UHP-1500 [MEANWELL]

1500W Conduction Cooling with PFC Switching Supply;
UHP-1500
型号: UHP-1500
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

1500W Conduction Cooling with PFC Switching Supply

功率因数校正
文件: 总7页 (文件大小:324K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
UL62368-1  
TPTC004 IEC62368-1  
Features  
Slim and Low profile (41mm)  
Applications  
Industrial automation machinery  
Industrial control system  
Fanless and conduction-cooled design  
Built-in active PFC function  
Mechanical and electrical equipment  
Electronic instruments, equipment  
or apparatus  
-3 ~+0 70working temperature  
Output voltage and constant current level programmable  
Protections: Short circuit / Overload /  
Over voltage / Over temperature  
Built-in remote ON-OFF control  
DC OK active signal  
Test and measurement instrument  
Laser related machine  
Charging related equipment  
Household appliances  
Operating altitude up to 5000 meter (Note.7)  
LED indicator for power on  
Optional PMBus or CANBus protocol  
5 years warranty  
Description  
UHP-1500 series is a 1500W single-output slim type power supply with 41mm of low profile design.  
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 24V and  
48V. In addition to the high efficiency up to 96%, that the whole series operates from -30~ 70under air  
convection without fan. UHP-1500 has the complete protection functions and 5G anti-vibration capability;  
It is complied with the international safety regulations such as TUV EN62368-1, UL62368-1, and the design  
refers to EN61558-1 and EN60335-1. UHP-1500 series serves as a high performance power supply solution  
for various industrial applications.  
Model Encoding  
UHP - 1500 - 24  
Communication protocol option  
Output voltage(24V/48V)  
Rated wattage  
Series name  
Type  
Blank  
PM  
Communication Protocol  
None  
Note  
In Stock  
PMBus protocol  
CANBus protocol  
By request  
By request  
CAN  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
SPECIFICATION  
MODEL  
UHP-1500-24  
UHP-1500-48  
48V  
DC VOLTAGE  
24V  
RATED CURRENT  
62.5A  
31.5A  
1512W  
RATED POWER  
1500W  
RIPPLE & NOISE (max.) Note.2  
240mVp-p  
350mVp-p  
By built-in potentiometer, SVR  
VOLTAGE ADJ. RANGE  
OUTPUT  
24~28.8V  
48~57.6V  
1.0%  
1.0%  
VOLTAGE TOLERANCE Note.3  
LINE REGULATION  
0.5%  
0.5%  
0.5%  
0.5%  
LOAD REGULATION  
SETUP, RISE TIME  
1800ms, 60ms/230VAC at full load  
HOLD UP TIME (Typ.)  
16ms/230VAC at 75% load  
10ms/230VAC at full load  
VOLTAGE RANGE  
Note.4 90 ~ 264VAC 250 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
47 ~ 63Hz  
PF0.95/230VAC at full load  
95%  
INPUT  
96%  
8A/230VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
LEAKAGE CURRENT  
Cold start 60A/230VAC  
<0.75mA / 240VAC  
105~125% rated output power  
OVERLOAD  
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.  
Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.  
SHORT CIRCUIT  
PROTECTION  
30 ~ 35V  
60 ~ 67V  
OVER VOLTAGE  
Protection type :Shut down O/P voltage,re-power on to recover  
OVER TEMPERATURE  
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down  
Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage  
Please refer to the Function Manual.  
OUTPUT VOLTAGE  
PROGRAMMABLE(PV) Note 5  
Adjustment of constant current level is allowable to 20 ~ 100% of rated current.  
Please refer to the Function Manual.  
OUTPUT CURRENT  
PROGRAMMABLE(PC) Note 5  
FUNCTION  
Power ON : Short circuit  
Power OFF : Open circuit  
REMOTE ON/OFF CONTROL  
AUXILIARY POWER  
DC-OK SIGNAL  
12V @ 0.4A tolerance 10%, ripple=150mVp-p  
The TTL signal out, PSU turn on = 4.4 ~ 5.5V ; PSU turn off = -0.5 ~ 0.5V. Please refer to the Function Manual.  
-30 ~ +70(Refer to “Derating Curve")  
WORKING TEMP.  
20 ~ 90% RH non-condensing  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
-40 ~ +85, 10 ~ 95% RH non-condensing  
ENVIRONMENT  
0.03%/(0 ~ 50℃)  
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes  
UL62368-1,TUV EN62368-1, EAC TP TC 004 approved; Design refers to EN61558-1, EN60335-1(by request)  
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC  
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25/ 70%RH  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
Parameter  
Conducted  
Standard  
Test Level / Note  
Class B  
EN55032 (CISPR32)  
EN55032 (CISPR32)  
EN61000-3-2  
Radiated  
Class A  
EMC EMISSION  
Harmonic Current  
Voltage Flicker  
EN55024 , EN61000-6-2  
Parameter  
ESD  
Class A  
SAFETY &  
EN61000-3-3  
-----  
EMC  
(Note.6)  
Standard  
Test Level / Note  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-6-2  
EN61000-4-6  
EN61000-4-8  
Level 3, 8KV air ; Level 2, 4KV contact  
Radiated  
Level 3  
EFT / Burst  
Surge  
Level 3  
EMC IMMUNITY  
2KV/Line-Line 4KV/Line-Earth  
Conducted  
Level 3  
Level 4  
Magnetic Field  
>95% dip 0.5 periods, 30% dip 25 periods,  
>95% interruptions 250 periods  
Voltage Dips and Interruptions  
EN61000-4-11  
MTBF  
181.47K hrs min. Telcordia SR-332 (Bellcore) ; 56.72K hrs min. MIL-HDBK-217F (25)  
290*140*41mm (L*W*H)  
OTHERS  
NOTE  
DIMENSION  
PACKING  
2.51kg ; 6pcs/16.06kg/0.86CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance :includes set up tolerance, line regulation and load regulation.  
4. Derating may be needed under low input voltages. Please check the derating curve for more details.  
5. PV/PC functions when users do not use SVR.  
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on  
a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to  
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)  
7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
BLOCK DIAGRAM  
PFC fosc : 70KHz  
PWM fosc : 55KHz  
ACTIVE  
INRUSH  
CURRENT  
LIMITING  
RECTIFIERS  
RECTIFIERS  
&
FILTER  
+V  
-V  
POWER  
EMI  
FILTER  
I/P  
&
PFC  
SWITCHING  
O.V.P.  
DETECTION  
CIRCUIT  
PV  
PC  
PWM  
CONTROL  
PFC  
CONTROL  
O.T.P.  
MCU  
DETECTION  
CIRCUIT  
DC OK  
DATA  
ISOLATION  
MCU  
Remote ON-OFF  
O.T.P.  
PM BUS  
or  
DATA  
ISOLATION  
5V  
RECTIFIERS  
&
FILTER  
AUX  
POWER  
CAN BUS  
(Optional)  
12V/0.4A  
AUX POWER  
EFFICIENCY VS LOAD (48V MODEL)  
STATIC CHARACTERISTIC  
100  
95  
90  
85  
80  
75  
70  
65  
60  
100  
90  
80  
70  
60  
50  
40  
115VAC  
230VAC  
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%  
110  
120  
140 160 180  
220  
240 264  
LOAD  
90 100  
200  
INPUT VOLTAGE (V) 60Hz  
DERATING CURVE  
100  
80  
100  
230VAC  
80  
230VAC  
Input only  
230VAC  
Input only  
60  
110VAC  
60  
50  
40  
50  
40  
20  
20  
(HORIZONTAL)  
(HORIZONTAL)  
-30  
-25 -10  
0
20  
40  
50  
60  
70  
-30  
-25 -10  
0
20  
40 45 50  
60  
70  
AMBIENT TEMPERATURE WITH CONDUCTION COOLING()  
AMBIENT TEMPERATURE WITH FORCED AIR COOLING()  
230VAC  
Input only  
100  
100  
80  
70  
60  
80  
60  
40  
40  
25  
20  
20  
(HORIZONTAL)  
(HORIZONTAL)  
70  
-30  
-25 -10  
0
20  
40 45 50  
60  
70  
-40  
-25  
-10  
0
15  
30  
50  
60  
Tcase ()  
AMBIENT TEMPERATURE CONVECTION COOLING()  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
FUNCTION MANUAL  
1.Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)  
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.  
PIN1 PV  
EXTERNAL  
VOLTAGE (DC)  
CN71  
PIN3 & 4 -GND-signal  
Vout  
100  
120  
100  
83.3  
80  
Non-Linear  
60  
40  
50  
20  
V
50  
90  
100  
110  
120  
V
0
0.4  
1
4.74.8  
OUTPUT VOLTAGE (%)  
The rated current should change with the Output Voltage Programming accordingly.  
EXTERNAL VOLTAGE (DC)  
2.Constant Current Programming (or, PC / remote current programming / dynamic current trim)  
The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.  
PIN2 PC  
EXTERNAL  
VOLTAGE (DC)  
CN71  
PIN3 & 4 -GND-signal  
Covered by over temperature protection, auto de-rating function works under operation either in PC mode or under control by communication protocol.  
T1(Typ.): Maximum ambient temperature of full load.  
T2(Typ.): T1+5.  
Iout  
100  
80  
110  
100  
Non-Linear  
Non-Linear  
60  
50  
40  
20  
20  
V
0
0.4  
1
4.7 4.8  
T1  
T2  
(HORIZONTAL)  
AMBIENT TEMPERATURE ()  
EXTERNAL VOLTAGE (DC)  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
3.Remote ON-OFF Control  
The power supply can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function.  
Remote ON-OFF  
Short circuit  
Power Supply Status  
ON  
PIN5 Remote ON-OFF  
PIN7 & 8 +12V-AUX  
CN71  
Open circuit  
OFF  
4.DC-OK Signal  
DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V.  
PIN6 DC OK  
DC-OK signal  
Power Supply Status  
“High” >4.4~5.5V  
“Low” <-0.5~0.5V  
ON  
CN71  
OFF  
PIN9 & 10 GND-AUX  
5.PMBus Communication Interface  
UHP-1500 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details,  
please refer to the Function Manual.  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
MECHANICAL SPECIFICATION  
Case No.277A  
Unit:mm  
290  
282  
4
TB2  
3
2 TB1  
1
TB3  
2-M5  
DIP SW  
1 2 3  
SVR  
1
2
11  
12  
CN71  
44.5 L=6  
(Optional)  
145  
tc  
tc : Max. Case Temperature  
AC Input Terminal(TB1) Pin NO. Assignment  
DC Output Terminal(TB2,TB3) Pin NO. Assignment  
Pin No. Assignment  
Max mounting torque  
Terminal  
Pin No. Assignment  
Terminal  
Max mounting torque  
1
2
3
AC/L  
AC/N  
TB2  
TB3  
+V  
-V  
(MW)  
HS455A  
DECA T25  
18Kgf-cm  
8Kgf-cm  
DIP SW:  
Pin No.  
Function  
A0  
Description  
1
2
3
A1  
PMBus / CANBus interface address switch.  
A2  
Control Pin No. Assignment(CN71) : HRS DF11-12DP-2DS or equivalent  
2
1
Mating Housing  
Terminal  
HRS DF11-12DS or equivalent  
HRS DF11-**SC or equivalent  
12 11  
Pin No.  
Function  
PV  
Description  
1
2
Connection for output voltage programming.(Note1)  
PC  
Connection for constant current level programming.(Note.1)  
3,4  
GND (Signal) Negative output voltage signal.  
The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and 12-AUX.(Note.2)  
Short (10.8 ~ 13.2V) : Power ON ; Open(0 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V  
Low (-0.5 ~ 0.5V) : When the Vout80% 6%.  
Remote  
ON-OFF  
5
6
DC-OK  
High (4.4 ~ 5.5V) : When Vout80% 6%.  
The maximum sourcing current is 10mA and only for output.(Note.2)  
Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin3 & 4).  
The maximum load current is 0.4A. This output is not controlled by “Remote ON-OFF”.  
Auxiliary voltage output GND.  
7,8  
9,10  
11  
+12V-AUX  
GND-AUX  
The signal return is isolated from the output terminals (+V & -V).  
For PMBus model: Serial Data used in the PMBus interface. (Note.2)  
For CANBus model: Data line used in CANBus interface. (Note.2)  
For PMBus model: Serial Clock used in the PMBus interface. (Note.2)  
For CANBus model: Data line used in CANBus interface. (Note.2)  
SDA  
CANH  
SCL  
12  
CANL  
Note1: Non-isolated signal, referenced to [GND(signal)].  
Note2: Isolated signal, referenced to GND-AUX.  
File Name:UHP-1500-SPEC 2020-02-05  
1500W Conduction Cooling with PFC Switching Supply  
UHP-1500 series  
Operate with additional aluminum plate  
In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-1500 series must be installed onto an aluminum plate(or the cabinet of the same size)  
on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and  
smooth surface (or coated with thermal grease), and UHP-1500 series must be firmly mounted at the center of the aluminum plate.  
unit:mm  
M4*4  
450  
450  
TB2  
3
2
1
TB1  
TB3  
DIP SW  
1 2 3  
SVR  
Air flow  
direction  
(Optional)  
40CFM  
FAN  
145mm  
File Name:UHP-1500-SPEC 2020-02-05  

相关型号:

UHP-1500-24

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-1500-24CAN

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-1500-24PM

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-1500-48

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-1500-48CAN

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-1500-48PM

1500W Conduction Cooling with PFC Switching Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-2.5/50-D48

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UHP-2.5/50-D48N

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UHP-2.5/50-D48S

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UHP-2.5/50-D48SL1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UHP-200A

200W Single Output with PFC Function

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL

UHP-200A-4.2

200W Single Output with PFC Function

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MEANWELL