MAX11801ETC/V+T [MAXIM]

Consumer Circuit, CMOS, PQCC12;
MAX11801ETC/V+T
型号: MAX11801ETC/V+T
厂家: MAXIM INTEGRATED PRODUCTS    MAXIM INTEGRATED PRODUCTS
描述:

Consumer Circuit, CMOS, PQCC12

控制器
文件: 总57页 (文件大小:894K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
19-4711; Rev 2; 3/10  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
General Description  
Features  
The MAX11800–MAX11803 low-power touch-screen con-  
trollers operate from a single supply of 1.70V to 3.6V, tar-  
geting power-sensitive applications such as handheld  
equipment. The devices contain a 12-bit SAR ADC and a  
multiplexer to interface with a resistive touch-screen  
panel. A digital serial interface provides communications.  
4-Wire Touch-Screen Interface  
X/Y Coordinate and Touch Pressure Measurement  
Ratiometric Measurement  
12-Bit SAR ADC  
Single 1.7V to 3.6V Supply  
The MAX11800–MAX11803 include digital preprocessing  
of the touch-screen measurements, reducing bus loading  
and application-processor resource requirements. The  
included smart interrupt function generator greatly  
reduces the frequency of interrupt servicing to the  
devices. The MAX11800–MAX11803 enter low-power  
modes automatically between conversions to save power,  
making the devices ideal for portable applications.  
Two Operating Modes—Direct and Autonomous  
Data Tagging Provides Measurement and Touch  
Event Information  
Data Filtering Provides Noise Reduction  
Aperture Mode† Provides Spatial Filtering  
Digital Processing Reduces Bus Activity and  
Interrupt Generation  
The MAX11800/MAX11801 offer two modes of operation:  
direct and autonomous. Direct mode allows the applica-  
tion processor to control all touch-screen controller activ-  
ity. Autonomous mode allows the MAX11800/MAX11801  
to control touch-screen activity, thereby freeing the  
application processor to perform other functions. In  
autonomous mode, the devices periodically scan the  
touch screen for touch events without requiring host-  
processor intervention. This can be used to reduce sys-  
tem power consumption. An on-chip FIFO is used during  
autonomous mode to store results and increase effective  
data throughput and lower system power.  
Programmable Touch-Detect Pullup Resistors  
Auto Power-Down Control for Low-Power  
Operation  
25MHz SPI Interface (MAX11800/MAX11802)  
400kHz I2C Interface (MAX11801/MAX11803)  
1.6mm x 2.1mm, 12-Pin WLP and 4mm x 4mm,  
12-Pin TQFN  
Low-Power Operation  
343µW at V  
= 1.7V, 34.4ksps  
= 3.3V, 34.4ksps  
DD  
DD  
888µW at V  
The MAX11800–MAX11803 support data-tagging,  
which records the type of measurement performed; X,  
Y, Z1, or Z2, and the type of touch event; initial touch,  
continuing touch, or touch release.  
ESD Protection  
4kV HBM  
8kV HBM (Xꢀ, X-, Yꢀ, Y-)  
1kV CDM  
200V MM  
The MAX11800/MAX11802 support the SPI™ serial bus.  
The MAX11801/MAX11803 support the I2C serial bus.  
The MAX11800–MAX11803 are available in 12-pin TQFN  
and 12-pin WLP packages, and are specified over the  
-40°C to +85°C (extended) and -40°C to +105°C (auto-  
motive) temperature ranges.  
Ordering Information  
PART  
TEMP RANGE  
-40°C to +85°C  
-40°C to +105°C  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +105°C  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +85°C  
PIN-PACKAGE  
12 TQFN-EP*  
12 TQFN-EP*  
12 WLP  
MAX11800ETC+  
MAX11800GTC/V+  
MAX11800EWC+T  
MAX11801ETC+  
MAX11801GTC/V+  
MAX11801EWC+T  
MAX11802ETC  
Applications  
Mobile Communication  
Devices  
POS Terminals  
12 TQFN-EP*  
12 TQFN-EP*  
12 WLP  
Handheld Games  
PDAs, GPS Receivers,  
Personal Navigation  
Devices, Media Players  
Automotive Center  
Consoles  
12 TQFN-EP*  
12 WLP  
MAX11802EWC+T  
MAX11803ETC  
Portable Instruments  
12 TQFN-EP*  
12 WLP  
Typical Operating Circuits and Pin Configurations appear  
at end of data sheet.  
MAX11803EWC+T  
*EP = Exposed pad.  
+Denotes a lead(Pb)-free/RoHS-compliant package.  
/V denotes an automotive qualified part.  
SPI is a trademark of Motorola, Inc.  
Patents pending.  
________________________________________________________________ Maxim Integrated Products  
1
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,  
or visit Maxim’s website at www.maxim-ic.com.  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
TABLE OF CONTENTS  
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
2
I C Timing Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
SPI Timing Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
Typical Operating Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
Functional Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
Detailed Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
Position Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
Pressure Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
Touch-Detect Modes and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
PUR and PUF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
Idle Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
Features Common to the MAX11800–MAX11803 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
Averaging Modes and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
Combined Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Data Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Low-Power Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Panel Setup, Measurement, and Scan Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Direct Conversion Mode Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Interrupt Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Panel Setup Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Panel Measurement Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Combined Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Auxiliary Measurement Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Autonomous Conversion Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31  
Measurement Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
Combined Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
Delayed Touch Detection During Mode Transitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
FIFO Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
Clearing FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
FIFO Data Block Readback Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
FIFO Data Word Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Block Readback Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Clearing Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Aperture Modes* and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Aperture Range Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
FIFO Aperture Criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
–MAX1803  
2
_______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
TABLE OF CONTENTS (continued)  
Applications Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
Using Aperture Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
Examples of Using Aperture Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36  
SPI Communication Sequence (MAX11800/MAX11802) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
SPI Configuration Register Write (MAX11800/MAX11802) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
SPI Configuration or Result Register Read (MAX11800/MAX11802) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39  
SPI Conversion Command (MAX11800/MAX11802) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
2
I C-Supported Sequence (MAX11801/MAX11803) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
2
I C Configuration Register Write (MAX11801/MAX11803) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
2
I C Configuration or Result Register Read (MAX11801/MAX11803) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
2
I C Conversion Command (MAX11801/MAX11803) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
Command and Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
User-Accessible Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
Status and Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43  
Data Readback Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44  
Autonomous Conversion Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44  
Direct Conversion Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44  
Panel Setup and Measurement Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46  
User Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47  
General Status Register (0x00) (Read Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47  
General Configuration Register (0x01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48  
Measurement Resolution Configuration Register (0x02) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48  
Measurement Averaging Configuration Register (0x03) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49  
ADC Sampling Time Configuration Register (0x04) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49  
Panel Setup Timing Configuration Register (0x05) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50  
Delayed Conversion Configuration Register (0x06) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50  
Touch-Detect Pullup Timing Configuration Register (0x07) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51  
Autonomous Mode Timing Configuration Register (0x08) (MAX11800/MAX11801) . . . . . . . . . . . . . . . . . . . . . . . .51  
Aperture Configuration Register (0x09) (MAX11800/MAX11801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52  
Auxiliary Measurement Configuration Register (0x0A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53  
Operating Mode Configuration Register (0x0B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54  
MAX11800/MAX11802 Typical Operating Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55  
MAX11801/MAX11803 Typical Operating Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55  
Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56  
Chip Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56  
Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56  
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57  
_______________________________________________________________________________________  
3
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
LIST OF FIGURES  
2
Figure 1. I C Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
Figure 2. SPI Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11  
Figure 3a. MAX11800/MAX11801 Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17  
Figure 3b. MAX11802/MAX11803 Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
Figure 4. Position Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
Figure 5. Pressure Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
Figure 6. Touch-Detection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21  
Figure 7. Touch-Detection Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22  
Figure 8. State Machine Transitions (Direct Conversion Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Figure 9. Continuous Interrupt Mode (Direct Conversion Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
Figure 10. Edge Interrupt Mode (Direct Conversion Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
Figure 11. Command and Measurement Flow (DCM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Figure 12. Panel Setup and Measurement Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
Figure 13. Combined Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30  
Figure 14. State Machine Transitions––Autonomous Conversion Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31  
Figure 15. Clear-on-Read Interrupt Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
Figure 16. Aperture Usage Example Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36  
Figure 17. SPI Single Configuration Register Write Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
Figure 18. SPI Multiple Configuration Register Write Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
Figure 19. SPI Single-Byte Register Read Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39  
Figure 20. SPI Multiple-Byte Register Read Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
Figure 21. SPI Conversion Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
–MAX1803  
2
Figure 22. I C Single Register Write Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
2
Figure 23. I C Multiple Register Write Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40  
2
Figure 24. I C Multiple Register Read Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
2
Figure 25. I C Streamlined Register Read Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
2
Figure 26. I C Conversion Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
4
_______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
LIST OF TABLES  
Table 1. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
Table 2. Operating Modes, Conditions, and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
Table 3. Summary of Physical Panel Settings for Supported Measurement Types . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
Table 4. Median Averaging Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Table 5. Data Word Structure (All Direct Conversion Modes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Table 6. Measurement and Event Tags (Continuous Interrupt Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
Table 7. Measurement and Event Tags (Edge Interrupt Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
Table 8. Panel Setup Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Table 9. Panel Measurement Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Table 10. FIFO Data Block Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
Table 11. FIFO Data Word Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Table 12. FIFO Data Measurement Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Table 13. FIFO Event Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Table 14. Readback and FIFO Contents with Aperture Mode Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37  
Table 15. Readback and FIFO Contents with Aperture Mode Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37  
Table 16. SPI Command and Data Format: 8 Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43  
2
Table 17. I C Command and Data Format: 8 Bits Plus ACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43  
Table 18. Status and Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44  
Table 19. FIFO Data Readback Command (Autonomous Mode Only––MAX11800/MAX11801) . . . . . . . . . . . . . . . .45  
Table 20. Data Readback Commands (Direct Mode Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45  
2
Table 21. I C Readback Register Settings Following Conversion Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45  
Table 22. Measurement Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46  
_______________________________________________________________________________________  
5
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Table 1. Terminology  
TERM  
DEFINITION  
Panel,  
Touch Screen,  
Touch Panel  
Resistive Touch Sensor: Panel, or touch screen, or touch panel are used interchangeably to denote the  
resistive touch sensor.  
Touch-Screen Controller: Devices attached to a touch screen that provide the interface between an  
application processor (AP) and touch screen.  
TSC  
X+  
X-  
X Position Positive I/O: Analog I/O from resistive touch screen. See Figure 4 for configuration and  
measurement details.  
X Position Negative I/O: Analog I/O from resistive touch screen. See Figure 4 for configuration and  
measurement details.  
Y Position Positive I/O: Analog I/O from resistive touch screen. See Figure 4 for configuration and measurement  
details.  
Y+  
Y-  
Y Position Negative I/O: Analog I/O from resistive touch screen. See Figure 4 for configuration and  
measurement details.  
Touch Resistance: Represents the resistance between the X and Y planes of a resistive touch screen during a  
touch event.  
R
TOUCH  
Z1  
Z1 Measurement: A resistive touch-screen measurement to determine the resistance between the two planes  
–MAX1803  
within the panel sensor during a touch event (R ). See Figure 5 for configuration and measurement details.  
TOUCH  
Z2 Measurement: A resistive touch-screen measurement to determine the resistance between the two planes  
within the panel sensor during a touch event (R ). See Figure 5 for configuration and measurement details.  
Z2  
TOUCH  
Auxiliary Input: Analog input to the MAX11800–MAX11803 that can be used to monitor external conditions  
such as battery voltage or temperature.  
AUX  
ADC  
AP  
Analog-to-Digital Converter: Circuit used to transform analog information into a form suitable for digital operations.  
Application Processor: An external microcontroller or microprocessor that interfaces to and controls the  
general operation of the MAX11800–MAX11803.  
Averaging Mode: The ability to average consecutive measurement results to reduce noise from switch  
bounce, power-supply ripple, and incomplete settling.  
AVG  
Median Averaging Filter: The MAF first removes the minimum and maximum samples before taking the  
average of the remaining sample set.  
MAF  
SAF  
TDM  
Straight Averaging Filter: The SAF takes the average of an entire sample set.  
Touch-Detect Mode: An untimed mode that monitors the panel for a touch using a user-selectable panel  
pullup resistor of either 50kor 100k.  
Direct Conversion Mode: A mode of operation in which the AP requests individual panel setup and  
conversion operations or automated combinations of measurements (X and Y, X and Y and Z1, or X and Y and  
Z1 and Z2). The AP maintains control over the initiation of panel setup, measurements, and the sampling  
DCM  
ACM  
Autonomous Conversion Mode: A mode of operation in which the MAX11800/MAX11801 idle in TDM until a  
touch event occurs. After a touch is detected, the MAX11800/MAX11801 begin an automated sequence of  
measurements determined by the user configuration registers.  
Panel Setup Command: User-programmable modes for the purpose of allowing the panel sufficient time to  
