HRP-150N-48 [MEANWELL]

150W Single Output wi th PFC Funct ion;
HRP-150N-48
型号: HRP-150N-48
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

150W Single Output wi th PFC Funct ion

功率因数校正
文件: 总5页 (文件大小:161K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
150W Single Output with PFC Function  
HRP-150N series  
Bauart gepruft  
Sicherheit  
egelma ge  
od  
o s  
be wac  
g
www.tuv.com  
ID 2000000000  
AS/NZS 62368.1  
EN62368-1  
TPTC004 IEC62368-1  
Features  
Applications  
Universal AC input / Full range  
Industrial automation machinery  
Industrial control system  
Built-in active PFC function, PF>0.95  
250% peak power capability  
High efficiency up to 89%  
Mechanical and electrical equipment  
Diagnostic or biological facilities  
Test or measurement systems  
Telecommunication equipment  
Withstand 300VAC surge input for 5 seconds  
Protections: Short circuit / Overload / Over voltage /  
Over temperature  
Cooling by free air convection  
1U low profile 38mm  
Built-in remote sense function  
5 years warranty  
Description  
HRP-150N is a 150W single output type AC/DC power supply. This series operates for 85~264VAC input  
voltage and offers the models with the DC output mostly demanded from the industry. Each model is  
cooled by free air convection, working for the temperature up to 70without cover. Moreover, HRP-150N  
provides 250% short-duration peak power for motor applications and electromechanical loads requiring  
much higher power during start-up.  
Model Encoding  
HRP - 150N - 24  
Output voltage(12/24/36/48V)  
Rated wattage  
Series name  
File Name:HRP-150N-SPEC 2020-11-03  
150W Single Output with PFC Function  
HRP-150N series  
SPECIFICATION  
MODEL  
HRP-150N-36  
HRP-150N-12  
HRP-150N-24  
HRP-150N-48  
DC VOLTAGE  
12V  
24V  
36V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
13A  
6.5A  
4.3A  
3.3A  
0 ~ 6.5A  
0 ~ 4.3A  
154.8W  
200mVp-p  
28.8 ~ 39.6V  
1.5%  
0 ~ 3.3A  
158.4W  
240mVp-p  
40.8 ~ 55.2V  
1.5%  
0 ~ 13A  
156W  
156W  
RIPPLE & NOISE (max.) Note.2 120mVp-p  
150mVp-p  
OUTPUT  
VOLTAGE ADJ. RANGE  
VOLTAGE TOLERANCE Note.3  
LINE REGULATION  
10.2 ~ 13.8V  
21.6 ~ 28.8V  
1.5%  
1.5%  
0.2%  
0.2%  
0.2%  
0.3%  
LOAD REGULATION  
SETUP, RISE TIME  
0.5%  
0.5%  
0.5%  
0.5%  
3000ms, 50ms/230VAC  
3000ms, 50ms/115VAC at full load  
HOLD UP TIME (Typ.)  
16ms/230VAC  
16ms/115VAC at full load  
120 ~ 370VDC  
VOLTAGE RANGE  
Note.4 85 ~ 264VAC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
47 ~ 63Hz  
PF>0.95/230VAC  
PF>0.98/115VAC at full load  
88%  
INPUT  
89%  
89%  
88%  
1.7A/115VAC  
35A/115VAC  
<1mA / 240VAC  
0.9A/230VAC  
70A/230VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
LEAKAGE CURRENT  
Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power  
on to recover  
OVERLOAD  
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power  
on to recover  
PROTECTION  
14.4 ~ 16.8V  
30 ~ 34.8V  
41.4 ~ 48.6V  
57.6 ~ 67.2V  
OVER VOLTAGE  
Protection type : Shut down o/p voltage, re-power on to recover  
Shut down o/p voltage, recovers automatically after temperature goes down  
-40 ~ +70(Refer to "Derating Curve")  
20 ~ 90% RH non-condensing  
OVER TEMPERATURE  
WORKING TEMP.  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
ENVIRONMENT  
-50 ~ +85, 10 ~ 95% RH  
0.04%/(0 ~ 50)  
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes  
OPERATING ALTITUDE Note.6 5000 meters  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
UL62368-1, TUV EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved  
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH  
Parameter  
Standard  
Test Level / Note  
Conducted  
EN55032  
Class B  
Class B  
Class A  
-----  
Radiated  
EN55032  
Harmonic current  
Voltage Flicker  
EN61000-3-2  
EN61000-3-3  
EMC EMISSION  
SAFETY &  
EMC  
EN55035 , EN61000-6-2(EN50082-2)  
(Note 5)  
Parameter  
ESD  
Standard  
Test Level / Note  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
Level 3, 8KV air; Level 2, 4KV contact  
Level 3, 10V/m  
RF field  
EFT/ Burst  
Surge  
Level 3, 2KV  
EMC IMMUNITY  
Level 4, 4KV/Line-FG; 2KV/Line-Line  
Level 3, 10V  
Conducted  
Magnetic Field  
Level 4, 30A/m  
95% dip 0.5 periods, 30% dip 25 periods,  
95% interruptions 250 periods  
Voltage Dips and Interruptions  
EN61000-4-11  
578.15K hrs min. Telcordia TR/SR-332 (Bellcore) ; 221.71K hrs min. MIL-HDBK-217F (25)  
MTBF  
OTHERS  
DIMENSION  
PACKING  
159*97*38mm (L*W*H)  
0.54Kg; 24pcs/12.96Kg/0.9CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. Derating may be needed under low input voltages. Please check the derating curve for more details.  
NOTE  
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on  
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to  
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)  
6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx  
File Name:HRP-150N-SPEC 2020-11-03  
150W Single Output with PFC Function  
HRP-150N series  
Block Diagram  
PWM fosc :90KHz  
+S  
ACTIVE  
INRUSH  
RECTIFIERS  
RECTIFIERS  
+V  
EMI  
FILTER  
POWER  
&
I/P  
&
CURRENT  
LIMITING  
SWITCHING  
-V  
PFC  
FILTER  
-S  
DETECTION  
CIRCUIT  
O.L.P.  
O.T.P.  
FG  
O.T.P.  
O.V.P.  
PFC  
PWM  
CONTROL  
CONTROL  
Derating Curve  
Output Derating VS Input Voltage  
100  
90  
80  
70  
60  
50  
40  
100  
80  
Without Cover  
60  
With Cover  
Normal load only  
40  
20  
-40  
-10  
0
10  
20  
30  
40  
50  
60  
70 (HORIZONTAL)  
85  
100  
125  
135  
155  
264  
AMBIENT TEMPERATURE ()  
INPUT VOLTAGE (V) 60Hz  
Function Manual  
1.Remote Sense  
The remote sensing compensates voltage drop on the  
load wiring up to 0.5V.  
-V -V +V +V  
CN100  
6 4 2  
5 3 1  
CN100  
NC  
NC  
NC  
NC  
+S  
-S  
6
5
2
1
Sense lines should  
be twisted in pairs  
LOAD  
+S  
(Pin2)  
-S  
(Pin1)  
-
+
Fig 1.1  
File Name:HRP-150N-SPEC 2020-11-03  
150W Single Output with PFC Function  
HRP-150N series  
2.Peak Power  
x
t
(T-t)  
35%  
x
+
Ppk  
Pnpk  
P
P
av : Average output power (W)  
Pav =  
Prated  
T
pk : Peak output power (W)  
npk : Non-peak output power(W)  
rated : Rated output power(W)  
t
Duty  
x
100%  
T
P
P
t
5 sec  
t : Peak power width(sec)  
T: Period(sec)  
Ppk  
Pav  
Pnpk  
t
T
125  
40  
35  
30  
25  
20  
15  
10  
5
200Vac (1s)  
100Vac (5s)  
200Vac (5s)  
154.8 175  
200  
225  
250  
275  
300  
325  
350  
375  
Peak output power (W)  
For example (12V model) :  
Vin = 100V Duty_max = 25%  
Pav= Prated = 156W  
Ppk= 300W  
t 5 sec  
T 20 sec  
x t  
x
(T-t)  
+
Ppk  
Pnpk  
T
300x5+ Pnpk (20-5)  
20  
Pav  
=
=
156W  
Pnpk 108W  
File Name:HRP-150N-SPEC 2020-11-03  
150W Single Output with PFC Function  
HRP-150N series  
Mechanical Specification  
Case No.901I  
Unit:mm  
152.5  
1
2
3
4
5
6
7
CN100  
SVR1  
4.5  
24  
78  
159  
6.5  
150  
6-M3(Both Sides) L=6  
10 max.  
22  
117  
Connector Pin No. Assignment (CN100) :  
Terminal Pin No. Assignment :  
Pin No. Assignment Pin No.  
HRS DF11-6DP-2DSA or equivalent  
Pin No. Assignment Mating Housing  
Assignment  
Terminal  
1
2
3
AC/L  
AC/N  
FG  
4,5  
6,7  
DC OUTPUT -V  
DC OUTPUT +V  
1
2
-S  
+S  
NC  
HRS DF11-6DS  
or equivalent  
HRS DF11-**SC  
or equivalent  
3~6  
Installation Manual  
Please refer to : http://www.meanwell.com/manual.html  
File Name:HRP-150N-SPEC 2020-11-03  

相关型号:

HRP-200

200W Single Output with PFC Function
MEANWELL

HRP-200-12

200W Single Output with PFC Function
MEANWELL

HRP-200-15

200W Single Output with PFC Function
MEANWELL

HRP-200-24

200W Single Output with PFC Function
MEANWELL

HRP-200-3.3

200W Single Output with PFC Function
MEANWELL

HRP-200-36

200W Single Output with PFC Function
MEANWELL

HRP-200-48

200W Single Output with PFC Function
MEANWELL

HRP-200-5

200W Single Output with PFC Function
MEANWELL

HRP-200-7.5

200W Single Output with PFC Function
MEANWELL

HRP-200_1012

200W Single Output with PFC Function
MEANWELL

HRP-200_11

200W Single Output with PFC Function
MEANWELL

HRP-300

300W Single Output with PFC Function
MEANWELL