RSDW20UW-12 [MEANWELL]

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter;
RSDW20UW-12
型号: RSDW20UW-12
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter

文件: 总7页 (文件大小:134K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
UL62368-1  
Applications  
Features  
Bus, tram, metro or railway system  
Telecom/datacom system  
Wireless network  
Compliance with railway standard EN50155  
DIP 2"x1" package with standard pinout  
18:1(8.5~160Vdc) ultra-wide input range  
Wide operating temperature range -40 ~ +95℃  
No minimum load required  
Industrial control facility  
Instrument  
Full encapsulated  
Analyzer  
Protections: Short circuit (Continuous) / Overload /  
Over voltage / Input under voltage  
3KVAC I/O isolation  
Highly vibrating, heavily dusty, exteremely  
low or hightemperature harsh environment  
Operating altitude up to 5000 meters (Note.5)  
Remote ON/OFF control  
3 years warranty  
Description  
RSDW20UW and RDDW20UW series are 20W module type DC-DC reliable railway converter with 2"x1"  
package. It features international standard pins, a high efficiency up to 89%, wide working temperature  
range -40~+95, 3KVAC I/P-O/P isolation voltage, meet EN50155 with external circuits, continuous-mode  
short circuit protection, etc. The models account for 8.5~160VDC 18:1 ultra-wide input range, and various  
output voltage, 5V/12V/15V for single output and ±12V/±15V/±24V for dual outputs, which are suitable for  
railway, trams, buses and also can be used in the harsh environment with high vibration, high dust,  
extremely low or high temperature, etc.  
Model Encoding  
R S DW20UW  
-12  
Output voltage (5/12/15Vdc±12/±15/±24Vdc)  
Ultra wide input voltage (8.5~160Vdc)  
Rated wattage  
S:Single output  
D:Dual output  
Series name  
{
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
MODEL SELECTION TABLE  
INPUT  
OUTPUT  
EFFICIENCY CAPACITOR LOAD  
OUTPUT  
ORDER NO.  
INPUT CURRENT  
INPUT VOLTAGE  
(RANGE)  
OUTPUT  
(Typ.)  
(MAX.)  
VOLTAGE  
CURRENT  
NO LOAD  
FULL LOAD  
RSDW20UW-05  
RSDW20UW-12  
RSDW20UW-15  
RDDW20UW-12  
RDDW20UW-15  
RDDW20UW-24  
5mA  
10mA  
8mA  
8mA  
9mA  
9mA  
323mA  
5V  
12V  
4000mA  
85.5%  
6800μF  
312mA  
312mA  
312mA  
312mA  
309mA  
1670mA  
1330mA  
89%  
89%  
88%  
89%  
89%  
3300μF  
2200μF  
*820μF  
*680μF  
15V  
Normal  
12V,24V,48V,72V,96V,110V  
(8.5 ~ 160V)  
± 12V  
± 15V  
± 24V  
± 0 ~833mA  
± 0 ~ 667mA  
± 0 ~ 417mA  
*330μF  
* For each output  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
SPECIFICATION  
VOLTAGE RANGE  
8.5 ~ 160Vdc  
SURGE VOLTAGE (100ms max.) 200Vdc  
INPUT  
FILTER  
Pi type  
PROTECTION  
VOLTAGE ACCURACY  
RATED POWER  
4A fast acting fuse  
± 1.0%  
20W  
RIPPLE & NOISE Note.2 100mVp-p  
LINE REGULATION Note.3 ± 0.2%  
OUTPUT  
LOAD REGULATION Note.4 Single output models: ± 0.3%, Dual output models:± 1%  
SWITCHING FREQUENCY (Typ.) 200KHz  
EXTERNAL TRIM ADJ. RANGE (Typ.) -20% ~ +15% (Single output model only)  
SHORT CIRCUIT  
OVERLOAD  
