DS75LV  
Digital Thermometer and Thermostat  
General Description  
Benefits and Features  
● Extend Performance Range with Low-Voltage,  
The DS75LV low-voltage (1.7V to 3.7V) digital thermometer  
and thermostat provides 9, 10, 11, or 12-bit digital temperature  
readings over a -55°C to +125°C range with ±2°C accuracy  
over a -25°C to +100°C range. At power-up, the DS75LV  
defaults to 9-bit resolution for software compatibility with the  
LM75. Communication with the DS75LV is achieved through  
a simple 2-wire serial interface.  
1.7V to 3.7V Operating Range  
● Maximize System Accuracy in Broad Range of  
Thermal Management Applications  
• Measures Temperature from -55°C to +125°C  
(-67°F to +257°F)  
±2°C Accuracy over a -25°C to 100°C Range  
User-Configurable Resolution from 9 Bits (Default)  
to 12 Bits (0.5°C to 0.0625°C)  
The DS75LV thermostat has a dedicated open-drain output  
(OS) and programmable fault tolerance, which allows the  
user to define the number of consecutive error conditions that  
must occur before OS is activated. There are two thermostatic  
operating modes that control thermostat operation based on  
● Easy Upgrade to LM75: Pin and Software Compatible  
Simplify Distributed Temperature-Sensing  
Applications with Multidrop Capability  
user-defined trip-points (T and T  
).  
HYST  
OS  
Up to Eight DS75LVs Can Operate on 2-Wire Bus  
● Increase Reliability and System Robustness  
• Internally Filtered Data Lines for Noise Immunity  
(50ns Deglitch)  
Applications  
Personal Computers  
Cellular Base Stations  
● Office Equipment  
Bus Timeout Feature Prevents Lockup on 2-Wire  
Interface  
Any Thermally Sensitive System  
● Minimize Power Consumption with Built-In Shutdown  
Mode  
Ordering Information appears at end of data sheet.  
● Flexible User-Defined Thermostatic Modes with  
Programmable Fault Tolerance  
Functional Block Diagram  
PRECISION  
OVERSAMPLING  
DIGITAL  
REFERENCE  
MODULATOR  
DECIMATOR  
V
DD  
CONFIGURATION  
REGISTER  
SCL  
SDA  
ADDRESS  
AND  
I/O CONTROL  
TEMPERATURE  
REGISTER  
A0  
A1  
A2  
R
P
OS  
TOS AND THYST  
REGISTERS  
THERMOSTAT  
COMPARATOR  
GND  
DS75LV  
19-7469; Rev 5; 11/16  
DS75LV  
Digital Thermometer and Thermostat  
Absolute Maximum Ratings  
Voltage on V , Relative to Ground....................-0.3V to +4.0V  
Storage Temperature Range............................ -55°C to +125°C  
DD  
Voltage on Any Other Pin, Relative to Ground ....-0.3V to +6.0V  
Operating Temperature Range......................... -55°C to +125°C  
Lead Temperature (soldering, 10s) .................................+260°C  
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these  
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect  
device reliability.  
DC Electrical Characteristics  
(1.7V ≤ V  
≤ 3.7V, T = -55°C to +125°C, unless otherwise noted.)  
DD  
A
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
Supply Voltage  
V
DD  
1.7  
3.7  
V
0 to +50  
±0.5  
Thermometer Error (Note 1)  
T
-25 to +100  
-55 to +125  
(Note 2)  
±2.0  
±3.0  
5.5  
°C  
ERR  
Input Logic-High  
Input Logic-Low  
V
0.7 x V  
V
V
IH  
DD  
V
(Note 2)  
-0.5  
0
0.3 x V  
0.4  
IL  
DD  
V
V
3mA sink current  
6mA sink current  
SDA Output Logic Low Voltage  
(Note 2)  
OL1  
V
V
0
0.6  
OL2  
OS Saturation Voltage  
V
4mA sink current (Notes 1, 2)  
0.8  
OL  
Input Current Each I/O Pin  
I/O Capacitance  
0.4 < V < 0.9 x V  
-10  
+10  
10  
2
µA  
pF  
µA  
I/O  
DD  
C
I/O  
Standby Current  
I
(Notes 3, 4)  
DD1  
Active temp conversions  
Communication only  
1000  
100  
Active Current (Notes 3, 4)  
I
µA  
DD  
AC Electrical Characteristics  
(1.7V ≤ V  
≤ 3.7V, T = -55°C to +125°C, unless otherwise noted.)  
DD  
A
PARAMETER  
SYMBOL  
CONDITIONS  
9-bit conversions  
MIN  
TYP  
MAX  
12  
UNITS  
Resolution  
9
Bits  
25  
10-bit conversions  
11-bit conversions  
12-bit conversions  
50  
Temperature Conversion Time  
t
ms  
CONVT  
100  
200  
400  
SCL Frequency  
f
kHz  
SCL  
Bus Free Time Between a  
STOP and START Condition  
t
(Note 5)  
1.3  
µs  
BUF  
START and Repeated START  
Hold Time from Falling SCL  
t
(Notes 5, 6)  
600  
ns  
HD:STA  
Maxim Integrated  
2  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
AC Electrical Characteristics (continued)  
(1.7V ≤ V  
≤ 3.7V, T = -55°C to +125°C, unless otherwise noted.)  
DD  
A
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
1.3  
TYP  
MAX  
UNITS  
µs  
Low Period of SCL  
High Period of SCL  
t
(Note 5)  
(Note 5)  
LOW  
t
0.6  
µs  
HIGH  
Repeated START Condition  
Setup Time to Rising SCL  
t
(Note 5)  
(Notes 5, 7)  
(Note 5)  
(Note 5)  
(Note 5)  
600  
0
ns  
µs  
ns  
ns  
ns  
ns  
ns  
pF  
SU:STA  
Data-Out Hold Time from  
Falling SCL  
t
0.9  
HD:DAT  
Data-In Setup Time to Rising  
SCL  
t
100  
SU:DAT  
Rise Time of SDA and SCL  
(Receive)  
t
1000  
300  
50  
R
Fall Time of SDA and SCL  
(Receive)  
t
F
Spike Suppression Filter Time  
(Deglitch Filter)  
t
0
SS  
STOP Setup Time to Rising  
SCL  
t
(Note 5)  
600  
SU:STO  
Capacitive Load for Each Bus  
Line  
C
400  
325  
B
Input Capacitance  
C
5
pF  
I
Serial Interface Reset Time  
t
SDA time low (Note 8)  
75  
ms  
TIMEOUT  
Note 1: Internal heating caused by OS loading causes the DS75LV to read approximately 0.5°C higher if OS is sinking the max  
rated current.  
Note 2: All voltages are referenced to ground.  
Note 3:  
Note 4:  
I
I
specified with V  
specified with OS pin open.  
at 3.0V and SDA, SCL = 3.0V, 0°C to +70°C.  
DD  
DD  
DD  
Note 5: See Figure 2 for timing diagram. All timing is referenced to 0.9 x V  
and 0.1 x V  
.
DD  
DD  
Note 6: After this period, the first clock pulse is generated.  
Note 7: The DS75LV provides an internal hold time of at least 75ns on the SDA signal to bridge the undefined region of SCL’s  
falling edge.  
Note 8: This timeout applies only when the DS75LV is holding SDA low. Other devices can hold SDA low indefinitely and the  
DS75LV does not reset.  
Maxim Integrated  
3  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Pin Description  
PIN  
1
NAME  
SDA  
SCL  
OS  
FUNCTION  
Data Input/Output. For 2-wire serial communication port. Open drain.  
2
Clock Input. 2-wire serial communication port.  
Thermostat Output. Open drain.  
Ground  
3
4
GND  
A2  
5
Address Input  
6
A1  
Address Input  
7
A0  
Address Input  
8
V
Supply Voltage. +1.7V to +3.7V supply pin.  
DD  
PRECISION  
REFERENCE  
OVERSAMPLING  
MODULATOR  
DIGITAL  
DECIMATOR  
V
DD  
CONFIGURATION  
REGISTER  
SCL  
SDA  
ADDRESS  
AND  
I/O CONTROL  
TEMPERATURE  
REGISTER  
A0  
A1  
A2  
R
P
OS  
TOS AND THYST  
REGISTERS  
THERMOSTAT  
COMPARATOR  
GND  
DS75LV  
Figure 1. Block Diagram  
SDA  
t
F
t
F
t
t
t
BUF  
SP  
R
t
SU;DAT  
t
HD;STA  
t
t
R
LOW  
SCL  
t
HD;STA  
t
t
SU;STO  
SU;STA  
t
HD;DAT  
S
Sr  
P
S
Figure 2. Timing Diagram  
Maxim Integrated  
4  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Bits 3 through 0 of the temperature register are hardwired  
to 0. When the DS75LV is configured for 12-bit resolution,  
the 12 MSbs (bits 15 through 4) of the temperature register  
contain temperature data. For 11-bit resolution, the 11  
MSbs (bits 15 through 5) of the temperature register  
contain data, and bit 4 reads out as 0. Likewise, for 10-bit  
resolution, the 10 MSbs (bits 15 through 6) contain data,  
and for 9-bit the 9 MSbs (bits 15 through 7) contain data,  
and all unused LSbs contain 0s. Table 1 gives examples  
of 12-bit resolution digital output data and the corresponding  
temperatures.  
Detailed Description  
Measuring Temperature  
The DS75LV measures temperature using a bandgap  
temperature sensing architecture. An on-board delta-sigma  
analog-to-digital converter (ADC) converts the measured  
temperature to a digital value that is calibrated in degrees  
centigrade; for Fahrenheit applications a lookup table or  
conversion routine must be used. The DS75LV is factory-  
calibrated and requires no external components to measure  
temperature.  
At power-up the DS75LV immediately begins converting  
temperature to a digital value. The resolution of the  
digital output data is user-configurable to 9, 10, 11, or  
12 bits, corresponding to temperature increments of  
0.5°C, 0.25°C, 0.125°C, and 0.0625°C, respectively, with  
9-bit default resolution at power-up. The resolution is  
controlled via the R0 and R1 bits in the configuration  
register as explained in the Configuration Register  
section. Note that the conversion time doubles for each  
additional bit of resolution.  
Table 1. 12-Bit Resolution Temperature/  
Data Relationship  
DIGITAL  
OUTPUT  
(HEX)  
TEMPERATURE  
DIGITAL OUTPUT  
(°C)  
(BINARY)  
+125  
+25.0625  
+10.125  
+0.5  
0111 1101 0000 0000  
0001 1001 0001 0000  
0000 1010 0010 0000  
0000 0000 1000 0000  
0000 0000 0000 0000  
1111 1111 1000 0000  
1111 0101 1110 0000  
1110 0110 1111 0000  
1100 1001 0000 0000  
7D00h  
1910h  
0A20h  
0080h  
0000h  
FF80h  
F5E0h  
E6F0h  
C900h  
After each temperature measurement and analog-to-digital  
conversion, the DS75LV stores the temperature as a 16-bit  
two’s complement number in the 2-byte temperature register  
(see Figure 3). The sign bit (S) indicates if the temperature  
is positive or negative: for positive numbers S = 0 and for  
negative numbers S = 1. The most recently converted digital  
measurement can be read from the temperature register at  
any time. Since temperature conversions are performed in  
the background, reading the temperature register does not  
affect the operation in progress.  
0
-0.5  
-10.125  
-25.0625  
-55  
bit 15  
S
bit 14  
bit 13  
bit 12  
bit 11  
bit 10  
bit 9  
bit 8  
6
5
4
3
2
1
0
MS Byte  
LS Byte  
2
2
2
2
2
2
2
bit 7  
bit 6  
bit 5  
bit 4  
bit 3  
0
bit 2  
0
bit 1  
0
bit 0  
0
-1  
2
-2  
2
-3  
2
-4  
2
Figure 3. Temperature, T , and T  
OS  
Register Format  
HYST  
Maxim Integrated  
5  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
and T  
HYST  
registers. The OS output is updated based on  
Shutdown Mode  
the result of the comparison and the operating mode of the  
IC. The number of T and T bits used during the  
thermostat comparison is equal to the conversion resolution  
set by the R1 and R0 bits in the configuration register. For  
For power-sensitive applications, the DS75LV offers  
a low-power shutdown mode. The SD bit in the  
configuration register controls shutdown mode. When SD  
is changed to 1, the conversion in progress is completed  
and the result stored in the temperature register after  
which the DS75LV goes into a low-power standby state.  
The OS output is cleared if the thermostat is operating in  
interrupt mode and OS remains unchanged in comparator  
mode. The 2-wire interface remains operational in shut-  
down mode, and writing a 0 to the SD bit returns the  
DS75LV to normal operation.  
OS  
HYST  
example, if the resolution is 9 bits, only the 9 MSbs of T  
OS  
and T  
are used by the thermostat comparator.  
HYST  
The active state of the OS output can be changed via the  
POL bit in the configuration register. The power-up default  
is active low.  
If the user does not wish to use the thermostat capabilities  
of the DS75LV, the OS output should be left floating. Note  
that if the thermostat is not used, the T  
registers can be used for general storage of system data.  
and T  
OS  
HYST  
Thermostat  
The DS75LV thermostat has two operating modes, com-  
parator mode and interrupt mode, which activate and  
deactivate the open-drain thermostat output (OS) based  
on user-programmable trip-points (T  
DS75LV powers up with the thermostat in comparator  
Comparator Mode: When the thermostat is in compara-  
tor mode, OS can be programmed to operate with any  
amount of hysteresis. The OS output becomes active  
and T  
). The  
OS  
HYST  
when the measured temperature exceeds the T  
value  
OS  
a consecutive number of times as defined by the F1 and  
F0 fault tolerance (FT) bits in the configuration register. OS  
then stays active until the first time the temperature falls  
mode, active-low OS polarity, over-temperature trip-point  
(T ) register set to 80°C, and the hysteresis trip-point  
OS  
(T  
) register set to 75°C. If these power-up settings  
HYST  
below the value stored in T  
. Putting the device into  
are compatible with the application, the DS75LV can be  
used as a standalone thermostat (i.e., no 2–wire com-  
munication required). If interrupt mode operation, active-  
HYST  
shutdown mode does not clear OS in comparator mode.  
Thermostat comparator mode operation with FT = 2 is  
illustrated in Figure 4.  
high OS polarity or different T  
and T  
values are  
OS  
HYST  
desired, they must be programmed after power-up, so  
standalone operation is not possible.  
Interrupt Mode: In interrupt mode, the OS output first  
becomes active when the measured temperature exceeds  
the T  
value a consecutive number of times equal to the  
In both operating modes, the user can program the ther-  
mostat fault tolerance, which sets how many consecutive  
temperature readings (1, 2, 4, or 6) must fall outside of  
the thermostat limits before the thermostat output is trig-  
gered. The fault tolerance is set by the F1 and F0 bits in  
the configuration register. At power-up the fault tolerance  
is set to 1.  
OS  
FT value in the configuration register. Once activated, OS  
can only be cleared by either putting the DS75LV into  
shutdown mode or by reading from any register (temperature,  
configuration, T , or T  
has been deactivated, it is only reactivated when the  
) on the device. Once OS  
OS  
HYST  
measured temperature falls below the T value a  
HYST  
consecutive number of times equal to the FT value. Again,  
OS can only be cleared by putting the device into shut-  
down mode or reading any register. Thus, this interrupt/  
The data format of the T  
OS  
and T registers is identical  
HYST  
to that of the temperature register (see Figure 3), i.e., a  
2-byte two’s complement representation of the trip-point  
temperature in degrees centigrade with bits 3 through 0  
hardwired to 0. After every temperature conversion, the  
clear process is cyclical between T  
and T  
events  
, clear,  
OS  
HYST  
(i.e, T , clear, T  
, clear, T , clear, T  
OS  
HYST  
OS HYST  
etc.). Thermostat interrupt mode operation with FT = 2 is  
measurement is compared to the values stored in the T  
OS  
illustrated in Figure 4  
.
Maxim Integrated  
6  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
register is arranged as shown in Figure 5 and detailed  
descriptions of each bit are provided in Table 2. The  
user has read/write access to all bits in the configuration  
register except the MSb, which is a reserved read-only  
bit. The entire register is volatile, and thus powers up in  
its default state.  
Configuration Register  
The configuration register allows the user to program  
various DS75LV options such as conversion resolution,  
thermostat fault tolerance, thermostat polarity, thermostat  
operating mode, and shutdown mode. The configuration  
IN THIS EXAMPLE THE DS75LV  
IS CONFIGURED TO HAVE A FAULT  
TOLERANCE OF 2.  
T
OS  
TEMPERATURE  
T
HYST  
INACTIVE  
OS OUTPUT - COMPARATOR MODE  
ACTIVE  
INACTIVE  
OS OUTPUT - INTERRUPT MODE  
ACTIVE  
ASSUMES A READ  
HAS OCCURRED  
CONVERSIONS  
Figure 4. OS Output Operation Example  
MSb  
0
BIT 6  
BIT 5  
R0  
BIT 4  
F1  
BIT 3  
F0  
BIT 2  
POL  
BIT 1  
TM  
LSb  
SD  
R1  
Figure 5. Configuration Register  
Maxim Integrated  
7  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Table 2. Configuration Register Bit Descriptions  
BIT NAME  
FUNCTION  
0
Power-up state = 0  
Reserved  
The master can write to this bit, but it will always read out as a 0.  
R1  
Power-up state = 0  
Conversion Resolution Bit 1  
Sets conversion resolution (see Table 3)  
R0  
Power-up state = 0  
Conversion Resolution Bit 0  
Sets conversion resolution (see Table 3)  
F1  
Power-up state = 0  
Thermostat Fault Tolerance Bit 1  
Sets the thermostat fault tolerance (see Table 4).  
F0  
Power-up state = 0  
Thermostat Fault Tolerance Bit 0  
Sets the thermostat fault tolerance (see Table 4).  
Power-up state = 0  
POL = 0 — OS is active low.  
POL = 1 — OS is active high.  
POL  
Thermostat Output (OS) Polarity  
Power-up state = 0  
TM  
TM = 0 — Comparator mode  
Thermostat Operating Mode  
TM = 1 — Interrupt mode  
See the Thermostat section for a detailed description of these modes.  
Power-up state = 0  
SD  
Shutdown  
SD = 0 — Active conversion and thermostat operation.  
SD = 1 — Shutdown mode.  
See the Shutdown Mode section for a detailed description of this mode.  
Table 3. Resolution Configuration  
Table 5. Register Pointer Definition  
REGISTER  
Temperature  
Configuration  
P1  
0
P0  
0
THERMOMETER  
RESOLUTION  
MAX CONVERSION  
R1  
R0  
TIME (ms)  
0
0
1
1
0
1
0
1
9-bit  
10-bit  
11-bit  
12-bit  
25  
50  
0
1
T
1
0
HYST  
OS  
100  
200  
T
1
1
Table 4. Fault Tolerance Configuration  
CONSECUTIVE OUT-OF-LIMITS  
CONVERSIONS TO TRIGGER OS  
F1  
F0  
0
0
1
1
0
1
0
1
1
2
4
6
Maxim Integrated  
8  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Receiver: A device (master or slave) that is receiving data  
from the bus.  
Register Pointer  
The four DS75LV registers each have a unique 2-bit  
pointer designation, which is defined in Table 5. When  
reading from or writing to the DS75LV, the user must  
“point” the DS75LV to the register that is to be accessed.  
When reading from the DS75LV, once the pointer is set,  
it remains pointed at the same register until it is changed.  
For example, if the user desires to perform consecutive  
reads from the temperature register, then the pointer only  
has to be set to the temperature register one time, after  
which all reads are automatically from the temperature  
register until the pointer value is changed. When writing  
to the DS75LV, the pointer value must be refreshed each  
time a write is performed, even if the same register is  
being written to twice in a row.  
START Condition: Signal generated by the master to  
indicate the beginning of a data transfer on the bus. The  
master generates a START condition by pulling SDA from  
high to low while SCL is high (see Figure 6). A “repeated”  
START is sometimes used at the end of a data transfer  
(instead of a STOP) to indicate that the master will  
perform another operation.  
STOP Condition: Signal generated by the master to  
indicate the end of a data transfer on the bus. The master  
generates a STOP condition by transitioning SDA from  
low to high while SCL is high (see Figure 6). After the  
STOP is issued, the master releases the bus to its idle state.  
Acknowledge (ACK): When a device (either master  
or slave) is acting as a receiver, it must generate an  
acknowledge (ACK) on the SDA line after receiving every  
byte of data. The receiving device performs an ACK by  
pulling the SDA line low for an entire SCL period (see  
Figure 6). During the ACK clock cycle, the transmitting  
device must release SDA. A variation on the ACK signal is  
the “not acknowledge” (NACK). When the master device  
is acting as a receiver, it uses a NACK instead of an ACK  
after the last data byte to indicate that it is finished receiv-  
ing data. The master indicates a NACK by leaving the  
SDA line high during the ACK clock cycle.  
At power-up, the pointer defaults to the temperature  
register location. The temperature register can be read  
immediately without resetting the pointer.  
Changes to the pointer setting are accomplished as  
described in the 2-Wire Serial Data Bus section of this  
data sheet.  
2-Wire Serial Data Bus  
The DS75LV communicates over a standard bidirectional  
2-wire serial data bus that consists of a serial clock (SCL)  
signal and serial data (SDA) signal. The device interfaces  
to the bus via the SCL input pin and open-drain SDA I/O  
pin. All communication is MSb first.  
Slave Address: Every slave device on the bus has a  
unique 7-bit address that allows the master to access that  
device. The DS75LV’s 7-bit bus address is 1 0 0 1 A2 A1  
A0, where A2, A1, and A0 are user-selectable via the cor-  
responding input pins. The three address pins allow up  
to eight DS75LVs to be multi-dropped on the same bus.  
The following terminology is used to describe 2-wire  
communication:  
Master Device: Microprocessor/microcontroller that controls  
the slave devices on the bus. The master device generates  
the SCL signal and START and STOP conditions.  
Address Byte: The control byte is transmitted by the  
master and consists of the 7-bit slave address plus a  
read/write (R/W) bit (see Figure 7). If the master is going  
to read data from the slave device then R/W = 1, and if  
the master is going to write data to the slave device then  
R/W = 0.  
Slave: All devices on the bus other than the master. The  
DS75LV always functions as a slave.  
Bus Idle or Not Busy: Both SDA and SCL remain high.  
SDA is held high by a pullup resistor when the bus is idle,  
and SCL must either be forced high by the master (if the  
SCL output is push-pull) or pulled high by a pullup resistor  
(if the SCL output is open-drain).  
Pointer Byte: The pointer byte is used by the master to  
tell the DS75LV which register is going to be accessed  
during communication. The six MSbs of the pointer byte  
(see Figure 8) are always 0 and the two LSbs correspond  
to the desired register as shown in Table 5.  
Transmitter: A device (master or slave) that is sending  
data on the bus.  
Maxim Integrated  
9  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
SDA  
SCL  
START  
ACK (OR NACK)  
STOP  
CONDITION  
FROM RECEIVER  
CONDITION  
Figure 6. START, STOP, and ACK Signals  
BIT 7  
1
BIT 6  
BIT 5  
0
BIT 4  
1
BIT 3  
BIT 2  
A1  
BIT 1  
A0  
BIT 0  
0
A2  
R/W  
Figure 7. Address Byte  
BIT 7  
0
BIT 6  
0
BIT 5  
0
BIT 4  
0
BIT 3  
0
BIT 2  
0
BIT 1  
P1  
BIT 0  
P0  
Figure 8. Pointer Byte  
Writing to the DS75LV: To write to the DS75LV, the  
master must generate a START followed by an address  
byte containing the DS75LV bus address. The value of  
the R/W bit must be a 0, which indicates that a write is  
about to take place. The DS75LV responds with an ACK  
after receiving the address byte. The master then sends  
a pointer byte which tells the DS75LV which register is  
being written to. The DS75LV again responds with an  
ACK after receiving the pointer byte. Following this ACK  
the master device must immediately begin transmitting  
data to the DS75LV. When writing to the configuration  
register, the master must send one byte of data (see  
General 2-Wire Information  
● All data is transmitted MSb first over the 2-wire bus.  
● One bit of data is transmitted on the 2-wire bus each  
SCL period.  
● A pullup resistor is required on the SDA line and, when  
the bus is idle, both SDA and SCL must remain in a  
logic-high state.  
● All bus communication must be initiated with a START  
condition and terminated with a STOP condition.  
During a START or STOP is the only time SDA is  
allowed to change states while SCL is high. At all other  
times, changes on the SDA line can only occur when  
SCL is low: SDA must remain stable when SCL is high.  
Figure 9b), and when writing to the T or T  
registers  
OS  
HYST  
the master must send two bytes of data (see Figure 9c).  
After receiving each data byte, the DS75LV responds with  
an ACK, and the transaction is finished with a STOP from  
the master.  
● After every 8-bit (1-byte) transfer, the receiving device  
must answer with an ACK (or NACK), which takes one  
SCL period. Therefore, nine clocks are required for  
every one-byte data transfer.  
Maxim Integrated  
10  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Software POR: The soft power-on reset (POR) com-  
mand is 54h. The master sends a START followed by an  
address byte containing the DS75LV bus address. The  
R/W bit must be a 0. The DS75LV responds with an ACK.  
If the next byte is a 0x54, the DS75LV resets as if power  
had been cycled. No ACK is sent by the IC after the POR  
command is received.  
a NACK followed by a STOP after reading the first data  
byte in which case the transaction is the same as for a  
read from the configuration register.  
If the pointer is not already pointing to the desired register,  
the pointer must first be updated as shown in Figure 9d  
,
which shows a pointer update followed by a single-byte  
read. The value of the R/W bit in the initial address byte  
is a 0 (“write”) since the master is going to write a pointer  
byte to the DS75LV. After the DS75LV responds to the  
address byte with an ACK, the master sends a pointer byte  
that corresponds to the desired register. The master must  
then perform a repeated start followed by a standard one  
or two byte read sequence (with R/W =1) as described in  
the previous paragraph.  
Reading from the DS75LV: When reading from the  
DS75LV, if the pointer was already pointed to the desired  
register during a previous transaction, the read can be  
performed immediately without changing the pointer setting.  
In this case the master sends a START followed by an  
address byte containing the DS75LV bus address. The  
R/W bit must be a 1, which tells the DS75LV that a read  
is being performed. After the DS75LV sends an ACK in  
response to the address byte, the DS75LV begins trans-  
mitting the requested data on the next clock cycle. When  
reading from the configuration register, the DS75LV  
transmits one byte of data, after which the master must  
respond with a NACK followed by a STOP (see Figure  
Bus Timeout: The DS75LV has a bus timeout feature  
that prevents communication errors from leaving the IC  
in a state where SDA is held low disrupting other devices  
on the bus. If the DS75LV holds the SDA line low for a  
period of t  
, its bus interface automatically resets  
TIMEOUT  
and release the SDA line. Bus communication frequency  
must be fast enough to prevent a reset during normal  
operation. The bus timeout feature only applies to when  
the DS75LV is holding SDA low. Other devices can hold  
SDA low for an undefined period without causing the  
interface to reset.  
9e). For two-byte reads (i.e., from the Temperature, T  
OS  
or T  
register), the DS75LV transmits two bytes  
HYST  
of data, and the master must respond to the first data  
byte with an ACK and to the second byte with a NACK  
followed by a STOP (see Figure 9a). If only the most  
significant byte of data is needed, the master can issue  
Maxim Integrated  
11  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
A) READ 2 BYTES FROM THE TEMPERATURE, T , OR T  
OS  
REGISTER (CURRENT POINTER LOCATION)  
HYST  
SCL  
SDA  
S
1
0
0
1
A2 A1 A0  
R
A
D7 D6 D5 D4 D3 D2 D1 D0  
MS DATA BYTE  
A
D7 D6 D5 D4 D3 D2 D1 D0  
LS DATA BYTE  
