RDDW10H-05 [MEANWELL]

10W DIP Package Reliable Railway DC-DC Converter;
RDDW10H-05
型号: RDDW10H-05
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

10W DIP Package Reliable Railway DC-DC Converter

文件: 总5页 (文件大小:115K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
10W DIP Package Reliable Railway DC-DC Converter  
RSDW10 & RDDW10 series  
Applications  
Features  
Bus, tram, metro or railway system  
Telecom/datacom system  
Wireless network  
Compliance with EN50155 railway standard  
DIP 24 package with standard pinout  
4:1 wide input range  
Wide operating temperature range -40 ~ +85℃  
No minimum load required  
Industrial control facility  
Instrument  
Full encapsulated  
Analyzer  
Protections: Short circuit (Continuous) / Overload /  
Over voltage / Input under voltage  
3KVDC I/O isolation  
Highly vibrating, heavily dusty, exteremely  
low or high temperature harsh environment  
Remote ON/OFF control  
3 years warranty  
Description  
RSDW10 and RDDW10 series are 10W module type DC-DC reliable railway converter with DIP24 package.  
It features international standard pins, a high efficiency up to 88%, wide working temperature range  
-40~+85, 3KVDC I/P-O/P isolation voltage, compliance with EN50155 railway standard, continuous-mode  
short circuit protection, etc. The models account for 43~160V 4:1 wide input range, and various output  
voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for  
railway, trams, buses and also can be used in the harsh environment with high vibration, high dust,  
extremely low or high temperature, etc.  
Model Encoding  
R S DW10H  
-12  
Output voltage (3.3/5/12/15Vdc±5/±12/±15Vdc)  
Input voltage (H: 43~160Vdc)  
Rated wattage  
S:Single output  
D:Dual output  
Series name  
{
File Name:RSDW10,RDDW10-SPEC 2018-03-15  
10W DIP Package Reliable Railway DC-DC Converter  
RSDW10 & RDDW10 series  
MODEL SELECTION TABLE  
INPUT  
OUTPUT  
ORDER NO.  
INPUT CURRENT  
EFFICIENCY CAPACITOR LOAD  
OUTPUT  
INPUT VOLTAGE  
(RANGE)  
OUTPUT  
(Typ.)  
(MAX.)  
VOLTAGE  
CURRENT  
NO LOAD  
FULL LOAD  
RSDW10H-03  
RSDW10H-05  
RSDW10H-12  
RSDW10H-15  
RDDW10H-05  
RDDW10H-12  
RDDW10H-15  
6mA  
6mA  
6mA  
6mA  
6mA  
6mA  
6mA  
89mA  
3.3V  
2500mA  
85%  
87%  
87%  
88%  
85%  
87%  
88%  
2500μF  
2000μF  
835μF  
666μF  
1000μF  
416μF  
105mA  
104mA  
103mA  
107mA  
105mA  
104mA  
5V  
2000mA  
835mA  
12V  
Normal 110V  
(43 ~ 160V)  
15V  
666mA  
± 5V  
± 12V  
± 15V  
± 0 ~1000mA  
± 0 ~416mA  
± 0 ~333mA  
333μF  
* For each output  
File Name:RSDW10,RDDW10-SPEC 2018-03-15  
10W DIP Package Reliable Railway DC-DC Converter  
RSDW10 & RDDW10 series  
SPECIFICATION  
VOLTAGE RANGE  
43~160Vdc  
SURGE VOLTAGE (100ms max.) 200Vdc  
FILTER  
PROTECTION (Typ.)  
Pi type  
INPUT  
Fuse recommended. 0.5A Fast acting type  
INTERNAL POWER DISSIPATION 500mW 0.5A fast acting type  
VOLTAGE ACCURACY  
RATED POWER  
± 1%  
10W  
RIPPLE & NOISE Note.2 50mVp-p  
LINE REGULATION Note.3 ± 0.2%  
OUTPUT  
LOAD REGULATION Note.4 Single output models: ± 0.5%, Dual output models:± 1%  
SWITCHING FREQUENCY (Typ.) 240KHz  
SHORT CIRCUIT  
Protection type : Continuous, automatic recovery  
120 ~ 180% rated output power  
OVERLOAD  
Protection type : Recovers automatically after fault condition is removed  
Protection type : Clamp by diode  
PROTECTION  
FUNCTION  
OVER VOLTAGE  
UNDER VOLTAGE LOCKOUT  
Start-up voltage  
40Vdc  
38Vdc  
Shutdown voltage  
REMOTE CONTROL  
COOLING  
Power ON: R.C. ~ -Vin >3.5~160Vdc or open circuit ; Power OFF: R.C. ~ -Vin <1.2Vdc or short  
Free-air convection  
-40 ~ +85(Refer to "Derating Curve")  
+100max.  
WORKING TEMP.  
CASE TEMPERATURE  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
SOLDERING TEMPERATURE  
VIBRATION  
20% ~ 90% RH non-condensing  
ENVIRONMENT  
-55 ~ +125, 10 ~ 95% RH non-condensing  
0.03% / (0 ~ 71)  
1.5mm from case of 1 ~ 3sec./260max.  
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: compliance to EN61373(Category 1- Class B)  
SAFETY STANDARDS  
EAC TP TC 004 approved  
I/P-O/P:3KVDC  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
ISOLATION CAPACITANCE (Typ.)  
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH  
1000pF  
Parameter  
Conducted  
Radiated  
Standard  
Test Level / Note  
EN55032  
Class A with external components  
N/A  
EMC EMISSION  
SAFETY &  
EN55032  
EMC  
( Note.5)  
Parameter  
ESD  
Standard  
Test Level / Note  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
Level 2, ± 8KV air, ± 4KV contact  
Level 2, 3V/m  
Radiated Susceptibility  
EFT/Burest  
Surge  
EMC IMMUNITY  
Level 1, 0.5KV  
Level 1, 0.5KV Line-Line  
Level 2, 3V(e.m.f.)  
Conducted  
EN50155 including EN61373 for shock & vibration, EN50121-3-2 for EMC  
1200Khrs MIL-HDBK-217F(25)  
31.8*20.3*12.7mm (1.25*0.8*0.5 inch)  
Non-Conductive black plastic  
RAILWAY STANDARD  
MTBF  
DIMENSION (L*W*H)  
CASE MATERIAL  
PACKING  
OTHERS  
16g  
1.All parameters are specified at normal input(110Vdc), rated load, 2570% RH ambient.  
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.  
3.Line regulation is measured from low line to high line at rated load.  
4.Load regulation is measured from 10% to 100% rated load.  
NOTE  
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please  
refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)  
File Name:RSDW10,RDDW10-SPEC 2018-03-15  
10W DIP Package Reliable Railway DC-DC Converter  
RSDW10 & RDDW10 series  
Mechanical Specification  
All dimensions in mm(inch)  
Tolerance:x.x± 0.5mm(x.xx± 0.02")  
x.xx± 0.25mm(x.xxx± 0.010")  
Pin size is:0.5± 0.05mm (0.02±± 0.002")  
1
23  
22  
2
3
0.5(0.02")  
Bottom View  
Side View  
16  
14  
9
11  
15.24(0.6)  
3.8(0.15)  
20.3(0.8)  
12.7(0.50)  
Plug Assignment  
Pin-Out  
RSDW10 RDDW10  
(Single output) (Dual output)  
Pin No.  
1
2,3  
9
Remote ON/OFF Remote ON/OFF  
-Vin  
N.P.  
-Vin  
Common  
-Vout  
11  
N.C.  
+Vout  
-Vout  
+Vin  
14  
+Vout  
16  
Common  
+Vin  
22,23  
Derating Curve  
100  
80  
50  
Natural convection  
40  
20  
-40  
-20  
0
20  
40  
60 65  
85  
100  
Ta ()  
File Name:RSDW10,RDDW10-SPEC 2018-03-15  
10W DIP Package Reliable Railway DC-DC Converter  
RSDW10 & RDDW10 series  
EMC Suggestion Circuit  
Required external components to meet EN55032 class A emission are as below:  
+Vin  
-Vin  
+Vout  
+Vin  
+Vout  
RSDW10  
RDDW10  
Lo ad  
C1  
C2  
-Vout  
-Vin  
-Vout  
EN55032 Class A  
C1  
Model No.  
C2  
RSDW10H-12  
RSDW10H-15  
RDDW10H-05  
RDDW10H-12  
RDDW10H-15  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
10μF/50V  
Note: All of capacitors are ceramic capacitors and 1812 size.  
Installation Manual  
Please refer to : http://www.meanwell.com/manual.html  
File Name:RSDW10,RDDW10-SPEC 2018-03-15  

相关型号:

RDDW10H-12

10W DIP Package Reliable Railway DC-DC Converter
MEANWELL

RDDW10H-15

10W DIP Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20F-05

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20F-12

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20F-15

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20G-05

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20G-12

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20G-15

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20H-12

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20H-15

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RDDW20UW

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL