7-1393277-9 [MACOM]
Limiting continuous current 32 A at 85°C;型号: | 7-1393277-9 |
厂家: | Tyco Electronics |
描述: | Limiting continuous current 32 A at 85°C |
文件: | 总6页 (文件大小:349K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Features
– Limiting continuous
current 32 A at 85°C
– Wide voltage range
Typical Applications
– ABS control
– Blower fans
– Car alarm
– Cooling fan
– Engine control
– Fuel pump
– Hazard warning signal
– Heated front screen
– Heated rear screen
– Ignition
– Lamps front, rear, fog light
– Interior lights
– Main switch/supply relay
– Seat control
– Seatbelt pretensioner
– Sun roof
– Turn signal
– Valves
– Window lifter
– Wiper control
Please contact Tyco Electronics
for relay application support.
VKP_3d01
Design
Terminals
Conditions
– ELV compant
– Open: flux tight type
– aled: washable type
PCB terminals, for assembly on
printed circuit boards
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
eight
Approx. 19 g (0.67 oz.)
open version
23°C ambient temperature,
20 - 50% RH, 998.9 33.9 hPa.
– Approx. 22 g (0.77 oz.)
sealed version
For general storage and processing
recommendations please refer to our
Application Notes and especially to
Storage in the “Glossary” page 23 or
at http://relays.tycoelectronics.com/
appnotes/
Nominal Voltage
12 V or 24 V
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.
All rights of Tyco Electronics are reserved.
156
All specifications subject to change. Consult Tyco Electronics for latest specifications.
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Dimensional Drawing
VKP Open Version
Dimensional Drawing
VKP Sealed Version
1.04 MAX.
(26.5)
.866 MAX.
(22.0)
.748 MAX.
(19.0)
.911 MAX.
(23.1)
.715 MAX.
(18.2)
.878 MAX.
(22.3)
ECR2131-E
ECR2130-6
.150 MAX.
(3.8)
.150 MAX.
(3.81
EXDING
LDER
Mounting Hole Layout (bottom view)
Open version
Sealed Version
ø .055
ø .055
(1.4)
2 x .083
(1.4)
2x .083
(2.1)
(2.1)
.062
(1.6)
3
3
4
5
1 2
2 x .043
(1.1)
2 x .043
5
1 2
.086
(2.2)
(1.1)
4
4
4
4
2 x .086
(2.2)
2 x .062
(1.6)
2 x .062
(1.6)
2 x .086
(2.2)
.586
(14.88)
.211
.211
(5.35)
.134
(3.4)
.147
(3.73)
.19 MAX.
(4.8)
.148
(5.35)
.148
(3.75)
.289 MAX.
(7.3)
(3.75)
.213
(5.4)
3
3
4
2
5
5
1
1
2
.147
(3.73)
.467
(11.87)
.467
(11.87)
.092
(2.33)
4
4
4
ECR2132-M
ECR2133-V
.161
(4.08
.161
(4.08)
.483
(12.28)
.483
(12.28)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
157
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Contact Data
Typical areas of application
Contact configuration
Resistive/inductive loads
High inrush, lamp and capacitive lo
1 Make contact/
1 Form A
1 Changeover contact/
1 Form C
1 Make contact/
1 Form A
1 Changeover conta
1 For
Circuit symbol
5
5
3
3
(see also Pin assignment)
4
4
Rated voltage
Rated current
12 V
NC/NO
NC/NO
32 A
25/32 A
32 A
25/32 A
Limiting continuous current
23°C
85°C
105°C
40 A
32 A
25 A
30/40 A
25/32 A
15/25 A
40 A
32 A
2
30/40 A
25/32 A
15/25 A
Contact material
AgNi0.15 (VKP-***42)
AgSnO2 (VKP-***52)
Max. switching voltage/power
Max. switching current
On 1)
See load limit curve
NC/NO
NC/NO
30 A/180 A
30 A/60 A
100 A
60 A
30 A/100 A
30 A/60 A
180 A
60 A
2)
Off
Min. recommended current
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
1 t 5 V
Typ. 15 mV
Typ. 20/15 mV
Typ. 20 mV
Typ. 25/20 mV
107 operations
105 oprations at 40 A, 14 V,
(example of resistive load)
on NO contact
1)
Inrush current for lamp load.
See load limit curve.