Protection type : Continuous, automatic recovery  
110 ~ 180% rated output power  
Protection type : Recovers automatically after fault condition is removed  
Protection type : Clamp by diode  
PROTECTION  
FUNCTION  
OVER VOLTAGE  
UNDER VOLTAGE LOCKOUT  
Start-up voltage  
9Vdc  
8Vdc  
Shutdown voltage  
Power ON: >4.0~160Vdc or open circuit  
Power OFF: <1.2Vdc or short  
REMOTE CONTROL  
Free-air convection  
COOLING  
-40 ~ +95(Refer to "Derating Curve")  
+105max. (+110thermal shutdown)  
20% ~ 90% RH non-condensing  
-55 ~ +125, 10 ~ 95% RH non-condensing  
0.03% / (0 ~ 95)  
WORKING TEMP.  
CASE TEMPERATURE  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
SOLDERING TEMPERATURE  
VIBRATION  
ENVIRONMENT  
1.5mm from case of 1 ~ 3sec./260max.  
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes  
5000 meters  
OPERATING ALTITUDE Note.5  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
ISOLATION CAPACITANCE (Typ.)  
UL62368-1, EAC TP TC 004 approved  
I/P-O/P:3KVAC  
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH  
20pF  
Parameter  
Conducted  
Radiated  
Standard  
Test Level / Note  
EN50121-3-2  
EN50121-3-2  
Standard  
Class A/B with external components  
N/A  
EMC EMISSION  
SAFETY &  
Parameter  
ESD  
Test Level / Note  
EMC  
( Note.6)  
EN61000-4-2  
EN61000-4-3  
Level 3, ± 8KV air, ± 6KV contact  
Level 3, 80~1000MHz, 20V/m  
Radiated Susceptibility  
Level 3, On power input port,± 2KV  
EFT/Burest  
EN61000-4-4  
EMC IMMUNITY  
external input capacitor required  
Level 4, Line to earth, ± 4KV  
Line to Line, ± 2KV  
Surge  
EN61000-4-5  
EN61000-4-6  
Conducted  
Level 3, 0.15~80MHz, 10V  
RAILWAY STANDARD  
MTBF  
EN50155 / IEC60571 including EN61373 for shock & vibration, EN50121-3-2 for EMC  
1570Khrs MIL-HDBK-217F(25)  
DIMENSION (L*W*H)  
CASE MATERIAL  
PACKING  
50.8*25.4*10.2mm (2*1*0.4 inch)  
Black coated copper with Non-Conductive Base  
28.5g  
OTHERS  
1.All parameters are specified at normal input(72Vdc), rated load, 2570% RH ambient.  
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.  
3.Line regulation is measured from low line to high line at rated load.  
4.Load regulation is measured from 0% to 100% rated load.  
NOTE  
5.The ambient temperature derating of 3.5/1000m for operating altitude higher than 2000m(6500ft).  
6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please  
refer to “EMI testing of component power supplies.”(as available onhttp://www.meanwell.com)  
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
External Output Trimming  
In order to trim the voltage up or down, one needs to connect the trim resistor either between the trim pin and -Vout for trim-up or between trim pin and  
+Vout for trim-down. The output voltage trim range is -20% to +15%. This is shown in Figures 1 and 2:  
+Vo  
+Vo  
+Vin  
-Vin  
+Vin  
R trim-down  
R-Load  
Trim  
R-Load  
R trim-up  
Trim  
-Vo  
-Vin  
-Vo  
Figure 1. Trim-up Voltage Setup  
Figure 2. Trim-down Voltage Setup  
Table 1 The typical value of Rtrim-up  
