MHB75-24S12 [MEANWELL]

75W DC-DC Half-Brick Regulated Single Output Converter; 75W DC-DC半砖稳压单路输出转换器
MHB75-24S12
型号: MHB75-24S12
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

75W DC-DC Half-Brick Regulated Single Output Converter
75W DC-DC半砖稳压单路输出转换器

转换器
文件: 总6页 (文件大小:839K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
Features :  
Half-brick size (2.28" 2.4" 0.5") with industry standard pin out  
2:1 wide input range  
Protections: Short circuit / Over current / Over voltage / Over temperature  
High efficiency up to 89%  
1500VDC I/O isolation  
Built-in remote ON/OFF control  
Built-in remote sense function  
Trimming output 10%  
Five-sided shield metal case  
Optional heat sinks for extended operating temperature  
Output 2.5V/3.3V/15V available  
Approvals: UL / CUL / CE  
3 years warranty  
SPECIFICATION  
MODEL  
MHB75-12S05 MHB75-12S12 MHB75-12S24 MHB75-24S05 MHB75-24S12 MHB75-24S24 MHB75-48S05 MHB75-48S12 MHB75-48S24  
DC VOLTAGE  
5V  
12V  
24V  
5V  
12V  
24V  
5V  
12V  
24V  
CURRENT RANGE  
RATED POWER  
0 ~ 15A  
75W  
0 ~ 6.25A  
0 ~ 3.13A  
0 ~ 15A  
0 ~ 6.25A  
0 ~ 3.13A  
0 ~ 15A  
0 ~ 6.25A  
0 ~ 3.13A  
RIPPLE & NOISE (max.) Note.2 75mVp-p  
100mVp-p  
240mVp-p  
75mVp-p  
100mVp-p  
240mVp-p  
75mVp-p  
100mVp-p  
240mVp-p  
VOLTAGE ACCURACY Note.3  
LINE REGULATION  
1.0%  
0.2%  
0.2%  
OUTPUT  
LOAD REGULATION  
SWITCHING FREQUENCY (Typ.) 400KHz for 12/24Vin, 300KHz for 48Vin  
EXTERNAL TRIM ADJ. RANGE (Typ.) 10%  
EXTERNAL CAPACITIVE LOAD (max.) 10000uF  
10000uF  
2000uF  
10000uF  
24VDC  
10000uF  
2000uF  
10000uF  
48VDC  
10000uF  
2000uF  
RATED DC INPUT  
VOLTAGE RANGE  
12VDC  
9 ~ 18VDC  
18 ~ 36VDC  
50VDC  
36 ~ 75VDC  
100VDC  
SURGE VOLTAGE (100ms max.) 25VDC  
UNDER VOLTAGE LOCKOUT Power up: 8.8VDC, Power down: 8VDC  
Power up: 17VDC, Power down: 16VDC  
Power up: 34VDC, Power down: 32.5VDC  
INPUT  
83%  
EFFICIENCY (Typ.)  
FULL LOAD  
DC CURRENT  
87%  
87%  
84%  
88%  
88%  
84%  
89%  
89%  
7570mA  
50mA  
7200mA  
7200mA  
3780mA  
50mA  
3650mA  
3650mA  
1900mA  
50mA  
1800mA  
1800mA  
NO LOAD  
FILTER  
Pi-network  
110 ~ 150% rated output power  
OUTPUT OVER CURRENT  
Protection type : Over current limiting, recovers automatically after fault condition is removed  
115 ~ 140% rated output voltage  
OUTPUT OVER VOLTAGE (Typ.)  
PROTECTION  
Protection type : Output voltage clamp by TVS diode  
Protection type : Can be continuous, recovers automatically after fault condition is removed  
OUTPUT SHORT CIRCUIT  
OVER TEMPERATURE  
REMOTE CONTROL  
100  
5 of case temperature  
Please refer to "Remote ON/OFF Control" for details  
FUNCTION  
OPERATING  
10%, Please refer to "External Output Trimming" for details  
OUTPUT TRIMMING  
-40 ~ +100 ; Thermal shutdown at 100  
0% ~ 95% RH max.  
5 of case temperature (please refer to "Thermal Curve")  
WORKING TEMPERATURE (Typ.)  
WORKING HUMIDITY  
ENVIRONMENT  
STORAGE TEMP., HUMIDITY -55 ~ +105 , 0 ~ 95% RH  
TEMP. COEFFICIENT  
SAFETY STANDARDS  
ISOLATION VOLTAGE  
0.03%/ (0~60  
UL60950-1 approved  
I/P-O/P:1500VDC, I/P-Case:1500VDC, O/P-Case:1500VDC  
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH  
SAFETY &  
ISOLATION RESISTANCE  
EMC EMISSION  
EMC  
(Note 4)  
Compliance to EN55022 (CISPR22) Class A with external components (please refer to "EMC Suggestion Circuit")  
Compliance to EN61000-4-2,3,4,5,6,8; EN55024, light industry level, criteria A  
Aluminum  
EMC IMMUNITY  
CASE MATERIAL  
MTBF  
1000K hrs typ. MIL-HDBK-217F (25  
)
OTHERS  
NOTE  
DIMENSION  
WEIGHT  
57.9*61*12.7mm (2.28"*2.40"*0.5") (L*W*H)  
92g  
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 1uf ceramic & 10uf tantalum capacitor across output.  
