75W Single Output Industrial DIN RAIL
NDR-75 series
Bauart gepruft
Sicherheit
egelma ge
od o s
be wac g
www.tuv.com
ID 2000000000
■
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■
℃℃
■
File Name:NDR-75-SPEC 2015-10-29
75W Single Output Industrial DIN RAIL
NDR-75 series
SPECIFICATION
MODEL
NDR-75-12
NDR-75-24
NDR-75-48
DC VOLTAGE
RATED CURRENT
12V
24V
48V
6.3A
3.2A
1.6A
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
0 ~ 6.3A
75.6W
80mVp-p
12 ~ 14V
±2.0%
0 ~ 3.2A
0 ~ 1.6A
76.8W
150mVp-p
48 ~ 55V
±1.0%
±0.5%
±1.0%
76.8W
120mVp-p
OUTPUT
24 ~ 28V
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
LOAD REGULATION
SETUP, RISE TIME
1200ms, 60ms/230VAC
2000ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC
12ms/115VAC at full load
127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
Note.6 90 ~ 264VAC
47 ~ 63Hz
85.5%
88%
89%
INPUT
1.45A/115VAC
20A/115VAC
<1mA / 240VAC
0.9A/230VAC
35A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
OVERLOAD
14 ~ 17V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
ENVIRONMENT
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
VIBRATION
SAFETY STANDARDS
Ul508, TUV EN60950-1 approved;(meet EN60204-1)
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A
486.2K hrs min. MIL-HDBK-217F (25℃)
SAFETY &
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC
(Note 4)
EMC IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
32*125.2*102mm (W*H*D)
0.51Kg; 28pcs/15.3Kg/1.22CUFT
℃
File Name:EDR-75-SPEC 2015-10-29
75W Single Output Industrial DIN RAIL
NDR-75 series
Block Diagram
fosc : 85KHz
RECTIFIERS
EMI FILTER
&
POWER
+V
-V
I/P
FG
&
SWITCHING
RECTIFIERS
FILTER
O.C.P.
O.L.P.
O.T.P.
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
230VAC
100
90
80
70
60
50
40
Others
100
80
115VAC
60
50
12V(115VAC only)
40
20
-20 -10
0
10
20
30
40 45 50
60
70 (VERTICAL)
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE (℃)
File Name:NDR-75-SPEC 2015-10-29
75W Single Output Industrial DIN RAIL
NDR-75 series
Mechanical Specification
Case No.221B
Unit:mm
Top View
102
35
1 2 3 4
TB2
(12V,24V only)
DC OK
+V ADJ.
(48V only)
TB1
1 2 3
Side View
Front View
Side View
Terminal Pin No. Assignment (TB1)
Pin No. Assignment
1
2
3
FG
AC/N or DC -
AC/L or DC +
Terminal Pin No. Assignment (TB2)
Pin No. Assignment
1,2
3,4
DC OUTPUT -V
DC OUTPUT+V
Bottom View
Installation Instruction
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the USER MANUAL on
http://www.meanwell.com/search/NDR-75/NDR_manual.pdf
ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)