UHP-1000-24 [MEANWELL]
1000W Slim Type with PFC Switching Supply;型号: | UHP-1000-24 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 1000W Slim Type with PFC Switching Supply 功率因数校正 |
文件: | 总8页 (文件大小:333K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1000W Slim Type with PFC Switching Supply
UHP-1000 series
Bauart gepruft
Sicherheit
egelma ge
o s
od
be wac
g
www.tuv.com
ID 2000000000
EN62368-1
UL62368-1
IEC62368-1
■ Features
ꢀSlim and Low profile (41mm)
■ Certificates
ꢀSafety: UL/EN62368-1
ꢀEMC: EN 55032 / 55024
ꢀFanless and conduction-cooled design
ꢀWithstand 300VAC surge input for 5 seconds
ꢀBuilt-in active PFC function
■ Applications
ꢀ-30~+70℃ working temperature
ꢀOutput voltage and constant current level programmable
ꢀProtections: Short circuit / Overload / Over voltage /
Over temperature
ꢀIndustrial automation machinery
ꢀIndustrial control system
ꢀMechanical and electrical equipment
ꢀElectronic instruments, equipment
or apparatus
ꢀBuilt-in remote ON-OFF control
ꢀDC OK active signal
ꢀTest and measurement instrument
ꢀLaser rlated machine
ꢀOperating altitude up to 5000 meter (Note.5)
ꢀLED indicator for power on
ꢀCharging related equipment
ꢀHousehold appliances
ꢀ3 years warranty
■ Description
UHP-1000 series is a 1000W single-output slim type power supply with 41mm of low profile design.
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 12V,24V,36V
and 48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ 70℃ under
air convection without fan. UHP-1000 has the complete protection functions and 5G anti-vibration
capability; It is complied with the international safety regulations such as TUV EN62368-1, UL62368-1,
and the design refers to EN61558-1 and EN60335-1. UHP-1000 series serves as a high performance
power supply solution for various industrial applications.
■ Model Encoding
UHP - 1000 - 12
Output voltage(12V/24V/36V/48V)
Rated wattage
Series name
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
SPECIFICATION
MODEL
UHP-1000-12
UHP-1000-24
UHP-1000-36
UHP-1000-48
36V
48V
DC VOLTAGE
12V
24V
RATED CURRENT
80A
42A
28A
21A
RATED POWER(convection)
RIPPLE & NOISE (max.) Note.2
960W
1008W
240mVp-p
1008W
240mVp-p
1008W
300mVp-p
150mVp-p
By built-in potentiometer, SVR
VOLTAGE ADJ. RANGE
OUTPUT
24~28.8V
36~43.2V
1.0%
48~57.6V
1.0%
12~14.4V
1.0%
1.0%
VOLTAGE TOLERANCE Note.3
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
1000ms, 50ms/230VAC
1000ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)
12ms/230VAC
12ms/115VAC
250 ~ 370VDC
VOLTAGE RANGE
Note.4 90 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF≥0.95/230VAC PF≥0.99/115VAC at full load
INPUT
94%
95%
95.5%
96%
10.1A/115VAC
5.3A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 20A/115VAC
<0.75mA / 240VAC
40A/230VAC
105~120% rated output power
OVERLOAD
Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover
Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover
SHORT CIRCUIT
PROTECTION
14.5 ~ 16V
29 ~ 33V
43.5 ~ 49V
59 ~ 66V
OVER VOLTAGE
Protection type: Shut down O/P voltage, re-power on to recover
OVER TEMPERATURE
Protection type: Shut down O/P voltage, recovers automatically after temperature goes down
Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage
Please refer to the Function Manual.
OUTPUT VOLTAGE
PROGRAMMABLE(PV) Note 5
Adjustment of constant current level is allowable to 20 ~ 100% of rated current.
Please refer to the Function Manual.
OUTPUT CURRENT
PROGRAMMABLE(PC) Note 5
FUNCTION
Power ON: "Low" <0 ~ 0.5V or Short circuit
12V@0.5A tolerance 10%, ripple 150mVp-p
Power OFF: "Hi" >2 ~ 5V or Open circuit
REMOTE ON/OFF CONTROL
AUXILIARY POWER
DC-OK SIGNAL
The TTL signal out, PSU turn on = 4.5 ~ 5.5V; PSU turn off = -0.1 ~ 0.5V. Please refer to the Function Manual.