settle, prior to the start of measurements. PSU commands configure the on-chip multiplexer in preparation to  
perform either X, Y, Z1, or Z2 measurements. Durations can either be specified and managed by the  
MAX11800–MAX11803 (in ACM and DCM) or managed by the AP (in DCM).  
PSU  
PMC  
CMC  
Panel Measurement Command: Individual measurements of X or Y position and Z1 or Z2 pressure measurements.  
Combined Measurement Command: Combinations of PMCs (X and Y, X and Y and Z1, or X and Y and Z1 and  
Z2) offered by the MAX11800–MAX11803 and executed in series to reduce AP bus and interrupt activity.  
6
_______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Table 1. Terminology (continued)  
TERM  
DEFINITION  
First-In First-Out Memory: The MAX11800–MAX11803 contain a 1024-bit FIFO that is used to store conversion  
results when operating in autonomous conversion mode. FIFO depth indicates the number of words (16-bit  
quantity) in the FIFO.  
FIFO  
Scan: Generally, a single sequence of operations performed in DCM or ACM. The operations could include a  
panel setup operation, followed by a panel measurement operation, or a combined measurement operation.  
Scan  
Scan Block: Generally, a sequence of multiple operations performed in DCM or ACM. The operations could  
include panel-setup operations, panel-measurement operations, or combined measurement operations.  
Scan Block  
Timed Scan: A scan or scan block operation that uses the on-chip oscillator and timer. The timer is controlled  
through the configuration registers and represents an array of fixed (time) quantities that are user selectable  
(MAX11800/MAX11801).  
Timed Scan  
Untimed Scan Untimed Scan: A scan or scan block operation that is controlled by the AP. This only applies to DCM.  
Data Tag: Information appended to the end of an ADC conversion result. Tags indicate the type of measurement and  
touch status associated with each panel observation. See the definitions for ETAG and MTAG (also in Table 1).  
TAG  
ETAG  
MTAG  
Event Tag: Data tags indicating the panel touch status observed during a measurement.  
Measurement Tag: Data tag indicating the type of measurement read back by the AP (either X, Y, Z1, or Z2).  
Touch Interrupt Request: Active-low interrupt, indicating that a touch is present (CINT) or has been initiated  
(EINT) in DCM, or that new data is available in the FIFO in ACM.  
TIRQ  
EINT  
CINT  
Edge Interrupt Mode: Indicates, through TIRQ, that a touch has been initiated (EINT) in DCM. The duration that  
TIRQ is low is user programmable.  
Continuous Interrupt Mode: Indicates, through TIRQ, that a touch is present (CINT) in DCM. TIRQ goes low to  
indicate the presence of a touch and stays low until the touch event ceases.  
Clear-on-Read Interrupt Mode: Used in ACM only. TIRQ goes low to indicate the presence of new FIFO data. The  
interrupt is cleared when the data is read by the AP (MAX11800/MAX11801).  
CORINT  
APER  
Aperture Mode: Available in ACM only. Reduces data writes to the FIFO by spatially filtering measurement data.  
Continuous Bit: An option in DCM to return the MAX11800–MAX11803 to a panel setup (wait) mode (PSU) after a  
conversion, rather than a return to TDM (recommended only for applications with very long panel settling times and  
request controlling their own averaging). The continuous bit resides in bit 0 (R0) of the PSU and PMC registers.  
CONT  
LPM  
Low-Power Mode: An idle mode used in DCM/EINT or ACM modes, when a touch is detected at the conclusion of  
the last measurement. This indicates a new measurement needs to be requested or scheduled (the touch-detect  
pullup is not engaged to save power).  
Pullup Rough: A fast pullup mode, which uses the main X+ switch in parallel with the on-chip resistive pullup  
PUR  
PUF  
(50kΩ/100kΩ) to quickly slew the touch panel capacitances. R  
10Ω typical.  
PUR  
Pullup Fine: A slow (fine) pullup mode, which uses the on-chip resistive pullup to slew the touch-panel  
capacitances to their final values (R = 50kΩ or 100kΩ) typical and is required for all applications.  
PUF  
Successive Approximation Register ADC: An analog-to-digital converter that converts a continuous analog  
waveform into a discrete digital representation through a binary search through all possible quantization levels  
before finally converging upon a digital output for each conversion.  
SAR ADC  
Inter-Integrated Circuit: A multimaster serial computer bus that is used to attach low-speed peripherals to other  
components using two bidirectional open-drain lines, serial data (SDA) and serial clock (SCL), pulled up with  
resistors.  
2
I C  
Serial Peripheral Interface: A serial interface in which a master device supplies clock pulses to exchange data  
serially with a slave over two data wires (master-slave and slave-master).  
SPI  
_______________________________________________________________________________________  
7
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
ABSOLUTE MAXIMUM RATINGS  
DD  
V
to GND...........................................................-0.3V to +4.0V  
Operating Temperature Ranges  
X+, X-, Y+, Y-, AUX, TIRQ to GND ........................-0.3V to +4.0V  
SCL, CLK, SDA, DIN, A0, CS, A1, DOUT to GND.-0.3V to +4.0V  
Maximum Current into Any Pin ......................................... 50mA  
MAX1180_E_ _..................................................-40°C to +85°C  
MAX1180_G_ _...............................................-40°C to +105°C  
Storage Temperature Range.............................-65°C to +150°C  
Junction Temperature......................................................+150°C  
Soldering Temperature (reflow) .......................................+260°C  
Lead Temperature (soldering, 10s) .................................+300°C  
Continuous Power Dissipation (T = +70°C)  
A
12-Pin TQFN (derate 24.4mW/°C above +70°C) ....1951.2mW  
12-Pin WLP (derate 6.5mW/°C above +70°C) ..........518.8mW  
Note 1: All WLP devices are 100% production tested at T = +25°C. Specifications over temperature limits are guaranteed by  
A
design and characterization.  
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional  
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to  
absolute maximum rating conditions for extended periods may affect device reliability.  
ELECTRICAL CHARACTERISTICS  
(V  
= 1.7V to 3.6V, T = -40°C to +85°C (MAX11800E–MAX11803E), T = -40°C to +105°C (MAX11800G/MAX11801G), unless oth-  
A
A
DD  
erwise noted. Typical values are at T = +25°C and V = 3.3V, unless otherwise noted.)  
A
DD  
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
ADC  
ADC Resolution  
Differential Nonlinearity  
Integral Nonlinearity  
Offset Error  
No missing codes  
12-bit resolution  
12-bit resolution  
10  
11  
1.5  
1.5  
2
Bits  
LSB  
LSB  
LSB  
LSB  
ksps  
DNL  
INL  
–MAX1803  
Gain Error  
4
Throughput  
105  
TOUCH SENSORS (Xꢀ, X-, Yꢀ, Y-, AUX)  
V
V
= 1.7V  
= 3.3V  
7
5
12  
10  
50  
DD  
DD  
Switch On-Resistance  
Ω
Switch Driver Current  
Input Voltage Range  
mA  
V
0
V
DD  
POWER SUPPLY (V  
)
DD  
Supply Voltage  
V
1.7  
3.6  
1
V
DD  
1.7V  
3.6V  
Power-down mode. All digital  
inputs static.  
2
TDM. All digital inputs static.  
Does not include panel currents 3.6V  
when touched.  
7
Timed LPM. All digital inputs  
1.7V  
Supply Current  
μA  
9
20  
40  
static. Does not include panel  
3.3V  
16  
currents when touched.  
1.7V  
3.3V  
1.7V  
3.3V  
1.7V  
3.3V  
1.7V  
3.3V  
216  
273  
202  
269  
367  
901  
343  
888  
400  
550  
400  
550  
AUX conversions at 34.4ksps  
equivalent rate, SPI  
AUX conversions at 34.4ksps  
2
equivalent rate, I C  
AUX conversions at 34.4ksps  
equivalent rate, SPI  
Power Consumption  
μW  
AUX conversions at 34.4ksps  
2
equivalent rate, I C  
8
_______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
ELECTRICAL CHARACTERISTICS (continued)  
(V  
= 1.7V to 3.6V, T = -40°C to +85°C (MAX11800E–MAX11803E), T = -40°C to +105°C (MAX11800G/MAX11801G), unless oth-  
A
A
DD  
erwise noted. Typical values are at T = +25°C and V = 3.3V, unless otherwise noted.)  
A
DD  
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
DIGITAL INPUTS (SDA, DIN, SCL, CLK, A0, CS, A1)  
0.7 x  
Input Logic-High Voltage  
V
V
IH  
V
DD  
0.3 x  
Input Logic-Low Voltage  
Input Leakage Current  
Input Hysteresis  
V
V
μA  
V
IL  
V
DD  
I
V
= 0V or V  
DD  
-1  
+1  
IN  
IN  
0.5 x  
V
HYS  
V
DD  
Input Capacitance  
6
pF  
DIGITAL OUTPUTS (SDA, DOUT, TIRQ)  
0.9 x  
DOUT, I  
= 1mA  
SOURCE  
V
DD  
Output Logic-High  
V
V
OH  
0.9 x  
TIRQ, CMOS configuration, I  
= 1mA  
SOURCE  
V
DD  
Output Logic-Low—TIRQ, DOUT  
Output Logic-Low—SDA  
TIRQ Pullup Resistor  
V
V
I
I
= 1mA  
= 3mA  
0.4  
0.4  
V
V
OL  
OL  
SINK  
SINK  
125  
kΩ  
2
I C TIMING CHARACTERISTICS  
(V  
= 1.7V to 3.6V, T = -40°C to +85°C (MAX11801E and MAX11803E), T = -40°C to +105°C (MAX11801G), unless otherwise  
A
A
DD  
noted. Typical values are at T = +25°C and V  
= 3.3V, unless otherwise noted. See Figure 1.)  
A
DD  
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
Serial-Clock Frequency  
f
0
400  
kHz  
SCL  
Bus free time between STOP and START  
condition  
Bus Free Time  
t
1.3  
0.6  
μs  
μs  
BUF  
After this period, the first clock pulse is  
generated  
Hold Time for START Condition  
t
t
HD;STA  
SCL Pulse-Width Low  
SCL Pulse-Width High  
t
1.3  
0.6  
μs  
μs  
LOW  
t
HIGH  
Setup Time for Repeated START  
(Sr) Condition  
0.6  
μs  
SU;STA  
Data Hold Time  
Data Setup Time  
t
0
900  
ns  
ns  
HD;DAT  
t
100  
SU;DAT  
20 +  
C /10  
B
SDA and SCL Rise/Fall Time  
t
t
Receiving  
300  
250  
ns  
R, F  
20 +  
C /10  
B
SDA and SCL Fall Time  
t
Transmitting  
ns  
μs  
pF  
ns  
TF  
Setup Time for STOP Condition  
Bus Capacitance Allowed  
Pulse Width of Suppressed Spike  
t
0.6  
10  
10  
SU;STO  
V
V
= 1.7V to 2.7V  
= 2.7V to 3.6V  
100  
400  
50  
DD  
DD  
C
B
t
SP  
_______________________________________________________________________________________  
9
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
SPI TIMING CHARACTERISTICS  
(V  
= 1.7V to 3.6V, T = -40°C to +85°C (MAX11800E and MAX11802E), T = -40°C to +105°C (MAX11800G), unless otherwise  
DD  
A
A
noted. Typical values are at T = +25°C and V  
= 3.3V, unless otherwise noted. See Figure 2.)  
A
DD  
PARAMETER  
CLK Frequency  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
MHz  
ns  
f
25  
CLK  
CLK Period  
t
40  
18  
18  
18  
CP  
CLK Pulse-Width High  
CLK Pulse-Width Low  
CS Low to 1st CLK Rise Setup  
t
ns  
CH  
t
ns  
CL  
t
ns  
CSS0  
To prevent a 0th CLK read from being taken  
as a 1st read in a free-running application  
CS Low After 0th CLK Rise Hold  
t
0
18  
0
ns  
ns  
ns  
CSH0  
To prevent a 17th CLK read from being  
recognized by the device in a free-running  
application  
CS High to 17th CLK Setup  
t
CSS1  
CS High After 16th CLK Falling  
Edge Hold  
t
CSH1  
CS Pulse-Width High  
DIN to CLK Setup  
DIN Hold After CLK  
t
18  
25  
0
ns  
ns  
ns  
CSW  
–MAX1803  
t
DS  
DH  
t
DOUT Transition Valid After CLK  
Rise  
t
Output transition time  
Output hold time  
25  
ns  
ns  
DOT  
DOUT Remains Valid After CLK  
Rise  
t
3
DOH  
DOUT Valid Before CLK Rise  
t
t
= t - t  
CP DOT  
10  
ns  
ns  
DO1  
DO1  
CS Rise to DOUT Disable  
t
C
= 20pF  
40  
25  
DOD  
LOAD  
C
= 20pF. Minimum = hold time with  
LOAD  
regard to 8thCLK read. Maximum =  
CLK Rise to DOUT Enable  
t
3
ns  
DOE  
transition time with regard to 8th CLK read.  
t
F
SDA  
SCL  
t
BUF  
t
t
SP  
t
SU;DAT  
R
t
HD;STA  
t
LOW  
t
HIGH  
t
t
HD;STA  
SU;STO  
t
SU;STA  
t
t
HD;DAT  
F
S
P
S
Sr  
Figure 1. I2C Timing Diagram  
10 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
t
DS  
t
CP  
t
t
SCH1  
CSH0  
t
DH  
t
t
CSW  
CSS0  
t
CH  
CS  
CLK  
t
CL  
t
CSS1  
8
9
16  
1
0
DIN  
W
X
A6  
A5  
A4  
A3  
A2  
A1  
D7  
D3  
D1  
D0  
A0  
D6  
D5  
D4  
D2  
HIGH-Z  
SPI WRITE OPERATION  
DOUT  
t
DS  
t
CP  
t
DOH  
t
DO0  
t
DH  
t
CSS0  
t
DOE  
t
CH  
CS  
CLK  
t
DO1  
t
CL  
8
9
16  
1
DIN  
A5  
A4  
A3  
A1  
A6  
A2  
A0  
X
X
X
X
X
R
X
X
X
X
HIGH-Z  
HIGH-Z  
DOUT  
D7  
D5  
D2  
D1  
D0  
D6  
D4  
D3  
SPI READ OPERATION  
Figure 2. SPI Timing Diagram  
______________________________________________________________________________________ 11  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Typical Operating Characteristics  
(V  
DD  
= 1.8V at T = -40°C to +85°C (T = -40°C, T = 0°C, T = +25°C, and T = +85°C), 12-bit mode, all measurements using  
A A A A A  
noncontinuous AUX input. SPI = 10MHz and I2C = 400kHz, unless otherwise noted. Resistive touch-screen panel (X+ to X- = 608Ω,  
Y+ to Y- = 371Ω).)  
AVERAGE SUPPLY CURRENT  
vs. SAMPLING RATE  
AVERAGE SUPPLY CURRENT  
vs. SAMPLING RATE  
AVERAGE SUPPLY CURRENT  
vs. SAMPLING RATE  
5
4
3
2
1
0
5
4
3
2
1
0
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
AUTONOMOUS MODE  
DIRECT CONTINUOUS  
INTERRUPT MODE  
DIRECT EDGE  
INTERRUPT MODE  
DATA TAKEN WITH  
cps = COORDINATES  
RESISTIVE TOUCH  
PER SECOND  
cps = COORDINATES PER SECOND  
cps = COORDINATES PER SECOND  
SENSOR  
0
20 40 60 80 100 120 140 160 180 200  
SAMPLING RATE (cps)  
0
20 40 60 80 100 120 140 160 180 200  
SAMPLING RATE (cps)  
0
20 40 60 80 100 120 140 160 180 200  
SAMPLING RATE (cps)  
SUPPLY CURRENT IN POWER-DOWN  
vs. TEMPERATURE  
SWITCH RESISTANCE  
vs. SUPPLY VOLTAGE  
SWITCH RESISTANCE  
vs. TEMPERATURE  
–MAX1803  
8
7
6
5
4
3
7
0.40  
0.36  
0.32  
0.28  
0.24  
0.20  
0.16  
0.12  
0.08  
0.04  
0
Y+  
X+  
6
5
4
3
2
1
Y+  
Y-  
X+  
Y-  
X-  
X-  
1.6  
2.0  
2.4  
2.8  
(V)  
3.2  
3.6  
-40  
-15  
10  
35  
60  
85  
-40  
-15  
10  
35  
60  
85  
V
TEMPERATURE (NC)  
TEMPERATURE (NC)  
DD  
CHANGE IN ADC GAIN  
vs. TEMPERATURE  
CHANGE IN ADC OFFSET  
vs. TEMPERATURE  
4
3
4
3
2
1
0
2
1
0
-1  
-2  
-3  
-4  
-1  
-2  
-3  
-4  
-40  
-10  
20  
50  
80  
110  
-40  
-10  
20  
50  
80  
110  
TEMPERATURE (NC)  
TEMPERATURE (NC)  
12 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Typical Operating Characteristics (continued)  
(V  
DD  
= 1.8V at T = -40°C to +85°C (T = -40°C, T = 0°C, T = +25°C, and T = +85°C), 12-bit mode, all measurements using  
A A A A A  
noncontinuous AUX input. SPI = 10MHz and I2C = 400kHz, unless otherwise noted. Resistive touch-screen panel (X+ to X- = 608Ω,  
Y+ to Y- = 371Ω).)  
AVERAGE SUPPLY CURRENT  
vs. SAMPLING RATE  
AVERAGE SUPPLY CURRENT  
vs. SAMPLING RATE  
INTERNAL OSCILLATOR CLOCK  
FREQUENCY vs. TEMPERATURE  
120  
100  
80  
60  
40  
20  
0
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0
2.08  
2.06  
2.04  
2.02  
2.00  
1.98  
1.96  
1.94  
1.92  
1.90  
DIRECT CONVERSION  
MODE—AUXILIARY INPUT  
AUXILIARY INPUT DATA  
SAMPLED AT 1ksps AND  
2ksps WITH EIGHT AND  
16 SAMPLES  
AVERAGING  
ENABLED  
V
= 3.0V  
DD  
V
= 1.8V  
DD  
V
DD  
= 3.6V  
sps = SAMPLES PER SECOND  
ksps = KILO-SAMPLES PER SECOND  
8
16  
24  
32  
0
20 40 60 80 100 120 140 160 180 200  
SAMPLING RATE (sps)  
-40  
-15  
10  
35  
60  
85  
EQUIVALENT SAMPLING RATE (ksps)  
TEMPERATURE (NC)  
INTERNAL OSCILLATOR CLOCK  
FREQUENCY vs. SUPPLY VOLTAGE  
POWER CONSUMPTION  
vs. SAMPLE RATE  
2.08  
2.06  
2.04  
2.02  
2.00  
1.98  
1.96  
1.94  
1.92  
1.90  
160  
140  
120  
100  
80  
DATA TAKEN WITH  
RESISTIVE TOUCH SENSOR  
AUTONOMOUS MODE  
DIRECT CONTINUOUS MODE  
60  
cps = COORDINATES  
PER SECOND  
40  
20  
DIRECT EDGE MODE  
50  
0
1.8  
2.4  
3.0  
3.6  
0
100  
150  
200  
V
(V)  
SAMPLE RATE (cps)  
DD  
______________________________________________________________________________________ 13  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Pin Description  
PIN  
NAME  
FUNCTION  
MAX11800/MAX11802  
MAX11801/MAX11803  
TQFN  
1
WLP  
A4  
B4  
B3  
C4  
C3  
C2  
C1  
B1  
A1  
B2  
A2  
A3  
TQFN  
1
WLP  
A4  
B4  
B3  
C4  
C3  
C2  
—-  
X+  
X+ Channel Input/Output  
2
2
V
Power Supply. Bypass V to GND with a 1μF capacitor.  
DD  
DD  
3
3
GND  
X-  
Ground  
4
4
X- Channel Input/Output  
Y- Channel Input/Output  
5
5
Y-  
6
6
TIRQ  
DIN  
CLK  
CS  
Active-Low Touch Interrupt Output  
SPI Serial Data Input  
SPI Serial Data Clock Input  
SPI Chip-Select Input  
SPI Data Output  
7
11  
12  
7
8
9
10  
11  
12  
EP  
DOUT  
AUX  
Y+  
A2  
A3  
C1  
B1  
A1  
B2  
Auxiliary Input  
Y+ Channel Input/Output  
–MAX1803  
2
SDA  
SCL  
A0  
I C Serial Data Bus Input/Output  
2
8
I C Serial Data Clock Input  
2
9
I C Address Input Bit 0  
2
10  
EP  
A1  
I C Address Input Bit 1  
EP  
Exposed Pad. Connected to ground.  
14 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Functional Diagrams  
POWER  
AND  
BIAS  
MAX11800/MAX11801  
V
DD  
AUX  
DOUT (A1)  
SERIAL INTERFACE  
PHYSICAL LAYER  
(ANALOG INTERFACE)  
X+  
X-  
Y+  
Y-  
CS (A0)  
MUX  
SAR  
ADC  
CLK (SCL)  
DIN (SDA)  
TOUCH-  
SCREEN  
INTERFACE  
LOGIC  
CORE  
SIF  
PHY  
AUTONOMOUS  
MODE ENGINE  
INTERNAL  
CLOCK  
V
DD  
INTERRUPT  
GENERATION  
ENGINE  
FIFO  
TIRQ  
GND  
POWER  
AND  
BIAS  
MAX11802/MAX11803  
V
DD  
AUX  
DOUT (A1)  
SERIAL INTERFACE  
PHYSICAL LAYER  
(ANALOG INTERFACE)  
X+  
X-  
Y+  
Y-  
MUX  
SAR  
ADC  
CS (A0)  
TOUCH-  
SCREEN  
INTERFACE  
LOGIC  
CORE  
SIF  
PHY  
CLK (SCL)  
DIN (SDA)  
TIRQ  
INTERNAL  
CLOCK  
V
DD  
INTERRUPT  
GENERATION  
ENGINE  
GND  
______________________________________________________________________________________ 15  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
User-programmable acquisition modes  
Programmable interrupt output drive  
25MHz SPI interface (MAX11800/MAX11802)  
Detailed Description  
The MAX11800–MAX11803 contain standard features  
found in a typical resistive touch-screen controller as  
well as advanced features. Standard features included  
in the MAX11800–MAX11803 are:  
The MAX11800–MAX11803 operate in one of two top-  
level modes: direct conversion mode (DCM) or  
autonomous conversion mode (ACM). Direct conversion  
mode requires the AP to initiate all activity to and from  
the MAX11800–MAX11803. DCM is the operating mode  
that most standard resistive touch-screen controllers  
use. ACM allows the MAX11800/MAX11801 to perform  
measurements automatically and inform the AP when  
they are complete, reducing data transfers on the serial  
bus as well as generating fewer interrupt requests. The  
MAX11800/MAX11801 can operate in the standard  
mode that is familiar to users, or in the advanced fea-  
tures mode to provide additional flexibility.  
4-wire touch-screen interface  
X/Y coordinate measurement  
Touch pressure measurement  
Direct conversion operation—requires direct AP  
involvement  
Single commands—AP initiates all activity one com-  
mand at a time  
Ratiometric measurement  
12-bit SAR ADC  
Single 1.8V to 3.3V supply  
Programmable touch-detect pullup—50kΩ or  
100kΩ  
Auto power-down control for low-power operation  
400kHz I2C interface (MAX11801/MAX11803)  
Both DCM and ACM support averaging, data tagging,  
and combined commands. Certain commands and  
operations are only available in DCM, while others are  
only available in ACM. See Figures 3a and 3b and  
Table 2 for details.  
–MAX1803  
Position Measurements  
Position measurements determine either the X or Y  
coordinates of the point of contact on the panel sensor.  
Allow adequate time for the panel to settle when switch-  
ing between X and Y measurements. Figure 4 shows  
the physical setup of the panel when performing posi-  
tion measurements.  
Advanced features found in the MAX11800–MAX11803  
include:  
Autonomous conversion operation—minimal AP  
involvement (MAX11800/MAX11801)  
On-chip FIFO—buffers up to 16 consecutive mea-  
surements (MAX11800/MAX11801)  
The element R  
represents the resistance between  
TOUCH  
Data tagging—records measurement and touch-  
the X and Y planes of the panel sensor. R  
does  
TOUCH  
event information  
not contribute to the error when performing position mea-  
surements. R  
required between each valid measurement.  
Filtering—reduces noise using straight or median  
averaging  
affects the panel settling time  
TOUCH  
Aperture mode—provides spatial filtering  
(MAX11800/MAX11801)  
The panel end-to-end resistance in the direction of  
measurement determines the power applied across the  
panel. The panel dissipates power in the X elements  
when performing an X direction measurement and dis-  
sipates power in the Y elements when performing a Y  
direction measurement.  
Combined commands—multiple operations per-  
formed with a single AP command  
Digital processing to reduce serial bus activity  
Digital processing to reduce interrupt generation  
16 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
MAX11800  
MAX11801  
SETUP  
REGISTERS  
SETUP  
REGISTERS  
OPERATION MODES  
DIRECT CONVERSION  
(DCM)  
OPERATION  
MODE  
AUTONOMOUS CONVERSION  
(ACM)  
REGISTER 0x0B  
REGISTER 0x0B  
REGISTER 0x05  
REGISTER 0x6x  
REGISTER 0x05  
REGISTER 0x6x*  
PANEL SETUP COMMANDS  
(PSU)  
PANEL SETUP COMMANDS  
(PSU)  
PANEL MEASUREMENT  
COMMANDS (PMC)  
PANEL MEASUREMENT  
COMMANDS (PMC)  
REGISTER 0x7x  
REGISTER 0x7x  
REGISTER 0x0A  
REGISTER 0x7x*  
REGISTER 0x7x*  
COMMANDS  
PANEL COMBINED COMMANDS  
(CMC)  
PANEL COMBINED COMMANDS  
(CMC)  
AUX MEASUREMENT  
COMMANDS (AMC)  
N/A  
X, Y, Z1, Z2  
MEASUREMENTS  
X, Y, Z1, Z2  
MEASUREMENTS  
REGISTER 0x0B  
REGISTER 0x0B  
MEASUREMENT  
TYPES  
REGISTER 0x03  
REGISTER 0x0B  
REGISTER 0x03  
REGISTER 0x0B  
AVERAGING MEASUREMENTS  
AVERAGING MEASUREMENTS  
EDGE INTERRUPT MODE  
(EINT)  
N/A  
N/A  
REGISTER 0x01  
REGISTER 0x01  
CONTINUOUS INTERRUPT MODE  
(CINT)  
INTERRUPT  
TYPES  
CLEAR-ON-READ INTERRUPT  
(CORINT)  
N/A  
EVENT TAG (ETAG)  
(IF CONT = 1, NO FIFO)  
EVENT TAG (ETAG)  
(USES FIFO)  
DATA TAGGING  
TYPES  
MEASUREMENT TAG (MTAG)  
(IF CONT = 1, NO FIFO)  
MEASUREMENT TAG (MTAG)  
(USES FIFO)  
REGISTER 0x09  
REGISTER 0x01  
N/A  
APERTURE  
TIRQ  
APERTURE SETTINGS  
TIRQ CONFIGURATION  
REGISTER 0x01  
TIRQ CONFIGURATION  
REGISTER 0x02  
REGISTER 0x04  
REGISTER 0x06  
REGISTER 0x02  
REGISTER 0x04  
REGISTER 0x06  
ADC RESOLUTION  
AND TIMING  
ADC RESOLUTION  
AND TIMING  
ADC  
REGISTER 0x07  
REGISTER 0x08  
REGISTER 0x07  
PUR AND PUF TIMING  
N/A  
TDM TIMING  
AUTO TIMING  
PUR AND PUF TIMING  
TINIT AND SCANP TIMING  
*THESE REGISTERS CANNOT BE ALTERED WHEN AUTONOMOUS MODE IS ACTIVE. THEY SHOULD BE INITIALIZED BEFORE AUTONOMOUS MODE IS ACTIVATED.  
Figure 3a. MAX11800/MAX11801 Operation Modes  
______________________________________________________________________________________ 17  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
MAX11802  
MAX11803  
OPERATION MODES  
SETUP  
REGISTERS  
REGISTER 0x05  
REGISTER 0x6x  
PANEL SETUP COMMANDS  
(PSU)  
PANEL MEASUREMENT  
COMMANDS (PMC)  
REGISTER 0x7x  
REGISTER 0x7x  
REGISTER 0x0A  
COMMANDS  
PANEL COMBINED COMMANDS  
(CMC)  
AUX MEASUREMENT  
COMMANDS (AMC)  
X, Y, Z1, Z2  
MEASUREMENTS  
REGISTER 0x0B  
8
MEASUREMENT  
TYPES  
REGISTER 0x03  
REGISTER 0x0B  
AVERAGING MEASUREMENTS  
EDGE INTERRUPT MODE  
(EINT)  
REGISTER 0x01  
REGISTER 0x01  
INTERRUPT  
TYPES  
CONTINUOUS INTERRUPT MODE  
(CINT)  
EVENT TAG (ETAG)  
DATA TAGGING  
TYPES  
MEASUREMENT TAG (MTAG)  
REGISTER 0x01  
TIRQ CONFIGURATION  
TIRQ  
REGISTER 0x02  
REGISTER 0x04  
REGISTER 0x06  
ADC RESOLUTION  
AND TIMING  
ADC  
PUR AND PUF TIMING  
TDM TIMING  
REGISTER 0x07  
Figure 3b. MAX11802/MAX11803 Operation Modes  
18 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Table 2. Operating Modes, Conditions, and Options  
OPERATION  
MODE  
PUR  
PUF  
X, Y,  
Z1, Z2  
COR  
INT  
PSU PMC CMC TDM LPM AVG FIFO APER  
CONT MTAG ETAG  
EINT CINT  
DCM  
MAX11800– Yes Yes Yes Yes  
No  
Yes  
No  
No  
Yes  
Yes  
Yes2  
Yes2  
Yes  
Yes  
Yes  
No  
MAX11803  
ACM  
MAX11800/  
MAX11801  
Yes1 Yes1 Yes1 Yes Yes Yes Yes  
No Yes3 No Yes3 No  
No  
Yes  
No  
Yes  
No  
No  
No  
Yes  
No  
Yes  
No  
Yes  
No  
No  
No  
No  
No  
Yes  
No  
AUX  
1
2
In ACM, the choices are limited to X and Y scan, or X and Y and Z1 scan, or X and Y and Z1 and Z2 scan.  
In DCM, each ADC conversion is tagged with MTAG and ETAG only when the continuous bit is set (CONT = 1). DCM does not use  
the FIFO and, therefore, the AP should request the data at the end of the conversion cycle.  
3
A separate configuration register for delay time, sampling time, averaging, and ADC resolution settings configures the AUX input.  
Pressure Measurements  
X
Z
2
Z
1
⎞ ⎛  
Z1 and Z2 measurements determine the resistance  
between the two planes within the panel sensor during  
POSITION  
R
= R  
1  
⎟ ⎜  
⎠ ⎝  
TOUCH  
XPLATE  
N
2 BITX  
a touch (R  
). Depending on the known physical  
TOUCH  
properties of the panel, one of two equations extract the  
value of R , providing information about the pres-  
If only a Z1 measurement is available, compute  
R as follows:  
TOUCH  
TOUCH  
sure and area of the touch applied to the panel. Allow  
adequate time for the panel to settle when switching  
between position and pressure measurements. Figure 5  
shows the physical setup of the panel when performing  
pressure measurements.  
N
R
X
BITX  
2
BITZ  
Y
⎞ ⎛  
XPLATE POSITION  
POSITION  
N
R
=
1 R  
1−  
TOUCH  
⎟ ⎜  
⎠ ⎝  
YPLATE ⎜  
N
2
Z
2 BITY  
1
The power applied across the panel during pressure  
measurements is greatly dependent on R and  
Z1 and Z2 measurements allow observation of the volt-  
TOUCH  
age on either side of the effective R  
resistance.  
TOUCH  
the physical position of the touch. The maximum power  
dissipation in the panel during a pressure measurement  
With both Z1 and Z2 measurements available, compute  
is approximately P = V 2/R  
. This maximum  
Z
DD  
TOUCH  
R
as follows:  
TOUCH  
power dissipation condition is observed when the point  
of contact is in the top left corner of the panel sensor.  
ADC  
INPUT  
V
DD  
Y+  
Y+  
V
DD  
V
DD  
Y+  
Y+  
PANEL  
PANEL  
PANEL  
PANEL  
R
R
TOUCH  
TOUCH  
R
R
TOUCH  
TOUCH  
ADC  
INPUT  
Y-  
Y-  
Y-  
Y-  
X-  
X+  
X-  
X+  
X-  
X+  
X-  
X+  
ADC  
INPUT  
ADC  
INPUT  
V
DD  
X POSITION MEASUREMENT  
Y POSITION MEASUREMENT  
Z1 PRESSURE MEASUREMENT  
Z2 PRESSURE MEASUREMENT  
Figure 4. Position Measurements  
Figure 5. Pressure Measurements  
______________________________________________________________________________________ 19  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
The planar end-to-end resistance included in the cur-  
rent path is minimal at this location. Keep the averaging  
and panel settling durations to the minimum required  
by the application when pressure measurements are  
required. Table 3 summarizes the physical panel set-  
tings for supported measurement types.  
a touch is detected. The YMSW and TSW transistors  
are on, and the XPSW and PSW transistors are off. With  
no touch present, the Y- input of the TSC is at ground  
and the X+ input is at V  
- V , where V  
is the  
TN  
DD  
TN  
threshold voltage of the TSW nMOS device. This is a  
low-power mode in which no current is consumed until  
a panel touch occurs. When a touch is present on the  
panel, the touch-screen controller (TSC) X+ input is  
pulled low by the touch panel plate resistance and the  
YMSW transistor. This causes TOUCH to assume a  
logic high and the MAX11800–MAX11803 either issue  
the TIRQ interrupt for direct conversion modes or begin  
self-timed scans for autonomous conversion mode.  
Touch-Detect Modes and Options  
Figure 6 shows the internal circuitry in the  
MAX11800–MAX11803 used to detect the presence of  
a touch on the panel. The selection of the pullup resis-  
tance value (R  
= touch-detect resistance) and the  
TD  
durations of the rough pullup interval (PUR = low-  
impedance pullup) and fine pullup interval (PUF = high-  
impedance pullup) are user-defined.  
The value of the user-defined R  
depends on the  
TD  
characteristics of the panel. To ensure reliable detec-  
tion values, worst-case panel resistance must be  
The MAX11800–MAX11803 revert to the low-power  
panel setup when placed in touch-detect mode (TDM).  
Figure 6 shows the active panel drive switches (YMSW  
and XPSW are omitted for simplicity). TSW is a dedicat-  
ed pullup switch used in TDM. TSW is also used during  
PUF and TDM. XPSW is activated during PUR periods.  
TDRSEL allows the selection of an internal pullup resis-  
tor value of either 50kΩ or 100kΩ.  
The X and Y touch-screen plates create an open circuit  
with no current flow in the panel when the panel is not  
being touched. In this case, TOUCH (see Figure 6) is  
low. When a touch causes contact between the panel X  
and Y plates, a current path is created and TOUCH is  
checked against R . The interaction between R and  
TD  
TD  
the panel (or external noise rejecting) capacitance  
determines how quickly the panel can be switched from  
measurement modes back to touch monitoring mode  
without reporting false touches or erroneous tags due  
to panel settling.  
–MAX1803  
Panel touch status is also required to tag data from a  
completed scan and measurement operation. Following  
each scan operation, the panel must be returned to  
TDM to determine if the panel is still being touched and  
if the data obtained during the scan operation should  
be considered valid. This operation is required since  
the panel cannot be monitored for the presence of a  
touch during the scan and measurement procedure.  
pulled high, as long as R + R  
(the sum of panel  
PY  
PX  
end-to-end resistance) is much lower than R . Typical  
TD  
open-circuit panel plate resistances range from 200Ω  
to 1000Ω.  
The MAX11800–MAX11803 enter high-impedance  
pullup mode (50kΩ or 100kΩ) when the panel is not  
being touched and the device is idle in this mode until  
The MAX11800–MAX11803 must return to TDM after  
completing a measurement and making a decision on  
the touch status of the panel. The measurement proce-  
dure is only completed upon resolution of the touch sta-  
tus and when data is tagged and available for  
Table 3. Summary of Physical Panel Settings for Supported Measurement Types  
MODE  
Xꢀ  
X-  
Yꢀ  
Y-  
REFꢀ  
REF-  
X
Y
Z1  
Z2  
PUR  
V
GND  
U
GND  
GND  
U
ADC_IN  
U
GND  
U
ADC_IN  
GND  
X+  
Y+  
Y+  
Y+  
U
X-  
Y-  
X-  
X-  
DD  
ADC_IN  
ADC_IN  
U
V
DD  
V
DD  
V
DD  
U
V
(10Ω)  
DD  
V
through  
DD  
TDM or PUF  
LPM  
U
U
U
U
GND  
U
U
U
50kΩ or 100kΩ  
U
Note: The ADC input is fully differential with the negative input internally connected to GND. The MAX11800–MAX11803 control  
access to the PUR, PUF, TDM, and LPM, which do not require setup procedures.  
U indicates unconnected node.  
20 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
readback. The characteristics of the return to TDM and  
the timing of the decision are configurable through the  
touch-detect pullup timing configuration register (0x07).  
Program the MAX11800–MAX11803 in the context of  
the application to maximize power efficiency and  
achieve the desired scan throughput.  
teristics and the desired scan throughput rates to mini-  
mize power dissipation.  
While use of the PUR mode is optional, the PUF period  
is required for all applications. The PUF interval allows  
the panel to resettle following scan or optional PUR  
intervals. When a touch is not present, the panel capac-  
itance settles toward V  
through the internal pullup  
DD  
PUR and PUF  
PUR is a fast pullup mode, which uses the main X+  
switch in parallel with the resistive pullup to quickly slew  
the panel capacitance. PUF uses only the touch-detect  
switch and a portion of the panel resistance (with the  
optional PUR mode disabled). When a touch is present,  
the panel capacitance settles toward ground through a  
portion of the panel resistance, ideally significantly  
pullup resistor, R . PUR and PUF serve the same func-  
TD  
lower than the selected pullup impedance, R . Allow  
TD  
tion as TDM, but are timed so that the panel can settle  
after completing measurements and before rendering  
any decisions on the touch status of the panel.  
enough recovery time for settling through the panel  
when using a PUR mode. Figure 7 illustrates the touch-  
detection operations.  
Use the optional PUR mode to reduce the time to tag  
data by momentarily placing the panel in a low-imped-  
ance (< 10Ω) pullup mode instead of using the avail-  
able 50kΩ/100kΩ touch-detection pullup resistors. This  
operation forces the monitored TSC input high during  
the PUR interval. Once the PUR interval expires, a PUF  
interval must be allowed so that the panel can recover  
and pull the TSC input low in case a touch is present.  
The purpose of the PUR mode is to reduce the time  
required to determine touch status by avoiding long  
pullup time constants caused by high-capacitance  
touch panels and the high-impedance on-chip pullup  
Idle Modes  
Once the PUF period expires, the preceding measure-  
ment data is tagged and made available for readback.  
The MAX11800–MAX11803 transition to an appropriate  
mode depending on the conversion and interrupt mode  
selected.  
Features Common to the  
MAX11800–MAX11803  
Averaging Modes and Options  
The MAX11800–MAX11803 contain a programmable  
averaging filter. When enabled, this feature allows col-  
lecting 4, 8, or 16 consecutive samples for each mea-  
surement type requested. The number of the samples  
for each measurement type is controlled by configura-  
tion register 0x03. The AUX depth input is selected in  
configuration register 0x0A. Averaging can be  
assigned to each measurement type. For example, X  
and Y measurements can use an average of 16 sam-  
ples, while Z measurements can use one or four sam-  
ples to save power.  
resistors (R ). When a touch is present during PUR  
TD  
intervals, the current through the low-impedance pullup  
(XPSW) and panel combination is significantly higher  
than that observed in the PUF mode. The durations in  
the PUR mode must be matched to the panel charac-  
V
DD  
PSW  
TDRSEL  
The MAX11800–MAX11803 can be configured to per-  
form one of two statistical operations. One option is a  
median averaging filter (MAF). The MAF first removes  
outliers before taking the average of the remaining  
sample set. The second is a straight averaging filter  
(SAF), which takes the average of the entire sample set.  
RTD  
RTD  
TOUCH  
Y+  
(TO MAX11800/  
MAX11801 LOGIC)  
XPSW  
PUR TSW  
PUR, PUF, TDM  
X+  
X-  
Averaging modes are supported in both direct and  
autonomous conversion modes. Both filter types and  
position/pressure averaging are controlled by configu-  
ration register 0x0B. This allows switching between  
direct and autonomous modes using a single configu-  
ration write through the serial interface (SIF). Table 4  
presents the details of the median averaging operations  
of the MAX11800–MAX11803.  
Y-  
PANEL  
YMSW  
PUR, PUF, TDM  
MAX11800–  
MAX11803  
Figure 6. Touch-Detection Circuitry  
______________________________________________________________________________________ 21  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
FAST PULLUP TOUCH DETECTION  
DIGITAL WAVEFORM  
(NOTE: INCREASED CURRENT IN PUR MODE DURING TOUCH)  
DATA VALIDITY IS DETERMINED  
(DATA IS TAGGED)  
SCAN MODE  
PUR MODE  
(OPTIONAL)  
PUF MODE  
TOUCH DETECT  
MEASUREMENT COMPLETE—  
DATA IS KNOWN  
POWER ASSISTED PULLUP PERIOD (10Ω) PANEL IS ALLOWED TO RESETTLE BEFORE  
IS THERE A TOUCH?  
YES = LPM.  
DETERMINING DATA VALIDITY  
NO = TDM.  
ANALOG WAVEFORM  
V
DD  
TOUCH NOT PRESENT: TSC INPUT  
REMAINS HIGH  
TOUCH PRESENT:  
TSC INPUT PULLED LOW  
INITIAL INPUT VOLTAGE  
DETERMINED BY LAST SCAN  
ACTIVITY  
FORCED FAST PULLUP USING  
10Ω SWITCH  
–MAX1803  
TIME  
NORMAL TOUCH DETECTION  
DIGITAL WAVEFORM  
(NOTE: NO PUR PERIOD; ALLOW LONG PULLUP TIMES)  
DATA VALIDITY IS DETERMINED  
(DATA IS TAGGED)  
SCAN MODE  
PUF MODE  
TOUCH DETECT  
MEASUREMENT COMPLETE—  
DATA IS KNOWN  
PANEL IS ALLOWED TO RESETTLE BEFORE DETERMINING DATA VALIDITY  
IS THERE A TOUCH?  
YES = LPM.  
(THROUGH 50kΩ/100kΩ PULLUP)  
NO = TDM.  
ANALOG WAVEFORM  
V
DD  
TOUCH NOT PRESENT:  
TSC INPUT PULLED HIGH THROUGH 50kΩ/100kΩ PULLUP  
INITIAL INPUT VOLTAGE  
DETERMINED BY LAST SCAN  
ACTIVITY  
TOUCH PRESENT:  
TSC INPUT PULLED LOW BY PANEL  
TIME  
Figure 7. Touch-Detection Operations  
22 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Combined Commands  
Combined commands reduce AP interaction with the  
MAX11800–MAX11803 by allowing multiple measure-  
ments. For example, the MAX11800–MAX11803 can be  
