ULP-150-24 [MEANWELL]
150W U-Bracket Single Output with PFC Function; 150W的U型支架单路输出带PFC功能型号: | ULP-150-24 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 150W U-Bracket Single Output with PFC Function |
文件: | 总2页 (文件大小:292K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
150W U-Bracket Single Output with PFC Function
ULP-150 series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC compliance to EN61000-3-2 class C
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Half encapsulated
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
Suitable for built-in type LED applications
3 years warranty
SPECIFICATION
MODEL
ULP-150-24
ULP-150-36
ULP-150-15
ULP-150-48
ULP-150-12
DC VOLTAGE
15V
24V
36V
48V
12V
RATED CURRENT
10A
6.3A
4.2A
3.2A
12.5A
CURRENT RANGE
0 ~ 10A
150W
0 ~ 6.3A
151.2W
150mVp-p
21.6~26.4V
2.0%
0 ~ 4.2A
151.2W
250mVp-p
32.4~39.6V
2.0%
0 ~ 3.2A
153.6W
250mVp-p
43.2~52.8V
2.0%
0 ~ 12.5A
150W
RATED POWER
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
150mVp-p
13.5~16.5V
2.0%
100mVp-p
11.0~13.2V
OUTPUT
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
1.0%
1.0%
1.0%
1.0%
1.0%
2000ms, 100ms/230VAC
3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
127 ~ 417VDC
VOLTAGE RANGE
Note.4 90 ~ 295VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF 0.98/115VAC
PF>0.96/230VAC PF 0.94/277VAC at full load
91.5% 93%
1A/230VAC 0.7A/277VAC
INPUT
93%
93%
91.5%
2A/115VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 65A/230VAC
<0.75mA / 277VAC
130~185% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
17 ~ 21V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
95 (RTH2)
26.7 ~ 32.4V
41.4 ~ 48.6V
53 ~ 64.8V
13.6 ~ 16.3V
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +70 (Refer to "Derating Curve")
WORKING TEMP.
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 60
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to EN61347-2-13,IEC61347-2-13,UL8750
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE Note.6
ISOLATION RESISTANCE
EMC EMISSION
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
EMC
(Note 5)
Compliance to EN55015, EN61000-3-2 Class C( 60% load),EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
216.3K hrs min. MIL-HDBK-217F (25
215*67.4*33mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.67kg; 24PCS/17.5kg/0.65CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:ULP-150-SPEC 2011-08-11
150W U-Bracket Single Output with PFC Function
ULP-150 series
Mechanical Specification
Case No. 988
Unit:mm
7.5
4.5 4PL
194
208
3.5
3.5
215
211
201
33
1
2
3
4
1
2
3
3.5 4PL
DC Terminal pin NO. Assignment
AC Terminal pin NO. Assignment
Pin No. Assignment
Terminal
Pin No. Assignment
Terminal
1
2
3
4
V-
V-
1
2
3
FG
DECA
T31-C032033702
DECA
T31-C032043702
AC/L
AC/N
V+
V+
Block Diagram
POWER
SWITCH-
ING
SYNCHRONOUS
RECTIFIERS
+V
-V
EMI
BRIDGE
RECTIFIERS
APFC
CONTROLLER
I/P
FG
FILTER
&
FILTER
O.T.P.
DETECTION
CIRCUIT
PWM
O.L.P.
CONVERTER
O.V.P.
Derating Curve
Static Characteristics
100
90
80
70
60
50
40
130
Mount with a 300*500*2mm heatsink
100
80
100VAC
230VAC
60
40
20
-30
0
10
20
30
40 45 50 55 60 65 70 (HORIZONTAL)
90
100
110
135
155
230 295
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE (
)
File Name:ULP-150-SPEC 2011-08-11
相关型号: