NED-75A [MEANWELL]
75W Dual Output Switching Power Supply; 75W双路输出开关电源型号: | NED-75A |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 75W Dual Output Switching Power Supply |
文件: | 总2页 (文件大小:382K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
75W Dual Output Switching Power Supply
NED-75 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NED-75A
NED-75B
OUTPUT NUMBER
CH1
5V
CH2
12V
CH1
CH2
24V
DC VOLTAGE
5V
RATED CURRENT
CURRENT RANGE
RATED POWER
7A
3A
5A
2A
Note.6 1 ~ 8A
71W
0.3 ~ 4A
1 ~ 6A
73W
0.2 ~ 3A
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 1.5%
120mVp-p
80mVp-p
CH1: 4.75 ~ 5.5V
2.0%
200mVp-p
OUTPUT
CH1: 4.75 ~ 5.5V
6.0%
6.0%
1.0%
3.0%
1.0%
0.5%
3.0%
1.5%
SETUP, RISE TIME
500ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
10ms/115VAC at full load
85 ~ 264VAC
47 ~ 63Hz
78%
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
81%
INPUT
1.5A/115VAC
0.9A/230VAC
COLD START 45A
<2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
EMC
(Note 7)
381.3K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.52Kg; 30pcs/16.6Kg/0.97CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:NED-75-SPEC 2011-08-17
75W Dual Output Switching Power Supply
NED-75 series
Mechanical Specification
Case No. 901 Unit:mm
152.5
1
2
3
4
5
6
3
M
-
2
7
+V ADJ.
4.5
24
78
159
150
6.5
Terminal Pin No. Assignment
Pin No.
Assignment
AC/L
Pin No.
Assignment
1
2
3
4
5
6
7
DC OUTPUT +V2
DC OUTPUT COM
DC OUTPUT +V1
AC/N
FG
DC OUTPUT COM
22
117
Block Diagram
fosc : 60KHz
+V2
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
EMI
FILTER
POWER
SWITCHING
+V1
I/P
FG
COM
DETECTION
CIRCUIT
CONTROL
O.L.P.
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
90
100
80
80
60
70
60
40
50
40
20
-20
0
10
20
30
40
50
60
70
(HORIZONTAL)
85 95 100 115 120 140 160 180 200 220 240 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:NED-75-SPEC 2011-08-17
相关型号:
©2020 ICPDF网 联系我们和版权申明