SLD-50-12 [MEANWELL]
50W linear LED Driver;型号: | SLD-50-12 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 50W linear LED Driver |
文件: | 总6页 (文件大小:526K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
50W linear LED Driver
SLD-50 series
■
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧/Ⅱ
‧
‧
‧
■
~
℃℃
■
File Name:SLD-50-SPEC 2019-11-13
50W Constant Voltage+Constant Current LED Driver
SLD-50 series
SPECIFICATION
MODEL
SLD-50-12
SLD-50-24
12V
24V
DC VOLTAGE
8.4 ~12V
4.2A
16.8 ~24V
2.1A
CONSTANT CURRENT REGION Note.2
RATED CURRENT
50.4W
Note.5
50.4W
240mVp-p
±3.0%
±0.5%
±0.5%
RATED POWER
150mVp-p
±4.0%
±0.5%
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE Note.4
LINE REGULATION
OUTPUT
±1.5%
LOAD REGULATION
500ms, 80ms 115VAC / 230VAC
SETUP, RISE TIME Note.6
10ms/230VAC
110 ~ 305VAC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
10ms/115VAC
155 ~ 431VDC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
Note.5
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 10%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
TOTAL HARMONIC DISTORTION
INPUT
EFFICIENCY (Typ.)
AC CURRENT
88%
0.6A / 115VAC
90%
0.3A / 230VAC
0.25A/277VAC
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
COLD START 50A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
8 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
<0.25mA / 277VAC
LEAKAGE CURRENT
NO LOAD POWER CONSUMPTION <0.5W
95 ~ 108%
Constant current limiting or Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
PROTECTION
ENVIRONMENT
14 ~ 17V
28 ~ 34V
Shut down and latch off o/p voltage, re-power on to recover
Shut down output voltage, re-power on to recover
Tcase=-20 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Tcase=+90℃
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃(0 ~ 50℃)
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”),CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384,
EAC TP TC 004, GB19510.1,GB19510.14
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Standard
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EN61000-3-2,GB/T17625.1
EN61000-3-3
Test Level / Note
-----
-----
Class C @load≥60%
-----
EMC EMISSION
EMC IMMUNITY
SAFETY &
EMC
Standard
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2
Level 2
1KV/Line-Line
Level 2
Level 2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
>95% dip 0.5 periods, 30% dip 25 periods,
Voltage Dips and Interruptions
EN61000-4-11
>95% interruptions 250 periods
MTBF
DIMENSION
PACKING
1304.51K hrs min. Telcordia SR-332 (Bellcore) ; 362.82K hrs min. MIL-HDBK-217F (25℃)
280*30*16.8mm (L*W*H)
0.175Kg;64pcs/12.4Kg/ 0.67CUFT
OTHERS
NOTE
℃
℃
℃℃
File Name:SLD-50-SPEC 2019-11-13
50W Constant Power Mode LED Driver
SLD-50 series
SPECIFICATION
MODEL
SLD-50-56
RATED CURRENT
RATED POWER
1050mA
Note.2 50.4W
CONSTANT CURRENT REGION Note.3 30 ~56V
FULL POWER CURRENT RANGE 900~1400mA
OPEN CIRCUIT VOLTAGE (max.) 60V
OUTPUT
CURRENT ADJ. RANGE
CURRENT RIPPLE
CURRENT TOLERANCE
450-1400mA
5.0%(@rated current)
±5%
SET UP TIME
Note.5
500ms/230VAC, 1200ms/115VAC
110 ~ 305VAC
155VDC ~ 431VDC
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
Note.2
(Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section)
47 ~ 63Hz
PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load
(Please refer to "Power Factor Characteristic" section)
THD< 10% (@ load≧60% at 115VAC/230VAC ,@load≧75% at 277VAC)
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)
90%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
0.6A / 115VAC
0.3A / 230VAC
0.25A / 277VAC
COLD START 50A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
8 unit(circuit breaker of type B) / 16 units(circuit breaker of type C) at 230VAC
<0.25mA / 277VAC
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
NO LOAD POWER CONSUMPTION <0.5W
110 ~ 150%
OVER POWER
Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
61 ~ 80V
Shut down output voltage, re-power on to recovery
Shut down output voltage, re-power on to recovery
Tcase=-20 ~ +90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
Tcase=+90℃
20 ~ 95% RH non-condensing
-40 ~ +80℃
±0.03%/℃(0 ~ 60℃)
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
ENVIRONMENT
OVER TEMPERATURE
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”),CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384,
EAC TP TC 004, GB19510.1,GB19510.14
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Standard
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EN61000-3-2,GB/T17625.1
EN61000-3-3
Test Level / Note
-----
-----
Class C @load≥60%
-----
EMC EMISSION
EMC IMMUNITY
SAFETY &
EMC
Standard
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2
Level 2
1KV/Line-Line
Level 2
Level 2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
>95% dip 0.5 periods, 30% dip 25 periods,
Voltage Dips and Interruptions
EN61000-4-11
>95% interruptions 250 periods
MTBF
DIMENSION
PACKING
1304.51K hrs min. Telcordia SR-332 (Bellcore) ; 362.82K hrs min. MIL-HDBK-217F (25℃)
280*30*16.8mm (L*W*H)
0.175Kg;64pcs/12.4Kg/ 0.67CUFT
OTHERS
NOTE
℃
℃
℃℃
File Name:SLD-50-SPEC 2019-11-13
50W linear LED Driver
SLD-50 series
BLOCK DIAGRAM
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
Vo+
Vo-
I/P
CIRCUIT
O.L.P.
DETECTION
CIRCUIT
O.T.P.
O.L.P.
PWM & PFC
CONTROL
O.V.P.
DRIVING METHODS OF LED MODULE
◎ SLD-50-12,24
※ This series is able to work in either Constant Current mode (a direct drive way) or
Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
100
Should there be any compatibility issues, please contact MEAN WELL.
(B)
Constant
Current area
(A)
Constant
Voltage area
70
(min.)
(C)
Hiccup
Protection
100
50
Io(%)
Typical output current normalized by rated current (%)
◎ SLD-50-56
60V
55V
50V
45V
40V
35V
30V
25V
450mA,56V
900mA,56V
1400mA, 36V
1400mA,30V
900mA,30V
0mA
300mA
600mA
900mA
1200mA
1500mA
Recommend Performance Region
File Name:SLD-50-SPEC 2019-11-13
50W linear LED Driver
SLD-50 series
OUTPUT LOAD vs TEMPERATURE
100
80
100
230VAC
80
60
40
60
110VAC
50
40
20
20
-20
-15
0
15
30
50
60
90
(HORIZONTAL)
(HORIZONTAL)
-20
-10
0
15
30 40 50
60 65 70
AMBIENT TEMPERATURE,Ta (℃)
Tcase (℃)
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
※ Tcase at 75℃
Constant Current Mode
100
90
80
70
60
50
40
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
277V
230V
115V
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
100 110 125 135 145 155 165 175 180 200 230 305
INPUT VOLTAGE (V) 60Hz
LOAD
※De-rating is needed under low input voltage.
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
SLD-50 series possess superior working efficiency that up to 90% can
be reached in field applications.
※ 24V Model, Tcase at 75℃
※ 24V Model, Tcase at 75℃
14
12
10
96%
94%
92%
90%
88%
86%
84%
82%
80%
78%
277V
8
277V
230V
230V
115V
6
115V
4
2
0
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
50%
60%
70%
80%
90%
100%
LOAD
LOAD
File Name:SLD-50-SPEC 2019-11-13
50W linear LED Driver
SLD-50 series
LIFE TIME
120
100
80
60
40
20
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90
Tcase (℃)
Mechanical Specification
Unit:mm
56V with Io adjustable
TB1
TB2
280
272
4
T case
113.6
2-φ3.5
※ T case: Max. Case Temperature.
TB1 wiring:
9-10mm
TB2 wiring:
9-10mm
0.75-1.50mm2
0.75-1.50mm2
Terminal Pin No. Assignment (TB1) :
DEGSON DG219-3.5(GRAY)
Pin No. Assignment
Terminal Pin No. Assignment (TB2) :
DEGSON DG219-3.5(RED/BLACK)
Pin No. Assignment
1
2
AC/L
AC/N
1
2
+V
-V
INSTALLATION MANUAL
Please refer to:http://www.meanwell.com/manual.html
File Name:SLD-50-SPEC 2019-11-13
相关型号:
©2020 ICPDF网 联系我们和版权申明