MK12-1C90E-500W [MEDER]
Reed Sensors with Screw Fastening Mounting Holes; 干簧传感器与螺丝紧固安装孔型号: | MK12-1C90E-500W |
厂家: | MEDER ELECTRONIC |
描述: | Reed Sensors with Screw Fastening Mounting Holes |
文件: | 总4页 (文件大小:560K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MK12 Series
MEDER electronic
Reed Sensors with Screw Fas-
tening Mounting Holes
DESCRIPTION
MK12 sensors are magnetically operated Reed
Sensors designed for screw mounting. The larger
casing permits the use of higher rated switches.
The sensor should be mounted on a fixed surface
with the actuating magnet on the moving surface.
Introduction or removal of the magnetic field
determines the closing and opening of the Reed
Switch.
APPLICATIONS
• Position and limit switch
Pneumatic or hydraulic actuator position
• End motion detection for linear drive
Indication and end travel limit switch
• Machine industry
End motion detection and door/flap control
FEATURES
• Form A, B, and C available
•High power switches available
• Other cables, connectors and colors available
• Various case sizes available
• Five operate sensitivities available
• A choice of cable terminations and lengths are
available
DIMENSIONS
All dimensions in mm [inches]
www.meder.com
230
MEDER electronic
MK12 Series
Reed Sensors with Screw
Fastening Mounting Holes
ORDER INFORMATION
Part Number Example
Cable
length
(mm)
Contact
Form
Switch
Model
Magnetic
Sensitivity
Series
MK12 -
Termination
X
MK12 - 1A66 C - 500
W
XX
XX
X -
XXX
1A is the contact form
66 is the switch model
C is the magnetic sensitivity
500 is the cable length (mm)
W is the termination
66
84
B, C, D, E
1 Form A
Options
500 *
W
C, D, E
1 Form B
1 Form C
90
* Other cable lengths available
MAGNETIC SENSITIVITY
Sensitivity
Class
Pull-in
At Range
B
C
D
E
10 - 15
15 - 20
20 - 25
25 - 30
TERMINATION
For wire and termination details please consult factory.
Form C version requires 3 conductors.
The cable cut length includes:
5mm of wire stripped and tinned
W
www.meder.com
231
MK12 Series
MEDER electronic
Reed Sensors with Screw Fas-
tening Mounting Holes
CONTACT DATA
Switch Model →
Contact Form →
Switch 66
Form A
Switch 84
Form A
All Data at 20° C
Contact Ratings
Conditions
Min. Typ. Max. Min. Typ. Max. Units
Any DC combination of V & A not
to exceed their individual max.‘s
Switching Power
10
10
W
Switching Voltage
Switching Current
Carry Current
DC or peak AC
DC or peak AC
DC or peak AC
w/ 0.5 V & 10mA
200
0.5
400
0.5
1.0
150
V
A
1.25
150
A
Static Contact Resistance
mΩ
Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure
Dynamic Contact Resistance
200
200
mΩ
Ω
Insulation Resistance across
Contacts
100 volts applied
1010
*
1011
700
Breakdown Voltage across
Contact
225 *
Voltage applied for 60 sec. min.
VDC
Operation Time incl. Bounce Measured w/ 100 % overdrive
0.5
0.1
2.0
0.1
ms
ms
pF
Release Time
Capacitance
Measured w/ no coil suppression
at 10 kHz cross contact
0.2
0.7
Contact Operation **
Must Operate Condition
Must Release Condition
Environmental Data
Shock Resistance
Steady state field
Steady state field
10
4
30
27
15
6
30
27
AT
AT
1/2 sinus wave duration 11 ms
From 10 - 2000 Hz
50
20
50
20
g
Vibration Resistance
Ambient Temperature
Stock Temperature
g
10°C/ minute max. allowable
10°C/ minute max. allowable
5 sec. dwell
-20
-35
85
-20
-35
85
oC
oC
oC
85
85
Soldering Temperature
260
260
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive
switch.
*
Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if
more detail is required.
www.meder.com
232
MEDER electronic
MK12 Series
Reed Sensors with Screw
Fastening Mounting Holes
CONTACT DATA
Switch Model →
Contact Form →
Switch 90
All Data at 20° C
Contact Ratings
Switching Power
Form B / C
Conditions
Min. Typ. Max. Units
Any DC combination of V & A not
to exceed their individual max.‘s
3
W
Switching Voltage
Switching Current
Carry Current
DC or peak AC
DC or peak AC
DC or peak AC
w/ 0.5 V & 10 mA
175
0.25
1.2
V
A
A
Static Contact Resistance
150
mΩ
Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure
Dynamic Contact Resistance
250
mΩ
Ω
Insulation Resistance across
Contacts
100 volts applied
109
200
Breakdown Voltage across
Contact
Voltage applied for 60 sec. min.
VDC
Operation Time incl. Bounce Measured w/ 100 % overdrive
0.7
1.5
ms
ms
pF
Release Time
Capacitance
Measured w/ no coil suppression
at 10 kHz cross contact
1.0
Contact Operation *
Must Operate Condition
Must Release Condition
Environmental Data
Shock Resistance
Steady state field
Steady state field
10
4
35
30
AT
AT
1/2 sinus wave duration 11 ms
From 10 - 2000 Hz
50
20
g
Vibration Resistance
Ambient Temperature
Stock Temperature
g
10°C/ minute max. allowable
10°C/ minute max. allowable
5 sec. dwell
-20
-35
85
oC
oC
oC
85
Soldering Temperature
260
Please note: The indicated electrical data are maximum values and can vary downwards when
using a more sensitive switch.
* These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch
section. Consult factory if more detail is required.
www.meder.com
233
相关型号:
MK1212FE-A52(26)
Fixed Resistor, Metal Film, 0.25W, 12100ohm, 250V, 1% +/-Tol, -50,50ppm/Cel,
OHMITE
MK1212FEA26
RESISTOR, METAL FILM, 0.25W, 1%, 50ppm, 12100ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
OHMITE
MK1213FER52
RESISTOR, METAL FILM, 0.25W, 1%, 50ppm, 121000ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
OHMITE
©2020 ICPDF网 联系我们和版权申明