1. The RSDW20UW-05 value of Rtrim-up defined as:  
5V  
12V  
trim up (K  
317.46  
149.73  
93.82  
65.86  
49.09  
37.91  
29.92  
23.93  
19.27  
15.55  
12.50  
9.95  
15V  
R
trim up  
22.13 - 3.976 × ( V  
o
V
o
,
nom  
)
%
R
trim up  
=  
R
Ω)  
3.3 (KΩ)  
7.017 × ( V  
o
V  
o
,
nom  
)
1%  
2%  
59.21  
27.67  
17.16  
11.90  
8.75  
6.65  
5.14  
4.02  
3.14  
2.44  
1.87  
1.39  
0.99  
0.64  
0.34  
287.32  
134.66  
83.77  
58.33  
43.06  
32.89  
25.62  
20.17  
15.92  
12.53  
9.76  
2. The RSDW20UW-12 value of Rtrim-up defined as:  
3%  
120.76  
4%  
R
trim up  
=  
18 (KΩ)  
5%  
3 × ( Vo Vo, nom )  
6%  
3. The RSDW20UW-15 value of Rtrim-up defined as:  
7%  
8%  
104.42  
R
trim up  
=  
18 (KΩ)  
9%  
2.28 × ( Vo Vo, nom )  
10%  
11%  
12%  
13%  
14%  
15%  
Where  
R
V
V
trim-up is the external resistor in Kohm.  
7.44  
7.80  
5.49  
o
,
nom is the nominal output voltage.  
5.96  
3.81  
o
is the desired output voltage.  
4.36  
2.35  
Trim up Resistor Values are internal to the unit and are defined in Table 1.  
For example, to trim-up the output voltage of 5V module (RSDW20UW-05) by 5% to 5.25V, R trim-up is calculated as follows:  
22.13 - 3.976 × ( 5.25 5 )  
R
trim up  
=  
3.3 = 8.75 (KΩ)  
7.017 × ( 5.25 5 )  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
Table 2 The typical value of Rtrim-down  
4. The RSDW20UW-05 value of Rtrim-down defined as:  
5V  
12V  
trim down (K  
545.46  
259.19  
163.77  
116.06  
87.43  
68.34  
54.71  
44.49  
36.54  
30.17  
24.97  
20.63  
16.96  
13.82  
11.09  
8.70  
15V  
R
trim down  
42 - 16.803 × (V  
o
,
nom  
Vo)  
%
R
trim down  
=  
R
Ω)  
3.3 (KΩ)  
7.017 × (Vo, nom Vo)  
1%  
2%  
114.03  
54.17  
34.21  
24.24  
18.25  
14.26  
11.41  
9.27  
575.60  
274.26  
173.81  
123.59  
93.46  
73.37  
59.02  
48.25  
39.88  
33.19  
27.71  
23.14  
19.28  
15.97  
13.10  
10.59  
8.37  
5. The RSDW20UW-12 value of Rtrim-down defined as:  
3%  
206.116  
4%  
R
trim down  
=  
27.08 (K  
Ω
)
5%  
3 × (Vo, nom Vo)  
6%  
6. The RSDW20UW-15 value of Rtrim-down defined as:  
7%  
8%  
206.116  
R
trim down  
=  
27.08 (K  
Ω
)
9%  
7.61  
2.28 × (Vo, nom Vo)  
10%  
11%  
12%  
13%  
14%  
15%  
16%  
17%  
18%  
19%  
20%  
6.28  
Where  
5.19  
4.28  
R
V
V
trim-down is the external resistor in Kohm.  
3.52  
o
,
nom is the nominal output voltage.  
2.86  
o
is the desired output voltage.  
2.29  
Trim down Resistor Values are internal to the unit and are defined in Table 2.  
1.79  
For example, to trim-down the output voltage of 12V module (RSDW20UW-12)  
by 5% to 11.4V, R trim-down is calculated as follows:  
1.35  
6.60  
0.96  
4.73  
6.40  
206.116  
0.61  
3.05  
4.64  
R
trim down  
=  
27.08 = 87.43(KΩ)  
3 × (12 11.4 )  
0.29  
1.55  
3.05  
The RSDW20UW-05 models is adjustable within the range of -20% to +15%.  
For RSDW20UW-12 and RSDW20UW-15 models, see input & output trim curves for trim up and trim down ranges.  
RSDW20UW-12  
RSDW20UW-15  
13.8  
12.0  
17.3  
15.0  
Upper Trim Limit  
Upper Trim Limit  
9.6  
12.0  
Lower Trim Limit  
Lower Trim Limit  
8.5  
10  
160  
8.5  
10  
160  
INPUT VOLTAGE (V)  
INPUT VOLTAGE (V)  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
Mechanical Specification  
Plug Assignment  
All dimensions in mm(inch)  
Tolerance:x.x± 0.5mm(x.xx± 0.02")  
x.xx± 0.25mm(x.xxx± 0.010")  
Pin size is:0.5± 0.05mm (0.02±± 0.002")  
Pin-Out  
RSDW20UW RDDW20UW  
(Single output) (Dual output)  
Pin No.  
25.4(1)  
1
2
3
4
5
6
+Vin  
-Vin  
+Vin  
-Vin  
10.16(0.4) 10.16(0.4)  
2.5(0.1)  
+Vout  
Trim  
-Vout  
+Vout  
-Vout  
5
4
3
Common  
Remote ON/OFF Remote ON/OFF  
Side View  
Bottom View  
1
2
6
10.2(0.4)  
5.08(0.2)  
15.24(0.6)  
5.1(0.2)  
5.6(0.22 min.)  
Derating Curve  
5V  
100  
80  
other  
60  
Natural convection  
40  
20  
-40  
-20  
0
20  
40  
60 67 77  
85 95 105  
Ta ()  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  
20W 2"x1" 8.5~160Vdc Ultra-wide Input Railway DC-DC Converter  
RSDW20UW & RDDW20UW series  
Output derating VS Input voltage  
100  
80  
70  
60  
40  
20  
8.5  
12  
24  
48  
72  
96  
110  
160  
INPUT VOLTAGE  
EMC Suggestion Circuit  
EMI Test standard: EN55032 Conducted & Radiated Emission, EN50121-3-2:2016 Output Conducted Emission  
Test Condition: Input Voltage: 110Vdc, Output Load: Full Load  
CY4  
L2  
L1  
+Vin  
-Vin  
+Vout  
RSDW20UW  
-Vout  
+Vin  
-Vin  
CY2  
CY3  
C1  
C2  
C3  
C4  
R Load  
CY1  
CY5  
EN55032 Class B  
CY2, CY3  
Model No.  
C1,C2,C3  
C4  
CY1  
CY4, CY5  
L1  
L2  
RSDW20UW-05  
RSDW20UW-12  
RSDW20UW-15  
RDDW20UW-15  
RDDW20UW-15  
RDDW20UW-15  
680pF  
400VAC  
Y1 capacitor  
1uF/250V  
1812  
Ceramic  
capacitor  
120uF/220V  
KXJ Series  
Aluminum  
capacitor  
1.4mH  
ψ0.4mmx1/13T  
ACME A151  
T10x5x5C  
500pF  
400VAC  
Y1 capacitor  
2200pF  
400VAC  
Y1 capacitor  
10μH/7A  
2525CZ  
Vishay  
470pF  
400VAC  
Y1 capacitor  
Note: C1, C2, C3: 1812 X7R ceramic capacitor.  
C4: NIPPON CHEMI-CON KXJ series aluminum capacitor or equivalent.  
CY1, CY2, CY3, CY4, CY5: TDK Y1 capacitor or equivalent.  
L1: 1.4mH ψ0.4mmx1/13T ACME A151 T10x5x5C (G91C9925115).  
L2: 10μH/7A 2525CZ VISHAY (G91B0904007).  
Installation Manual  
Please refer to : http://www.meanwell.com/manual.html  
File Name:RSDW20UW,RDDW20UW-SPEC 2020-10-30  

相关型号:

RSDW20UW-15

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL

RSE-0505H2

2:1 Wide Input Range
RECOM

RSE-0505S

2:1 Wide Input Range
RECOM

RSE-1.5

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-1.5-E

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-1.5-S

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-12

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-12-E

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-12-S

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-1A-1.5-S

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-1A-12-S

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI

RSE-1A-3-S

Ultra small size, High sensitive (50mW,150mW), Single pole relay
SHINMEI