-30 ~ +70℃(Refer to “Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85℃, 10 ~ 95% RH non-condensing
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved; Design refer to EN61558-1, EN60335-1
I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC
I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/500VDC/25℃/ 70%RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Parameter
Conducted
Standard
Test Level / Note
Class B
EN55032 (CISPR32)
EN55032 (CISPR32)
EN61000-3-2
Radiated
Class B
EMC EMISSION
Harmonic Current
Voltage Flicker
EN55024 , EN61000-6-2
Parameter
ESD
Class A
SAFETY &
EN61000-3-3
-----
EMC
(Note.6)
Standard
Test Level / Note
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-6-2
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Radiated
Level 3
EFT / Burst
Surge
Level 3
EMC IMMUNITY
2KV/Line-Line 4KV/Line-Earth
Conducted
Level 3
Level 4
Magnetic Field
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
218.86K hrs min. Telcordia SR-332 (Bellcore) ; 69.81K hrs min. MIL-HDBK-217F (25℃)
240*115*41mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
1.74kg ; 8pcs/14.9kg/0.74CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. PV/PC functions when users do not use SVR.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
BLOCK DIAGRAM
PWM fosc : 55KHz
PFC fosc : 70KHz
POWER
SWITCH-
ING
EMI FILTER
&
RECTIFIER
RECTIFIERS
&
FILTER
+V
-V
PFC
CIRCUIT
I/P
FG
O.L.P.
DETECTION
CIRCUIT
PV/PC
O.L.P.
PWM
CONTROL
SHUT DOWN
O.V.P.
O.T.P.
PFC
CONTROL
REMOTE ON-OFF
CONTROL
REMOTE
ON-OFF
DC OK FUNCTION
STATIC CHARACTERISTIC
EFFICIENCY VS LOAD (48V MODEL)
100
95
90
85
80
75
70
65
60
100
90
80
70
60
50
40
115VAC
230VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
110
120
140 160 180
220
240 264
90 100
200
LOAD
INPUT VOLTAGE (V) 60Hz
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
DERATING CURVE
230VAC for 12V
230VAC for other
230VAC for 12V
230VAC for other
100
80
100
80
60
50
60
50
110VAC
110VAC
20
20
-30
0
10
20
30
40 45 50
60
70
-30
0
10
20
30
40 45 50
60
70
(HORIZONTAL)
(HORIZONTAL)
AMBIENT TEMPERATURE WITH CONDUCTION COOLING(℃)
AMBIENT TEMPERATURE WITH FORCED AIR COOLING(℃)
110VAC
for other
100
80
80
70
60
230VAC
for other
230VAC
for 12V
60
40
40
35
30
110VAC
for 12V
20
20
(HORIZONTAL)
90
-40
-25
0
20
45
55
65
75
-30
0
10
20
30
40 45 50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE WITH CONVECTION COOLING(℃)
Tcase (℃)
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
FUNCTION MANUAL
1.Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.
CN80
2
1
1413
EXTERNAL
VOLTAGE (DC)
PIN4 -GND-signal
PIN3 PV
12V
24V
36V
48V
14.4 28.8 43.2 57.6
12 24 36 48
100
Non-Linear
83.3
80
60
40
6
12 18 24
20
V
V
50
90
100
110
120
5
6
0
0
0
0
2.5
EXTERNAL VOLTAGE (DC)
OUTPUT VOLTAGE (%)
※ Caution: By factory default, the Output Voltage Programming is not activated, and PV (pin1) and PV-DIS(pin2) are shorted by connector. Whenever this
function is not needed to activate, as assumed in other sections’ diagrams, please keep PV (pin1) and PV-DIS(pin2) shorted ; otherwise
the power supply will have no output.
2.Output Current Programming (or, PC / remote current programming / dynamic current trim)
※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.
Iout
CN80
Non-linear
Operating Area
100
2
1
1413
83.3
For 50~100% Vo
EXTERNAL
VOLTAGE (DC)
For 120% Vo
PIN12 -GND-signal
PIN11 PC
20
V
1
1.83
5
EXTERNAL VOLTAGE(VDC)
※ Caution: By factory default, the Output Current Programming is not activated, and VCCS(pin13) and PC-DIS(pin14) are shorted by connector. Whenever
this function is not needed to activate, as assumed in other sections’ diagrams, please keep VCCS(pin13) and PC-DIS(pin14) shorted ;
otherwise, the power supply will have no output.
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
3.Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function.
CN80
CN80
2
1
2
1
1413
1413
EXTERNAL
VOLTAGE (DC)
switch
PIN8 -GND-signal
PIN8-GND-signal
PIN7 Remote ON-OFF
PIN7 Remote ON-OFF
Remote ON-OFF
Power Supply Status
“Low” <0~0.5V or Short circuit
“Hi” >2~5V or Open circuit
ON
OFF
4.DC-OK Signal
DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V.
CN80
2
1
1413
PIN9 DC-OK
Application
Circuit
PIN10 -GND-signal
DC-OK signal
Power Supply Status
“Hi” >4.5~5.5V
ON
“Low” <-0.1~0.5V
OFF
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
MECHANICAL SPECIFICATION
Case No.:272A
Unit:mm
240
232
3
TB2
1
2
3
TB1
3
2
1
TB3
4
5
6
1
2
13
14
SVR
CN80
4-ψ4.2 L=6
120
tc
ꢀtc : Max. Case Temperature
AC Input Terminal(TB1) Pin NO. Assignment
DC Output Terminal (TB2,TB3) Pin NO. Assignment
Pin No. Assignment
Max mounting torque
Terminal
Pin No. Assignment
Terminal
Max mounting torque
1
2
3
AC/L
AC/N
1,2,3
4,5,6
+V
-V
(MW)
NEL-400
DECA
T42-BS11-03
5Kgf-cm
13.5Kgf-cm
※Control Pin No. Assignment(CN80): HRS DF11-14DP-2DS or equivalent
2
1
Mating Housing
Terminal
HRS DF11-14DS or equivalent
HRS DF11-**SC or equivalent
14
13
Pin No.
Function
PV
Description
Connection for output voltage programming.
Short connecting between PV (pin1) and PV-DIS (pin2) if output voltage programming function is not activated.
1,3
2
PV-DIS
4,8,10,12 GND (Signal) Negative output voltage signal.
Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin6).
The maximum load current is 0.5A. This output is not controlled by “Remote ON-OFF”.
Auxiliary voltage output GND.
5
6
7
+12V-AUX
GND-AUX
The signal return is isolated from the output terminals (+V & -V).
The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF.
Short (0 ~ 0.5V): Power ON; Open (2 ~ 5V): Power OFF ; The maximum input voltage is 5.5V.
Low (-0.1 ~ 0.5V): When the Vout≦80% 5%.
Remote
ON-OFF
9
DC-OK
High (4.5 ~ 5.5V): When Vout≧80% 5%.
The maximum sink current is 10mA and only for output.
11
13
14
PC
Connection for constant current level programming.
Vccs
Positive output voltage signal.
PC-DIS
Short connecting between Vccs (pin13) and PC-DIS (pin14) if output current programming function is not activated.
File Name:UHP-1000-SPEC 2019-02-01
1000W Slim Type with PFC Switching Supply
UHP-1000 series
Operate with additional aluminum plate and fan
In order to meet the “Derating Curve” and the “Static Characteristics” , UHP-1000 series can be installed onto an aluminum plate(or the cabinet of the same size)
on the bottom or apply forced air cooled solution. The size of the suggested aluminum plate and configuration of fan are shown as below. And for optimizing
thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-1000 series must be firmly mounted
at the center of the aluminum plate.
unit:mm
M3*4
450
450
23.5CFM
FAN
Air flow
direction
TB2
1
2
TB1
3
3
2
TB3
1
4
5
6
SVR
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:UHP-1000-SPEC 2019-02-01
相关型号:
UHP-12/21-D48NB-C
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT PACKAGE-9
MURATA
UHP-12/21-D48NL2-C
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT PACKAGE-9
MURATA
UHP-12/21-D48PB-C
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT PACKAGE-9
MURATA
UHP-12/21-D48PBL2-C
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT PACKAGE-9
MURATA
UHP-12/21-D48PL1-C
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT PACKAGE-9
MURATA
©2020 ICPDF网 联系我们和版权申明