screw [30A Max.]
T = #10-32 screw [50A Max.]
U = #8-32 screw, nickel plated, bent inward 30° [30A Max.]
V = #10-32 screw, nickel plated, bent inward 30° [50A Max.]
Notes: #10-32 termination must be used for all ratings of greater than 30 amps.
#10-32 termination must be specified for circuit function D, but relay trip pole will be equipped with .250” QC.
6. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
TYPES
2 = 277/480VAC, 50/60 Hz. [20A Max.] (Requires insulating barriers, see outline dimension drawing)
5 = 65VDC
7 = AC/DC 277VAC, 50/60 Hz. or 65VDC
(Time delay curve 34 must be specified.)
8 = AC/DC 120VAC, 120/240VAC, 48VDC
(Agency Approval M [UL1500] and time delay curve 34 must be specified.)
VDE
TYPES
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Time delay curve 34 must be specified.)
7. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
10 = AC high inrush motor start / long delay
12 = AC high inrush version of #2
13 = AC high inrush version of #3
53 = DC high inrush
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve.
See delay curve section for availability and details.
8. Amp Rating:
0.20
0.25
0.50
0.75
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
7.5
8.0
9.0
10.0
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for
other values.
9. Agency Approval:
Blank = UL1077/CSA breaker
V = VDE approved breaker without auxiliary switch
M = UL1077/UL1500 ignition protected breaker
Authorized distributors are more likely to stock the following items.
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
W67-X2Q52-15
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
3
UK: 44-8706-080208
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Ordering Information
W9 Series
Typical Part No. >
1
W
1
2- 20
91-
X
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
2. Number of Poles:
91 = Single pole
92 = Two pole
93 = Three pole
94 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
D = Series trip with auxiliary relay trip pole (requires extra pole package, 3 pole max., not UL)
4. Actuator:
One actuator per pole:
1 = Black toggle
2 = White toggle
5. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
TYPES
2 = 277/480VAC, 50/60 Hz. [20A Max.]
5 = 65VDC
7 = AC/DC 277VAC, 50/60 Hz. or 65VDC
(Time delay curve 34 must be specified.)
8 = AC/DC 120VAC, 120/240VAC, 48VDC
(Agency Approval M [UL1500] and time delay curve 34 must be specified.)
VDE
TYPES
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Time delay curve 34 must be specified.)
6. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
10 = AC high inrush motor start / long delay
12 = AC high inrush version of #2
13 = AC high inrush version of #3
53 = DC high inrush
34 = Combination AC/DC standard delay
Notes:
Curves may be specified with increased pulse tolerance for 1/2 cycle by adding "P" after curve.
See delay curve section for availability and details.
7. Amp Rating:
0.20
0.25
0.50
0.75
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
7.5
8.0
9.0
10.0
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
1.0
1.5
Consult factory for other values
8. Agency Approval:
Blank = UL1077/CSA approved breaker
V = VDE approved breaker without auxiliary switch
M = UL1077/UL1500 ignition protected breaker
Authorized distributors are more likely to stock the following items.
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
4
UK: 44-8706-080208
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Outline Dimensions - Toggle Actuator Models
W6 Series
Panel Mounting Cutout
2.043
.750
(19.05)
.66
(16.8)
(51.89)
Ø .625 +.010
-.000
.235
(5.97)
1.640
(41.66)
.245
(6.22)
15.88 +0.25
-0.00
1 PER POLE
(
)
ON
29°
A
B
LINE
1.660
(42.16)
1.048
(26.62)
1.520
(38.61)
30°
OFF
Ø .156
(3.96)
LOAD
[2 PLACES PER POLE]
W6 Series – One Actuator Per Pole
1 Pole
2 Pole
3 Pole
4 Pole
Ø .590
(15.00)
.750
(19.05)
1.500
(38.10)
2.250
(57.15)
3.000
(76.20)
1.660
(42.16)
2.000
(50.80)
1.05
(26.67)
1.22
(31.00)
6.32TH'D. .14 (3.56) DP.TYP.
M3 X 0.5 OPTIONAL
Note:
Multi-pole models furnished with separate handle tie hardware.