2)
Load Limit Curve
128-U
75
60
50
40
Safe breaking, arc extinguished (normally
open contact) for resistive loads.
30
20
12
10
7
0.5
1
2
3
4
10
20
30 40
Swithinnt (A)
Circuit Diagram
1 Make contact/1 Form A
1 Changeover contact/1 Form C
TE1086-A1
TE1091-B1
158
All specifications subject to change. Consult Tyco Electronics for latest specifications.
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Contact Data
Typical areas of application
Contact configuration
Flashing lamps
1 Make contact/
1 Form A
1 Changeover contact/
1 Form C
Circuit symbol
5(–)
3
(see also Pin assignment)
4(+)
Rated voltage
12 V
Rated current
30 A
20/30 A
Limiting continuous current
23°C
85°C
105°C
35 A
30 A
25 A
A
20/30 A
15/25 A
Contact material
AgSnO2 (VKP-***72) 1)
Max. switching voltage/power
Max. switching current
See load limit curve on previous page
High current version
High current version
NC/NO
On2)
Off
240 A
30 A
60/240 A
20/30 A
NC/NO
Steady-state flashing3)
Open
Sealed
Alternate flashing4)
30 A
25 A
10/30 A
10/25 A
NC/NO
Open
8/8 A
Sealed
8/8 A
Min. recommended load5)
1 A at 5 V
Voltage drop (initial) at 10 A
100 mV max. for NO contacts,
200 mV max. for NC contacts, typ. 40 mV
Typ. 107 operations
See application information below
Mechanical endurance (without load)
Electrical endurance
1)
Center contact pin 4 to be connected to positive potential.
Inrush current for lamp load.
Continuous On-Off cycling of a single set of lamps at 60 to 90 oeraions per minute and approx. a 50% duty cycle.
Continuous cycling between two sets of lamps with one set switched by the NO contacts and the other by the NC contacts, at 60 to 90 operations per minute
and approx. a 50% duty cycle.
2)
3)
4)
5)
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/
Coil Data
Available for nominal voltages
Nominal power consumption of the unsuppressed coil at nominal voltage
Test voltage winding/contact
Maximum ambient temperature r
Operate time at nominal voltage
12 V / 24 V
1.6 W
500 VACrms
–40 to +125°C
Typ. 5 ms
Release time at nominvoltage 1)
Typ. 3 ms
1) For unsuppressed ry coil.
Note:
A low resistive sppression device in parallel to the relay coil increases the release time and reduces
the lifetime aused by increased erosion and/or higher risk of contact tack welding.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
159
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Application Information
Electrical Life Test Information
Load Polarity: VKP series relays for flashing lamp applications are constructed
with special AgSnO movable contacts and standard AgSnO stationary contacts.
This causes the relay to be sensitive to the polarity of the load voltage. This type
of VKP relay must be mechanized in the circuit such that the more positive con-
nection is made to the movable contact (identified as terminal 4 in the wiring
diagrams). Failure to do so will nullify the benefit of the special AgSnO contact
material and will result in significantly reduced relay life.
High current relays: 3 bulb T/S system, combined turn signal and ha
warning with special trailering (test requirements):
3 bulb
6 bulb
7 bulb
14 bulb
TOTAL
2.1 million operations
194 K operations
259 K operations
497 K operations
3.0 million operations
This application represents about the limit of the performance capability of the
"Flashing Lamp” type VKP relay. It should be noted ththe low current operations
have very little effect on the product life where as tbulb (only) loads can be
expected to fail at less than 1 million operations.
Typical Applications: Typical applications: VKP series relays for flashing lamp
applications are typically used for turn signals, hazard warning, emergency vehi-
cle, and security system applications. They may also be suitable for high in-rush
current capacitive loads such as audio amplifiers. Use on inductive loads or loads
with high continuous load currents should be avoided. The relay should also not
be used in applications, which do not have a significant make current, as high
contact voltage drop may result.
Note: Bulb as used here is a 27 Watt turn sbulb, trade #1156. Testing
includes operations at –40°C, 23°C, and 85°C.
Design Considerations: It should noted that although the VKP series relays
are capable of handling relatively gh urrents, when applying the product under
high current and high ambient temperature conditions, providing adequate con-
ductor volume is critical, as is the solder connection, particularly with respect to
the normally open contact termnal. It may be necessary to use high temperature
solder, a plated throue PCB, or copper lead frame type construction under
these conditions to pret failure of the solder joint.