instructed to provide X and Y data, or X and Y and Z1  
data, or X and Y and Z1 and Z2 data using a single  
command.  
retrieve the data from the last requested measurement  
before moving on to the next measurement of the type.  
Auxiliary measurement data is not tagged because it is  
not related to panel operation. Auxiliary measurement  
data is stored and read back identically to the other  
direct conversion data. The tag locations for auxiliary  
measurement data are always set to 0000b, unless the  
read occurs when an auxiliary measurement is in  
progress. In this situation, the tag locations read 1111b  
and the data stream reads back FFFFh.  
Data Tagging  
In direct conversion modes, all measurement data is  
contained in a 16-bit word. X, Y, Z1, and Z2 information  
is logged independently. Each word consists of 12 bits  
of measurement data plus a 2-bit measurement type  
(MTAG) and a 2-bit event tag (ETAG). The measure-  
ment tag identifies whether the data represents an X, Y,  
Z1, or Z2 result. The event tag indicates the point at  
which the data is sampled (initial, midpress, or release)  
during the touch event. When trying to read a result  
which is pending an update, the entire data stream is  
read back as FFFFh and the event tag as 11b, indicat-  
ing that the corresponding measurement is in progress  
and that the data stream is to be ignored. For com-  
bined commands, all data locations requested by the  
command are marked FFFFh, pending the completion  
of the entire command and the proper tagging of the  
data. See Table 5.  
Low-Power Modes  
There are also two low-power modes, LPM and TDM.  
During LPM, all circuitry is off, including the on-chip  
touch-detect pullup resistors used in the touch-detect  
circuitry. In direct conversion modes, a user-request ini-  
tiates the next operation and all circuitry is off until a  
user-command is received. Therefore, the current con-  
sumption is primarily due to junction leakage. In  
autonomous conversion mode, an on-chip oscillator  
and timer are constantly running. Therefore, the device  
current consumption is primarily determined by the  
oscillator and timer. During TDM, all circuitry is off  
except the on-chip pullup resistor. This is an untimed  
mode (oscillator and timer are off) for both ACM and  
DCM (no digital current). This mode only consumes  
current through the on-chip pullup resistor when a  
touch is present.  
Direct conversion modes do not use the internal FIFO  
or support the aperture (see the Aperture Modes and  
Options section) function. Each measurement type is  
afforded a single location in the memory. The AP must  
Table 4. Median Averaging Operations  
NUMBER OF  
NUMBER OF LOW  
NUMBER OF  
SAMPLES TAKEN  
NUMBER OF HIGH  
SAMPLES REMOVED  
REMAINING SAMPLES  
AVERAGING MODE  
SAMPLES REMOVED  
AVERAGED  
1
2
3
4
8
1
2
4
1
2
4
2
4
8
16  
Table 5. Data Word Structure (All Direct Conversion Modes)  
INDEX  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Byte  
MSB Byte  
Position MSBs  
Position Data  
LSB Byte  
12-Bit Content  
8-Bit Content  
Position LSBs  
Trailing Zeros  
Measure  
Measure  
Event  
Event  
______________________________________________________________________________________ 23  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Panel Setup, Measurement, and Scan Commands  
To simplify measurement procedures, the MAX11800–  
MAX11803 support three types of commands: panel  
setup commands (PSU), panel measurement commands  
(PMC), and combined measurement commands (CMC).  
combinations of measurements (X and Y, X and Y and  
Z1, or X and Y and Z1 and Z2 combined). Unlike  
autonomous conversion modes, the AP maintains control  
over the initiation of panel setup, measurements events,  
and the sampling frequency. Figure 8 shows the state  
machine transitions for direct conversion mode.  
In direct conversion mode, the MAX11800–MAX11803  
can use all three types of commands. Using individual  
panel setup and measurement commands allow for a  
high degree of customization based on decisions made  
by the AP, while using combined commands signifi-  
cantly simplifies the complete measurement process  
and reduces communications between the AP and the  
MAX11800–MAX11803.  
Interrupt Modes  
The MAX11800–MAX11803 support two direct conver-  
sion interrupt modes. The two direct conversion modes  
are the continuous interrupt mode (CINT) and the edge  
interrupt mode (EINT).  
Continuous Interrupt Mode  
In continuous interrupt mode, the panel returns to TDM  
and idle. The current status of the panel is then sent  
through TIRQ. The continuous interrupt mode is the  
least efficient mode in current consumption for long  
duration of touches. The power consumption is approxi-  
In autonomous mode, the MAX11800–MAX11803 use  
combined commands to control and automate all  
aspects of panel setup, measurements, and timing. See  
the Operating Mode Configuration Register (0x0B) sec-  
tion for more details.  
mated by P  
= V 2/R . The power consump-  
TOUCH  
DD PU  
Direct Conversion Mode Operations  
In direct conversion mode, the AP requests individual  
panel setup and conversion operations or automated  
tion levels observed when the panel is not touched is  
limited by the junction leakage currents of the  
MAX11800–MAX11803.  
–MAX1803  
SETUP  
X
PANEL  
NO  
COMMAND  
TOUCH  
DETECT  
TIME IS UP  
SETUP  
Y
PANEL  
NO  
COMMAND  
SETUP  
Z
PANEL  
NO  
COMMAND  
DONE AND  
CONTINUOUS  
DONE AND  
CONTINUOUS  
X
AUX  
ACQUIRE  
DETECT  
Y
Z1  
Z2  
ACQUIRE  
ACQUIRE  
ACQUIRE  
AVERAGE  
LAST  
AVERAGE  
CONVERSION  
LAST  
CONVERSION  
CONVERSION  
CONVERSION  
USER COMMAND  
INTERNAL TRANSITION  
TOUCH-  
DETECT  
FINE  
TOUCH-  
DETECT  
FINE  
TIME IS UP  
PULLUP  
PULLUP  
Figure 8. State Machine Transitions (Direct Conversion Mode)  
24 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
release is observed. In this state, there is no need to con-  
tinue monitoring the touch status prior to the next request-  
ed measurement. If a panel touch is not present, data is  
tagged as release (10) and the MAX11800–MAX11803  
idle in TDM continuously, issuing an interrupt only when  
the next panel touch is initiated.  
The MAX11800–MAX11803 idle in TDM. The TIRQ output  
goes low when a touch is detected on the panel indicat-  
ing to the AP that a touch is present and a measurement  
operation starts.  
The AP requests specific panel measurements through  
the serial interface. TIRQ stays low during panel setup  
and measurement operations. Once a measurement is  
complete (with CONT = 0), the MAX11800–MAX11803  
check for the continued presence of a touch on the  
panel and tag the data accordingly (see Table 6). The  
duration of this operation is programmable, specified in  
the touch-detect pullup timing configuration register  
(0x07). After the data is tagged, the data is available for  
readback through the serial interface. The  
MAX11800–MAX11803 return to TDM and return control  
of TIRQ to the TDM circuitry. TIRQ stays low while a  
touch remains present, indicating further measurements  
are required, otherwise TIRQ goes high until a new touch  
is observed.  
The operation described in the preceding paragraph  
makes the edge interrupt mode more efficient than the  
continuous interrupt mode. However, the edge interrupt  
mode requires continuous scanning of the panel until a  
release (10) event is observed. Otherwise, the  
MAX11800–MAX11803 do not idle in TDM and are not  
able to recognize a change in touch status. New touches  
are not recognized and new interrupts are not issued if a  
release event is not detected before stopping the conver-  
sion sequence.  
Table 6. Measurement and Event Tags  
(Continuous Interrupt Mode)  
Continuous interrupt mode (CINT) allows the complete  
control over the measurement operations and direct obser-  
vation of the touch status of the panel. Figure 9 shows the  
polling of TIRQ when other functions share the TIRQ bus. In  
the illustration of Figure 9, no ‘10’ event tag is observed  
because the release occurs during a TDM period.  
MEASUREMENT  
MTAG[3:2]  
X
Y
00  
01  
10  
11  
Z1  
Z2  
Edge Interrupt Mode  
When a touch is present on the panel in edge interrupt  
mode, the MAX11800–MAX11803 return to an untimed  
high-impedance mode once data tagging operations are  
complete. In edge interrupt mode, the duration of a touch  
is determined by the tags applied to the measurement  
data. Data tagged as initial (00) or midpress (01) indicates  
the user needs to continue to scan the panel until a  
EVENT  
ETAG[1:0]  
Touch (data valid)  
00  
01  
N/A (not used)  
No touch present (data  
invalid)  
Measurement in progress  
(data invalid)  
10  
11  
END OF TOUCH EVENT  
BEGINNING OF TOUCH EVENT  
PANEL  
TIRQ  
TDM  
TDM  
TDM  
DCM SCAN  
ETAG = 00  
TDM  
DCM SCAN  
ETAG = 00  
DCM SCAN  
ETAG = 00  
t
AP  
t
SD  
READBACK OPERATIONS ARE NOT SHOWN, BUT ARE EXECUTED DURING TDM PERIODS.  
SCAN INTERVAL (t ) IS CONTROLLED BY THE AP AND THE INITIATION OF DM SCAN EVENTS.  
AP  
SCAN DURATION (t ) IS A FUNCTION OF THE SCAN TYPE AND CONFIGURATION SETTINGS.  
SD  
Figure 9. Continuous Interrupt Mode (Direct Conversion Mode)  
______________________________________________________________________________________ 25  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
The EINT mode reduces TIRQ activity. During EINT, the  
Table 7. Measurement and Event Tags  
(Edge Interrupt Mode)  
MAX11800–MAX11803 idle in a TDM. TIRQ goes low  
when a new touch is detected on the panel. TIRQ stays  
low for a fixed duration as specified in the configuration  
register 0x01, indicating to the AP that a touch is pre-  
sent and measurements are required.  
MEASUREMENT  
MTAG[3:2]  
X
Y
00  
01  
10  
11  
The AP requests specific panel setups and measure-  
ments through the serial interface using panel setup  
and conversion commands after TIRQ goes low. Once  
a measurement is complete (with CONT = 0), the  
MAX11800–MAX11803 check for the continued pres-  
ence of a touch and tag the data accordingly. See  
Table 7. The duration of this operation is programma-  
ble, specified in the Touch-Detect Pullup Timing  
Configuration Register (0x07) section. After the data is  
tagged, it is available for readback through the serial  
interface. The MAX11800–MAX11803 do not return to  
TDM when the panel touch is still present (ETAG = 00,  
01), but remain in an LPM awaiting further measure-  
ment commands. The devices return to TDM when the  
panel touch is no longer present (ETAG = 10) and  
return control of the TIRQ interrupt to the TDM circuitry  
to await the next touch event.  
Z1  
Z2  
EVENT  
ETAG[1:0]  
Initial touch (data valid)  
Midpress (data valid)  
00  
01  
Release/no touch present  
(data invalid)  
10  
11  
Measurement in progress  
(data invalid)  
issued with CONT = 1 are not capable of fulfilling this  
requirement.  
–MAX1803  
The EINT mode provides the least interrupt activity and  
the lowest power consumption. Use EINT mode for  
general touch-screen applications and applications  
requiring high resolution in space and time. When the  
TIRQ bus is shared with other functions, poll the gener-  
al status register (0x00) to detect the presence of an  
interrupt. See Figure 10.  
After a touch is indicated, the AP must continue to issue  
conversion commands until the touch is removed alert-  
ing the AP when the panel is released (by ETAG = 10).  
The MAX11800–MAX11803 return to TDM and observe  
the start of the next touch event. Panel commands  
END OF TOUCH EVENT  
BEGINNING OF TOUCH EVENT  
PANEL  
t
TIRQ  
IRQ  
TDM  
LPM  
LPM  
TDM  
DCM SCAN  
ETAG = 00  
DCM SCAN  
ETAG = 01  
DCM SCAN  
ETAG = 10  
t
t
SD  
AP  
READBACK OPERATIONS ARE NOT SHOWN, BUT ARE EXECUTED DURING TDM PERIODS.  
TIRQ DURATION (t ) IS SPECIFIED BY THE GENERAL CONFIGURATION REGISTER (0x01).  
IRQ  
SCAN INTERVAL (t ) IS CONTROLLED BY THE AP AND THE INITIATION OF DM SCAN EVENTS.  
AP  
SCAN DURATION (t ) IS A FUNCTION OF THE SCAN TYPE AND CONFIGURATION SETTINGS.  
SD  
Figure 10. Edge Interrupt Mode (Direct Conversion Mode)  
26 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Table 8. Panel Setup Command Summary  
COMMAND  
LENGTH  
HEX  
R6  
R5  
R4  
R3  
R2  
R1  
R0  
ACCESS  
PAIRABLE  
OPERATION  
X = panel setup  
6xh  
6xh  
6xh  
6xh  
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
1
0
1
(1)  
(1)  
(1)  
(1)  
Write  
Write  
Write  
Write  
No  
No  
No  
No  
8
8
8
8
Y = panel setup  
Z1 = panel setup  
Z2 = panel setup  
Panel Setup Commands  
Panel setup commands configure the touch panel prior to  
a measurement. Panel setup commands allow the panel  
to fully settle before performing a measurement. The  
panel setup command summary is shown in Table 8. See  
the register map in the Status and Configuration Registers  
section for details on the panel setup timing options for X,  
Y, Z1, and Z2 measurements.  
LPM  
N
N
N
N
X PSU CMD  
Y
The continuation bit (CONT) of the panel setup com-  
mand programs the MAX11800–MAX11803 to maintain  
the present panel setting at the end of the command  
(CONT = 1). Panel setup commands assume a logical  
progression to an appropriate measurement. For exam-  
ple, when the MAX11800–MAX11803 are in the X panel  
setup mode, the devices can proceed to an X measure-  
ment mode only. The devices return to LPM when an  
incompatible command follows a panel setup com-  
mand. See Figure 11.  
N
N
N
N
X MEAS CMD  
Y
Y PSU CMD  
Y
Y MEAS CMD  
Y
Panel Measurement Commands  
A measurement command selects one of the four phys-  
ical setup options: X, Y, Z1, or Z2. The panel measure-  
ment command summary is shown in Table 8.  
Z1 PSU CMD  
Y
All panel measurement commands include timed inter-  
vals to power up both the internal ADC and the panel  
with programmable durations. The delayed conversion  
time (t  
, delayed conversion configuration register  
D_CV  
Z1 MEAS CMD  
Y
(0x06)) governs the time that the panel and the ADC  
need to settle prior to the initiations of conversions. The  
minimum delayed conversion time is 10μs, which is the  
time the internal ADC needs to power up. If more set-  
tling time is required, increase the panel settling time  
by delaying the conversion time or by adding an addi-  
Z2 PSU CMD  
Y
tional panel setup time (t ) using the panel setup tim-  
PSU  
ing configuration register (0x05). The advantage of  
using a dedicated panel setup time is that the ADC  
does not consume power during this interval. The  
required panel setup time is a function of the panel  
end-to-end resistance, the capacitance of the panel,  
and any board-level components.  
Z2 MEAS CMD  
Y
Figure 11. Command and Measurement Flow (DCM)  
______________________________________________________________________________________ 27  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Table 9. Panel Measurement Command Summary  
R0  
(CONT)  
COMMAND  
LENGTH  
HEX R7  
R6  
R5  
R4  
R3  
R2  
R1  
ACCESS PAIRABLE  
FUNCTION  
X, Y = combined command  
measurement  
7xh  
7xh  
7xh  
0
0
0
1
1
1
0
0
0
(0)  
(0)  
(0)  
Write  
Write  
Write  
No  
No  
No  
8
8
8
X, Y, Z1 = combined  
command measurement  
1
1
1
0
0
1
X, Y, Z1, Z2 = combined  
command measurement  
1
1
1
0
1
0
7xh  
7xh  
7xh  
7xh  
7xh  
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
0
0
1
1
1
0
1
0
1
(0)  
Write  
Write  
Write  
Write  
Write  
No  
No  
No  
No  
No  
8
8
8
8
8
AUX = conversion  
X = measurement  
Y = measurement  
Z1 = measurement  
Z2 = measurement  
CONT  
CONT  
CONT  
CONT  
–MAX1803  
When using a measurement command with CONT = 1 in  
a direct conversion mode, the MAX11800–MAX11803  
perform a data tagging operation at the conclusion of the  
command. The devices remain in the requested setup  
mode in preparation for the succeeding measurement.  
The panel does not return to TDM/LPM and the interrupt  
status is not modified as a result of a measurement com-  
mand with CONT = 1 issued. See Figure 12.  
ple and quantize the voltage at AUX using V  
as the  
DD  
ADC reference. The MAX11800–MAX11803 store the  
result in the same manner as X, Y, Z1, and Z2 measure-  
ments, but do not add data tagging. The devices also  
support averaging functions. Auxiliary measurements  
do not require any panel setup procedure. There is no  
combined command which includes an auxiliary mea-  
surement. Register 0x0A specifies the configuration for  
auxiliary measurements.  
Combined Commands  
In direct conversion modes, the panel returns to a TDM  
at the conclusion of a combined command and all data  
are tagged accordingly. The MAX11800–  
MAX11803 then idle in a low-power mode determined  
by the interrupt mode selected. See Figure 13.  
In CINT, the MAX11800–MAX11803 continue to monitor  
for the touch status of the panel. The devices report any  
change in touch status in real time during an auxiliary  
measurement procedure.  
When performing auxiliary measurements in edge  
interrupt mode, the MAX11800–MAX11803 temporarily  
suspend the panel touch monitoring. The devices noti-  
fy the AP after the completion of the auxiliary measure-  
ment when a new touch occurs during the auxiliary  
measurement.  
Auxiliary Measurement Command  
The MAX11800–MAX11803 support measurement of an  
auxiliary input using the internal ADC in direct conver-  
sion mode only. When programmed, the devices sam-  
28 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
PANEL SETUP COMMANDS (DIRECT CONVERSION ONLY)  
SETTING IS MAINTAINED UNTIL NEXT COMMAND (FORCE CONT = 1).  
PANEL SETUP (PSU) FOR X, Y, OR Z DRIVE  
MEASUREMENT COMMANDS (DIRECT CONVERSION ONLY)  
SINGLE CONVERSION WITH CONT = 1  
SETUP  
ADC  
CONVERSION  
DATA IS LOGGED.  
SETTING IS MAINTAINED UNTIL NEXT COMMAND (CONT = 1).  
ADC  
ACQUISITION  
PSU  
(t  
(t  
+ t  
)
PSU D_CV  
AVERAGED CONVERSION WITH CONT = 1  
AVERAGED DATA IS LOGGED.  
SETTING IS MAINTAINED UNTIL NEXT COMMAND (CONT = 1).  
SETUP  
ADC  
ADC  
PSU  
+ t  
)
CONVERSION  
ACQUISITION  
PSU D_CV  
i
i
N
AVG  
SINGLE CONVERSION WITH CONT = 0  
DATA IS TAGGED AND LOGGED.  
THE MAX11800–MAX11803 RETURN TO LPM OR TDM, ACCORDING TO IRQ MODE.  
ADC  
ACQ  
ADC  
CONV  
PUR  