3. The power supply need to connect "+Vout" to "+R.S" and "-Vout" to "-R.S".  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
File Name:MHB75-SPEC 2011-09-08  
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
Mechanical Specification  
Unit:inch[mm]  
All Dimensions In Inches [mm]  
Tolerance Inches: X.XX= 0.02 , X.XXX= 0.010  
Millimeters: X.X= 0.5 , X.XX= 0.25  
0.18 min.  
[4.6]  
0.50  
[12.7]  
Mounting Inserts M3*0.5  
R1.50  
BOTTOM VIEW  
4
3
5
6
7
2
1
8
9
SIDE VIEW  
1.90  
[48.3]  
2.28  
[57.9]  
Pin No. Assignment  
Assignment  
+Vin  
Assignment  
-Vin  
Assignment  
Trim  
Pin No.  
Pin No.  
Pin No.  
7
8
1
2
4
5
+R.S.  
R.C.  
-Vout  
-R.S.  
Case  
3
6
+Vout  
9
Remote ON/OFF Control  
The MHB75 series allow the user to switch the power ON and OFF electronically by their remote ON/OFF feature.  
The MHB75 series are available with "Positive Logic" (standard) or "Negative Logic" (option).  
Logic table  
Logic State(pin2)  
Positive logic  
Negative logic  
Logic Low-Switch Closed Power OFF(<0.8Vdc)  
Power ON(<0.8Vdc)  
Logic High-Switch Open Power ON(Open circuit) Power OFF(Open circuit)  
Note: 1.Logic compatibility : R.C.(pin2) ~ -Vin(pin4).  
2.Suffix "N" to the model number with Negative logic remote ON/OFF.  
R.C.(pin2)  
MHB75  
High singal here  
disable output  
-Vin(pin4)  
Example control circuit(positive logic)  
File Name:MHB75-SPEC 2011-09-08  
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
External Output Trimming  
+Vin  
(pin1)  
+Vout  
(pin9)  
+Vin  
(pin1)  
+Vout  
(pin9)  
RTrim-down  
Trim  
(pin7)  
Trim  
(pin7)  
MHB75  
MHB75  
R-Load  
RTrim-up  
R-Load  
-Vin  
(pin4)  
-Vout  
(pin5)  
-Vin  
(pin4)  
-Vout  
(pin5)  
Figure 1 : Trim-up voltage setup  
Figure 2 : Trim-down voltage setup  
The value of RTrim-up defined as:  
(R1-R2 (Vo-Vo, nom))  
The value of RTrim-down defined as:  
(R1-R2 (Vo, nom-Vo))  
(K  
)
(K )  
=
=
RTrim-up  
RTrim-down  
(Vo-Vo, nom)  
(Vo, nom-Vo)  
Where: RTrim-up is the external resistor in Kohm.  
Where: RTrim-down is the external resistor in Kohm.  
Vo,nom is the nominal output voltage.  
Vo is the desired output voltage.  
Vo,nom is the nominal output voltage.  
Vo is the desired output voltage.  
R1 and R2 are inside the unit and list in Table 1  
R1 and R2 are inside the unit and list in Table 2.  
Output  
Voltage(V)  
R1  
(Kohm)  
R2  
(Kohm)  
Output  
Voltage(V)  
R1  
(Kohm)  
R2  
(Kohm)  
5V  
12V  
24V  
5.8  
8.25  
5V  
12V  
24V  
5.8  
86.45  
430  
10.57  
60.1  
130  
19.656  
42.215  
13.304  
16.923  
Table 1  
Table 2  
For example, to Trim-up the output  
voltage of 5.0V model (MHB75-48S05)  
by 8% to 5.4V, RTrim-up is calculated  
For example, to Trim-down the output  
Voltage of 5.0V model (MHB75-48S05)  
by 8% to 4.6V, RTrim-down is  
as follows:  
calculated as follows :  
Vo - Vo,nom = 5.4 -5.0 = 0.4V  
Vo,nom - Vo = 5.0 - 4.6 = 0.4 V  
R1 = 5.8 Kohm  
R2 = 8.25 Kohm  
R1 = 5.8 Kohm  
R2 = 10.57 Kohm  
5.8-8.25 0.4  
5.8-10.57 0.4  
RTrim-up=  
= 6.25 (K  
)
RTrim-down =  
= 3.93 (K )  
0.4  
0.4  
File Name:MHB75-SPEC 2011-09-08  
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
Thermal Curve  
The operating case temperature range of MHB-75 series is -40oC to +100oC. When operate the MHB-75 series, proper de-rating or  
cooling is needed.  
The maximum case temperature under any operating condition should not be exceed 100oC. The following curve is the de-rating  
curve of MHB-75 series without heat sink.  
Power Dissipated vs Ambient Temperature and Air Flow without heatsink  
50  
Natural Convection  
20 ft./min. (0.1 m/s)  
45  
100 ft./min. (0.5 m/s)  
40  
200 ft./min. (1.0 m/s)  
300 ft./min. (1.5 m/s)  
35  
30  
400 ft./min. (2.0 m/s)  
500 ft./min. (2.5 m/s)  
600 ft./min. (3.0 m/s)  
700 ft./min. (3.5 m/s)  
800 ft./min. (4.0 m/s)  
25  
20  
15  
10  
5
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
(
)
Ambient Temperature, Ta  
Air Flow Rate  
Typical Rca  
7.12 / W  
Air Flow Rate  
Typical Rca  
2.96 / W  
Natural convection  
20ft./min. (0.1m/s)  
100 ft./min. (0.5m/s)  
500 ft./min. (2.5m/s)  
Rca : Thermal resistance from case to  
ambience  
6.21 / W  
5.17 / W  
4.29 / W  
3.64 / W  
600 ft./min. (3.0m/s)  
700 ft./min. (3.5m/s)  
800 ft./min. (4.0m/s)  
2.53 / W  
2.37 / W  
2.19 / W  
200 ft./min. (1.0m/s)  
300 ft./min. (1.5m/s)  
400 ft./min. (2.0m/s)  
Example:  
What is the minimum airflow necessary for a MHB75-48S12 operates at nominal line, an output current of 6.25A, and a maximum ambient  
temperature of 40  
Solution:  
?
Given: Vin=48Vdc, Vo=12Vdc, Io=6.25A, (unit efficiency)=89%  
Determine Power dissipation (Pd):  
Pd=Pi-Po=Po(1- )/  
Pd=12 6.25 (1-0.89)/0.89=9.27 Watts  
Determine airflow:  
Given: Pd=9.27W and Ta=40  
Check Thermal Curve above:  
minimum airflow= 100 ft./min.  
Verifying: The maximum temperature rise T = Pd Rca=9.27 6.21=57.57  
The maximum case temperature Tc=Ta+ T=97.57 <100  
Where: The Rca is thermal resistance from case to ambience.  
The Ta is ambient temperature and the Tc is case temperature.  
File Name:MHB75-SPEC 2011-09-08  
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
Case Heat Sink (Optional)  
Unit:mm  
Model No.: M-C308 (Vertical Fins)  
Model No.: M-C091(Horizontal Fins)  
Model No.: M-C092 (Horizontal Fins)  
61  
61  
58  
48.20  
50.8  
50.8  
2.-8.50  
8-2  
5.-7.80  
R1  
CR0.3  
0.30  
Rca:  
Rca:  
Rca:  
3.90 / W (typ.), at natural convection  
1.74 / W (typ.), at 100ft./min.(LFM)  
1.33 / W (typ.), at 200ft./min.(LFM)  
1.12 / W (typ.), at 300ft./min.(LFM)  
0.97 / W (typ.), at 400ft./min.(LFM)  
4.70 / W (typ.), at natural convection  
2.89 / W (typ.), at 100ft./min.(LFM)  
2.30 / W (typ.), at 200ft./min.(LFM)  
1.88 / W (typ.), at 300ft./min.(LFM)  
1.59 / W (typ.), at 400ft./min.(LFM)  
3.00 / W (typ.), at natural convection  
1.44 / W (typ.), at 100ft./min.(LFM)  
1.17 / W (typ.), at 200ft./min.(LFM)  
1.04 / W (typ.), at 300ft./min.(LFM)  
0.95 / W (typ.), at 400ft./min.(LFM)  
File Name:MHB75-SPEC 2011-09-08  
75W DC-DC Half-Brick Regulated Single Output Converter  
MHB75 series  
Heatsink Assembly  
Screw  
Washer  
Heat Sink  
Thermal Pad or suitable  
thermal grease  
Heat Sink Order No.:  
M-C308  
1
M-C091  
2
M-C092  
3
Thermal Pad: 56.9x60x0.25mm  
Screw: SMP+SW M3x8L  
4
EMC Suggestion Circuit  
Required external components to meet EN55022 class A conducted emission are as below:  
L1  
+Vin  
+Vout  
+Vin  
+Vout  
-Vout  
MHB75  
Case  
Lo ad  
C1  
C2  
-Vin  
-Vout  
-Vin  
C3  
Model No.  
C1  
C2  
C3  
L1  
100uF/50V  
ESR<0.33  
100uF/50V  
ESR<0.33  
1000pF  
MHB75-12S  
1.5uH  
1.5uH  
100uF/50V  
ESR<0.33  
100uF/50V  
ESR<0.33  
1000pF  
2200pF  
MHB75-24S  
33uF/100V  
ESR<0.46  
33uF/100V  
ESR<0.46  
MHB75-48S  
=05,12,24  
8.3uH  
File Name:MHB75-SPEC 2011-09-08  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY