1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
UL62368-1
TPTC004 IEC62368-1
■ Features
ꢀSlim and Low profile (41mm)
■ Applications
ꢀIndustrial automation machinery
ꢀIndustrial control system
ꢀFanless and conduction-cooled design
ꢀBuilt-in active PFC function
ꢀMechanical and electrical equipment
ꢀElectronic instruments, equipment
or apparatus
ꢀ-3 ~+0 7℃0working temperature
ꢀOutput voltage and constant current level programmable
ꢀProtections: Short circuit / Overload /
Over voltage / Over temperature
ꢀBuilt-in remote ON-OFF control
ꢀDC OK active signal
ꢀTest and measurement instrument
ꢀLaser related machine
ꢀCharging related equipment
ꢀHousehold appliances
ꢀOperating altitude up to 5000 meter (Note.7)
ꢀLED indicator for power on
ꢀOptional PMBus or CANBus protocol
ꢀ5 years warranty
■ Description
UHP-1500 series is a 1500W single-output slim type power supply with 41mm of low profile design.
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 24V and
48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ 70℃ under air
convection without fan. UHP-1500 has the complete protection functions and 5G anti-vibration capability;
It is complied with the international safety regulations such as TUV EN62368-1, UL62368-1, and the design
refers to EN61558-1 and EN60335-1. UHP-1500 series serves as a high performance power supply solution
for various industrial applications.
■ Model Encoding
UHP - 1500 - 24
Communication protocol option
Output voltage(24V/48V)
Rated wattage
Series name
Type
Blank
PM
Communication Protocol
None
Note
In Stock
PMBus protocol
CANBus protocol
By request
By request
CAN
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
SPECIFICATION
MODEL
UHP-1500-24
UHP-1500-48
48V
DC VOLTAGE
24V
RATED CURRENT
62.5A
31.5A
1512W
RATED POWER
1500W
RIPPLE & NOISE (max.) Note.2
240mVp-p
350mVp-p
By built-in potentiometer, SVR
VOLTAGE ADJ. RANGE
OUTPUT
24~28.8V
48~57.6V
1.0%
1.0%
VOLTAGE TOLERANCE Note.3
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC at 75% load
10ms/230VAC at full load
VOLTAGE RANGE
Note.4 90 ~ 264VAC 250 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF≥0.95/230VAC at full load
95%
INPUT
96%
8A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 60A/230VAC
<0.75mA / 240VAC
105~125% rated output power
OVERLOAD
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
SHORT CIRCUIT
PROTECTION
30 ~ 35V
60 ~ 67V
OVER VOLTAGE
Protection type :Shut down O/P voltage,re-power on to recover
OVER TEMPERATURE
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage
Please refer to the Function Manual.
OUTPUT VOLTAGE
PROGRAMMABLE(PV) Note 5
Adjustment of constant current level is allowable to 20 ~ 100% of rated current.
Please refer to the Function Manual.
OUTPUT CURRENT
PROGRAMMABLE(PC) Note 5
FUNCTION
Power ON : Short circuit
Power OFF : Open circuit
REMOTE ON/OFF CONTROL
AUXILIARY POWER
DC-OK SIGNAL
12V @ 0.4A tolerance 10%, ripple=150mVp-p
The TTL signal out, PSU turn on = 4.4 ~ 5.5V ; PSU turn off = -0.5 ~ 0.5V. Please refer to the Function Manual.
-30 ~ +70℃(Refer to “Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH non-condensing
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL62368-1,TUV EN62368-1, EAC TP TC 004 approved; Design refers to EN61558-1, EN60335-1(by request)
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Parameter
Conducted
Standard
Test Level / Note
Class B
EN55032 (CISPR32)
EN55032 (CISPR32)
EN61000-3-2
Radiated
Class A
EMC EMISSION
Harmonic Current
Voltage Flicker
EN55024 , EN61000-6-2
Parameter
ESD
Class A
SAFETY &
EN61000-3-3
-----
EMC
(Note.6)
Standard
Test Level / Note
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-6-2
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Radiated
Level 3
EFT / Burst
Surge
Level 3
EMC IMMUNITY
2KV/Line-Line 4KV/Line-Earth
Conducted
Level 3
Level 4
Magnetic Field
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
181.47K hrs min. Telcordia SR-332 (Bellcore) ; 56.72K hrs min. MIL-HDBK-217F (25℃)
290*140*41mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
2.51kg ; 6pcs/16.06kg/0.86CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. PV/PC functions when users do not use SVR.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
BLOCK DIAGRAM
PFC fosc : 70KHz
PWM fosc : 55KHz
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
RECTIFIERS
&
FILTER
+V
-V
POWER
EMI
FILTER
I/P
&
PFC
SWITCHING
O.V.P.
DETECTION
CIRCUIT
PV
PC
PWM
CONTROL
PFC
CONTROL
O.T.P.
MCU
DETECTION
CIRCUIT
DC OK
DATA
ISOLATION
MCU
Remote ON-OFF
O.T.P.
PM BUS
or
DATA
ISOLATION
5V
RECTIFIERS
&
FILTER
AUX
POWER
CAN BUS
(Optional)
12V/0.4A
AUX POWER
EFFICIENCY VS LOAD (48V MODEL)
STATIC CHARACTERISTIC
100
95
90
85
80
75
70
65
60
100
90
80
70
60
50
40
115VAC
230VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
110
120
140 160 180
220
240 264
LOAD
90 100
200
INPUT VOLTAGE (V) 60Hz
DERATING CURVE
100
80
100
230VAC
80
230VAC
Input only
230VAC
Input only
60
110VAC
60
50
40
50
40
20
20
(HORIZONTAL)
(HORIZONTAL)
-30
-25 -10
0
20
40
50
60
70
-30
-25 -10
0
20
40 45 50
60
70
AMBIENT TEMPERATURE WITH CONDUCTION COOLING(℃)
AMBIENT TEMPERATURE WITH FORCED AIR COOLING(℃)
230VAC
Input only
100
100
80
70
60
80
60
40
40
25
20
20
(HORIZONTAL)
(HORIZONTAL)
70
-30
-25 -10
0
20
40 45 50
60
70
-40
-25
-10
0
15
30
50
60
Tcase (℃)
AMBIENT TEMPERATURE CONVECTION COOLING(℃)
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
FUNCTION MANUAL
1.Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.
PIN1 PV
EXTERNAL
VOLTAGE (DC)
CN71
PIN3 & 4 -GND-signal
Vout
100
120
100
83.3
80
Non-Linear
60
40
50
20
V
50
90
100
110
120
V
0
0.4
1
4.74.8
OUTPUT VOLTAGE (%)
◎ The rated current should change with the Output Voltage Programming accordingly.
EXTERNAL VOLTAGE (DC)
2.Constant Current Programming (or, PC / remote current programming / dynamic current trim)
※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.
PIN2 PC
EXTERNAL
VOLTAGE (DC)
CN71
PIN3 & 4 -GND-signal
※ Covered by over temperature protection, auto de-rating function works under operation either in PC mode or under control by communication protocol.
T1(Typ.): Maximum ambient temperature of full load.
T2(Typ.): T1+5℃.
Iout
100
80
110
100
Non-Linear
Non-Linear
60
50
40
20
20
V
0
0.4
1
4.7 4.8
T1
T2
(HORIZONTAL)
AMBIENT TEMPERATURE (℃)
EXTERNAL VOLTAGE (DC)
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
3.Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function.
Remote ON-OFF
Short circuit
Power Supply Status
ON
PIN5 Remote ON-OFF
PIN7 & 8 +12V-AUX
CN71
Open circuit
OFF
4.DC-OK Signal
DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V.
PIN6 DC OK
DC-OK signal
Power Supply Status
“High” >4.4~5.5V
“Low” <-0.5~0.5V
ON
CN71
OFF
PIN9 & 10 GND-AUX
5.PMBus Communication Interface
UHP-1500 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details,
please refer to the Function Manual.
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
MECHANICAL SPECIFICATION
Case No.277A
Unit:mm
290
282
4
TB2
3
2 TB1
1
TB3
2-M5
DIP SW
1 2 3
SVR
1
2
11
12
CN71
4-ψ4.5 L=6
(Optional)
145
tc
ꢀtc : Max. Case Temperature
AC Input Terminal(TB1) Pin NO. Assignment
DC Output Terminal(TB2,TB3) Pin NO. Assignment
Pin No. Assignment
Max mounting torque
Terminal
Pin No. Assignment
Terminal
Max mounting torque
1
2
3
AC/L
AC/N
TB2
TB3
+V
-V
(MW)
HS455A
DECA T25
18Kgf-cm
8Kgf-cm
※DIP SW:
Pin No.
Function
A0
Description
1
2
3
A1
PMBus / CANBus interface address switch.
A2
※Control Pin No. Assignment(CN71) : HRS DF11-12DP-2DS or equivalent
2
1
Mating Housing
Terminal
HRS DF11-12DS or equivalent
HRS DF11-**SC or equivalent
12 11
Pin No.
Function
PV
Description
1
2
Connection for output voltage programming.(Note1)
PC
Connection for constant current level programming.(Note.1)
3,4
GND (Signal) Negative output voltage signal.
The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and 12-AUX.(Note.2)
Short (10.8 ~ 13.2V) : Power ON ; Open(0 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V
Low (-0.5 ~ 0.5V) : When the Vout≦80% 6%.
Remote
ON-OFF
5
6
DC-OK
High (4.4 ~ 5.5V) : When Vout≧80% 6%.
The maximum sourcing current is 10mA and only for output.(Note.2)
Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin3 & 4).
The maximum load current is 0.4A. This output is not controlled by “Remote ON-OFF”.
Auxiliary voltage output GND.
7,8
9,10
11
+12V-AUX
GND-AUX
The signal return is isolated from the output terminals (+V & -V).
For PMBus model: Serial Data used in the PMBus interface. (Note.2)
For CANBus model: Data line used in CANBus interface. (Note.2)
For PMBus model: Serial Clock used in the PMBus interface. (Note.2)
For CANBus model: Data line used in CANBus interface. (Note.2)
SDA
CANH
SCL
12
CANL
Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX.
File Name:UHP-1500-SPEC 2020-02-05
1500W Conduction Cooling with PFC Switching Supply
UHP-1500 series
Operate with additional aluminum plate
In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-1500 series must be installed onto an aluminum plate(or the cabinet of the same size)
on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and
smooth surface (or coated with thermal grease), and UHP-1500 series must be firmly mounted at the center of the aluminum plate.
unit:mm
M4*4
450
450
TB2
3
2
1
TB1
TB3
DIP SW
1 2 3
SVR
Air flow
direction
(Optional)
40CFM
FAN
145mm
File Name:UHP-1500-SPEC 2020-02-05
相关型号:
UHP-1500-24
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-1500-24CAN
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-1500-24PM
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-1500-48
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-1500-48CAN
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-1500-48PM
1500W Conduction Cooling with PFC Switching SupplyWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-2.5/50-D48
DC-DC Regulated Power Supply Module, 1 Output, Hybrid,Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA
UHP-2.5/50-D48N
DC-DC Regulated Power Supply Module, 1 Output, Hybrid,Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA
UHP-2.5/50-D48S
DC-DC Regulated Power Supply Module, 1 Output, Hybrid,Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA
UHP-2.5/50-D48SL1
DC-DC Regulated Power Supply Module, 1 Output, Hybrid,Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA
UHP-200A
200W Single Output with PFC FunctionWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
UHP-200A-4.2
200W Single Output with PFC FunctionWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL
©2020 ICPDF网 联系我们和版权申明