(OPT)  
SETUP  
SETUP  
PUF  
AVERAGED CONVERSION WITH CONT = 0  
AVERAGED DATA IS TAGGED AND LOGGED.  
THE MAX11800–MAX11803 RETURN TO LPM OR TDM, ACCORDING TO IRQ MODE.  
ADC  
ACQ  
ADC  
CONV  
PUR  
(OPT)  
PUF  
i
i
N
AVG  
Figure 12. Panel Setup and Measurement Commands  
______________________________________________________________________________________ 29  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
X AND Y COMMANDS  
SINGLE CONVERSIONS  
DATA EVENT TAGGING  
PUR  
X
X
X
Y
PSU  
Y
ACQ  
Y
PUF  
PSU  
ACQ  
CONV  
CONV  
(OPT)  
AVERAGED CONVERSIONS  
X
PSU  
X
ACQ  
X
Y
PSU  
Y
ACQ  
Y
PUR  
(OPT)  
PUF  
CONV  
CONV  
N
AVGX  
N
AVGY  
X, Y, AND Z1 COMMANDS  
SINGLE CONVERSIONS  
X
PSU  
X
ACQ  
X
Y
PSU  
Y
ACQ  
Y
Z1  
PSU  
Z1  
ACQ  
Z1  
CONV  
PUR  
(OPT)  
PUF  
PUF  
CONV  
CONV  
AVERAGED CONVERSIONS  
X
PSU  
X
ACQ  
X
Y
PSU  
Y
ACQ  
Y
Z1  
PSU  
Z1  
ACQ  
Z1  
CONV  
PUR  
(OPT)  
–MAX1803  
CONV  
CONV  
N
N
AVGY  
N
AVGZ1  
AVGX  
X, Y, Z1, AND Z2 COMMANDS  
SINGLE CONVERSIONS  
X
PSU  
X
ACQ  
X
Y
PSU  
Y
ACQ  
Y
Z1  
PSU  
Z1  
ACQ  
Z1  
CONV  
Z2  
ACQ  
Z2  
CONV  
PUR  
(OPT)  
PUF  
PUF  
CONV  
CONV  
AVERAGED CONVERSIONS  
X
PSU  
X
ACQ  
X
Y
PSU  
Y
ACQ  
Y
Z1  
PSU  
Z1  
ACQ  
Z1  
CONV  
Z2  
ACQ  
Z2  
CONV  
PUR  
(OPT)  
CONV  
CONV  
N
N
AVGY  
N
N
AVGZ2  
AVGX  
AVGZ1  
Figure 13. Combined Commands  
30 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
transfers on the serial bus as well as generating fewer  
interrupt requests. Figure 14 shows the state machine  
transitions for autonomous conversion mode.  
Autonomous Conversion Mode  
The MAX11800/MAX11801 perform measurements  
automatically and inform the AP when they are com-  
plete in autonomous conversion mode, reducing data  
TOUCH-  
DETECT  
ROUGH  
PULLUP  
TOUCH-  
DETECT  
FINE  
XY MODE  
TIME IS UP  
TIME IS UP  
POWER  
DOWN  
AVERAGE  
CONVERSION  
LAST  
CONVERSION  
TOUCH  
DETECT  
PULLUP  
TOUCH-  
DETECT  
ROUGH  
PULLUP  
SETUP  
Z
PANEL  
Y
ACQUIRE  
NO  
TOUCH  
TOUCH-  
DETECT  
FINE  
SETUP  
Y
PANEL  
Z1  
ACQUIRE  
AVERAGE  
CONVERSION  
LAST  
CONVERSION  
PULLUP  
Z2  
ACQUIRE  
TOUCH  
DETECT  
AVERAGE  
CONVERSION  
LAST  
CONVERSION  
AVERAGE  
CONVERSION  
LAST  
CONVERSION  
SETUP  
X
PANEL  
TIME IS UP  
X
ACQUIRE  
Figure 14. State Machine Transitions––Autonomous Conversion Mode  
______________________________________________________________________________________ 31  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Measurement Operations  
In autonomous conversion, the MAX11800/MAX11801  
idle in TDM until a touch event occurs. The  
MAX11800/MAX11801 begin an automated sequence  
of measurements as defined by the configuration regis-  
ter 0x08h.  
timed high-impedance LPM to minimize current, after  
the data tagging operations are complete. The  
MAX11800/MAX11801 idle in LPM until it is time to per-  
form the next required scan, determined by the config-  
uration register settings. When a touch is not present at  
the end of a measurement, the device returns to idle in  
TDM. In TDM, the device waits until a touch is detected  
before initiating another set of autonomous measure-  
ments.  
The MAX11800/MAX11801 tag and log the data into the  
FIFO once a measurement is taken. If a touch is still pre-  
sent, the devices continue to idle in a LPM until the time,  
as set by the configuration settings, expires. If no touch is  
present at the expiration of the time set by the configura-  
tion settings, the MAX11800/MAX11801 return to TDM to  
await the next panel touch.  
The MAX11800/MAX11801 adopt a clear-on-interrupt  
protocol (CORINT) when in autonomous conversion  
mode. Between touch events, the devices idle in a low-  
power TDM state. Upon detection of a touch, the  
devices begin a sequence of automated measure-  
ments. Each time a qualifying measurement is complet-  
ed, the data for that measurement is written to the  
internal FIFO. Qualifying measurements are measure-  
ments that indicate the beginning and end of a touch  
event, which meet aperture requirements (see the  
Aperture Range Requirements section).  
All measurement operations occur without any interven-  
tion from the AP. The MAX11800/MAX11801 issue inter-  
rupts when new data is available in the internal FIFO. The  
device clears the interrupt when all data is read back.  
The AP controls the readback of measurement data as  
the data becomes available.  
Combined Commands  
In autonomous conversion mode, the MAX11800/  
MAX11801 automatically perform the combined com-  
mand defined in the configuration register. The devices  
continuously scan for panel touch events. Between  
scans, the devices idle in a low-power mode according  
to the present touch status.  
TIRQ issues an interrupt once a qualifying measure-  
ment is completed and logged into the FIFO indicating  
that new data is available for the AP to read back. The  
MAX11800/MAX11801 continue to perform measure-  
ments as required by the configuration settings.  
Program the AP to service the interrupt immediately to  
avoid a FIFO overflow and loss of data. TIRQ remains  
asserted until all unread FIFO data has been read back  
to the AP. The AP confirms that readback is complete  
either by monitoring TIRQ or by monitoring the data  
event tags embedded in the data for end-of-FIFO.  
(ETAG = 11b). See Figure 15.  
–MAX1803  
Clear-on-Read Interrupt Mode  
The MAX11800/MAX11801 control the progression  
through modes in clear-on-read mode. When the panel  
touch is present, the MAX11800/MAX11801 return to a  
BEGINNING OF TOUCH EVENT  
END OF TOUCH EVENT  
PANEL  
INTERRUPT IS HELD PENDING  
AP READBACK (FIFO STORES DATA)  
DATA WRITTEN TO FIFO,  
INTERRUPT ISSUED  
AP READBACK,  
INTERRUPT CLEARED  
TIRQ  
SCAN  
BLOCK  
LPM  
TDM  
t
LPM  
TDM  
ACM SCAN  
ETAG = 00  
ACM SCAN  
ETAG = 01  
ACM SCAN  
ETAG = 10  
t
SD  
t
SP  
INIT  
READBACK OPERATIONS ARE NOT SHOWN, INDICATED BY THE CLEARING OF THE AP-INITIATED INTERRUPT.  
WAIT TIME BETWEEN TOUCH DETECTION AND INITIAL SCAN (t ) IS SPECIFIED BY CONFIGURATION SETTINGS.  
INIT  
SCAN DURATION (t ) IS A FUNCTION OF THE SCAN TYPE AND CONFIGURATION SETTINGS.  
SD  
SCAN PERIOD (t ) IS CONTROLLED BY CONFIGURATION SETTINGS.  
SP  
Figure 15. Clear-on-Read Interrupt Operation  
32 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Delayed Touch Detection During Mode Transitions  
The MAX11800/MAX11801 support a low-power power-  
down mode suspending all touch-screen activity and  
the panel is not driven. In this mode, the  
MAX11800/MAX11801 is unable to detect a touch.  
When commanded to transition from PWRDN to any  
normal mode of operation, the MAX11800/MAX11801  
go through a PUR/PUF sequence prior to observing the  
panel touch status, minimizing the occurrence of inter-  
rupts issued by false touches caused by the initial state  
of panel capacitances.  
The FIFO completely clears when autonomous conver-  
sions halt and the MAX11800/MAX11801 transition to  
direct conversion mode. The FIFO also clears on transi-  
tions from direct conversion mode to autonomous mode.  
FIFO Data Block Readback Structure  
Table 10 illustrates the scan data block structure within  
the FIFO for each scan type. Block boundaries are indi-  
cated by bold lines. Numeric subscripts denote the sam-  
ple order when the data was taken. Readback proceeds  
from top to bottom. FIFO blocks are written as a com-  
plete unit with an interrupt issued only after all required  
block measurements are complete and data is tagged.  
A FIFO data block consists of 2 to 4 FIFO data words.  
In addition, when commanded to transition between  
normal operating modes, the MAX11800/MAX11801  
clear any existing interrupts and go through the  
PUR/PUF sequence prior to observing the current panel  
touch status.  
Table 10. FIFO Data Block Structure  
FIFO Memory  
The MAX11800/MAX11801 include an internal FIFO to  
store scan block results for readback through the AP.  
Each scan block result contains complete data for all  
measurements requested by the scan type (X, Y; or X,  
Y, Z1; or X, Y, Z1, Z2). The depth of each scan data  
block ranges from 32 bits (X, Y mode) to 48 bits (X, Y,  
Z1 mode) or 64 bits (X, Y, Z1, and Z2 mode).  
2-WORD BLOCK  
(X, Y)  
3-WORD BLOCK  
(X, Y, Z1)  
4-WORD BLOCK  
(X, Y, Z1, Z2)  
X MSB  
1
X MSB  
1
X MSB  
1
X LSB  
1
X LSB  
1
X LSB  
1
Y MSB  
1
Y MSB  
1
Y MSB  
1
Y LSB  
1
Y LSB  
1
Y LSB  
1
X MSB  
2
Z1 MSB  
1
Z1 MSB  
1
The internal FIFO stores up to 16 complete scan  
blocks, a total of 1024 bits. Regularly service the FIFO  
to prevent overflow conditions. In the event of an over-  
flow, the FIFO ceases to write new data until the old  
data is read or cleared. Avoid overflow to prevent data  
loss and unreliable behavior.  
X LSB  
2
Z1 LSB  
1
Z1 LSB  
1
Y MSB  
2
X MSB  
2
Z2 MSB  
1
Y LSB  
2
X LSB  
2
Z2 LSB  
1
X MSB  
3
Y MSB  
2
X MSB  
2
X LSB  
Y LSB  
X LSB  
2
3
2
Check the general status register (0x00) and the FIFO  
overflow bit to determine if the FIFO is in overflow. The  
FIFO overflow bit asserts when a data overflow occurs.  
See the Clearing FIFO section.  
Y MSB  
3
Z2 MSB  
2
Y MSB  
2
Y LSB  
3
Z2 LSB  
2
Y LSB  
2
X MSB  
4
.
.
.
.
Z1 MSB  
2
Clearing FIFO  
Write to the operating mode configuration register (0x0B)  
to clear the FIFO. Modifying the contents of the register is  
not necessary as any write operation to this register loca-  
tion clears the FIFO and the interrupt TIRQ (if present).  
X LSB  
4
Z1 LSB  
2
Y MSB  
4
Z2 MSB  
2
Y LSB  
4
Z2 LSB  
2
______________________________________________________________________________________ 33  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
FIFO Data Word Structure  
Table 11 shows a 16-bit data word (MSB byte + LSB  
byte). Each data word consists of 12 bits of position  
data, mapped to locations [15:4]. Eight-bit measure-  
ment data are left-adjusted and mapped to locations  
[15:8] and followed by four trailing zeros. Table 12  
shows a 2-bit measurement tag indicating the measure-  
ment type (X, Y, Z1, or Z2), appended in locations [3:2].  
Table 13 shows a 2-bit event tag indicating where the  
sample occurs within a touch event (initial, midpress, or  
release) in locations [1:0].  
Clearing Interrupt  
The FIFO is only used in the autonomous mode with the  
clear-on-read interrupt. The interrupt is cleared only  
when the newest data block currently available in the  
FIFO is loaded for readback. The interrupt does not  
clear if there is any unread data block remaining in the  
FIFO once a scan block result is loaded. The FIFO does  
not check for partial block readbacks. Once the last  
available FIFO data block is loaded for readback, the  
interrupt clears regardless of whether the readback  
operation for that block is complete.  
All data for a given scan operation is tagged according  
to the touch status observed at the end of the scan  
block measurement operations. For example, if a  
requested X, Y, Z1, Z2 scan block contains a release  
event, all the data words are tagged 10 before being  
written to the FIFO.  
Aperture Modes* and Options  
The aperture modes available with the MAX11800/  
MAX11801 implement spatial filtering. The MAX11800/  
MAX11801 contain the required logic to examine panel  
measurement data and determine if the data meets the  
aperture requirements to be written to the FIFO. Aperture  
testing decreases the number of entries in the FIFO to  
the minimum required to implement the intended appli-  
cation. The elimination of extraneous FIFO data events  
reduces activity on the TIRQ line, serial bus, and mini-  
mizes AP overhead. The contents in the FIFO are not  
necessarily linearly sampled in time when the device is in  
aperture mode.  
An event tag of 11 indicates that the data readback  
operation reaches the end of the current FIFO data log  
(end of file marker) and there is no unread data in the  
FIFO. Terminate the readback operation to await the  
next interrupt. Ignore all data with the 11 event tag.  
–MAX1803  
Block Readback Operations  
The MAX11800/MAX11801 do not support partial block  
readback operations. Each readback operation loads  
an entire scan block result (32, 48, or 64 bits) into a  
temporary location for serial readback. A scan block is  
marked as read in the FIFO once a scan block result is  
loaded, freeing the memory space for the subsequent  
measurements. Once initiated, the AP must complete  
the full readback cycle for the block requested or the  
unread portions of the block data is lost.  
Aperture Range Requirements  
Program the aperture range requirements for both X  
and Y through register 0x0B. Range requirements are  
expressed as distance, in position LSBs. The blanking  
aperture extends from the initial touch position, both  
ΔX and ΔY with 12-bit resolution (1 LSB = 1/4096 of  
the corresponding screen dimension). An aperture set-  
ting of 0x00 effectively disables aperture checking with  
all measurement data logged to the FIFO. Apertures  
are specified in a power-of-two format: ΔX = 2APRX[3:0]-1  
and ΔY = 2APRY[3:0]-1  
.
Table 11. FIFO Data Word Structure  
INDEX  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Byte  
MSB Byte  
Position MSBs  
Position Data  
LSB Byte  
12-Bit Content  
8-Bit Content  
Position LSBs  
Trailing Zeros  
Measure  
Measure  
Event  
Event  
Table 12. FIFO Data Measurement Tags  
Table 13. FIFO Event Tags  
EVENT  
TAG[1:0]  
MEASUREMENT  
TAG[3:2]  
Initial touch  
00  
01  
10  
X
Y
00  
01  
10  
11  
Midpress  
Release (data invalid)  
Z1  
Z2  
End of file indicator  
(FIFO data invalid)  
11  
*Patented feature.  
34 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
For example:  
0000 = 2-1 LSB = aperture checking disabled  
0001 = 2(1-1) LSB = 1 LSB  
Applications Information  
Using Aperture Mode  
The MAX11800/MAX11801 accommodate touch-panel  
0010 = 2(2-1) LSB = 2 LSB  
0011 = 2(3-1) LSB = 4 LSB  
1001 = 2(9-1) LSB = 256 LSB (1/16 of the screen in  
each direction)  
1010 = 2(10-1) LSB = 512 LSB (1/8 of the screen in  
each direction)  
1011 = 2(11-1) LSB = 1024 LSB (1/4 of the screen in  
each direction)  
applications where limited resolution in both time and  
space can be traded off for reduced microprocessor  
activity. A simulated keypad is an example of an appli-  
cation where autonomous conversions with aperture  
checking yield an efficient solution.  
The AP determines the durations of touch-screen  
presses. An issuance of TIRQ interrupts accompanies  
all FIFO events. The interrupts clear when all existing  
data is read back by the AP, allowing the AP to correct-  
ly interpret held panel data.  
The FIFO updates immediately when a new touch event  
is detected. The system assumes that the panel touch is  
continuous after the AP receives the interrupt. The  
MAX11800/MAX11801 continue to scan the panel at the  
user-programmed sample rate. The FIFO updates when  
the measurement data shows that the panel touch loca-  
tion moves (i.e., a measurement exceeds either of the  
selected aperture ranges). The FIFO also updates upon  
detection of a panel release. The AP determines the  
duration of the press by observing the time between the  
leading edge of the touch (tag 00) and the release edge  
of the touch (tag 10). All midpress data (tag 01) are inter-  
preted as part of a dragged touch event.  
1100 = 2(12-1) LSB = 2048 LSB (1/2 of the screen in  
each direction)  
1101 to 1111 = aperture checking disabled  
FIFO Aperture Criteria  
In autonomous mode with aperture engaged, new data  
is written to the FIFO, and an interrupt is issued when  
the following conditions occur (aperture mode is not  
available in direct conversion mode).  
New Panel Touch Initiated  
The FIFO updates and issues an interrupt when a new  
touch is observed on the panel (data tag = 00). This  
event occurs regardless of the current aperture setting  
and the previous touch location so that multiple presses  
in the same location can be observed and registered.  
All valid touch events log two data points into the FIFO:  
an initial data point at the beginning of the touch (tag  
00) and a release data point at the termination of the  
touch (tag 10). Discard release edge position data as  
invalid as the MAX11800/MAX11801 cannot determine  
at which point in the ADC conversion cycle the panel is  
released during the measurement operation. If the  
release occurs while the ADC is actively sampling the  
panel, the results are invalid. Only initial and midpress  
position data are reliable.  
Continuous Panel Touch Terminated  
The FIFO updates and issues an interrupt when a con-  
tinuous panel touch is terminated (data tag = 10). This  
event occurs regardless of the current aperture setting  
and the previous continuous touch location(s) so that  
multiple presses in the same location can be observed  
and registered.  
Any touch event too short in duration to log both initial  
and release data points is recorded in the FIFO as a  
release (tag 10) and discarded as a glitch event.  
Continuous Panel Touch  
Measurement Meets Aperture Criteria  
The MAX11800/MAX11801 log the measurement data  
to the FIFO and issue an interrupt when a measurement  
during a continuous panel touch (event tag = 01) meets  
the aperture criteria (i.e., lies on or outside the aperture  
boundary). This event occurs when the point of contact  
is dragged across the touch screen. Only the ΔX or ΔY  
aperture criteria need to be met and a greater than or  
equal to qualification criterion is applied. If the change  
in X position or change in Y position exceeds the aper-  
ture criteria, then an interrupt is generated.  
Measuring durations of panel touches becomes  
impractical when the AP services the MAX11800/  
MAX11801 at lower than the operating speed of the  
devices and the panel combined. The AP cannot time  
the duration between panel touches when both the ini-  
tial and release data points can be logged before the  
initial interrupt is serviced. Do not allow the FIFO to  
overflow as touch information can be lost and the FIFO  
content becomes invalid.  
______________________________________________________________________________________ 35  
 
