RCP-2000-48 [MEANWELL]

2000W Front End Power Supply;
RCP-2000-48
型号: RCP-2000-48
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

2000W Front End Power Supply

文件: 总5页 (文件大小:291K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
2000W Front End Power Supply  
RCP-2000 series  
Features :  
Universal AC input / Full range  
Built-in 5V/0.3A, 12V/0.8A auxiliary power  
Built-in active PFC function, PF>0.98  
High efficiency up to 92%  
Withstand 300VAC surge input for 5 seconds  
Protections: Short circuit / Overload / Over voltage / Over temperature  
High Power density 21.4W/inch3  
Forced air cooling by built-in DC fan with fan speed control  
Low profile:1U height  
Remote control for single unit  
Built-in remote sense function  
Output voltage trimming function  
Hot-swap operation  
PMBus serial communication  
AC OK, DC OK signal, fan fail, OTP alarm signal  
Internal OR-ing FET  
3 years warranty  
Description :  
The RCP-2000 series are state of the art AC/DC frond-end rectifiers with 1U compact size and 21.4 W/in3 of high power density. They can  
provide up to 2000W per unit for the applications of servers, information technology equipment, networking, telecommunications, and wide  
range of industrial applications using distributed power architecture. Equipped with hot-swap function and PMBus communication protocol,  
RCP-2000 can be assembled in 1U 19” rack and controlled/monitored by external device such as monitoring unit (RCP-CMU-1) or PC.  
SPECIFICATION - Single Unit  
MODEL  
RCP-2000-12  
RCP-2000-24  
RCP-2000-48  
DC VOLTAGE  
12V  
24V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
100A  
80A  
42A  
0 ~ 100A  
1200W  
0 ~ 80A  
1920W  
200mVp-p  
21 ~ 28V  
1.0%  
0 ~ 42A  
2016W  
300mVp-p  
42 ~ 56V  
1.0%  
RIPPLE & NOISE (max.) Note.2 150mVp-p  
VOLTAGE ADJ. RANGE 10.5 ~ 14V  
VOLTAGE TOLERANCE Note.3 2.0%  
OUTPUT  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
HOLD UP TIME (Typ.)  
1.0%  
0.5%  
0.5%  
1.0%  
0.5%  
0.5%  
1500ms, 60ms/230VAC at full load  
16ms/230VAC at 75% load  
10ms/230VAC at full load  
VOLTAGE RANGE  
Note.5 90 ~ 264VAC 127 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
47 ~ 63Hz  
0.98/230VAC at full load  
86%  
90.5%  
92%  
INPUT  
13A/115VAC  
7A/230VAC  
16A/115VAC  
10A/230VAC  
16A/115VAC  
10A/230VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
COLD START 50A  
<1.1mA / 230VAC  
LEAKAGE CURRENT  
105 ~ 125% rated output power  
OVERLOAD  
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover  
14.7 ~ 17.5V  
29.5 ~ 35V 57.6 ~ 67.2V  
Protection type : Shut down o/p voltage, re-power on to recover  
80 (TSW1) detect on heatsink of power bridge 85 (TSW2) detect on heatsink of o/p diode  
OVER VOLTAGE  
PROTECTION  
5
5
OVER TEMPERATURE  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
5V @ 0.3A, 12V @ 0.8A  
AUXILIARY POWER  
By electrical signal or dry contact ON:short OFF:open  
Compensate voltage drop on the load wiring up to 0.5V  
The isolated TTL signal out, refer to function manual  
The isolated TTL signal out, refer to function manual  
Adjustment of output voltage, possible between 90 ~ 110% of rated output  
Logic " High" for over temperature warning, refer to function manual, isolated signal  
The isolated TTL signal out, refer to function manual  
-40 ~ +70 (Refer to "Derating Curve")  
REMOTE ON/OFF CONTROL  
REMOTE SENSE  
DC OK SIGNAL  
FUNCTION  
AC OK SIGNAL  
OUTPUT VOLTAGE TRIM  
OVER TEMP WARNING  
FAN FAIL SIGNAL  
WORKING TEMP.  
20 ~ 90% RH non-condensing  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
-40 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT  
TEMP. COEFFICIENT  
VIBRATION  
0.03%/ (0 ~ 50  