Note: The VKP-***72 series relay with special AgSnO contact material replaces
the VKP-XXX32 standard current and the VKP-***62 high current PdCu/AgNi0.15
contact relays.
High Current Relays: VKP-***72 series relays for flashing lamp applications are
generally suitable for passenger car, light truck with or without special trailering
requirements, and medium duty truck, and emergency vehicle applications. They
are also generally suitable for security system applications for flashing lamps
and for most audio amplifier applications. This relay is also recommended for
alternating flasher applications, such as emergency vehicles. This version has
much improved performance on the normally open contacts, so optimum life can
be attained for alternating applications by using two normally open relays and
powering the coils alternately.
160
All specifications subject to change. Consult Tyco Electronics for latest specifications.
PCB Relays
Single Relays
Catalog 1308028-2
Revised 6-2009
VKP (Open – Sealed)
Environmental Conditions
Temperature range, storage
Test
Vibration resistance
Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/
Relevant standard
Testing as per
Dimension
10 - 40 Hz
40 - 70 Hz
70 - 100 Hz
100 - 500 Hz
11 ms
Comments
1.27 mm double amplitude
Valid for NC c.
NO cntats are
significantlhgher
5 g constant
0.5 mm double amplitude
10 g constant
Shock resistance
Half sine wave pulse
No change in the
20 g
sng state > 10 μs
Jump start
Drop test
Flammability
24 V for 5 minutes conducting nominal current at 23°C
Capable of meeting specifications after 1.0 m (3.28 ft) drop onto concrete ifinal enclosure
UL94-HB or better, internal parts (meets FMVSS 302)
Ordering Information
Part Numbers
(see table below for coil data)
Contact
Arrangement
Contact
Material
Enclosure
Applications
Relay Description
Part Number
VKP-11F42
VKP-11H42
VKP-15F42
VKP-15H42
VKP-15F52
VKP-31F42
VKP-31H42
VKP-35F42
VKP-35H42
VKP-31F52
VKP-31H52
VKP-35F52
VKP-35H52
VKP-11F72
VKP-15F72
VKP-31F72
VKP-35F72
3-1393277-7
5-1419148-4
0-1393278-1
5-1393277-5
5-1393277-1
0-1393277-1
0-1393277-2
0-1393277-3
7-1393277-9
6-1393277-2
0-1432198-1
7-1393277-3
0-1432197-1
0-1432444-1
0-1432445-1
0-1432413-1
0-1432438-1
1 Form A
1 Form A
1 Form C
1 Form C
1 Form C
1 Form A
1 Form A
1 Form C
1 Form C
1 Form A
1 Form A
1 Form C
1 Form C
1 Form A
1 Form
1 Form A
1 Form C
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgSnO2
AgNi0.15
AgNi0.15
AgNi015
AgN0.15
gSnO2
AgSnO2
AgSnO2
AgSnO2
Open
pen
en
Open
Open
Sealed
Sealed
Sealed
Sealed
Sealed
Sealed
Sealed
Sealed
Open
General automotive loads
General automotive loads
General automotive loads
General automotive loads
High inrush loads
General automotive loads
General automotive loads
General automotive loads
General automotive loads
High inrush loads
High inrush loads
High inrush loads
High inrush loads
Flashing lamp loads
Flashing lamp loads
Flashing lamp loads
Flashing lamp loads
Special AgSnO2
Special AgSnO2
Special AgSnO2
Special AgSnO2
Open
Sealed
Sealed
Coil Versions
Coil Data
for
VKP
VKP-**F**2)
VKP-**H**2)
Rated Coil
Voltage
(V)
Coil Resistance
Must
Operate Voltage
Must
Release Voltage
Allowable Overdrive1)
Voltage (V)
at 85°C
1ꢀ0
(Ω)
90
(V)
6.8
13.9
(V)
1.2
2.4
at 23°C
19.6
1
2
14.3
362
39.3
28.6
1)
Allowable overdrive is stated with no load applied and minimum coil resistance.
On request.
2)
Standard Deliery Packs (orders in multiples of delivery pack)
VKP:
525 pieces
All specifications subject to change. Consult Tyco Electronics for latest specifications.
161
相关型号:
©2020 ICPDF网 联系我们和版权申明