W6 Series – One Actuator Per Unit
1 Pole
2 Pole
3 Pole
4 Pole
Ø .590
(15.00)
.750
(19.05)
2.250
(57.15)
1.500
(38.10)
3.000
(76.20)
1.660
2.000
(50.80)
(42.16)
1.05
(26.67)
1.22
(31.00)
6.32TH'D. .14 (3.56) DP.TYP.
M3 X 0.5 OPTIONAL
Note: 4-pole models furnished with separate
handle tie hardware.
480V Model with Barriers
Model with Aux. Relay Trip Pole
2.778
(70.56)
2.250
(57.15)
.269
(6.83)
Note: W68 -D model shown. Note that the
auxiliary relay trip pole is on the right.
#10-32 screw terminals must be
specified with this option; however,
the terminals on the relay trip pole
are 0.250” quick connects.
2.530
(64.26)
The relay pole is self-opening, so the
trip current can remain energized
indefinitely.
.266
(6.76)
Note: 3-pole model shown.
Termination Options
VDE Models
W/Screw Terminals
UL/CSA Models
W/Screw Terminals
UL/CSA/VDE Models
W/Aux. Switch
UL/CSA Models
W/Terminals Bent 30°
Notes:
1. Terminal protrusion dimensions are
referenced from back of mounting panel.
2. Main terminals are male quick connect
type .250 (6.35) wide x .031 (.79) thick x
.377 (9.58) long. Optional 8-32 x .250
(6.35) or 10-32 x .250 (6.35) screw type.
3. Panel mounting cutout detail mtg. detail
tol.: .005 (.13) unless noted. Add
additional cutouts to correspond to
number of poles. Outline drawing
tolerance .015 (.38) unless noted.
.235
2.032
2.380
(60.45)
(5.97)
(51.61)
LINE
.416
LINE
LINE
LINE
A
A
A
(10.56)
C
1.058
(26.97)
.827
(21.00)
NO
NC
1.520
(38.61)
B
B
B
LOAD
LOAD
LOAD
LOAD
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
5
UK: 44-8706-080208
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Outline Dimensions - Optional Toggle Guards
W6 Series
1.375 INSIDE
(34.92)
.625 INSIDE
(15.88)
2.185 INSIDE
(55.50)
1.093
.03
(.76)
.313
(7.95)
(27.76)
.313
(7.95)
.75
(19.05)
.75
.75
(19.05)
(19.05)
.2 x
R1.0
(25.4)
.47
.78
(19.8)
(11.94)
.95
.17
(4.32)
(24.1)
.17 REF.
(4.32)
.08
(2.03)
.625
(15.88)
2.00
(50.8)
1.66
(42.16)
2 x
.27 DIA.
(6.86)
.44
(11.18)
84-004 toggle guard shown
with W67 series circuit
breaker mounted in a panel.
.53
(13.46)
2 x .16 DIA.
(4.06)
.20
(5.08)
4 x .16 DIA.
(4.06)
6 x .16 DIA.
(4.06)
84-004
(For 1 Pole
Breaker)
84-005
(For 2 Pole
Breaker)
84-006
(For 3 Pole
Breaker)
Optional toggle guards may be ordered separately for use on W6 toggle actuator models. These guards help to prevent accidental operation and allow the breaker to be
locked in the “off” position.