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
File Name:RCP-2000-SPEC 2011-05-09  
2000W Front End Power Supply  
RCP-2000 series  
MODEL  
RCP-2000-12  
RCP-2000-24  
RCP-2000-48  
SAFETY STANDARDS  
UL60950-1, TUV EN60950-1 approved  
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.7KVDC  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
EMC EMISSION  
EMC IMMUNITY  
MTBF  
SAFETY &  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH  
EMC  
(Note 4)  
Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A  
60.1Khrs min. MIL-HDBK-217F (25  
295*127*41mm (L*W*H)  
)
OTHERS  
NOTE  
DIMENSION  
2Kg;6pcs/13Kg/1.04CUFT  
PACKING  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives.  
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.  
6. Output of all the RCP-2000 modules are connected in parallel in the rack.  
7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition.  
It will go back to normal ripple level once the output load is more than 10%.  
Mechanical Specification (Single Unit)  
Case No. 974A  
Unit:mm  
295  
41  
24  
SVR1  
CN501  
Air flow  
direction  
1
2
3
4
5
6
7
8
9
33  
11 14 17 20 23 26 29  
12 15 18 21 24 27 30  
13 16 19 22 25 28 31  
10  
32  
34  
Input / Output Connector Pin No. Assignment(CN501) : Postronic PCIM34W13M400A1  
Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment  
Mating Housing  
+V  
-V  
DA  
DB  
+S  
-S  
ON/OFF  
A1  
NC  
SDA  
T-ALARM  
FAN-FAIL  
+5V-AUX  
+12V-AUX  
GND-AUX  
FG  
12  
17  
22  
27  
32  
1,2,3,4  
5,6,7,8  
9
AC/L  
AC/N  
13  
14  
15  
16  
18  
19  
20  
21  
23  
24  
25  
26  
28  
29  
30  
31  
33  
34  
Postronic  
PCIM34W13F400A1  
-V(signal)  
+V(signal)  
PV  
A2  
SCL  
A3  
AC-OK  
DC-OK  
10  
A0  
A4  
11  
File Name:RCP-2000-SPEC 2011-05-09  
2000W Front End Power Supply  
RCP-2000 series  
Block Diagram  
PFC fosc : 110KHz  
PWM fosc : 90KHz  
+S  
ACTIVE  
INRUSH  
CURRENT  
LIMITING  
ORING  
+V  
RECTIFIERS  
RECTIFIERS  
&
FILTER  
POWER  
SWITCHING  
EMI  
FILTER  
FET  
I/P  
&
PFC  
-V  
-S  
O.V.P.  
ORING FET  
CONTROL  
DETECTION  
CIRCUIT  
PWM  
CONTROL  
PFC  
CONTROL  
PV  
TRANSCEIVERS  
DA/DB  
T-Alarm  
DC-OK  
AC-OK  
FAN FAIL  
SDA/SCL  
DETECTION  
CIRCUIT  
MCU  
MCU  
DATA  
ISOLATION  
O.T.P.  
PM BUS  
FAN  
ON/OFF  
AUX  
POWER  
12V/0.8A  
AUX POWER  
5V/0.3A  
RECTIFIERS  
&
FILTER  
Function Description of CN501  
Pin No.  
1,2,3,4  
5,6,7,8  
9
Function  
+V  
Description  
Positive output voltage  
Negative output voltage.  
-V Signal  
-V  
-V  
10  
+V  
+V Signal  
11  
PV  
Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1)  
Differential digital signal for parallel control. (Note.1)  
12,13  
DA,DB  
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be  
twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.  
14  
15  
+S  
-S  
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be  
twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.  
16,18,19, A0,A1,A2,  
A3,A4  
PMBus interface address lines. (Note.1)  
20,21  
17  
ON/OFF The unit can turn the output on and off by electrical signal or dry contact. (Note.2)  
22  
NC  
SDA  
Not use.  
23  
Serial Data used in the PMBus interface. (Note.2)  
24  
SCL  
Serial Clock used in the PMBus interface. (Note.2)  
Low : When the input voltage is 87Vrms. High : when the input voltage in 75Vrms . (Note.2)  
High : When the Vout 80% 5%. Low : When Vout 80% 5%. (Note.2)  
25  
AC-OK  
DC-OK  
26  
High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.  
Low : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. (Note.2)  
27  
28  
29  
T-ALARM  
FAN-FAIL High : When the internal fan fail. Low : When the internal fan is normal. (Note.2)  
Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin 31). The maximum load current is 0.3A. This output has the  
built-in "Oring diodes" and is not controlled by the remote ON/OFF control.  
+5V-AUX  
Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 31). The maximum load current is 0.8A. This output has  
the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.  
30  
+12V-AUX  
31  
32  
33  
34  
GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).  
FG  
AC Ground connection.  
AC Line connection.  
AC/L  
AC/N  
AC Neutral connection.  
Note1: Non-isolated signal, referenced to the output terminals (-V).  
Note2: Isolated signal, referenced to GND-AUX.  
File Name:RCP-2000-SPEC 2011-05-09  
2000W Front End Power Supply  
RCP-2000 series  
Derating Curve  
Static Characteristics  
100  
90  
100  
80  
80  
75  
70  
230VAC  
Input only  
12V  
60  
50  
40  
65  
24V,48V  
50  
40  
20  
90  
100  
115  
180  
264  
(HORIZONTAL)  
-40  
-25 -10  
0
15  
30  
50  
60  
70  
AMBIENT TEMPERATURE (  
)
INPUT VOLTAGE (VAC) 60Hz  
EFFICIENCY vs LOAD (48V Model)  
DERATING LOAD(%) VS INPUT VOLTAGE  
INPUT / VOLTAGE  
94  
92  
90  
88  
86  
84  
82  
>180VAC  
115VAC  
100VAC  
90VAC  
MODEL  
100%  
100%  
95%  
80%  
90%  
75%  
80%  
65%  
RCP-2000-12  
RCP-2000-24  
RCP-2000-48  
100%  
80%  
75%  
65%  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
LOAD  
Function Manual  
1. Remote ON/OFF Control  
The PSU can be turned ON/OFF together or separately by using the "Remote ON/OFF" function.  
Between ON/OFF and +5V-AUX  
SW Open  
Output  
OFF  
ON  
17  
29  
ON/OFF  
RCP-2000  
SW  
+5V-AUX  
SW Short  
2. Voltage Drop Compensation  
2.1 Remote Sense  
The remote sense compensates voltage drop on the load wiring up to 0.5V.  
+V  
+S  
+V  
14  
15  
RCP-2000  
LOAD  
-S  
-V  
-V  
Sense lines should be twisted in pairs  
File Name:RCP-2000-SPEC 2011-05-09  
2000W Front End Power Supply  
RCP-2000 series  
2.2 Local Sense  
Notice : The +S,-S have to be connected to the +V,-V terminals locally in order to get the correct output voltage if the remote sensing is not used.  
+V  
14  
+S  
RCP-2000  
-V  
15  
-S  
3. Output Voltage Trimming  
Output voltage can be trimmed between 90~110% of its rated value by the following method.  
11  
PV  
0~5V  
RCP-2000  
9
-V Signal  
Add on 0~5V external voltage  
Vout  
110  
100  
90  
80  
70  
60  
V
0
0.5  
1.5  
3
4.5  
5
EXTERNAL VOLTAGE (DC)  
4. Front Panel Indicators & Corresponding Signal at Function Pins  
*
Function  
LED  
Signal  
PSU Output  
ON  
Description  
AC-OK GREEN  
0 ~ 0.5V  
4.5 ~ 5.5V  
0 ~ 0.5V  
When input voltage 87V  
When input voltage 75V  
AC-NG  
RED  
OFF  
ON  
DC-OK GREEN  
When output voltage 80% 5% of Vo rated.  
DC-NG  
T-OK  
RED  
4.5 ~ 5.5V  
0 ~ 0.5V  
When output voltage 80% 5% of Vo rated.  
ON  
GREEN  
When the internal temperature (TSW1 & TSW2 short) is within safe limit  
When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm  
ON  
T-ALARM RED  
4.5 ~ 5.5V  
OFF  
*Signal between function pin and "GND-AUX".  
File Name:RCP-2000-SPEC 2011-05-09  

相关型号:

RCP-26

CARD EJECTORS
RICHCO

RCP-29

CARD EJECTORS
RICHCO

RCP-36

CARD EJECTORS
RICHCO

RCP-39

CARD EJECTORS
RICHCO

RCP-3K1U-12

1000 ~ 3000W Front End Power System
MEANWELL

RCP-3K1U-24

1000 ~ 3000W Front End Power System
MEANWELL

RCP-3K1U-48

1000 ~ 3000W Front End Power System
MEANWELL

RCP-3K1UI-12

UNIVERSAL AC INPUT / FULL RANGE
MEANWELL

RCP-3K1UI-12-C

UNIVERSAL AC INPUT / FULL RANGE
MEANWELL

RCP-3K1UI-24

UNIVERSAL AC INPUT / FULL RANGE
MEANWELL

RCP-3K1UI-24-C

UNIVERSAL AC INPUT / FULL RANGE
MEANWELL

RCP-3K1UI-48

UNIVERSAL AC INPUT / FULL RANGE
MEANWELL