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
When the MAX11800/MAX11801 operate in autonomous  
conversion mode with low or no aperture ranges, the  
FIFO and interrupt activity occur frequently with the AP  
servicing the devices frequently to avoid loss of data  
due to limited FIFO depth. For this reason, do not per-  
form autonomous conversion for applications where a  
high resolution in either space or time is required. Use  
direct conversion mode when requiring a high resolu-  
tion in either space or time.  
that meet aperture requirements are enumerated and  
are shown with the corresponding aperture ranges.  
Positions 6 and 7 show a subsequent momentary press  
event.  
Figure 16 shows the anticipated interrupt waveforms in  
several operating modes. The first waveform shows  
interrupt operation assuming that aperture mode is  
enabled (with ΔX = ΔY = 4 LSBs), assuming that the AP  
service interrupts at a frequency faster than the select-  
ed TSC sample rate. Each qualifying sample induces a  
FIFO event and an interrupt pulse as shown. Timing  
between FIFO events can be timed by the AP to deter-  
mine duration information. Table 14 shows the read-  
back data assuming that the FIFO does not fill up.  
Examples of Using Aperture Mode  
Figure 16 shows an example of a touch sequence. A  
dragged touch sequence is initiated at position 1 and  
continues through to position 5. While multiple samples  
are taken during this sequence, only those samples  
ONE DRAG EVENT (1:5)  
AND ONE PRESS EVENT (6:7)  
PANEL TOUCH SPATIAL WAVEFORM  
16  
SECOND  
RELEASE  
DRAG  
7
APER1  
6
–MAX1803  
SECOND  
TOUCH  
APER2  
12  
DRAG  
INITIAL  
TOUCH  
1
APER6  
2
8
5
4
INITIAL  
DRAG  
RELEASE  
3
DRAG  
4
APER4  
APER3  
12  
INTERRUPT TIMING WAVEFORM 1 (ASSUMING FREQUENT SERVICING EVENTS WITH APERTURE MODE ENABLED)  
0
4
8
16  
20  
24  
2
1
3
4
5
6
7
INTERRUPT TIMING WAVEFORM 2 (ASSUMING FREQUENT SERVICING EVENTS WITH APERTURE MODE DISABLED)  
2
1
3
4
5
6
7
INTERRUPT TIMING WAVEFORM 3 (ASSUMING INFREQUENT SERVICING EVENTS)  
(1) IRQ ISSUED  
(SERVICED) IRQ RELEASED  
NOTE: POSITION 5 IS LOGGED EVEN THOUGH POSITION 5 APPEARS IN APER4 BECAUSE POSITION 5 IS A RELEASE DATA POINT.  
IT IS THE SAME FOR POSITION 7. IF THE POSITION 6 TOUCH EVENT INITIATES WITHIN THE FINAL APERTURE FROM THE  
PREVIOUS EVENT (APER4), POSITION 6 IS LOGGED AS AN INITIAL TOUCH EVENT.  
Figure 16. Aperture Usage Example Waveforms  
36 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
The second waveform shows an interrupt operation  
assuming that aperture mode is disabled (or that ΔX =  
ΔY = 0 LSB), assuming that the AP service interrupts at  
a frequency faster than the selected TSC sample rate.  
Every sample induces a FIFO event and an interrupt  
pulse as shown. The interrupt waveform is significantly  
busier than that shown in the first waveform. Duration  
information can now be directly determined from the  
FIFO samples since each sample is logged and occurs  
at the programmed sample rate. Table 15 lists the read-  
back data assuming the FIFO does not fill up.  
The third waveform in Figure 16 shows an interrupt oper-  
ation assuming that the MAX11800/MAX11801 are infre-  
quently serviced. Ensure that the FIFO does not overflow.  
No duration information is available at resolutions below  
the servicing rate. Either the set of data shown in Table  
14 or the set shown in Table 15 appears in the FIFO  
when read, depending on the aperture setting.  
Table 14. Readback and FIFO Contents with Aperture Mode Enabled  
SAMPLE  
X
Y
11  
9
TAG  
COMMENT  
1
2
3
4
5
6
7
7
00  
Initial event (beginning of first touch)  
11  
13  
17  
19  
22  
23  
01  
Midpress event  
5
01  
Midpress event  
7
01  
Midpress event (last valid position data)  
Release event (end of first touch, ignore position data)  
Initial event (beginning of second touch)  
Release event (end of second touch, ignore position data)  
6
10  
14  
15  
00  
10  
Table 15. Readback and FIFO Contents with Aperture Mode Disabled  
SAMPLE  
X
Y
11  
10  
9
TAG  
00  
01  
01  
01  
01  
01  
01  
01  
01  
10  
00  
10  
COMMENT  
Initial event (beginning of first touch)  
1
1a  
2
7
9
Midpress event  
11  
12  
13  
13  
13  
15  
17  
19  
22  
23  
Midpress event  
2a  
2b  
2c  
3
8
Midpress event  
7
Midpress event  
6
Midpress event  
5
Midpress event  
3a  
4
6
Midpress event  
7
Midpress event (last valid position data)  
Release event (end of first touch, ignore position data)  
Initial event (beginning of second touch)  
Release event (end of second touch, ignore position data)  
5
6
6
14  
15  
7
______________________________________________________________________________________ 37  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
SPI Configuration Register Write  
(MAX11800/MAX11802)  
SPI Communication Sequence  
(MAX11800/MAX11802)  
Figure 17 shows the supported write operation  
sequence for the MAX11800/MAX11802. A single con-  
figuration register can be written in a 2-byte operation,  
composed of a target register address (A[6:0], plus a  
write mode indicator bit) followed by data to be written  
to the target register (D[7:0]).  
The SPI interface consists of three inputs, DIN, DCLK,  
CS, and one output, DOUT. A logic-high on CS dis-  
ables the MAX11800/MAX11802 digital interface and  
places DOUT in a high-impedance state. Pulling CS low  
enables the MAX11800/MAX11802 digital interface. The  
MAX11800/MAX11802 provide two possible implemen-  
tations of SPI instructions. In rising-edge-driven opera-  
tions, the devices are able to run at maximum clock  
speeds. Carefully consider the hold time requirements  
of the MAX11800/MAX11802 and minimize board skew  
contributions when running the MAX11800/MAX11802  
at maximum clock speed. In falling-edge-driven opera-  
tions, the device is less sensitive to board skew contri-  
butions, but slower clock speeds are required to meet  
the MAX11800/MAX11802 setup time requirements. For  
the MAX11800/MAX11802, read patterns output data is  
either latched on the rising edge running at maximum  
clock rates or on the falling edges running at reduced  
clock rates.  
During write sequences, the DOUT line is not accessed  
by the SPI. DOUT remains high impedance throughout  
the command. Using the optional bus holder, the DOUT  
line retains the previous value unless altered by a  
device sharing the bus.  
The MAX11800/MAX11802 SPI interface supports multi-  
ple register write operations within a single sequence  
as shown in Figure 18. By repeating the address plus  
data byte pairs (in write mode), an unlimited number of  
registers can be written in a single transfer. Do not per-  
mit to combine write and read operations within the  
same SPI sequence.  
–MAX1803  
CS  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
SCLK  
DIN  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
Wb  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Figure 17. SPI Single Configuration Register Write Sequence  
CS  
1
7
9
17  
23  
25  
32  
SCLK  
DIN  
A [6:0]  
n
D [7:0]  
n
A
m
[6:0]  
D [7:0]  
m
Figure 18. SPI Multiple Configuration Register Write Sequence  
38 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
SPI Configuration or  
Result Register Read (MAX11800/MAX11802)  
Figure 19 shows the read operation sequence for the  
MAX11800/MAX11802. A single configuration register  
can be read back in a 2-byte operation, composed of a  
requested register address (A[6:0], plus a read mode  
indicator bit) followed by the data contents from that reg-  
ister (D[7:0]).  
crement is supported, the next register location is read  
back. If not, the last valid register location is read back  
(see the Command and Register Map section for the  
autoincrement attributes of each register). The following  
example shows a valid sequence for the readback of  
three register locations (D through D ).  
i
i+2  
The autoincrement reads only the X, Y, Z1, Z2, and AUX  
result registers preventing inadvertent readback of unre-  
lated or reserved data locations. For example, if begin-  
ning at the XMSB register, a user can cycle through the  
XLSB register to the YMSB register and so forth up to the  
AUXLSB register. The MAX11800/MAX11802 do not  
autoincrement beyond the AUXLSB register. If clock  
cycles continue to be given, the AUXLSB register read-  
back is repeated.  
During read operations, the SPI takes control of the DOUT  
line following the eight SCLK rising edge. The SPI retains  
control of the DOUT line until CS rises, terminating the  
operation. To support multiple register readback opera-  
tions, data continues to be ported following the 16th rising  
clock edge. For single-byte transfers, this sub-bit informa-  
tion can be ignored, shown as S, in Figure 19.  
The FIFO register does not autoincrement, which allows  
multiple readbacks of the same location. This allows the  
access of multiple FIFO memory blocks with a single read  
operation. When reading back FIFO registers, data man-  
agement is handled in blocks not bytes. As a result, when  
an SPI read operation supplies at least one cycle of read-  
back of the first byte of a FIFO block, the entire block is  
marked as read, regardless of whether the block or even  
byte readback is run to completion.  
The DOUT output on the MAX11800/MAX11802 includes  
an optional bus holder to prevent the DOUT line from  
maintaining an indeterminate state when vacated by the  
device in the absence of an external bus pullup or bus  
sharing devices. The bus holder is designed not to inter-  
fere with other drivers sharing the DOUT line and holds  
the last valid state of the line, regardless of source.  
Disable the bus holder when not needed.  
The MAX11800/MAX11802 support the combination of  
the DIN and DOUT lines. To avoid data contention and  
possible high current states, the master device must relin-  
quish control of the combined line at the 8th clock rising  
edge, allowing the MAX11800/MAX11802 to access the  
line through the end of the sequence. This is terminated  
on the rising edge of CS. See the SPI Timing  
Characteristics for relevant details.  
To illustrate, assume the MAX11800 is in autonomous  
mode performing XY conversions and a FIFO readback  
is requested starting at register 0x50. Clock cycles 9 to  
40 are required to complete the readback of the first  
available FIFO block = {XMSB , XLSB , YMSB , YLSB }  
i
i
i
i
i
with the device updating in response to the 8th to 39th  
clock rising edges. The host processor can complete  
the readback data latching of YLSB [0] either on the  
i
The MAX11800/MAX11802 also support multiple register  
readback operations using a single command. The proto-  
col requires the user to supply an initial starting register  
location, followed by an unlimited number of clock pulses  
for data readback.  
39th falling edge or the 40th rising edge. To support a  
continued readback of further FIFO blocks, the device  
updates the DOUT line to XMSB [7] in response to the  
i+1  
40th clock rising edge (though block  
is not marked  
i+1  
as read). If the AP supplies a 42nd clock rising edge,  
The first data read back is from the start register. The  
MAX11800/MAX11802 internal autoincrement counter  
manages the data readback in later cycles. If autoin-  
the FIFO block , if present, is marked as read, regard-  
i+1  
less of whether any further clock cycles are provided.  
CS  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
SCLK  
DIN  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
R
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
S
DOUT  
Figure 19. SPI Single-Byte Register Read Sequence  
______________________________________________________________________________________ 39  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
SPI Conversion Command (MAX11800/MAX11802)  
The sequence below shows the required command for-  
mat for issuing conversion requests. A conversion  
request cannot be paired with multiple commands or  
instructions. Any conversion command issued while  
previous commands are being executed is ignored.  
ically a microcontroller) initiates data transfer on the  
bus and generates SCL. The I2C device address is  
10010xx; the last 2 bits of the I2C address are user-  
configurable through the address inputs A[1:0].  
I2C Configuration Register Write  
(MAX11801/MAX11803)  
I2C-Supported Sequence  
(MAX11801/MAX11803)  
Repeat the register address plus data pairs (byte 2 and  
byte 3 in Figures 21, 22, and 23) to perform multiple  
register writes. There is no limit to the number of regis-  
ters written with a single command. For example, the  
I2C master can perform multiple register writes to set up  
all required conversion options, and then issue a sepa-  
rate I2C command to start a conversion process.  
The MAX11801/MAX11803 feature an I2C-compatible,  
2-wire serial interface consisting of a bidirectional serial  
data line (SDA) and a serial clock line (SCL). SDA and  
SCL facilitate bidirectional communication between the  
MAX11801/MAX11803 and the master. The master (typ-  
CS  
1
7
8
9
16 17  
24 25  
32  
SCLK  
A [6:0]  
i
DIN  
–MAX1803  
S
D [7:0]  
i
D
i+1  
[7:0]  
D [7:0]  
i+2  
DOUT  
Figure 20. SPI Multiple-Byte Register Read Sequence  
CS  
1
2
3
4
5
6
7
8
SCLK  
DIN  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
Wb  
Figure 21. SPI Conversion Command  
WRITE ADDRESS  
BYTE 1: DEVICE ADDRESS  
WRITE REGISTER NUMBER  
BYTE 2: FIRST REG NUMBER = N  
WRITE DATA  
BYTE 3: REG(N)[7:0] DATA  
START  
STOP  
SDA  
SCL  
1
0
0
1
0
A1 A0  
W
A
N
N
N
N
N
N
N
N
A
D
D
D
D
D
D
D
D
A
2
Figure 22. I C Single Register Write Sequence  
WRITE REGISTER NUMBER  
BYTE 2: REG NUMBER = N  
WRITE DATA  
BYTE 3: REG(N)[7:0] DATA  
WRITE DATA  
BYTE 5: REG(Z)[7:0] DATA  
WRITE ADDRESS  
BYTE 1: DEVICE ADDRESS  
WRITE REGISTER NUMBER  
BYTE 4: REG NUMBER = Z  
START  
STOP  
SDA  
SCL  
1
0
0
1
0
A1 A0  
W
A
N
N
N
N
N
N
N
N
A
D
D
D
D
D
D
D
D
A
Z
Z
Z
Z
Z
Z
Z
Z
A
D
D
D
D
D
D
D
D
A
2
Figure 23. I C Multiple Register Write Sequence  
40 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
I2C Configuration or Result Register Read  
(MAX11801/MAX11803)  
Streamlined I2C Read Operations (MAX11801/  
MAX11803)  
The read sequence does not limit the number of bytes to  
be read. The internal register counter keeps increment-  
ing as additional bytes are requested. The first byte out  
is Reg(N) as shown in Figure 24. The next byte out is  
Reg(N+1). The next byte out is Reg(N+2), and so on.  
The programmer needs to keep track of the incremented  
register address. Acknowledge pulses from the master  
are not required to autoincrement the internal register  
location. The internal register location updates on each  
byte. See the Command and Register Map section for  
details governing the incrementing of register addresses.  
The MAX11801/MAX11803 support several streamlined  
readback behavior to significantly improve data transfer  
efficiency. Using the streamlined readback sequence  
shown in Figure 25, data readback can commence fol-  
lowing an assumed progression. Disable the stream-  
lined readback feature to allow full readback sequence.  
Resumed Read Operations (MAX11801/  
MAX11803)  
When readback operations are suspended and later  
resume from the current (incremented) register loca-  
tion, it is not necessary to supply the initial device  
address and register start sequence. Begin the read-  
back portion of the command following the streamlined  
sequence shown in Figure 25 to allow more efficient  
data transfer.  
The autoincrement reads only the X, Y, Z1, Z2, and  
AUX result registers preventing inadvertent readback of  
unrelated or reserved data locations. For example, if  
beginning at the XMSB register, a user can cycle  
through the XLSB register to the YMSB register and so  
forth up to the AUXLSB register. The MAX11801/  
MAX11803 do not autoincrement beyond the AUXLSB  
register. If clock cycles continue to be given, the  
AUXLSB register readback is repeated.  
For example, if the user accesses the FIFO register  
(MAX11801), which does not autoincrement, and reads  
several observations and then stops and resumes the  
readback operation at a later time, the user only needs  
to issue the streamlined readback sequence to contin-  
ue to gather observations from the FIFO. Once the  
device is placed in autonomous mode, the user only  
needs to issue the full readback sequence once for the  
initial FIFO access. Then streamlined read access to  
the device resumes at the FIFO location, unless an  
intervening command is issued as shown in Figure 25.  
The FIFO (MAX11801) register does not autoincrement,  
which allows multiple readbacks of the same location.  
This allows the access to multiple FIFO memory blocks  
with a single read operation. When reading back FIFO  
registers, data management is handled in blocks not  
bytes. As a result, when an I2C read operation supplies  
at least one cycle for readback of the first byte of a FIFO  
block, the entire block is marked as read. This is regard-  
less of whether the block or even byte readback is run  
to completion.  
Similarly, when reading back result registers, begin with  
XMSB and autoincrement to XLSB, then stop. When  
readback resumes by the issuance of the streamlined  
readback sequence, data readback commences from  
the YMSB location.  
WRITE ADDRESS  
BYTE 1: DEVICE ADDRESS  
WRITE REGISTER START NUMBER  
BYTE 2: FIRST REG NUMBER = N  
REPEATED  
START  
WRITE ADDRESS  
BYTE 3: DEVICE ADDRESS  
READ DATA  
BYTE 4: REG(N)[7:0] DATA  
READ DATA  
START  
READ DATA (LAST BYTE)  
STOP  
ADDITONAL  
SEQUENTIAL READ  
DATA BYTES  
SDA  
SCL  
1
0
0
1
0
A1 A0  
W
A
N
N
N
N
N
N
N
N
A
1
0
0
1
0
A1 A0  
R
A
D
D
D
D
D
D
D
D
A
D
D
D
D
D
D
D
D
~A  
2
ACKNOWLEDGE GENERATED BY I C MASTER  
ACKNOWLEDGE GENERATED BY MAX11801/MAX11803  
2
Figure 24. I C Multiple Register Read Sequence  
WRITE ADDRESS  
BYTE 3: DEVICE ADDRESS  
READ DATA  
BYTE 4: REG(N)[7:0] DATA  
READ DATA  
START  
READ DATA (LAST BYTE)  
STOP  
SDA  
ADDITONAL  
SEQUENTIAL READ  
DATA BYTES  
1
0
0
1
0
A1 A0  
R
A
D
D
D
D
D
D
D
D
A
D
D
D
D
D
D
D
D
~A  
SCL  
2
ACKNOWLEDGE GENERATED BY MAX11801/MAX11803  
ACKNOWLEDGE GENERATED BY I C MASTER  
Figure 25. I2C Streamlined Register Read Sequence  
______________________________________________________________________________________ 41  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Direct Conversion Read Operations (MAX11801/  
MAX11803)  
are being executed is ignored and the readback target  
register is not modified.  
In direct conversion mode, commands automatically  
set the readback target register and streamline data  
gathering. See the Command and Register Maps sec-  
tion for specific details for all such commands. The  
MAX11801/MAX11803 automatically set the default  
readback register to the XMSB location when a com-  
mand requesting is received and a XY combined mea-  
surement is received. If the XY command is issued and  
allowed to complete, the device can then be followed  
directly by a streamlined read sequence and data  
readback commences from the XMSB register.  
Accepted direct conversion commands always modify  
the current internal register location and effectively  
override the resumed readback behaviors and any reg-  
ister settings made in response to previously complet-  
ed direct conversion commands.  
Command and Register Map  
The command map consists of the user-configuration reg-  
isters (read/write), TSC data readback commands (read  
only), and TSC panel setup and conversion commands  
(write only).  
User-Accessible Registers  
There are six blocks of user-accessible registers and  
commands that control all operations of the  
MAX11800–MAX11803. The register blocks and com-  
mands consist of the following:  
1) Status and Configuration Registers: 00h to 0Bh  
• Sets modes of operation––ACM or DCM  
• Settings to accommodate various panel sizes  
(panel time constant)  
Read Operations Following Write Operations  
(MAX11801/MAX11803)  
• Averaging and noise settings  
• Measurement resolution  
Data readback commences from the last written register  
location when the streamlined readback sequence is  
issued following a configuration write operation. When  
modifying the contents of the operating mode configura-  
tion register (0x0B) using a write sequence, then issuing  
a streamlined readback sequence, the contents of regis-  
ter 0x0B are provided. Register write operations always  
modify the current internal register location and effectively  
override the resumed readback behaviors.  
–MAX1803  
• Auxiliary settings  
• General part status reporting  
2) FIFO Data Readback Command: 50h  
• Autonomous conversion mode only (MAX11800/  
MAX11801)  
• Allows reading FIFO contents when operating in  
ACM  
3) Data Readback Commands: 52h to 5Bh  
I2C Conversion Command (MAX11801/MAX11803)  
Figure 26 shows the required command format for issu-  
ing conversion requests. A conversion request cannot  
be paired with multiple commands or instructions. Any  
conversion command issued while previous commands  
• Direct conversion mode only (MAX11800/  
MAX11802)  
• Allows reading measurement results when in DCM  
WRITE ADDRESS  
BYTE 1: DEVICE ADDRESS  
START  
STOP  
CONVERSION COMMAND  
SDA  
SCL  
1
0
0
1
0
A1 A0  
W
A
N
N
N
N
N
N
N
N
A
Figure 26. I2C Conversion Command  
42 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
2
2
4) I C Readback Registers: 52h to 58h  
position. For I C, the protocol is always 8-bit byte fol-  
lowed by an acknowledge bit, for a total of 9 bits. The  
• Direct conversion mode only (MAX11801/  
MAX11803)  
2
2
MSB in I C format is always 0. In write mode, for I C,  
the MSB is ignored internal to the MAX11800–  
MAX11803, so setting it to 0 or 1 has no effect.  
• Allows reading measurement results when in DCM  
5) Panel Setup Commands: 6Ah to 6Fh  
Status and Configuration Registers  
The status and configuration registers are located in  
block 0x00 to 0x0B. See Table 18. All user-configura-  
tion register write mode operations are pairable within  
• Sets up panel prior to making X, Y, Z1, or Z2 mea-  
surements  
6) Measurement Commands: 70h to 7Fh  
2
the SPI/I C interface. Multiple locations can be written  
• Performs specified measurement (X, Y, Z1, and/or  
Z2)  
under a single instruction with a register byte followed  
by a data. All user-configuration read-mode operations  
support autoincrement. For example, if location 0x00 is  
read back and more clock pulses are issued, readback  
will proceed through location 0x01 and so forth. The  
user should set all configuration registers to the desired  
values before issuing direct conversion operations or  
placing MAX11800/MAX11801 in autonomous mode.  
The commands to read or write the user-accessible  
registers are always the same. However, the data for-  
2
mat varies based on whether using an SPI or I C inter-  
face. Tables 16 and 17 show the differences between  
2
SPI and I C protocols. For SPI, the R/W bit is embed-  
ded in the 8-bit byte and always occupies the LSB  
Table 16. SPI Command and Data Format: 8 Bits  
BYTE  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
R3  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
R/W  
1/0  
R0  
(CONT)  
R6  
R5  
R4  
R2  
R1  
Command or Data  
2
Table 17. I C Command and Data Format: 8 Bits Plus ACK  
BYTE  
ACK  
BIT  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
R1  
BIT 0  
R0  
(CONT)  
0
R6  
R5  
R4  
R3  
R2  
1/0  
1/0  
Command or Data  
______________________________________________________________________________________ 43  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Table 18. Status and Configuration Registers  
DATA  
LENGTH  
HEX R6 R5 R4 R3 R2 R1 R0 ACCESS PAIRABLE AUTOINCREMENT  
FUNCTION  
General status  
00h  
01h  
0
0
0
0
0
0
0
0
0
0
0
0
0
1
R
No  
Yes  
Yes  
8
8
R/W  
Yes  
General configuration  
Measurement resolution  
configuration  
02h  
03h  
04h  
05h  
06h  
07h  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
8
8
8
8
8
8
Measurement averaging  
configuration  
ADC sample time  
configuration  
Panel setup times  
configuration  
ADC delay initial conversion  
configuration  
Touch-detect pullup times  
configuration  
–MAX1803  
Autonomous mode timing  
configuration (MAX11800/  
MAX11801)  
08h  
09h  
0
0
0
0
0
0
1
1
0
0
0
0
0
1
R/W  
R/W  
Yes  
Yes  
Yes  
Yes  
8
8
Aperture settings (auto)  
configuration (MAX11800/  
MAX11801)  
Auxiliary measurement  
configuration  
0Ah  
0Bh  
0
0
0
0
0
0
1
1
0
0
1
1
0
1
R/W  
R/W  
Yes  
Yes  
Yes  
Yes  
8
8
Operating mode  
configuration  
conversion mode (AUTO = 0). Random data access is  
supported within this register space and the commands  
autoincrement up to register 0x5B. The register  
address does not advance beyond register 0x5B.  
Attempting to read back a pending conversion results  
in data being tagged invalid. See the Direct Conversion  
Mode Operations section for more details.  
Data Readback Commands  
Autonomous Conversion Mode  
Use the readback command 0x50 to read back available  
FIFO data in autonomous conversion modes (AUTO = 1)  
(MAX11800/MAX11801). The oldest available data is  
read out first. Data blocks vary from 32 to 64 bits in  
length, depending on the scan mode selected. Reading  
back longer than one block results in reading back the  
next available block. The end-of-file indicator is read  
back when no unread data is available in the FIFO. This  
command does not autoincrement and the register  
address does not advance beyond 0x50. See the FIFO  
Data Block Readback Structure section for more details.  
The panel setup and conversion commands are not  
pairable in write mode as each command modifies the  
panel setting both during and after the command,  
based on conversion executions and CONT bit set-  
tings. All direct conversion commands modify the  
2
expected I C read register location to support the data  
streamlining protocol. Table 21 shows the resulting  
read register settings by command type applicable to  
Direct Conversion Mode  
Use the readback commands 0x52 to 0x5B to read  
back available measurement data gathered in direct  
2
I C variants.  
44 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Table 19. FIFO Data Readback Command (Autonomous Mode Only––MAX11800/MAX11801)  
DATA  
LENGTH  
HEX  
R6  
R5  
R4  
R3  
R2  
R1  
R0 ACCESS AUTOINCREMENT  
OPERATION  
Read next available FIFO  
data block  
50h  
1
0
1
0
0
0
X
Read  
No  
INF  
Table 20. Data Readback Commands (Direct Mode Only)  
DATA  
LENGTH  
HEX R6  
R5 R4 R3 R2 R1 R0 ACCESS AUTOINCREMENT  
OPERATION  
52h  
53h  
54h  
55h  
56h  
57h  
58h  
59h  
5Ah  
5Bh  
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
0
0
1
1
1
1
0
0
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Read  
Read  
Read  
Read  
Read  
Read  
Read  
Read  
Read  
Read  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
8
8
8
8
8
8
8
8
8
8
X = MSB (direct conversion result)  
X = LSB (direct conversion result)  
Y = MSB (direct conversion result)  
Y = LSB (direct conversion result)  
Z1 = MSB (direct conversion result)  
Z1 = LSB (direct conversion result)  
Z2 = MSB (direct conversion result)  
Z2 = LSB (direct conversion result)  
AUX MSB (direct conversion result)  
AUX LSB (direct conversion result)  
0
1
2
Table 21. I C Readback Register Settings Following Conversion Commands  
COMMAND  
X = panel setup  
READBACK REGISTER LOCATION  
DESCRIPTION  
52h  
X = MSB  
Y = panel setup  
Z1 = panel setup  
54h  
56h  
Y = MSB  
Z1 = MSB  
Z2 = panel setup  
58h  
52h  
52h  
52h  
5Ah  
52h  
54h  
56h  
58h  
Z2 = MSB  
X = MSB  
X = MSB  
X = MSB  
AUX = MSB  
X = MSB  
Y = MSB  
Z1 = MSB  
Z2 = MSB  
X, Y = combined command  
X, Y, Z1 = combined command  
X, Y, Z1, Z2 = combined command  
AUX = conversion  
X = measurement  
Y = measurement  
Z1 = measurement  
Z2 = measurement  
______________________________________________________________________________________ 45  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
CONT bit impacts the setup of the panel and ADC fol-  
lowing the command. For panel setup commands and  
combined commands, the user setting of this bit (R0) is  
ignored. For these commands, the internal assumption  
is shown in parentheses in Table 22.  
Panel Setup and  
Measurement Commands  
TSC conversion commands are only to be used in  
direct conversion mode (AUTO = 0). Conversion com-  
mands issued during autonomous mode are ignored.  
All panel setup and measurement operations are auto-  
mated when in autonomous mode (AUTO = 1).  
The CONT bit impacts the setup of the panel and/or ADC  
following the command (see command descriptions for  
details). For some commands, the user setting of this bit  
(R0) is ignored; for these commands the internal  
assumption is shown in parentheses in Tables 8 and 22.  
Commands must be issued in write mode to be execut-  
ed. There are two types of commands: panel setup reg-  
isters (0x6x) and measurement/conversion registers  
(0x7x). All measurement commands indicate that the  
ADC is used and the ADC can begin to power up once  
the 0x7x header has been recognized. All measure-  
ment commands modify the target data register upon  
the conclusion of the measurement command. The  
By definition, panel setup and measurement com-  
mands are NOT pairable in write mode as each com-  
mand modifies the panel setting both during the  
command and after it (based on conversion executions  
and CONT bit settings).  
Table 22. Measurement Commands  
COMMAND  
LENGTH  
HEX R6 R5 R4 R3 R2 R1  
R0  
ACCESS PAIRABLE  
OPERATION  
–MAX1803  
7xh  
1
1
1
0
0
0
(0)  
Write  
No  
8
X, Y = combined measurement  
7xh  
7xh  
1
1
1
1
1
1
0
0
0
1
1
0
(0)  
(0)  
Write  
Write  
No  
No  
8
8
X, Y, Z1 = combined measurement  
X, Y, Z1, Z2 = combined measurement  
7xh  
7xh  
7xh  
7xh  
7xh  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
0
0
1
1
1
0
1
0
1
(0)  
Write  
Write  
Write  
Write  
Write  
No  
No  
No  
No  
No  
8
8
8
8
8
AUX = measurement  
X = measurement  
Y = measurement  
Z1 = measurement  
Z2 = measurement  
CONT  
CONT  
CONT  
CONT  
46 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
User Configuration Registers  
General Status Register (0x00) (Read Only)  
BIT 7  
ADC_BUSY  
0
BIT 6  
LPM  
0
BIT 5  
TDM  
0
BIT 4  
SCAN  
0
BIT 3  
FIFO_OVR  
0
BIT 2  
FIFO_INT  
0
BIT 1  
EDGE_INT  
0
BIT 0  
CONT_INT  
0
NAME  
DEFAULT  
BIT  
NAME  
DESCRIPTION  
0: ADC is not in ACQ or CONV state  
1: ADC is in ACQ or CONV state  
This is for INTERNAL TEST only  
7
ADC_BUSY  
0: Device is not in LPM or standby mode  
1: Device is in LPM or standby mode  
6
5
LPM  
TDM  
0: Device is not in TDM  
1: Device is in TDM  
0: No scan or measurement in progress  
1: Scan or measurement in progress  
Also indicates presence of a continuous touch in autonomous mode  
4
3
2
1
0
SCAN  
0: FIFO overflow has not occurred (MAX11800/MAX11801)  
1: FIFO has overflowed since last readback operation  
Enabled only if AUTO = 1  
FIFO_OVR  
FIFO_INT  
EDGE_INT  
CONT_INT  
0: No unread data in FIFO (MAX11800/MAX11801)  
1: New data available in FIFO  
Enabled only if AUTO = 1  
0: No touch event in progress  
1: Touch event in progress (cleared on ETAG = 10)  
Enabled only if AUTO = 0 and EDGE_IRQ = 1  
0: No touch present  
1: Touch present (or conversion in progress)  
Enabled only if AUTO = 0 and EDGE_IRQ = 0  
______________________________________________________________________________________ 47  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
General Configuration Register (0x01)  
BIT 7  
RT_SEL  
1
BIT 6  
HOLD_DO  
1
BIT 5  
PU_IRQ  
1
BIT 4  
ODN_IRQ  
1
BIT 3  
MASK_IRQ  
0
BIT 2  
EDGE_IRQ  
0
BIT 1  
BIT 0  
NAME  
EDGE_TIME[1:0]  
DEFAULT  
0
0
BIT  
NAME  
DESCRIPTION  
0: 50ktouch-detection pullup resistance  
1: 100ktouch-detection pullup resistance  
7
RT_SEL  
(panel setting––not to be confused with internal TIRQ pullup)  
0: DOUT internal bus holder disabled  
1: DOUT internal bus holder enabled  
(applicable to SPI version only)  
6
5
HOLD_DO  
0: Disable IRQ internal pullup resistance  
1: Enable IRQ internal pullup resistance  
(open-drain mode only: ODN_IRQ also high)  
PU_IRQ  
0: TIRQ is CMOS buffered output  
1: TIRQ is open-drain nMOS output  
4
3
2
ODN_IRQ  
–MAX1803  
0: Enable TIRQ output  
1: Mask/disable TIRQ output (force high or high impedance)  
MASK_IRQ  
EDGE_IRQ  
0: Use continuous interrupt with direct conversion mode  
1: Use edge interrupt with direct conversion mode  
TIRQ low time for edge interrupt mode only  
00: 4 x (2MHz oscillator clock period) = 2μs  
01: 16 x (2MHz oscillator clock period) = 8μs  
10: 64 x (2MHz oscillator clock period) = 32μs  
11: 128 x (2MHz oscillator clock period) = 128μs  
1:0  
EDGE_TIME[1:0]  
Measurement Resolution Configuration Register (0x02)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
PWR_SAV  
0
BIT 3  
RESX  
0
BIT 2  
RESY  
0
BIT 1  
RESZ1  
0
BIT 0  
RESZ2  
0
NAME  
DEFAULT  
0
0
0
BIT  
NAME  
DESCRIPTION  
0: Internal ADC runs at normal power  
1: Internal ADC runs at reduced power and resolution  
This mode does limit the effective ADC resolution:  
12-bit conversions may be reduced to 10-bit accuracy  
8-bit conversions should not be impacted.  
Resolution for X, Y, Z1, or Z2 measurements  
0: 12-bit conversion (see the PWR_SAV description in this table)  
1: 8-bit conversion  
4
PWR_SAV  
RES_  
3:0  
48 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Measurement Averaging Configuration Register (0x03)*  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
AVG_X[1:0]  
AVG_Y[1:0]  
AVG_Z1[1:0]  
AVG_Z2[1:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
Averaging sample depth for X, Y, Z1, or Z2 measurements  
If AVG_FLT = 0 (see the Operating Mode Configuration Register (0x0B) section)  
00: Single sample, no averaging  
01: Take four samples, average two median samples  
10: Take eight samples, average four median samples  
11: Take 16 samples, average eight median samples  
If AVG_FLT = 1 (see the Operating Mode Configuration Register (0x0B) section)  
00: Single sample, no averaging  
7:6  
AVG_X[1:0]  
AVG_Y[1:0]  
AVG_Z1[1:0]  
AVG_Z2[1:0]  
5:4  
3:2  
1:0  
01: Take four samples, average all samples  
10: Take eight samples, average all samples  
11: Take 16 samples, average all samples  
*The settings can be enabled and disabled through settings in the operating mode configuration register (0x0B), allowing for dynamic  
configuration of averaging modes depending on operating mode.  
ADC Sampling Time Configuration Register (0x04)*  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
T_SAMPLE_X[1:0]  
T_SAMPLE_Y[1:0]  
T_SAMPLE_Z1[1:0]  
T_SAMPLE_Z2[1:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
7:6  
T_SAMPLE_X[1:0]  
T_SAMPLE_Y[1:0]  
T_SAMPLE_Z1[1:0]  
T_SAMPLE_Z2[1:0]  
Sampling time for X, Y, Z1 or Z2 measurements  
00: 4 x (2MHz oscillator clock period) = 2μs  
01: 16 x (2MHz oscillator clock period) = 8μs  
10: 64 x (2MHz oscillator clock period) = 32μs  
11: 256 x (2MHz oscillator clock period) = 128μs  
5:4  
3:2  
1:0  
*Time ADC spends sampling panel before starting conversion process. This time plus the ADC conversion time determines the sam-  
pling rate within averaging operations. Be sure to allow adequate time to settle the ADC capacitors given the panel effective source  
resistance.  
______________________________________________________________________________________ 49  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Panel Setup Timing Configuration Register (0x05)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
PSUXY[3:0]  
PSUZ[3:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
X, Y panel setup times (position measurements)  
0000: 0μs  
1000: 1ms  
0001: 20μs  
0010: 50μs  
0011: 80μs  
0100: 100μs  
0101: 200μs  
0110: 500μs  
0111: 800μs  
1001: 2ms  
1010: 5ms  
7:4  
PSUXY[3:0]  
1011: 10ms  
1100: 20ms  
1101: 50ms  
1110: 100ms  
1111: 200ms  
Z panel setup times (pressure measurements)  
PSUZ[3:0] has the same range as PSUXY[3:0] above.  
3:0  
PSUZ[3:0]  
Note: These settings apply to measurement commands, combined commands, and autonomous conversion mode measurements  
and provide time for the panel to settle prior to beginning measurements. During these periods, the panel is set up, but the ADC  
remains powered down. Users with low-impedance/fast settling panels should use setting 0000 (skip mode) if their panel can be set-  
tled during the required 10μs minimum delayed conversion time (see the Delayed Conversion Configuration Register (0x06) section).  
–MAX1803  
Delayed Conversion Configuration Register (0x06)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
D_CV_XY[3:0]  
D_CV_Z[3:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
X, Y panel plus ADC setup times (position measurements)  
0000: 10μs  
0001: 20μs  
0010: 50μs  
0011: 80μs  
0100: 100μs  
0101: 200μs  
0110: 500μs  
0111: 800μs  
1000: 1ms  
1001: 2ms  
1010: 5ms  
1011: 10ms  
1100: 20ms  
1101: 50ms  
1110: 100ms  
1111: 200ms  
7:4  
D_CV_XY[3:0]  
Z panel plus ADC setup times (pressure measurements)  
D_CV_Z[3:0] has the same range as D_CV_XY[3:0] above.  
3:0  
D_CV_Z[3:0]  
Note: These settings apply to measurement commands, combined commands, and autonomous conversion mode measurements  
and provide time for the panel and ADC to settle prior to beginning measurements. During these periods, the panel is set up and the  
ADC is powered up. In general, users with long panel settling requirements should minimize time in this mode, using increased  
panel setup times instead to save ADC power.  
50 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Touch-Detect Pullup Timing Configuration Register (0x07)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
PUR[3:0]  
PUF[3:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
Rough pullup time (t  
0000: 2μs*  
0001: 2μs  
)
PUR  
1000: 1ms  
1001: 2ms  
1010: 5ms  
0010: 4μs  
7:4  
PUR[3:0]  
0011: 8μs  
1011: 10ms  
1100: 20ms  
1101: 50ms  
1110: 100ms  
1111: 200ms  
0100: 10μs  
0101: 50μs  
0110: 100μs  
0111: 500μs  
Fine pullup time (t  
0000: 10μs  
)
PUF  
1000: 1ms  
0001: 20μs  
1001: 2ms  
0010: 50μs  
1010: 5ms  
3:0  
PUF[3:0]  
0011: 80μs  
1011: 10ms  
1100: 20ms  
1101: 50ms  
1110: 100ms  
1111: 200ms  
0100: 100μs  
0101: 200μs  
0110: 500μs  
0111: 800μs  
Note: These settings apply to the end of all measurement and combined commands and are required for proper data tagging and  
interrupt management. The exception is direct conversion commands with CONT = 1. These commands do not enter PUR/PUF inter-  
vals for the purpose of data tagging.  
*While 2μs is the minimum PUR interval listed, for this setting, the XPSW is not engaged, allowing for minimal power operation  
(essentially adding 2μs to the PUF time).  
Autonomous Mode Timing Configuration Register (0x08) (MAX11800/MAX11801)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
TINIT[3:0]  
SCANP[3:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
Initial period (time between touch and initial scan block, t  
)
INIT  
0000: 10μs  
0001: 20μs  
0010: 50μs  
0011: 80μs  
0100: 100μs  
0101: 200μs  
0110: 500μs  
0111: 800μs  
1000: 1ms  
1001: 2ms  
1010: 5ms  
1011: 10ms  
1100: 20ms  
1101: 50ms  
1110: 100ms  
1111: 200ms  
7:4  
TINIT[3:0]  
Scan period (time between successive scan blocks, t  
SCANP[3:0] has the same range as TINIT[3:0] above.  
)
SP  
3:0  
SCANP[3:0]  
Note: These settings apply in autonomous conversion mode only.  
______________________________________________________________________________________ 51  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Aperture Configuration Register (0x09) (MAX11800/MAX11801)  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
NAME  
APRX[3:0]  
APRY[3:0]  
DEFAULT  
0
0
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
ΔX for aperture checking  
0000 = 2-1 LSB = aperture checking disabled  
0001 = 2(1-1) LSB = 1 LSB  
0010 = 2(2-1) LSB = 2 LSB  
0011 = 2(3-1) LSB = 4 LSB  
.
7:4  
APRX[3:0]  
APRY[3:0]  
.
.
1001 = 2(9-1) LSB = 256 LSB  
1010 = 2(10-1) LSB = 512 LSB  
1011 = 2(11-1) LSB = 1024 LSB  
1100 = 2(12-1) LSB = 2048 LSB  
1101 to 1111 = aperture checking disabled  
–MAX1803  
ΔY for aperture checking  
APRY[3:0] has the same range as APRX[3:0] above.  
3:0  
Note: These aperture settings apply in autonomous conversion mode only and control whether data meets the criteria for logging  
into the FIFO.  
52 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Auxiliary Measurement Configuration Register (0x0A)  
BIT 7  
BIT 6  
D_CV_A[3:0]  
0
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
RESA  
0
NAME  
T_SAMPLE_A[1:0]  
AVGA[1:0]  
DEFAULT  
0
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
Delay initial auxiliary conversion  
000: 10μs  
001: 100μs  
010: 500μs  
7:5  
D_CV_A[3:0]  
011: 1ms  
100: 5ms  
101: 10ms  
110: 50ms  
111: 100ms  
Sampling time for auxiliary measurements  
00: 4 x (2MHz oscillator clock period) = 2μs  
01: 16 x (2MHz oscillator clock period) = 8μs  
10: 64 x (2MHz oscillator clock period) = 32μs  
11: 256 x (2MHz oscillator clock period) = 128μs  
4:3  
T_SAMPLE_A[1:0]  
Averaging sample depth for auxiliary measurements  
If AVG_FLT = 0 (see the Operating Mode Configuration Register (0x0B) section)  
00: Single sample, no averaging  
01: Take four samples, average two median samples  
10: Take eight samples, average four median samples  
11: Take 16 samples, average eight median samples  
If AVG_FLT = 1 (see the Operating Mode Configuration Register (0x0B) section)  
00: Single sample, no averaging  
2:1  
AVGA[1:0]  
01: Take four samples, average all samples  
10: Take eight samples, average all samples  
11: Take 16 samples, average all samples  
Resolution for auxiliary measurements  
0: 12-bit conversion (see the description of PWR_SAV in the Measurement Resolution  
Configuration Register (0x02) section)  
0
RESA  
1: 8-bit conversion  
Note: A delimiter refers to the auxiliary input (AUX). Auxiliary measurements can only be requested in direct conversion modes.  
______________________________________________________________________________________ 53  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Operating Mode Configuration Register (0x0B)  
BIT 7  
PWRDN  
1
BIT 6  
BIT 5  
BIT 4  
APER  
0
BIT 3  
AVG_FLT  
0
BIT 2  
BIT 1  
BIT 0  
NAME  
AMODE[1:0]  
EN_AVG_XY EN_AVG_Z  
DEFAULT  
0
0
0
0
0
BIT  
NAME  
DESCRIPTION  
0: Device is powered up and operational in either a direct or autonomous conversion  
mode (see AMODE[1:0] below).  
7
PWRDN  
1: Device is powered down, OTP is held in reset  
00: Direct conversion mode (AUTO = 0) (MAX11800/MAX11801)  
01: Autonomous X and Y scan (AUTO = 1)  
10: Autonomous X, Y, Z1 scan (AUTO = 1)  
6:5  
4
AMODE[1:0]  
APER  
11: Autonomous X, Y, Z1, Z2 scan (AUTO = 1)  
0: Disregard aperture criteria (MAX11800/MAX11801)  
1: Enable aperture criteria (spatial filter)  
(applies to autonomous modes only)  
0: Use median averaging filters (ignore outliers)  
1: Use straight averaging filters  
3
2
AVG_FLT  
–MAX1803  
0: Disable (X, Y) position averaging in selected mode  
1: Enable (X, Y) position averaging in selected mode  
EN_AVG_XY  
0: Disable (Z1, Z2) pressure averaging in selected mode  
1: Enable (Z1, Z2) pressure averaging in selected mode  
1
0
EN_AVG_Z  
RESERVED  
Reserved bit.  
*Any write access to 0x0B initiates an internal reset pulse. This pulse clears the FIFO and all measurement memories.  
54 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
MAX11800/MAX11802 Typical Operating Circuit  
V
DD  
1μF  
TIRQ  
DIN  
0.1μF  
V
DD  
X+  
Y+  
GPIO  
DOUT  
CLK  
DIN  
HOST  
PROCESSOR  
MAX11800  
MAX11802  
CLK  
X-  
DOUT  
CS  
CS  
TOUCH SCREEN  
Y-  
AUX  
AUX INPUT  
GND  
MAX11801/MAX11803 Typical Operating Circuit  
V
DD  
1μF  
TIRQ  
SDA  
SCL  
A0  
0.1μF  
1.2kΩ  
1.2kΩ  
OPTIONAL  
GPIO  
V
DD  
X+  
Y+  
SDA  
SCL  
A0  
HOST  
PROCESSOR  
MAX11801  
MAX11803  
X-  
A1  
A1  
TOUCH SCREEN  
Y-  
AUX  
AUX INPUT  
GND  
______________________________________________________________________________________ 55  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
Pin Configurations  
TOP VIEW  
MAX11800/MAX11802  
CS  
9
CLK  
8
DIN  
7
1
3
2
4
A
B
TIRQ  
Y-  
10  
11  
6
5
DOUT  
AUX  
Y+  
X+  
CS  
AUX  
Y+  
MAX11800  
MAX11802  
CLK  
GND  
DOUT  
V
DD  
X-  
12  
4
*EP  
C
DIN  
Y-  
TIRQ  
X-  
1
2
3
WLP  
X+  
V
GND  
DD  
TQFN  
MAX11801/MAX11803  
–MAX1803  
A0  
9
SCL  
8
SDA  
7
1
3
2
4
A
B
TIRQ  
Y-  
10  
11  
6
A1  
AUX  
Y+  
X+  
A0  
AUX  
A1  
Y+  
5
4
MAX11801  
MAX11803  
SCL  
GND  
V
DD  
X-  
12  
*EP  
C
SDA  
Y-  
TIRQ  
X-  
1
2
3
WLP  
X+  
V
GND  
DD  
TQFN  
*EXPOSED PAD.  
Package Information  
Chip Information  
For the latest package outline information and land patterns,  
go to www.maxim-ic.com/packages. Note that a “+”, “#”, or  
“-” in the package code indicates RoHS status only. Package  
drawings may show a different suffix character, but the drawing  
pertains to the package regardless of RoHS status.  
PROCESS: CMOS  
PACKAGE TYPE PACKAGE CODE DOCUMENT NO.  
12 TQFN  
12 WLP  
T1244+4  
21-0139  
21-0009  
W121A2-1  
56 ______________________________________________________________________________________  
Low-Power, Ultra-Small Resistive Touch-Screen  
2
Controllers with I C/SPI Interface  
–MAX1803  
Revision History  
REVISION REVISION  
PAGES  
CHANGED  
DESCRIPTION  
NUMBER  
DATE  
0
7/09  
Initial release.  
1
Removed future status from the WLP packages in the Ordering Information table.  
Added a new Note 1 about the WLP package to the Absolute Maximum Ratings  
section.  
8
14, 56  
8
1
2
11/09  
3/10  
Corrected the pin names for the WLP packages in the Pin Description table and Pin  
Configurations.  
Added “Soldering Temperature (reflow) at +260°C.” in the Absolute Maximum  
Ratings section.  
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are  
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.  
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 57  
© 2010 Maxim Integrated Products  
Maxim is a registered trademark of Maxim Integrated Products, Inc.  

相关型号:

MAX11801EWC+T

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11801GTC/V+

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11801TEVS+

Direct Conversion Mode Demonstration Capability
MAXIM

MAX11802

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11802ETC

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11802ETC+

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11802ETC+T

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11802EWC+T

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11803

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11803ETC

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11803ETC+

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM

MAX11803ETC+T

Low-Power, Ultra-Small Resistive Touch-Screen Controllers with I2C/SPI Interface
MAXIM