Outline Dimensions - Rocker Actuator Models
W6 Series
1 Pole
2, 3 & 4 Pole, One Actuator Per Pole
(Shown with optional “ON”
and “OFF” graphics)
3.000
(76.20)
.750
(19.05)
4
2.250
(57.15)
POLE
1.769
(44.93)
.774
(19.65)
3
1.500
.375
(9.53)
.240
(6.10)
POLE
(38.10)
.392
(9.96)
2 POLE
.180
(4.57)
LOAD
D
A
.388
(9.86)
2.000
(50.80)
1.660
(42.16)
1.520
(38.61)
ON
2.600
(66.04)
OFF
1.30
(33.0)
LINE
.375
(9.53)
TAPPED FOR #6-32
M3 X 0.5 OPTIONAL
.750
(19.05)
.750
(19.05)
2.435
(61.85)
.750
(19.05)
2, 3 & 4 Pole, One Actuator Per Unit
1.500
(38.10)
2.250
(57.15)
3.000
(76.20)
.388
(9.86)
2.000
(50.80)
1.660
(42.16)
1.660
(42.16)
2.600
(66.04)
.375
(9.53)
.375
(9.53)
.750
.750
(19.05)
.750
(19.05)
.375
(9.53)
(19.05)
TAPPED FOR #6-32
.750
.750
(19.05)
.750
(19.05)
M3 X 0.5 OPTIONAL
(19.05)
Panel Mounting Cutout
VDE Rocker Marking
.750
(19.05)
.750
(19.05)
.205
(5.21)
.375
(9.53)
.750
(19.05)
1.250
(31.75)
I
1.660
(42.16)
O
Notes:
1. Outline drawing tolerance .015 (.38) unless
noted. Dimensions in brackets ( ) are in
millimeters.
2. Mounting Detail Tol.: .005 (.13) unless noted
.750
(19.05)
1 POLE
2 POLE
3 POLE
4 POLE
1.500
(38.10)
Ø .156
(3.96)
TYP. 2
2.250
(57.15)
PER POLE
3.000
(76.20)
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
6
UK: 44-8706-080208
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
Outline Dimensions
W9 Series
Series Trip Model
Series Trip Model
.060
.750
(19.05)
.375
(9.53)
.750
(19.05)
.750
(19.05)
1.845
(1.52)
(46.86)
.398
(10.11)
.375
(9.53)
.375
(9.52)
.313
(7.95)
.281
(7.14)
.750
(19.05)
1.15
(29.21)
LINE
.060
(1.52)
ON
ON ON
OFFOFF
ON ON ON ON ON ON ON ON
OFFOFF OFFOFF OFFOFF OFFOFF
Note:
.218
(5.54)
2.065
(52.45)
29°
30°
1. Top mounted plate
(shown with broken
line) is present only on
UL1500 models.
1.438
(36.53)
1.940
(49.28)
2.50
(63.5)
OFF
LOAD
#10-32
STUD
2 POLE
1.500
(38.10)
.14
(3.56)
1 POLE
2.10
(53.34)
TERMINATION
2.250
(57.15)
3POLE
TAPPED #6-32 X .16 (4.06)
DEEP
M3 X 0.5 OPTIONAL
2.50
(64.00)
.74
(18.8)
3.000
4 POLE
(76.20)
Series Trip Model
Panel Mounting Cutout Detail
With Common Enclosed Auxiliary Switch
.750
(19.05)
.750
(19.05)
Notes:
.732
(18.59)
.281
2.46
.750
(19.05)
.385
1. Terminal protrusion
dimensions are referenced
from the back of the
mounting panel.
'A' STYLE
(7.14)
(9.78)
(62.48)
.907
(23.04)
LINE
2. Mounting detail tolerance
.005 (13) unless noted.
3. Outline drawing tolerance
.015 (.38) unless noted.
Dimensions in brackets ( )
are in millimeters.
1.450
C
NO
(36.83)
2.065
(52.45)
1.940
(49.28)
NC
LOAD
.76
(19.3)
2X Ø .156
(3.96)
PER POLE
1 POLE
1.52
(38.6)
2 POLE
3 POLE
4 POLE
2.50
(64.00)
2.28
(57.9)
3.04
(77.2)
Disclaimer:
While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this
document, Tyco Electronics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any representation or offer any
guarantee that such information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information at any
time. Tyco Electronics expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied
warranties of merchantability or fitness for a particular purpose. Tyco Electronics‘ only obligations are those stated in Tyco Electronics’ Standard Terms and
Conditions of Sale. Tyco Electronics will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including,
but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate the suitability of a product for a certain
purpose and test each product for its intended application.
In case of any potential ambiguities or questions, please don’t hesitate to contact us for clarification.
© 2010 by Tyco Electronics Corporation. All Rights Reserved.
P&B, Potter & Brumfield, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors.
Revised 03-10
www.tycoelectronics.com
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
7
UK: 44-8706-080208