N
P
START  
ADDRESS BYTE  
ACK  
ACK  
NACK STOP  
(MASTER)  
(DS75LV)  
(FROM DS75LV)  
(MASTER)  
(FROM DS75LV)  
B) WRITE TO THE CONFIGURATION REGISTER  
SCL  
SDA  
S
1
0
0
1
A2 A1 A0  
W
A
0
0
0
0
0
0
0
1
A
D7 D6 D5 D4 D3 D2 D1 D0  
DATA BYTE  
A
P
START  
ADDRESS BYTE  
ACK  
POINTER BYTE  
ACK  
ACK STOP  
(DS75LV)  
(DS75LV)  
(DS75LV)  
(FROM MASTER)  
C) WRITE TO THE T OR T  
OS  
REGISTER  
HYST  
SCL  
SDA  
S
1
0
0
1
A2 A1 A0  
W
A
0
0
0
0
0
0
P1 P0  
A
D7 D6 D5 D4 D3 D2 D1 D0  
MS DATA BYTE  
A
D7 D6 D5 D4 D3 D2 D1  
LS DATA BYTE  
A
P
START  
ADDRESS BYTE  
ACK  
POINTER BYTE  
ACK  
ACK  
ACK STOP  
(DS75LV)  
(DS75LV)  
(DS75LV)  
(FROM MASTER)  
(DS75LV)  
(FROM MASTER)  
D) READ SINGLE BYTE (NEW POINTER LOCATION)  
SCL  
SDA  
S
1
0
0
1
A2 A1 A0  
W
A
0
0
0
0
0
0
P1 P0  
A
S
1
0
0
1
A2 A1 A0  
R
A
D7 D6 D5 D4 D3 D2 D1 D0  
DATA BYTE  
N
P
START  
ADDRESS BYTE  
ACK  
POINTER BYTE  
ACK REPEAT ADDRESS BYTE  
(DS75LV) START  
ACK  
NACK STOP  
(MASTER)  
(DS75LV)  
(DS75LV)  
(FROM DS75LV)  
E) READ FROM THE CONFIGURATION REGISTER (CURRENT POINTER LOCATION)  
SCL  
SDA  
S
1
0
0
1
A2 A1 A0  
R
A
D7 D6 D5 D4 D3 D2 D1 D0  
N
P
START  
ADDRESS BYTE  
ACK  
(DS75LV)  
DATA BYTE  
(FROM DS75LV)  
NACK STOP  
(MASTER)  
Figure 9. 2-Wire Interface Timing  
Maxim Integrated  
12  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Ordering Information  
PART  
DS75LVS+  
TEMP RANGE  
-55°C to +125°C  
-55°C to +125°C  
-55°C to +125°C  
-55°C to +125°C  
TOP MARK  
DS75L*  
DS75L*  
DS75L  
PIN-PACKAGE  
8 SO  
DS75LVS+T&R  
DS75LVU+  
8 SO  
®
8 µSOP (µMAX )  
8 µSOP (µMAX)  
DS75LVU+T&R  
DS75L  
+Denotes a lead(Pb)-free/RoHS-compliant package.  
T&R = Tape and reel.  
*A “+” symbol is also marked on the package near the pin 1 indicator.  
Package Information  
For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”,  
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing  
pertains to the package regardless of RoHS status.  
PACKAGE TYPE  
8 SO  
PACKAGE CODE  
S8+2  
OUTLINE NO.  
21-0141  
LAND PATTERN NO.  
90-0096  
8 µMAX  
U8+1  
21-0036  
90-0092  
µMAX is a registered trademark of Maxim Integrated Products, Inc.  
Maxim Integrated  
13  
www.maximintegrated.com  
DS75LV  
Digital Thermometer and Thermostat  
Revision History  
REVISION REVISION  
PAGES  
CHANGED  
DESCRIPTION  
NUMBER  
DATE  
0
1
2
3
4
5
5/06  
Initial release  
11/06  
12/14  
4/15  
Changed the max conversion time for R1 and R0 in Table 4  
Updated Benefits and Features section  
8
1
Revised Electrical Characteristics, Table 3, and Ordering Information  
Updated rise and fall time of SCL and SDA in Electrical Characteristics table  
Added Thermistor Error typical specification  
2, 3, 8, 13  
3/16  
3
2
11/16  
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com.  
Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses  
are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits)  
shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance.  
©
Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.  
2016 Maxim Integrated Products, Inc.  
14  

相关型号:

DS75LX

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXS

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXS+

Analog Circuit, 1 Func, PDSO8, 0.150 INCH, LEAD FREE, SOP-8
MAXIM

DS75LXS+T&R

Analog Circuit, 1 Func, PDSO8, 0.150 INCH, LEAD FREE, SOP-8
MAXIM

DS75LXSR

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXST

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXU

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXU+

Analog Circuit, 1 Func, PDSO8, LEAD FREE, MICROSOP-8
MAXIM

DS75LXU+T&R

Analog Circuit, 1 Func, PDSO8, LEAD FREE, MICROSOP-8
MAXIM

DS75LXUR

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75LXUT

Digital Thermometer and Thermostat with Extended Addressing
MAXIM

DS75S

2.Wire Thermal Watchdog
DALLAS