TS-1500-224F [MEANWELL]

1500W True Sine Wave DC-AC Power Inverter; 1500W纯正弦波直流 - 交流逆变器
TS-1500-224F
型号: TS-1500-224F
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

1500W True Sine Wave DC-AC Power Inverter
1500W纯正弦波直流 - 交流逆变器

文件: 总2页 (文件大小:306K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1500W True Sine Wave DC-AC Power Inverter  
TS-1500 series  
Features :  
True sine wave output (THD<3%)  
High surge power up to 3000W  
High efficiency up to 91%  
Power ON-OFF switch  
Standby saving mode can be selectable  
Front panel indicator for operation status  
Thermostatically controlled cooling fan  
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.  
/ Output short / Input polarity reverse / Overload  
Application : Home appliance, power tools, office and portable  
equipment, vehicle and yacht ...etc.  
Optional monitoring software  
13  
E
2 years warranty  
SPECIFICATION  
MODEL  
TS-1500-112  
TS-1500-124  
TS-1500-148  
TS-1500-212  
TS-1500-224  
TS-1500-248  
RATED POWER (Typ.)  
1500W  
MAXIMUM OUTPUT POWER 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles  
AC VOLTAGE  
100 / 110 / 115 / 120VAC selectable by setting button  
60 0.1Hz 50/60Hz selectable by setting button S.W  
True sine wave (THD<3%) at rated input voltage  
3.0%  
200 / 220 / 230 / 240VAC selectable by setting button  
50 0.1%Hz 50/60Hz selectable by setting button S.W  
FREQUENCY  
OUTPUT  
WAVEFORM  
AC REGULATION (Typ.)  
SAVING MODE (Typ.)  
FRONT PANEL INDICATOR  
BAT. VOLTAGE  
Load 5W will be changed to standby mode  
Battery voltage level, output load level, saving mode, fault and operation status  
24V  
48V  
24V  
48V  
12V  
12V  
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC  
21 ~ 30VDC  
75A  
42 ~ 60VDC  
37.5A  
10.5 ~ 15VDC  
150A  
21 ~ 30VDC  
75A  
42 ~ 60VDC  
37.5A  
DC CURRENT (Typ.)  
Note.5 150A  
18W @ standby saving mode  
INPUT  
NO LOAD DISSIPATION  
OFF MODE CURRENT DRAW  
1mA  
EFFICIENCY (Typ.)  
BATTERY TYPES  
FUSE  
Note.2 87%  
89%  
90%  
88%  
90%  
91%  
Open & sealed Lead Acid  
40A*5  
30A*3  
30A*2  
45 4%  
42 4%  
40A*5  
30A*3  
30A*2  
45 4%  
42 4%  
BATTERY  
INPUT  
PROTECTION  
11.3 4%  
22.5 4%  
21 4%  
11.3 4%  
10.5 4%  
22.5 4%  
21 4%  
BAT. LOW ALARM  
BAT. LOW SHUTDOWN  
REVERSE POLARITY  
10.5 4%  
By internal fuse open  
82  
5
82  
5
96  
5
68  
5
68  
5
68  
5
OVER TEMPERATURE  
OUTPUT SHORT  
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor  
Protection type : Shut down o/p voltage, re-power on to recover  
OUTPUT  
PROTECTION  
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.  
OVER LOAD (Typ.)  
Protection type : Shut down o/p voltage, re-power on to recover  
GFCI PROCTECTION  
WORKING TEMP.  
Optional (Only type F)  
None  
0 ~ +40 @ 100% load ; 60 @ 50% load  
20% ~ 90% RH non-condensing  
Note.3  
WORKING HUMIDITY  
ENVIRONMENT  
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH  
STORAGE TEMP., HUMIDITY  
VIBRATION  
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes  
EN60950-1  
SAFETY STANDARDS  
UL458 (only for type F)  
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC  
SAFETY & WITHSTAND VOLTAGE  
EMC  
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark  
Compliance to EN61000-4-2,3,8 ENV50204  
EMI CONDUCTION&RADIATION Compliance to FCC class A  
-----  
EMS IMMUNITY  
CONTROL WIRING  
DIMENSION  
RJ11 -RS232 (Option)  
OTHERS  
NOTE  
420*220*88mm (L*W*H)  
6.81Kg; 2pcs/14.6Kg/1.61CUFT  
PACKING  
1.Output derating capacity referenced by curve 1.  
2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.  
3.Output derating capacity referenced by curve 2.  
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.  
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.  
File Name:TS-1500-SPEC 2008-07-29  
1500W True Sine Wave DC-AC Power Inverter  
TS-1500 series  
TS 1500 112 A  
A :TYPE A OUTLET  
B :TYPE B OUTLET  
C :TYPE C OUTLET  
D :TYPE D OUTLET  
E :TYPE E OUTLET  
F :TYPE F OUTLET  
12:12VDC  
Bat. Voltage: 24:24VDC  
48:48VDC  
TS:True sine wave inverter  
1:110VAC  
Output:  
O/P Wattage:1500W  
2:230VAC  
AC Output Receptacles (optional)  
TYPE-A  
USA  
TYPE-B  
TYPE-C  
TYPE-D  
TYPE-E  
JAPAN  
TYPE-F  
GFCI  
EUROPE  
AUSTRALIA  
U.K  
Mechanical Specification  
Unit:mm  
57.75  
36.25  
15.6  
Air flow  
direction  
)
b
n
)
l 5 . i 6 2  
s e r i  
-
7 . 7 1 e u ( q  
d e W r e d l  
e g n a  
G G ( .  
r
o T  
C S  
r i R W  
. t  
o
u
r t  
G
2 1 2  
W S A 4 -  
S H  
0 1  
(
e
)
-
1
1
o
N
a
C
d n u o r  
G
C
r
e t r e v n I  
e t r e v n I  
r
r
e t r e v n I  
e t r e v n I  
s i s s a h  
r
S O P  
T U P N I  
C D  
G N E  
:
G N I N R A W  
e h T e g a  
y t i r a l  
m
a
l l i D  
e s P r e v e  
W
R
o
10  
AC OUTPUT  
ON  
BATTERY  
100  
Setting  
LOAD  
100  
OFF  
INVERTER  
On  
0
0
Bat Low  
Saving  
Remote  
port  
Type-A  
AC OUTPUT  
ON  
BATTERY  
100  
Setting  
On  
LOAD  
100  
OFF  
INVERTER  
0
0
Bat Low  
Saving  
Remote  
port  
207  
220  
Type-B  
File Name:TS-1500-SPEC 2008-07-29  

相关型号:

TS-1500-248

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248A

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248B

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248C

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248D

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248E

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500-248F

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500_11

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-1500_12

1500W True Sine Wave DC-AC Power Inverter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

TS-15A

Normally Open, Close on tempertature rise

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
PANASONIC

TS-16

TEMPERATURE CONTROL DIN RAIL

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BUD

TS-1AMB

THERMOPILE INFRARED SENSOR

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC