RPT-60D [MEANWELL]
60W Triple Output Medical Type; 60W三路输出医用型型号: | RPT-60D |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 60W Triple Output Medical Type |
文件: | 总3页 (文件大小:777K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
60W Triple Output Medical Type
RPT-60 series
Features :
4"x2" miniature size
Universal AC input / Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Fixed switch frequency at 100KHz
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
RPT-60A
RPT-60B
RPT-60C
OUTPUT NUMBER
CH1
CH2
CH3
-5V
CH1
5V
CH2
CH3
-12V
0.5A
CH1
5V
CH2
15V
1.5A
CH3
-15V
0.5A
DC VOLTAGE
5V
12V
12V
RATED CURRENT
CURRENT RANGE
RATED POWER
4A
2A
0.5A
4A
2A
4A
0.5 ~ 4.4A
46.5W
0.1 ~ 2.2A
0.1 ~ 0.55A 0.5 ~ 4.4A
0.1 ~ 2.2A
0.1 ~ 0.55A 0.5 ~ 4.4A
0.1 ~ 1.65A 0.1 ~ 0.55A
50W
55W
50W
55W
PEAK LOAD(10sec.) Note.4 51.15W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 +3,-2%
OUTPUT
80mVp-p
6.0%
80mVp-p
+9,-8%
1.0%
80mVp-p
+3,-2%
0.5%
80mVp-p
6.0%
100mVp-p
+6,-10%
2.0%
80mVp-p
+3,-2%
0.5%
100mVp-p
6.0%
150mVp-p
8.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
1.5%
1.0%
1.0%
2.0%
2.0%
2.0%
+5,-7%
1.5%
2.0%
5.0%
1.5%
3.0%
4.0%
200ms, 15ms/230VAC
200ms, 15ms/115VAC at full load
15ms/115VAC at full load
127 ~ 370VDC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
70ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
77%
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
78%
79%
INPUT
1.1A/115VAC
0.7A/230VAC
30A/115VAC
COLD START 60A/230VAC
For earth <200uA/264VAC, For patient <100uA/264VAC
115 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
ENVIRONMENT
SAFETY &
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMC
(Note 5)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
MTBF
677.8Khrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
101.6*50.8*29mm (L*W*H)
0.15Kg; 96pcs/15.4Kg/0.89CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:RPT-60-SPEC 2008-03-25
60W Triple Output Medical Type
RPT-60 series
Features :
4"x2" miniature size
Universal AC input / Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Fixed switch frequency at 100KHz
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
RPT-60D
RPT-6003
OUTPUT NUMBER
CH1
CH2
CH3
CH1
CH2
5V
CH3
DC VOLTAGE
5V
24V
12V
3.3V
12V
RATED CURRENT
CURRENT RANGE
RATED POWER
3.5A
1A
0.5A
5A
3A
0.7A
0.5 ~ 3.85A
47.5W
0.1 ~ 1.1A
0.1 ~ 0.55A
0.5 ~ 5.5A
39.9W
43.9W
80mVp-p
+3,-2%
0.5%
0.3 ~ 3.3A
0.1 ~ 0.77A
PEAK LOAD(10sec.) Note.4 52.25W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 +3,-2%
OUTPUT
150mVp-p
6.0%
80mVp-p
8.0%
80mVp-p
8.0%
80mVp-p
+6,-10%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
2.0%
2.0%
1.0%
1.5%
3.0%
4.0%
1.5%
2.0%
+5.5,-5%
200ms, 15ms/230VAC
200ms, 15ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
70ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
79%
15ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
75%
INPUT
1.1A/115VAC
0.7A/230VAC
30A/115VAC
COLD START 60A/230VAC
For earth <200uA/264VAC, For patient <100uA/264VAC
115 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
ENVIRONMENT
SAFETY &
CH1: 5.75 ~ 6.75V
CH1: 3.8 ~ 4.45V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
EMC
(Note 5)
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
MTBF
677.8Khrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
101.6*50.8*29mm (L*W*H)
0.15Kg; 96pcs/15.4Kg/0.89CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:RPT-60-SPEC 2008-03-25
60W Triple Output Medical Type
RPT-60 series
Mechanical Specification
Unit:mm
101.6
95.25
3.175
3
2
1
2
3
4
5
6
CN1
1
CN2
4- 3.3
AC Input Connector (CN1) : JST B3P-VH or equivalent
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No. Assignment
Mating Housing
Terminal
Pin No. Assignment
Mating Housing
Terminal
1
2
3
AC/N
No Pin
AC/L
1,2
3,4
5
V1
COM
V2
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
6
V3
Block Diagram
fosc : 100KHz
RECTIFIERS
&
FILTER
V3
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
POWER
EMI
FILTER
+V1
I/P
FG
COM
SWITCHING
DETECTION
CIRCUIT
CONTROL
O.L.P.
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
90
100
80
80
60
70
60
40
50
40
20
(HORIZONTAL)
60 65 70
-20
0
10
20
30
40
50
90 95 100 115 120 140 160 180 200 220 240 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:RPT-60-SPEC 2008-03-25