TN-1500_12 [MEANWELL]

1500W True Sine Wave DC-AC Inverter with Solar Charger; 1500W纯正弦波直流 - 交流逆变器与太阳能充电器
TN-1500_12
型号: TN-1500_12
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

1500W True Sine Wave DC-AC Inverter with Solar Charger
1500W纯正弦波直流 - 交流逆变器与太阳能充电器

文件: 总4页 (文件大小:482K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1500W True Sine Wave DC-AC Inverter with Solar Charger  
TN-1500 series  
Features :  
True sine wave output (THD<3%)  
High surge power up to 3000W  
U.P.S. mode and energy saving mode (selectable)  
High efficiency up to 91%  
Power ON-OFF switch  
Standby saving mode can be selectable  
Front panel indicator for operation status  
Thermostatically controlled cooling fan  
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.  
/ Output short / Input polarity reverse / Overload / AC circuit breaker  
Application : Home appliance, power tools, office and portable  
equipment, vehicle and yacht ...etc.  
Built-in solar / AC charger  
Optional monitoring software  
3 years warranty  
E13  
SPECIFICATION  
MODEL  
TN-1500-112  
TN-1500-124  
TN-1500-148  
TN-1500-212  
TN-1500-224  
TN-1500-248  
RATED POWER (Typ.)  
1500W  
MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles  
Factory setting set at 110VAC  
Factory setting set at 230VAC  
AC VOLTAGE  
100 / 110 / 115 / 120VAC selectable by setting button S.W  
60 0.1Hz 50/60Hz selectable by setting button S.W  
Note.2 True sine wave (THD<3%) at rated input voltage  
3.0%  
200 / 220 / 230 / 240VAC selectable by setting button S.W  
50 0.1%Hz 50/60Hz selectable by setting button S.W  
FREQUENCY  
OUTPUT  
WAVEFORM  
AC REGULATION (Typ.)  
TRANSFER TIME (Typ.)  
SAVING MODE (Typ.)  
FRONT PANEL INDICATOR  
BAT. VOLTAGE  
10ms inverter  
Default disabled. Load 5W will be changed to standby mode  
Battery voltage level, output load level, saving mode, fault and operation status  
by pass  
24V  
48V  
24V  
48V  
12V  
12V  
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC  
21 ~ 30VDC  
75A  
42 ~ 60VDC  
37.5A  
10.5 ~ 15VDC  
150A  
21 ~ 30VDC  
75A  
42 ~ 60VDC  
37.5A  
DC CURRENT (Typ.)  
Note.5 150A  
18W @ standby saving mode  
INPUT  
NO LOAD DISSIPATION  
OFF MODE CURRENT DRAW  
1mA  
EFFICIENCY (Typ.)  
BATTERY TYPES  
FUSE  
Note.2 87%  
89%  
89%  
88%  
90%  
91%  
Open & sealed Lead Acid  
40A*5  
30A*3  
30A*2  
45 4%  
42 4%  
40A*5  
30A*3  
30A*2  
45 4%  
42 4%  
BATTERY  
INPUT  
PROTECTION  
11.3 4%  
22.5 4%  
21 4%  
11.3 4%  
10.5 4%  
22.5 4%  
21 4%  
BAT. LOW ALARM  
BAT. LOW SHUTDOWN  
REVERSE POLARITY  
10.5 4%  
By internal fuse open  
82  
5
82  
5
96  
5
68  
5
68  
5
68  
5
OVER TEMPERATURE  
OUTPUT SHORT  
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor  
Protection type : Shut down o/p voltage, re-power on to recover  
OUTPUT  
PROTECTION  
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.  
OVER LOAD (Typ.)  
Protection type : Shut down o/p voltage, re-power on to recover  
CIRCUIT BREAKER  
GFCI PROCTECTION  
WORKING TEMP.  
20A  
10A  
Optional (Only type F)  
None  
0 ~ +40 @ 100% load ; 60 @ 50% load  
Note.3  
20% ~ 90% RH non-condensing  
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH  
WORKING HUMIDITY  
ENVIRONMENT  
STORAGE TEMP., HUMIDITY  
VIBRATION  
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes  
None  
UL458 (only for "GFCI" receptacle-Type F )  
None  
SAFETY STANDARDS  
LVD  
EN60950-1  
SAFETY &  
EMC  
Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC  
WITHSTAND VOLTAGE  
EMC EMISSION  
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark  
Compliance to FCC class A  
None  
Compliance to EN61000-4-2,3,4,5,6,8,11  
EMC IMMUNITY  
2.7A  
1.35A  
57V 4%  
75V  
2.7A  
5.5A  
1.35A  
57V 4%  
75V  
CHARGE CURRENT (Typ.)  
5.5A  
AC  
CHARGER CHARGE VOLTAGE  
28.5V 4%  
45V  
28.5V 4%  
14.3V 4%  
14.3V 4%  
45V  
25V  
MAX OPEN CIRCUIT VOLTAGE 25V  
SOLAR  
CHARGER  
CHARGE CURRENT (max.)  
CHARGE VOLTAGE  
CONTROL WIRING  
DIMENSION  
30A  
28.5V 4%  
57V 4%  
28.5V 4%  
14.3V 4%  
57V 4%  
14.3V 4%  
RJ11 -RS232 (Option)  
OTHERS  
NOTE  
420*220*88mm (L*W*H)  
6.85Kg; 2pcs/14.7Kg/1.61CUFT  
PACKING  
1.Output derating capacity referenced by curve 1.  
2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.  
3.Output derating capacity referenced by curve 2.  
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.  
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.  
File Name:TN-1500-SPEC 2012-02-21  
1500W True Sine Wave DC-AC Inverter with Solar Charger  
TN-1500 series  
Instructions for TN-1500 monitoring software  
1. Installation of TN-1500 unit and PC  
5
9
4
8
3
7
2
6
1
1
6
Phone Jack  
RJ11  
DB9 FEMALE  
RJ11  
PIN NO.  
DB9  
2
3
3
5
4
2
PIN NO.  
Figure 1  
2. Explanation of Monitoring Manu  
2.1 Main Page  
Inverter TN V.1.1  
Setting  
Statistics  
R.C. Power off  
Pause  
Exit  
1
2
3
4
Solar Charge  
INVERTER  
100  
0
100  
0
AC Charge  
5
Battery  
Loading  
O/P Voltage 110  
V
Battery Voltage 54.1 V  
O/P Frequency 60.0 Hz  
Internal Temperature 10.0  
TN-1500-143  
AC In  
By pass  
Utility Voltage 0.0  
V
Power on  
Remote off  
Battery low  
6
Start Date 2007/12/07 03:13:33 PM  
Reset Date 2007/12/21 01:40:56 PM  
Battery used up  
Stand by saving mode  
Abnormal Shutdown  
Figure 2  
1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details.  
2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details.  
3. R.C. Power off: Power can be turned ON or OFF at the remote location.  
4. Pause: Stop refreshing the page of monitoring software.  
5. Status of unit: Indicating current operating status of TN-1500.  
6. Signals that display current condition of the unit.  
File Name:TN-1500-SPEC 2012-02-21  
1500W True Sine Wave DC-AC Inverter with Solar Charger  
TN-1500 series  
2.2 Setting Page  
Inverter Setting  
File Name D:\TN_110RR\20071205\REV\TN_110RR\TNF\TN_1K5_512.TNF  
Model name TN-1500-212  
Manufacture MeanWell  
Revision REV:1.10  
Series Number LOC-1234567890  
Date Of Manu. 06/23/2007  
I/O Type 212  
Voltage 230  
Equalization Volt.  
Floating Volt.  
Alarm Volt.  
14.3  
13.3  
11.3  
10.5  
V
V
V
V
13.5 ~ 15.0V  
13.0 ~ 13.5V  
11.0 ~ 11.5V  
10.0 ~ 11.0V  
V
1
Frequency 50  
Hz  
Stand-by saving mode  
UPS mode  
Shutdown Volt.  
On  
On  
On  
Off  
Energy saving mode  
Bauds Rate 9600  
1
Comm Ports  
Read Write  
Lead  
4
Exit  
Read OK!!  
2
3
Figure 3  
1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage,  
and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page.  
2. Read: Read current settings of the unit.  
3. Write: Write the revised setting into the unit.  
4. Load: Load in factory default settings.  
2.3 Statistic Page  
Inverter Setting  
Start Date 2007/12/07 03:13:33 PM  
Start Date 2007/12/21 01:40:56 PM  
Inverter time rate  
Bypass time rate  
Shut Down rate  
Solar time rate  
91.2  
0.0  
%
%
%
%
%
Inverter time rate  
Bypass time rate  
Shut Down rate  
Solar time rate  
31.9  
0.0  
%
%
%
%
%
8.8  
68.1  
0.0  
0.0  
Loading average  
24.7  
Loading average  
63.7  
RESET  
Exit  
Figure 4  
1. Start Date: Date that installing the monitoring software.  
2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit.  
3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period.  
4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole  
operating period.  
5. Shut down rate: Percentage of time period that the unit is under the condition of shut down.  
* Inverter time rate + Bypass time rate + Shut down rate = 100%  
6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-1500 unit.  
7. Loading average: Average loading after turning on the TN-1500 unit.  
File Name:TN-1500-SPEC 2012-02-21  
1500W True Sine Wave DC-AC Inverter with Solar Charger  
TN-1500 series  
TN 1500 112 A  
A :TYPE A OUTLET  
B :TYPE B OUTLET  
C :TYPE C OUTLET  
D :TYPE D OUTLET  
E :TYPE E OUTLET  
F :TYPE F OUTLET  
True sine wave inverter  
+AC charger and solar charger  
12:12VDC  
Bat. Voltage: 24:24VDC  
48:48VDC  
1:110VAC  
Output:  
O/P Wattage:1500W  
2:230VAC  
AC Output Receptacles (optional)  
Receptacle type  
TYPE-A  
TYPE-B  
TYPE-C  
AUSTRALIA  
TYPE-D  
TYPE-E  
JAPAN  
TYPE-F  
GFCI  
Country  
USA  
EUROPE  
U.K  
E13  
E13  
E13  
Certificate  
(Expect for 48V input)  
Mechanical Specification  
Derating Curve  
Unit:mm  
57.75  
36.25  
100  
80  
15.6  
22  
1xx  
2xx  
60  
40  
)
b
n
)
l 5 . i 6 2 - 7 . 7 1 e u ( q r o T  
s e r i d e W r e d l C S  
T U P N I  
C D  
o
u
r t  
G
2 1 2 - S H  
W S A 4 - 0 1 ( e g n a e r i R W  
G G 1 ( .  
)
1
o N . t a C  
d n u o r  
G
s i s s a h C  
. t i n U  
l l i D  
e s P r e v e R  
e h T e g a  
y t i r a l  
m
a
W
S O P  
G E N  
o
20  
) x a m A 0 3 (  
t u p n r a I l o S  
T U P N C A I  
47  
0
10  
20  
30  
40  
50  
60  
70  
AMBIENT TEMPERATURE (  
CURVE 1  
)
-
-
-
+
+
+
Air flow  
direction  
100  
80  
60  
40  
20  
10  
10.5VDC  
21VDC  
42VDC  
11.5VDC  
23VDC  
46VDC  
15VDC (HORIZONTAL)  
30VDC  
60VDC  
BATTERY INPUT VOLTAGE (V)  
CURVE 2  
AC OUTPUT  
SOLAR CHARGE  
ON  
AC CHARGE  
Setting  
On  
BATTERY  
INVERTER  
LOAD  
100  
100  
OFF  
0
i
B
Bat Low  
Saving  
r
0
u
r c  
a
k
e
C
AC IN  
BY PASS  
t
e
s
e
R
t
Remote  
port  
Type-A  
AC OUTPUT  
SOLAR CHARGE  
ON  
AC CHARGE  
100  
Setting  
On  
BATTERY  
INVERTER  
LOAD  
100  
OFF  
0
i
B
Bat Low  
Saving  
r
0
u
r c  
a
k
e
C
AC IN  
BY PASS  
t
e
s
e
R
t
Remote  
port  
Type-B  
207  
220  
File Name:TN-1500-SPEC 2012-02-21  

相关型号:

TN-162

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-163

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-164

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-165

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-165051-25-9

Label format - Old format order code cross reference
MACOM

TN-165102-10-9

Label format - Old format order code cross reference
MACOM

TN-166A

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-167

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-170

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-171

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE

TN-171171-10-9

Label format - Old format order code cross reference
MACOM

TN-172

MICROWAVE NOISE TUBES & NOISE SOURCES
CLARE