XLG-100I-24-A [MEANWELL]
100W Constant Power Mode LED Driver;型号: | XLG-100I-24-A |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 100W Constant Power Mode LED Driver |
文件: | 总9页 (文件大小:721K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
100W Constant Power Mode LED Driver
XLG-100 series
IS 15885(Part 2/Sec13)
T
T
A
05
R-41027766
(for XLG-100I type only)
Note.12
■
‧Ⅰ
‧
‧
‧
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧Ⅰ
‧
■
℃℃
■
{
:
File Name:XLG-100-SPEC 2019-10-15
100W Constant Voltage+Constant Current LED Driver
XLG-100 series
SPECIFICATION
MODEL
XLG-100 -12-
XLG-100 -24-
12V
24V
DC VOLTAGE
CONSTANT CURRENT REGION Note.2
RATED CURRENT
8.4~ 12V
8A
16.8~ 24V
4A
96W
96W
RATED POWER
150mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.3
Adjustable for A/AB-Type only (via the built-in potentiometer)
4 ~ 8A
±3.0%
CURRENT ADJ RANGE
2~4A
±2.0%
±0.5%
±1%
VOLTAGE TOLERANCE Note.4
LINE REGULATION
OUTPUT
±0.5%
±2%
LOAD REGULATION
500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
12ms/ 230VAC 12ms/ 115VAC
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
100 ~ 305VAC
142 ~ 431VDC
VOLTAGE RANGE
Note.5
(Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE
POWER FACTOR
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)
AC CURRENT
47 ~ 63Hz
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
92%
INPUT
92%
1.1A / 115VAC 0.5A / 230VAC 0.42A/277VAC
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
8units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
NO LOAD
No load power consumption <0.5W(for standard version)
POWER CONSUMPTION
95 ~ 108%
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
13.5 ~ 18V
PROTECTION
27 ~ 34V
Shut down output voltage, re-power on to recover
320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
can survive input voltage stress of 440Vac for 48 hours
INPUT OVER VOLTAGE Note.7
Shut down output voltage, re-power on to recover
Tcase=-40 ~ +90℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Tcase=+90℃
OVER TEMPERATURE
WORKING TEMP.
MAX. CASE TEMP.
20 ~ 95% RH non-condensing
WORKING HUMIDITY
-40 ~ +90℃, 10 ~ 95% RH
±0.03%/℃(0 ~ 60℃)
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14;
EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-100I type only); IP67 approved
SAFETY STANDARDS Note.7
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Standard
Test Level/Note
-----
-----
Class C @load≥50%
-----
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EN61000-3-2 , GB/T17625.1
EN61000-3-3
EMC EMISSION
EMC
SAFETY &
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Standard
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Level 3
Level 4
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EMC IMMUNITY
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
1006.16K hrs min. Telcordia SR-332 (Bellcore) ; 276.37Khrs min. MIL-HDBK-217F (25℃)
140*63*32mm (L*W*H)
0.58Kg;24pcs /15Kg /0.85CUFT
℃
OTHERS
NOTE
DIMENSION
PACKING
℃℃
℃
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
SPECIFICATION
MODEL
XLG-100 -L-
XLG-100 -H-
RATED CURRENT
RATED POWER
CONSTANT CURRENT REGION
FULL POWER CURRENT RANGE 700~1050mA
OPEN CIRCUIT VOLTAGE (max.) 149V
700mA
100W
71 ~ 142V
2100mA
100W
27 ~ 56V
1750~2780mA
60V
OUTPUT
CURRENT ADJ. RANGE
CURRENT RIPPLE
CURRENT TOLERANCE
SET UP TIME
350~1050mA
3.0%(@rated current)
±5%
875~2780mA
500ms/230VAC, 1200ms/115VAC
100 ~ 305VAC
142VDC ~ 431VDC
VOLTAGE RANGE
Note.5
(Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section)
FREQUENCY RANGE
POWER FACTOR (Typ.)
47 ~ 63Hz
PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load
(Please refer to "Power Factor Characteristic" section)
THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC)
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
TOTAL HARMONIC DISTORTION
91%
EFFICIENCY (Typ.)
92.5%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
1.1A / 115VAC
0.5A / 230VAC
0.42A / 277VAC
COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
8 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
<0.75mA / 277VAC
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
STANDBY
Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version)
POWER CONSUMPTION
105 ~ 150%
OVER POWER
Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
160 ~ 220V
66 ~ 90V
PROTECTION OVER VOLTAGE
Shut down output voltage, re-power on to recover
320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
can survive input voltage stress of 440Vac for 48 hours
INPUT OVER VOLTAGE Note.7
Shut down output voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
Tcase=-40 ~ +90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
MAX. CASE TEMP.
Tcase=+90℃
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH non-condensing
±0.03%/℃(0 ~ 60℃)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14;
EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13, IS15885(Part2/Sec13)(for XLG-100I type only);IP67 approved
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Standard
Test Level/Note
-----
-----
Class C @load≥50%
-----
EN55015(CISPR15) ,GB/T17743
EN55015(CISPR15) ,GB/T17743
EN61000-3-2 ,GB/T17625.1
EN61000-3-3
EMC EMISSION
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Standard
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Level 3
Level 4
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EMC IMMUNITY
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
1006.16K hrs min. Telcordia SR-332 (Bellcore) ; 276.37Khrs min. MIL-HDBK-217F (25℃)
OTHERS
NOTE
DIMENSION
PACKING
140*63*32mm (L*W*H)
0.58Kg;24pcs /15Kg /0.85CUFT
℃
℃℃
℃
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
BLOCK DIAGRAM
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
+V
-V
I/P
FG
CIRCUIT
DIM+
DIM-
O.C.P.
(AB Type)
O.L.P.
O.T.P.
DETECTION
CIRCUIT
PWM
CONTROL
PFC
CONTROL
O.V.P.
DRIVING METHODS OF LED MODULE
※ I-V Operating Area
150V
60V
55V
50V
45V
40V
35V
30V
25V
20V
350mA,142V
875mA,56V
1750mA,56V
700mA,142V
140V
130V
120V
110V
100V
90V
2780mA,36V
1050mA,95V
80V
700mA,71V
1050mA,71V
70V
1750mA,27V
2800mA,27V
60V
0mA
200mA
400mA
600mA
800mA
1000mA
1200mA
0mA
500mA
1000mA
1500mA
2000mA
2500mA
3000mA
Recommend Performance Region
Recommend Performance Region
※ This series is able to work in either Constant Current mode (a
direct drive way) or Constant Voltage mode (usually through
additional DC/DC driver) to drive the LEDs.
100
In the constant current
region, the highest voltage
at the output of the driver
depends on the configuration
of the end systems.
(B)
Constant
Current area
(A)
Constant
Voltage area
60
(min.)
Should there be any
compatibility issues, please
please contact MEAN WELL.
(C)
Hiccup
Protection
100
50
Io(%)
Typical output current normalized by rated current (%)
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
DIMMING OPERATION
Vo-(Black)
Vo+(Red)
AC/N(Blue)
XLG-100
AC/L(Brown)
FG(Green/Yellow)
DIM+(Blue)
DIM-(White)
※ 3 in 1 dimming function (for AB-Type)
ꢀOutput constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance.
ꢀDirect connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
ꢀDimming source current from power supply: 100μA (typ.)
100%
90%
80%
+
+
Vo+
70%
60%
50%
40%
30%
20%
10%
0%
-
-
Vo-
DIM+
+
Additive Voltage
-
DIM-
“DO NOT connect "DIM- to Vo-"
0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V
Dimming input: Additive voltage
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
+
+
Vo+
-
-
Vo-
DIM+
Additive PWM signal
DIM-
“DO NOT connect "DIM- to Vo-"
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Duty cycle of additive 10V PWM signal dimming input
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
+
+
Vo+
-
-
Vo-
DIM+
Additive Resistance
DIM-
“DO NOT connect "DIM- to Vo-"
Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N
(N=driver quantity for synchronized dimming operatio)n
Dimming input: Additive resistance
Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
OUTPUT LOAD vs TEMPERATURE
230VAC
100
80
100
80
230VAC
230VAC
100VAC
Input only
Input only
60
40
60
40
20
20
-40
-30
-10
0
15
30
50
60
70
-40
-30
0
10
30
50
70
90
(HORIZONTAL)
(HORIZONTAL)
If XLG-100 operates in Constant Current mode with the rated
current the maximum workable Ta is 60℃ (Typ. 230VAC) or 50℃(Typ.100VAC)
Below 110VAC@ -30℃ may retry to 2nd setup
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
Constant Current Mode
1
0.98
0.96
0.94
0.92
0.9
100
90
80
70
60
50
40
277V
230V
115V
0.88
0.86
0.84
50%
60%
70%
80%
LOAD
90% 100%
100 110
140 160 180 200 220 240 260 280 305
INPUT VOLTAGE (V) 60Hz
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
XLG-100 series possess superior working efficiency that up to 92.5% can
be reached in field applications.
※ XLG-100-L Model, Tcase at 75℃
96
92
88
84
12%
11%
10%
9%
8%
7%
6%
5%
4%
3%
2%
1%
0%
277V
80
76
72
68
64
60
277V
230V
115V
230V
115V
50%
60%
70%
80%
90%
50%
60%
70%
80%
90%
100%
LOAD
LOAD
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
LIFE TIME
120
100
80
60
40
20
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90
Tc ase (
)
℃
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
MECHANICAL SPECIFICATION
Case No.:275B
Unit:mm
※ Blank-Type
140
134
125
300±20
300±20
AC/N(Blue)
Vo-(Black)
Vo+(Red)
AC/L(Brown)
FG(Green/Yellow)
57
SJOW 17AWGx3C
SJOW 17AWGx2C &05RN-F 2x1.0mm2
tc
&H05RN-F 3x1.0mm2
SJOW 14AWGx2C (for 12V)
4-Φ4.5
tc
※ A-Type
140
134
125
300±20
300±20
AC/N(Blue)
Vo-(Black)
Vo+(Red)
AC/L(Brown)
FG(Green/Yellow)
57
SJOW 17AWGx3C
SJOW 17AWGx2C &05RN-F 2x1.0mm2
tc
&H05RN-F 3x1.0mm2
SJOW 14AWGx2C (for 12V)
4-Φ4.5
tc
37.43
File Name:XLG-100-SPEC 2019-10-15
100W Constant Power Mode LED Driver
XLG-100 series
※ AB-Type
140
134
125
300±20
300±20
SJOW 17AWGx2C
&05RN-F 2x1.0mm2
Vo-(Black)
Vo+(Red)
AC/N(Blue)
AC/L(Brown)
DIM+(Blue)
DIM-(White)
FG(Green/Yellow)
57
SJOW 17AWGx3C
tc
&H05RN-F 3x1.0mm2
UL2517 20AWGx2C
350±20
4-Φ4.5
tc
37.43
INSTALLATION MANUAL
File Name:XLG-100-SPEC 2019-10-15
相关型号:
©2020 ICPDF网 联系我们和版权申明