HRP-300N-12 [MEANWELL]
300W Single Output with PFC Function;型号: | HRP-300N-12 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 300W Single Output with PFC Function 功率因数校正 |
文件: | 总5页 (文件大小:161K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
300W Single Output with PFC Function
HRP-300N series
Bauart gepruft
Sicherheit
egelma ge
od
o s
be wac
g
www.tuv.com
ID 2000000000
AS/NZS 62368.1
EN62368-1
TPTC004 IEC62368-1
■ Features
■ Applications
ꢀUniversal AC input / Full range
ꢀIndustrial automation machinery
ꢀIndustrial control system
ꢀBuilt-in active PFC function, PF>0.95
ꢀ250% peak power capability
ꢀHigh efficiency up to 89%
ꢀMechanical and electrical equipment
ꢀDiagnostic or biological facilities
ꢀTest or measurement systems
ꢀTelecommunication equipment
ꢀWithstand 300VAC surge input for 5 seconds
ꢀProtections: Short circuit / Overload / Over voltage /
Over temperature
ꢀ1U low profile 41mm
ꢀBuilt-in cooling fan ON-OFF control
ꢀBuilt-in DC OK signal
ꢀBuilt-in remote sense function
ꢀ5 years warranty
■ Description
HRP-300N is a 300W single output type AC/DC power supply. This series operates for 85~264VAC input
voltage and offers the models with the DC output mostly demanded from the industry. Each model is
cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70℃. Moreover,
HRP-300N provides 250% short-duration peak power for motor applications and electromechanical loads
requiring much higher power during start-up.
■ Model Encoding
HRP - 300N - 24
Output voltage(12/24/36/48V)
Rated wattage
Series name
File Name:HRP-300N-SPEC 2020-11-03
300W Single Output with PFC Function
HRP-300N series
SPECIFICATION
MODEL
HRP-300N-12
HRP-300N-24
HRP-300N-36
HRP-300N-48
DC VOLTAGE
12V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
27A
14A
9A
7A
0 ~ 27A
324W
0 ~ 14A
0 ~ 9A
0 ~ 7A
336W
324W
336W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 ± 1.0%
150mVp-p
250mVp-p
28.8 ~ 39.6V
± 1.0%
± 0.2%
± 0.5%
250mVp-p
40.8 ~ 55.2V
± 1.0%
± 0.2%
± 0.5%
OUTPUT
10.2 ~ 13.8V
21.6 ~ 28.8V
± 1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
± 0.3%
± 0.2%
± 0.5%
± 0.5%
1000ms, 50ms/230VAC
2500ms, 50ms/115VAC at full load
16ms/230VAC
Note.4 85 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.95/230VAC
88%
PF>0.99/115VAC at full load
87%
INPUT
88%
89%
3.5A/115VAC
1.8A/230VAC
75A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
35A/115VAC
<1.5mA / 240VAC
Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
OVERLOAD
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
PROTECTION
14.4 ~ 16.8V
30 ~ 34.8V
41.4 ~ 48.6V
57.6 ~ 67.2V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
Load 35± 15% or RTH2ꢁ50℃ Fan on
OVER TEMPERATURE
DC OK SIGNAL
FUNCTION
FAN CONTROL (Typ.)
WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85℃, 10 ~ 95% RH
± 0.03%±℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL62368-1, TUV EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Parameter
Standard
Test Level / Note
Conducted
EN55032
Class B
Class B
Class A
-----
Radiated
EN55032
Harmonic current
Voltage Flicker
EN61000-3-2
EN61000-3-3
EMC EMISSION
SAFETY &
EN55035 , EN61000-6-2(EN50082-2)
EMC
Parameter
ESD
Standard
Test Level / Note
(Note 5)
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air; Level 2, 4KV contact
Level 3, 10V/m
RF field
EFT/ Burst
Surge
Level 3, 2KV
EMC IMMUNITY
Level 4, 4KV/Line-FG; 2KV/Line-Line
Level 3, 10V
Conducted
Magnetic Field
Level 4, 30A/m
95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
529.1K hrs min. Telcordia TR/SR-332 (Bellcore) ; 201.43K hrs min. MIL-HDBK-217F (25℃)
OTHERS
DIMENSION
PACKING
199*105*41mm (L*W*H)
0.9Kg;15pcs/14.5Kg/0.84CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
NOTE
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HRP-300N-SPEC 2020-11-03
300W Single Output with PFC Function
HRP-300N series
Block Diagram
PWM fosc : 70KHz
+S
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
RECTIFIERS
+V
EMI
FILTER
POWER
&
I/P
&
SWITCHING
-V
PFC
FILTER
-S
O.L.P.
DC OK
O.T.P.
DETECTION
CIRCUIT
FG
PFC
PWM
O.V.P.
CONTROL
CONTROL
Derating Curve
Output Derating VS Input Voltage
100
90
80
70
60
50
40
100
80
60
50
40
Normal load only
20
85
100
125
135
155
264
-40
-10
0
10
20
30
40
50
60
70 (HORIZONTAL)
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE (℃)
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
CN100
CN100
2
3
4
5
6
7
1
NC DC-OK GND +S
NC NC NC -S
1
2
7
8
1
7
2
8
+S
-S
(Pin8)
LOAD
(Pin7)
Sense lines should
be twisted in pairs
+
Fig 1.1
File Name:HRP-300N-SPEC 2020-11-03
300W Single Output with PFC Function
HRP-300N series
2.DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin3) and GND(pin5) Output Status
3.3 ~ 5.6V
0 ~ 1V
ON
OFF
CN100
CN100
7
2
3
4
5
6
1
NC DC-OK GND +S
NC NC NC -S
1
2
7
8
1
7
2
8
Fig 2.1
3.Peak Power
x
t
(T-t)
35%
x
+
Ppk
Pnpk
P
P
av : Average output power (W)
pk : Peak output power (W)
Pav =
≤
Prated
T
t
Duty
x
100%
≤
T
P
P
npk : Non-peak output power(W)
rated : Rated output power(W)
t
≤
5 sec
t : Peak power width(sec)
T: Period(sec)
Ppk
Pav
Pnpk
t
T
125
40
35
30
25
20
15
10
5
200Vac (1s)
100Vac (5s)
200Vac (5s)
324
350
400
450
500
550
600
650
700
750
Peak output power (W)
For example (12V model) :
Vin = 100V Duty_max = 35%
Pav= Prated = 324W
Ppk= 600W
t ≤ 5 sec
T ꢁ 14.29 sec
x t
x
(T-t)
+
Ppk
Pnpk
T
600x5+Pnpk (14.29-5)
Pav
=
=
≤324W
14.29
Pnpk ≤ 175.4W
File Name:HRP-300N-SPEC 2020-11-03
300W Single Output with PFC Function
HRP-300N series
Mechanical Specification
Case No.980A
Unit:mm
4-M4 L=6
12.25
168.5
199
12.25
168.5
120
42.5
1
2
3
4
5
6
7
4-M4 L=5
FAN
Air flow
direction
LED
CN100
SVR
167.5
167.5
12.25
12.25
17max.
4-M4 L=6
Terminal Pin No. Assignment
Pin No. Assignment Pin No.
Connector Pin No. Assignment (CN100) :
HRS DF11-08DP-2DS or equivalent
Pin No. Assignment Mating Housing
Assignment
1
2
3
AC/L
AC/N
FG
4,5
6,7
DC OUTPUT -V
Terminal
DC OUTPUT +V
1,2,4,6
NC
DC-OK
GND
+S
3
5
7
8
HRS DF11-8DS
or equivalent
HRS DF11-**SC
or equivalent
-S
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:HRP-300N-SPEC 2020-11-03
相关型号:
©2020 ICPDF网 联系我们和版权申明